Air in Motion.
Wolter Fans.
A08.5 #
Air in Motion. Wolter Fans. #
Wolter EC Induction Fans -
Closed Type
Ceiling Type
Application
In the context of a ductless Impulse Ventilation system, the architecture of a compartment itself serves
as the air duct. Air velocities are much lower and there is no resistance caused by a ducted system.
The total amount of energy consumed by an Impulse Ventilation system is therefore comparatively low.
More importantly, in enclosed areas, the induction effect of the Wolter Induction fans creates a
constant movement of air from the supply to the exhaust points, keeping CO levels to a minimum.
A well-designed distribution of such induction fans throughout the compartment will prevent the
accumulation of exhaust fumes in dead spots. The high velocity air stream along the ceiling level will
induce a low-velocity airstream at floor level, ensuring the required mixing of low-level and high-level
atmosphere.
Wolter Induction fans are ideal for use in underground car parks, passage ways, garages, warehouses
and workshops.
Advantages
The induction fans, allow
• Uniform air distribution and no dead spots.
• Better air quality, expel stagnant, dirty exhaust gas
and hot air
• Capital cost of the induction fan system is
outweighed by potential savings over the
traditional ducted system. ie costly installation of
ductwork becomes obsolete
Computational-Fluid-Dynamics
Design
The initial step in the design of induction fan ven-
tilation system should always be a careful analysis
of the air distribution and ventilation situation
based on thorough CFD design.
CFD simulation uses purpose-built software
that allows us to create a 3-dimensional image
of the compartment or car park. After determi-
ning all relevant parameters such as required
air-change rates, volume and air flow direction,
the different ventilation scenarios can be studied
taking into account all of the above factors. The
number, size and positioning of induction fans
can then be optimised. CFD software visualizes
direction vectors of airflows and mean age of air
distribution in all areas of the compartment or
underground car park. CFD design can also be
used to simulate the fume distribution throughout
the compartment and the induction fans can be
positioned accordingly.
WOLTER will be happy to assist you early during
the design stage of your induction ventilation
project.
Page 3
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Wolter Induction Fan
Manufactured to cover all profile requirements in relevant specifications and incorporated with high
efficient motors that are generally maintenance-free.
Beside the existing A/C E series, a new registered design feature of the WOLTER EC Induction Fan
helps reduce energy costs by nearly 60% compare to conventional motor. Moreover, it allows a 120%
increase in the amount of airflow through induction to guarantee ventilation in every corner of the area.
Technical Information
• Impeller:
Impellers of high quality aluminum sheet with fixed pitch angle. They are class Q2.5 balanced in
accordance with VDI 2060 / ISO1940/1-1986.
• EC Motor / Isolator Switch:
The unit comes with a number of motorized impellers to give a high volume flow and induction
capability. Mounted with wire guard and equipped with 2/4 different speeds to suit the
respective site requirements in unidirectional airflow direction. Four speed type as optional.
Motors are connected to an external terminal box. Protection class E is IP55 according to
IEC34-5 with 1/3 of the heat loss compared to those normally incurred by a conventional AC or
3-phase motor. Each induction fan unit has a starting current lower than 1A under high speed
mode.
• Housing:
The low profile fan housing of the induction fan is manufactured as one integral unit to minimise
headroom obstruction. The overall low profile height of the unit is 298 mm. They do not
significantly obstruct headroom heights within the compartment or car park space. Isolator
switches, speed control, alarm function, lockable isolator switch can be fitted as optional extras.
• Fan inlet cone and outlet tube:
The inlet cone and outlet tube are manufactured from precision injection-moulded casted
aluminium. The J Series comes with 3, 4, 5, 6 or 8 fan units of modular design. The inlet cone
comes with rotor unit. The aerodynamically shaped outlet tube comes with built-in guide
vanes unit of Ceiling (as standard) and Closed type comply with EN 60529-1991 for finger
proof protection and to give maximum air performance at low noise and a smooth velocity
profile. Each individual motor unit/outlet tube can be easily removed to facilitate routine
servicing. Therefore, it is not necessary to dismount the entire fan from the ceiling for revision or
maintenance purpose.
• Wire Guard Protective screen:
Ceiling as standard and Closed type screen
is fiited to the motor side as per customer's
request. The Closed type screen comply with
EN 60529-1991 for finger proof protection. The
screen shall be of low carbon steel wire or rod
with powder coating.
Closed type screen Ceiling type screen
• Airflow direction:
Discharge vanes allow the adjustment of the airflow in 8 directions to match the mounting
brackets at various angles.
Page 4
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
• Performance Test:
Air Performance tested in accordance to AMCA 210 standard,
Sound performance tested in accordance to AMCA 300 standard,
Air Induction tested in accordance to AMCA 260 standard.
Page 5
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Technical Data
EC Motor - Power Supply 50Hz 210V ~ 260V
Page 6
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Technical Data
AC Motor - Power Supply 50Hz 210V ~ 260V
Colours available:
Black
Static Pressure
Static Pressure
80 80
0.3 0.3
60 60
0.2 0.2
40 40
0.1 0.1
20 20
0 4 3 2 1 0 0 4 3 2 1 0
• •
V [m3/h] 0 250 500 750 1000 1250 1500 V [m3/h] 0 250 500 750 1000 1250 1500 1750 2000
• •
V [m3/s] 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 V [m3/s] 0 0.1 0.2 0.3 0.4 0.5
volume air flow volume air flow
.
J9 / J9-E .
J9-ES
V [C.F.M.] 0 250 500 750 1000 1250 V [C.F.M.] 0 100 200 300 400 500 600 700
Δpst ρ = 1.2 kg/m3 Δpst ρ = 1.2 kg/m3
120 40
Static Pressure [Pa]
Static Pressure
1=T 1 =H
[in.WG]
[in.WG]
2=H 2 =L 0.15
3=M
4=L 35
100 0.4
0.125
30
80
0.3 25 0.1
60 20
0.075
0.2
15
40
0.05
10
0.1
20
0.025
5
. 0 4 3 2 1 0 2 1
. 0 0
V [m3/h] 0 500 1000 1500 2000 2500 V [m3/h] 0 200 400 600 800 1000 1200
.
V [m3/s] 0 0.1 0.2 0.3 0.4 0.5 0.6 .
V [m3/s] 0 0.05 0.1 0.15 0.2 0.25 0.3
volume air flow Volume air flow
Static Pressure
80 80
0.3 0.3
60 60
0.2 0.2
40 40
0.1 0.1
20 20
0 1 2 3 4 0 0 1 2 3 4 0
V• [m3/h] 0 500 1000 1500 2000 2500 3000 V• [m3/h] 0 500 1000 1500 2000 2500 3000 3500 4000
V• [m3/s] 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 V• [m3/s] 0 0.2 0.4 0.6 0.8 1
volume air flow volume air flow
Page 8 Note: The test data were obtained in a laboratory accredited by AMCA for AMCA Standard 210 testing. Data are not certified by AMCA.
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Dimensions
#
Approx. 1 Meter as standard The mounting angle of the unit body can be adjusted in 8 steps.
Different wire length optional. (0°, 11.3°, 22.5°, 33.8°, 45°, 56.3°, 67.5°, 90°)
298
208
96
207
100 4 x 12.5-40
130 J15 / J15-E
206
(Examples of Closed Type)
365
L
J11 / J11-E
L1
L2
L3 J9 / J9-E / J9-ES
L4
(Examples of Ceiling Type)
Model L L1 L2 L3 L4
Size [mm] [mm] [mm] [mm] [mm]
J5 / J5-E 548 354 432 670 748
J7 / J7-E 730 535 613 851 930
J9 / J9-E / J9-ES 910 J7 / J7-E
718 798 1037 1117
J11 / J11-E 1090 899 979 1218 1298
J15 / J15-E 1452 1260 1340 1580 1660
Note: J5~15: EC motor series; J5~15-E, J9-ES: AC motor series
All A/C motor operating input at design condition shall be added with safety factor unless
otherwise specified.
J5 / J5-E
Page 9
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J5 / J5-E)
#
Volume = 0.38 m3 /s =1.0m/s Volume = 0.36 m3 /s Wolter J5
Speed T1 = 2260 [1/min]
Speed
=0.5m/s
Speed 2 = 2160 [1/min]
Speed H
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter
Page 10
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J7 / J7-E)
#
Volume = 0.50 m3 /s =1.0m/s Volume = 0.48 m3 /s Wolter J7
Speed T1 = 2260 [1/min]
Speed
=0.5m/s
Speed 2 = 2160 [1/min]
Speed H
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter
Page 11
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J9 / J9-E)
#
Volume = 0.62 m3 /s =1.0m/s Volume = 0.59 m3 /s Wolter J9
Speed T1 = 2260 [1/min]
Speed Speed H
Speed 2 = 2160 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter
Page 12
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J9-ES)
#
Volume = 0.31 m3/s =1.0m/s Volume = 0.29 m3/s
High
SpeedSpeed
H Low Speed
Speed L
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter
Page 13
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J11 / J11-E)
#
Volume = 0.74 m3/s =1.0m/s Volume = 0.71 m3/s Wolter J11
Speed T
Speed 1 = 2260 [1/min] Speed H
Speed 2 = 2160 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter
Page 14
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J15 / J15-E)
#
Volume = 0.99 m3/s =1.0m/s Volume = 0.94 m3/s Wolter J15
Speed T
Speed 1 = 2260 [1/min] Speed H
Speed 2 = 2160 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
4 4
3 3
2 2
1 1
0 0
1 1
2 2
3 3
4 4
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
0 0
4 4
3 3
2 2
1 1
0 0
1 1
2 2
3 3
4 4
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter
Page 15
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Wolter Sales Network
Inland Poland: Hongkong:
Ing. Günther Rößler Wentoprodukt Wolter Asia Ltd.
D-07619 Schkölen 44-100 Gliwice Hong Kong
Tel. (+49) 03 66 94 / 22 359 Tel. (+48)32 331-34-24 Tel. (+852) 0 24 / 56 01 98
Fax (+49) 03 66 94 / 22 357 Fax (+48)32 729-76-53 Fax (+852) 0 24 / 56 02 90
guenther.roessler@wolterfans.de biuro@wentoprodukt.pl info@wolter.com.hk