Professional Documents
Culture Documents
Celula Carga Single Point pwsmc3 Datasheet PDF
Celula Carga Single Point pwsmc3 Datasheet PDF
Data Sheet
Single Point
Load Cell
Special Features
HBI/DS-PWS-051-Rev1
Specifications
Model Type PWS
Accuracy class NTEP Class III
Maximum number of load cell intervals (nLC) 3000 Divisions Single
Maximum capacity (E max) kg 7 10 15 30 60 100 150
Minimum load cell verification interval (Vmin) g 1.0 1.4 2.0 4.2 8.4 14.0 21.0
Maximum platform size mm 300x300 450x450 600x600
Sensitivity (Cn) 2.0 ± .2
mV/V
Zero balance 0.0 ± .10
Temperature effect on zero balance (TK 0) ± 0.0195
Temperature effect on sensitivity (TK c) 1)
% of Cn
Temperature range / 10°C
+20…+40°C [+70…+105°F] ± 0.0175
-10…+20°C [+15…+70°F] ± 0.0117
Hysteresis error (d hy) 1) ± 0.017
Non-linearity (d lin) 1) % of
% of Cn
Cn ± 0.017
Creep (d cr) over 30 min. ± 0.0245
Eccentric load error 2) % of Cn/cm ± 0.005
Input resistance (R LC) 350 min
Ω
Output resistance (R O) 350 ± 3
Reference excitation voltage (U ref) V 5
V
Maximum excitation voltage (U max) 15
Insulation resistance (R is) GΩ >5
Nominal temperature range (B T) °C [°F] -10…40 [14…104]
Service temperature range (B tu) °C [°F] -10…50 [14…122]
Storage temperature range (B tl) -25…70 [-13…158]
Safe load limit (E L) % of Emax 150
at max. eccentricity mm 100 150 200
Ultimate load limit (E d) % of Emax 300
% of Emax
Lateral load limit (E lq ) 100
Deflection at E max (S nom), approx. mm < 0.4
Weight, approx. kg 0.5 0.7 0.9
Protection class to EN60529 (IEC529) IP65
Material: Measuring element Stainless Steel
Cable Fitting Gland -
Cable Sheath Polyurethane
Coating/Plating Silicone Rubber
1)
The sum of data for Non-linearity, Hysteresis and Temperature effect on sensitivity meets the requirements of NTEP HB44.
2)
Eccentric load error according to NTEP HB44.