Wolter Induction Fans.

The innovation in compartment ventilation.

Air in Motion.
Wolter Fans.

A08.5 #
Air in Motion. Wolter Fans. #
Wolter EC Induction Fans -

Closed Type
Ceiling Type

Alternative to conventional wall mounted oscillating fans and ducted


ventilation system in both open and enclosed areas. Reducing energy
cost by nearly 60% compared to conventional motors.

Application
In the context of a ductless Impulse Ventilation system, the architecture of a compartment itself serves
as the air duct. Air velocities are much lower and there is no resistance caused by a ducted system.
The total amount of energy consumed by an Impulse Ventilation system is therefore comparatively low.
More importantly, in enclosed areas, the induction effect of the Wolter Induction fans creates a
constant movement of air from the supply to the exhaust points, keeping CO levels to a minimum.
A well-designed distribution of such induction fans throughout the compartment will prevent the
accumulation of exhaust fumes in dead spots. The high velocity air stream along the ceiling level will
induce a low-velocity airstream at floor level, ensuring the required mixing of low-level and high-level
atmosphere.
Wolter Induction fans are ideal for use in underground car parks, passage ways, garages, warehouses
and workshops.

Advantages
The induction fans, allow
• Uniform air distribution and no dead spots.
• Better air quality, expel stagnant, dirty exhaust gas
and hot air
• Capital cost of the induction fan system is
outweighed by potential savings over the
traditional ducted system. ie costly installation of
ductwork becomes obsolete

• Effective cooling by inducing 120% more air then normal fans


• High efficiency resulting in energy savings and fast amortization.
• Long service life and robust design
• Flexible installation and complementary with existing ductwork system
• Virtually “maintenance-free”, minimal or no maintenance cost
Page 2
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Wolter Induction Fan
As opposed to conventional ventilation concepts
based on transverse ventilation and ducted sys-
tems, the induction fan technology is derived from
the longitudinal ventilation systems found in most
recent innovative ventilation system.
Here, a stream of air is injected into space by a
series of free-blowing family of induction axial fans,
thus inducing an air movement in addition to the
natural ventilation. The decisive parameters of ca-
pacity are the air volume and velocity.
By installing an adequate number of induction fans
in an enclosed compartment or car park, a constant The high velocity air stream along the ceiling level
air-movement can be created ensuring that the CO will induce a low-velocity airstream at floor level,
concentrations all over the areas are maintained in ensuring the required mixing of low-level and
line with building regulations. high-level atmosphere.

Computational-Fluid-Dynamics
Design
The initial step in the design of induction fan ven-
tilation system should always be a careful analysis
of the air distribution and ventilation situation
based on thorough CFD design.
CFD simulation uses purpose-built software
that allows us to create a 3-dimensional image
of the compartment or car park. After determi-
ning all relevant parameters such as required
air-change rates, volume and air flow direction,
the different ventilation scenarios can be studied
taking into account all of the above factors. The
number, size and positioning of induction fans
can then be optimised. CFD software visualizes
direction vectors of airflows and mean age of air
distribution in all areas of the compartment or
underground car park. CFD design can also be
used to simulate the fume distribution throughout
the compartment and the induction fans can be
positioned accordingly.
WOLTER will be happy to assist you early during
the design stage of your induction ventilation
project.

Page 3
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Wolter Induction Fan
Manufactured to cover all profile requirements in relevant specifications and incorporated with high
efficient motors that are generally maintenance-free.
Beside the existing A/C E series, a new registered design feature of the WOLTER EC Induction Fan
helps reduce energy costs by nearly 60% compare to conventional motor. Moreover, it allows a 120%
increase in the amount of airflow through induction to guarantee ventilation in every corner of the area.

Technical Information
• Impeller:
Impellers of high quality aluminum sheet with fixed pitch angle. They are class Q2.5 balanced in
accordance with VDI 2060 / ISO1940/1-1986.
• EC Motor / Isolator Switch:
The unit comes with a number of motorized impellers to give a high volume flow and induction
capability. Mounted with wire guard and equipped with 2/4 different speeds to suit the
respective site requirements in unidirectional airflow direction. Four speed type as optional.
Motors are connected to an external terminal box. Protection class E is IP55 according to
IEC34-5 with 1/3 of the heat loss compared to those normally incurred by a conventional AC or
3-phase motor. Each induction fan unit has a starting current lower than 1A under high speed
mode.
• Housing:
The low profile fan housing of the induction fan is manufactured as one integral unit to minimise
headroom obstruction. The overall low profile height of the unit is 298 mm. They do not
significantly obstruct headroom heights within the compartment or car park space. Isolator
switches, speed control, alarm function, lockable isolator switch can be fitted as optional extras.
• Fan inlet cone and outlet tube:
The inlet cone and outlet tube are manufactured from precision injection-moulded casted
aluminium. The J Series comes with 3, 4, 5, 6 or 8 fan units of modular design. The inlet cone
comes with rotor unit. The aerodynamically shaped outlet tube comes with built-in guide
vanes unit of Ceiling (as standard) and Closed type comply with EN 60529-1991 for finger
proof protection and to give maximum air performance at low noise and a smooth velocity
profile. Each individual motor unit/outlet tube can be easily removed to facilitate routine
servicing. Therefore, it is not necessary to dismount the entire fan from the ceiling for revision or
maintenance purpose.
• Wire Guard Protective screen:
Ceiling as standard and Closed type screen
is fiited to the motor side as per customer's
request. The Closed type screen comply with
EN 60529-1991 for finger proof protection. The
screen shall be of low carbon steel wire or rod
with powder coating.
Closed type screen Ceiling type screen
• Airflow direction:
Discharge vanes allow the adjustment of the airflow in 8 directions to match the mounting
brackets at various angles.
Page 4
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
• Performance Test:
Air Performance tested in accordance to AMCA 210 standard,
Sound performance tested in accordance to AMCA 300 standard,
Air Induction tested in accordance to AMCA 260 standard.

AXV Axial Fan to supplement Main Exhaust and


Supply Fans
The induction fan in operation provides sufficient airflow at longitudinal di-
rection in series thus this guaranteed the exhaust fumes are directed to the
nearest exhaust point located with the Main Exhaust fan. Adequately sized
main exhaust fans are therefore an important part of the overall system.
Where the natural air supply is insufficient, supply fans may have to be
installed.

Sensor and Control Technology


The sensor and control technology is a very important integral part of the
induction fan system. The requirement for CO-sensors in a compartment
or car park has to be individually determined during the design stage. The
exhaust flow and running pattern also have to be carefully designed in order
to determine exactly which fans have to be put in a specific area. Some fans
can serve as standby units only and can be started automatically if certain
maximum levels of air pollution are exceeded. EC motors can be designed to
offer certain additional functions such as open or closed loop speed control,
alarm function etc.

Page 5
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Technical Data
EC Motor - Power Supply 50Hz 210V ~ 260V

Fan Running Starting Volume Velocity at Velocity at Sound


Model Power Weight
Speed Current Current Flow Max Volume Free Flow Pressure
Size [-] [W] [A] [A] [m3/h] [m/s] [m/s] [dB(A)] [kg]
T 46 0,35 0,56 1360 10,1 9,21 54 ~ 56
H 41 0,31 0,49 1310 9,74 8,85 52 ~ 55
J5 11
M 27 0,22 0,34 1170 8,32 7,56 50 ~ 52
L 20 0,16 0,26 1010 7,32 6,65 46 ~ 48
T 62 0,47 0,74 1820 10,1 9,21 55 ~ 57
H 54 0,41 0,65 1750 9,74 8,85 53 ~ 56
J7 14
M 36 0,29 0,46 1570 8,32 7,56 51 ~ 53
L 26 0,22 0,34 1350 7,32 6,65 46 ~ 48
T 77 0,58 0,93 2230 10,1 9,21 58 ~ 60
H 68 0,51 0,81 2140 9,74 8,85 56 ~ 59
J9 17
M 45 0,36 0,57 1900 8,32 7,56 54 ~ 56
L 33 0,27 0,43 1660 7,32 6,65 49 ~ 51
T 92 0,70 1,12 2670 10,1 9,21 61 ~ 63
H 81 0,61 0,98 2560 9,74 8,85 59 ~ 62
J11 20
M 54 0,43 0,68 2280 8,32 7,56 57 ~ 60
L 39 0,33 0,52 1990 7,32 6,65 52 ~ 54
T 123 0,93 1,49 3560 10,1 9,21 64 ~ 66
H 108 0,81 1,30 3420 9,74 8,85 63 ~ 65
J15 27
M 71 0,58 0,91 3040 8,32 7,56 60 ~ 62
L 52 0,44 0,69 2650 7,32 6,65 55 ~ 57
Note: 1, The volume flow indicated above is measured in chamber at 0 static pressure, other values are measured at free flow;
2, The sound pressure dB(A) is measured at the distance of 1,5m at 45 degree from the outlet;
3, Fan speed T as option.
4, T = 2260 rpm, H = 2160 rpm, M = 1850 rpm, L = 1600 rpm.

Page 6
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans. #
Technical Data
AC Motor - Power Supply 50Hz 210V ~ 260V

Fan Power Running Starting Volume Velocity at Velocity at Sound


Model Weight
Speed Current Current Flow Max Volume Free Flow Pressure
[-] [W] [A] [A] [m3/h] [m/s] [m/s] [dB(A)] [kg]
H 90 0,40 0,65 1360 9,21 8,38 54 ~ 56
J5-E 11
L 66 0,34 0,53 1047 6,94 6,25 47 ~ 49
H 120 0,53 0,84 1820 9,21 8,38 55 ~ 57
J7-E 14
L 88 0,46 0,60 1405 6,94 6,25 48 ~ 50
H 150 0,66 1,06 2230 9,21 8,38 58 ~ 60
J9-E 17
L 110 0,57 0,73 1700 6,94 6,25 51 ~ 53
H 70 0,30 0,48 1120 5,20 4,70 45 ~ 48
J9-ES 17
L 55 0,25 0,39 1032 4,80 4,30 43 ~ 46
H 180 0,79 1,26 2670 9,21 8,38 61 ~ 63
J11-E 20
L 132 0,68 1,07 2040 6,94 6,25 54 ~ 56
H 240 1,06 1,70 3560 9,21 8,38 64 ~ 66
J15-E 27
L 176 0,91 1,46 2720 6,94 6,25 57 ~ 59
Note: 1, The volume flow indicated above is measured in chamber at 0 static pressure, other values are measured at free flow;
2, The sound pressure dB(A) is measured at the distance of 1,5m at 45 degree from the outlet;
3, H = 2300 rpm, L = 1700 rpm for J-E series, H = 1410 rpm, L = 1320 rpm for J9-ES;
4, * All ES - A/C motor operating input at design condition shall be added with safety factor unless otherwise specified.

Colours available:

Black

Milk White Grey


Page 7
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Performance curves
#

J5 / J5-E •
J7 / J7-E
V [C.F.M.] 0 100 200 300 400 500 600 700 800 V [C.F.M.] 0 200 400 600 800 1000
pst ρ = 1.2 kg/m3 pst ρ = 1.2 kg/m3
120 120

Static Pressure
Static Pressure

1=T [in.WG] 1=T [in.WG]


2=H 2=H
3=M 3=M
4=L 4=L
100 0.4 100 0.4

80 80
0.3 0.3

60 60
0.2 0.2
40 40

0.1 0.1
20 20

0 4 3 2 1 0 0 4 3 2 1 0
• •
V [m3/h] 0 250 500 750 1000 1250 1500 V [m3/h] 0 250 500 750 1000 1250 1500 1750 2000
• •
V [m3/s] 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 V [m3/s] 0 0.1 0.2 0.3 0.4 0.5
volume air flow volume air flow

.
J9 / J9-E .
J9-ES
V [C.F.M.] 0 250 500 750 1000 1250 V [C.F.M.] 0 100 200 300 400 500 600 700
Δpst ρ = 1.2 kg/m3 Δpst ρ = 1.2 kg/m3
120 40
Static Pressure [Pa]
Static Pressure

1=T 1 =H

[in.WG]
[in.WG]
2=H 2 =L 0.15
3=M
4=L 35
100 0.4
0.125
30
80
0.3 25 0.1

60 20
0.075
0.2
15
40
0.05
10
0.1
20
0.025
5

. 0 4 3 2 1 0 2 1
. 0 0
V [m3/h] 0 500 1000 1500 2000 2500 V [m3/h] 0 200 400 600 800 1000 1200
.
V [m3/s] 0 0.1 0.2 0.3 0.4 0.5 0.6 .
V [m3/s] 0 0.05 0.1 0.15 0.2 0.25 0.3
volume air flow Volume air flow

J11 / J11-E J15 / J15-E


• •
V [C.F.M.] 0 250 500 750 1000 1250 1500 1750 V [C.F.M.] 0 250 500 750 1000 1250 1500 1750 2000 2250

pst  = 1.2 kg/m3 pst  = 1.2 kg/m3


120 120
Static Pressure

Static Pressure

1=T [in.WG] 1=T [in.WG]


2=H 2=H
3=M 3=M
4=L 4=L
100 0.4 100 0.4

80 80
0.3 0.3

60 60
0.2 0.2
40 40

0.1 0.1
20 20

0 1 2 3 4 0 0 1 2 3 4 0
V• [m3/h] 0 500 1000 1500 2000 2500 3000 V• [m3/h] 0 500 1000 1500 2000 2500 3000 3500 4000

V• [m3/s] 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 V• [m3/s] 0 0.2 0.4 0.6 0.8 1
volume air flow volume air flow
Page 8 Note: The test data were obtained in a laboratory accredited by AMCA for AMCA Standard 210 testing. Data are not certified by AMCA.

Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Dimensions
#
Approx. 1 Meter as standard The mounting angle of the unit body can be adjusted in 8 steps.
Different wire length optional. (0°, 11.3°, 22.5°, 33.8°, 45°, 56.3°, 67.5°, 90°)

298

208
96

207

100 4 x 12.5-40
130 J15 / J15-E

206
(Examples of Closed Type)

365
L
J11 / J11-E

L1
L2
L3 J9 / J9-E / J9-ES
L4
(Examples of Ceiling Type)
Model L L1 L2 L3 L4
Size [mm] [mm] [mm] [mm] [mm]
J5 / J5-E 548 354 432 670 748
J7 / J7-E 730 535 613 851 930
J9 / J9-E / J9-ES 910 J7 / J7-E
718 798 1037 1117
J11 / J11-E 1090 899 979 1218 1298
J15 / J15-E 1452 1260 1340 1580 1660
Note: J5~15: EC motor series; J5~15-E, J9-ES: AC motor series
All A/C motor operating input at design condition shall be added with safety factor unless
otherwise specified.
J5 / J5-E

Page 9
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J5 / J5-E)
#
Volume = 0.38 m3 /s =1.0m/s Volume = 0.36 m3 /s Wolter J5
Speed T1 = 2260 [1/min]
Speed
=0.5m/s
Speed 2 = 2160 [1/min]
Speed H
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0

Volume = 0.32 m3 /s =1.0m/s Volume = 0.28 m3 /s Wolter J5


Speed M
Speed 3 = 1850 [1/min] Speed L4 = 1600 [1min]
Speed
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter

Page 10
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J7 / J7-E)
#
Volume = 0.50 m3 /s =1.0m/s Volume = 0.48 m3 /s Wolter J7
Speed T1 = 2260 [1/min]
Speed
=0.5m/s
Speed 2 = 2160 [1/min]
Speed H
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0

Volume = 0.43 m3 /s =1.0m/s Volume = 0.37 m3 /s Wolter J7


3 = 1850 [1/min]
Speed M Speed L4 = 1600 [1min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter

Page 11
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J9 / J9-E)
#
Volume = 0.62 m3 /s =1.0m/s Volume = 0.59 m3 /s Wolter J9
Speed T1 = 2260 [1/min]
Speed Speed H
Speed 2 = 2160 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0

Volume = 0.52 m3 /s =1.0m/s Volume = 0.46 m3 /s Wolter J9


Speed M
Speed 3 = 1850 [1/min] Speed L4 = 1600 [1min]
Speed
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter

Page 12
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J9-ES)
#
Volume = 0.31 m3/s =1.0m/s Volume = 0.29 m3/s
High
SpeedSpeed
H Low Speed
Speed L
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter

Page 13
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J11 / J11-E)
#
Volume = 0.74 m3/s =1.0m/s Volume = 0.71 m3/s Wolter J11
Speed T
Speed 1 = 2260 [1/min] Speed H
Speed 2 = 2160 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0

Volume = 0.62 m3/s =1.0m/s Volume = 0.55 m3/s Wolter J11


Speed 3 = 1850 [1/min]
Speed M Speed L4 = 1600 [1min]
Speed
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

3 3
2 2
1 1
0 0
1 1
2 2
3 3
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter

Page 14
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Air in Motion. Wolter Fans.
Air Velocity Profile (J15 / J15-E)
#
Volume = 0.99 m3/s =1.0m/s Volume = 0.94 m3/s Wolter J15
Speed T
Speed 1 = 2260 [1/min] Speed H
Speed 2 = 2160 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

4 4
3 3
2 2
1 1
0 0
1 1
2 2
3 3
4 4
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
0 0

Volume = 0.83 m3/s =1.0m/s Volume = 0.74 m3/s Wolter J15


Speed M
Speed 3 = 1850 [1/min] Speed L
Speed 4 = 1600 [1/min]
=0.5m/s
=0.3m/s
Plan View Plan View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

4 4
3 3
2 2
1 1
0 0
1 1
2 2
3 3
4 4
Side View Side View
0 5 10 15 20 25 30 0 5 10 15 20 25 30

8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
0 0
Scale in Meter

Page 15
Wolter GmbH
Maschinen- und Apparatebau KG
Am Wasen 11 • D-76316 Malsch • Tel. (+49)07204/9201-0 • Fax: (+49)07204/9201-11
Wolter Asia Ltd.
Unit 12, 2/F., Kin Fat Industrial Centre.,13 Kin Fat Street, Tuen Mun, N.T. Hong Kong. Tel. +(852) 24560198 • Fax +(852) 24560290
Wolter Sales Network
Inland Poland: Hongkong:
Ing. Günther Rößler Wentoprodukt Wolter Asia Ltd.
D-07619 Schkölen 44-100 Gliwice Hong Kong
Tel. (+49) 03 66 94 / 22 359 Tel. (+48)32 331-34-24 Tel. (+852) 0 24 / 56 01 98
Fax (+49) 03 66 94 / 22 357 Fax (+48)32 729-76-53 Fax (+852) 0 24 / 56 02 90
guenther.roessler@wolterfans.de biuro@wentoprodukt.pl info@wolter.com.hk

Mattias Industrievertretungen Portugal: India:


D-16259 Bad Freienwalde Safe Park Ventilação Industrial Lda. Wolter Ventilators India Pvt. Ltd.
Tel. (+49)03344/301994 P-2675-240 Odivelas 867 D, Block-A, Sushant Lok, Phase-I,
Fax (+49)03344/301996 Tel. (+351) 21 93 / 75 265 Gurgaon - 122009 (Haryana)
thomas.mattias@wolterfans.de Fax (+351) 21 93 / 86 061 Tel. +91 124 2577797, 4261001-3
safepark@netcabo.pt sales@wolterindia.in
Industrieservice Drexler
D-49080 Osnabrück Russia: Indonesia:
Tel. (+49) 0 541 / 20 04 88 3
Euroclimat-Prof PT. Agung Kipas Kastara.
Fax (+49) 0 541 / 20 04 88 4
RU-107082 Moskau ID-14440 Jakarta Indonesia
wolfgang.drexler@wolterfans.de
Tel. (+7) 4 95 / 97 57 530 Tel. +62 (0) 21 / 6667 6925, 6667 6926
Burkhardt Projekt GmbH Fax (+7) 4 95 / 97 57 530 Fax +62 (0) 21 / 6667 6927
D-67583 Guntersblum gso@euroclimat.ru indowolter@cbn.net.id
Tel. (+49) 0 62 49 / 82 01 Korea:
Schweiz:
Fax (+49) 0 62 49 / 88 58
info@bp-wolter.de Anson AG Zürich Kaceco-Wolter
CH-8055 Zürich 14-1, Dang-dong,Gunpo-shi, Gyeonggi-do
Friedrich Glock Tel. (+41) 0 44 / 46 11 111 Tel. +82 (0) 31 / 4773 104
D-97980 Bad Mergentheim Fax (+41) 0 44 / 46 13 111 Fax +82 (0) 31 / 4773 132
Tel. (+49) 0 79 31 / 37 44 info@anson.ch wolter@kaceco.com / info@kaceco.com
Fax (+49 )0 79 31 / 28 58
Ventra Technik AG Malaysia:
friedrich.glock@wolterfans.de
CH-8599 Salmsach
Tel. (+41) 0 71 / 46 11 447 Vibrantech (M) Sdn Bhd.
Europe Fax (+41) 0 71 / 46 11 448 47200 Petaling Jaya Selangor, Malaysia
ventra@bluewin.ch Tel. +603 (0) 7847 3500
Danmark: Fax +603 (0) 7847 3380
Air-Con Danmark A/S Turkey: sales@vibrantech-sb.com
DK-8400 Ebeltoft Air Trade Centre Ltd Sti Türkiye,
Tel. (+45)086/345111 Singapore:
TR-34418 Seyrantepe / Instanbul
Fax (+45)086/345810 Tel. (+90) 02 12 / 28 34 510 Wolter Pte. Ltd.
jbj@air-con.dk Fax (+90) 02 12 / 27 83 964 SG-569738 Singapore
atc.turkey@airtradecentre.com Tel. (+65) 0 63 / 52 95 48
Hungary: Fax (+65) 0 63 / 52 95 47
Air-Technik Légtechnikal Kft. United Kingdom: info@wolterfans.com.sg
HU-2040 Budaörs Wolter UK Ltd.
Tel. (+36)023/428533 Sri Lanka:
GB-B37 7UQ Solihull
Fax (+36)023/428544 Tel. (+44) 01 21 / 63 55 390 Sirocco Air Technologies (Pvt) Ltd.
bp.air-technik@troges.hu Fax (+44) 01 21 / 63 55 391 28/12, Gemunu Mawatha, Kotuwegoda,
info@wolteruk.com Rajagiriya, Sri Lanka
Ireland: Tel. +94 11 7 392 010
Finheat Ltd. Middle East and North Africa Fax +94 11 7 392 015
IE-Dublin 12, Walkinstown suren@sairt.com
Tel. (+353)01/4564066 Egypt:
Fax (+353)01/4564071 Tiba Engineering Industries Co. Taiwan:

  Nasr City, Cairo Waxlink International Co., Ltd.
Tel. (+2) 02 / 40 22 866 8F No. 218 Roosevelt Rd., Sec. 6
Lithuania: Fax (+2) 02 / 40 44 771 Taipei, Taiwan
JSC Saldos Prekyba tibaengineering@manz-group.com Tel. (+886) 02 / 89 32 11 96
LT-78109 Siauliai Fax (+886) 02 / 89 32 11 97
Tel. (+37)041/540212 Israel: waxlink.tech@msa.hinet.net
Fax (+37)041/596176 Lea Ventilation Industries Ltd.
prekyba@salda.lt IL-27113 Kiriyat-Bialik, Israel Thailand:
Tel. (+972) 0 48 / 76 23 57 Wolter Ventilation Co., Ltd.
Netherlands: Fax (+972) 0 48 / 76 20 51 Thamai Kratumban Samutsakorn 74110
AirFan B. V. mail@lea.co.il Thailand
NL-7442 CX Nijverdal Tel. +66 (0) 3486 6555
Tel. (+31)054/8366366 United Arab Emirates, Kuwait, Fax +66 (0) 3486 6599
Fax (+31)054/8365320 Lebanon: natiphan@wolterfan.com
ventilatie@airfan.nl Wolter Ventilation LLC
Energy International Australia
Rucon B. V. Ventilatoren P.O. Box 3562 Sharjah, UAE
NL-3840 AG Harderwijk Tel. (+971) 06 / 53 43 477 The Sydney Fan Company.
Tel. (+31)034/1411670 Fax (+971) 06 / 53 43 756 NSW 2147, Sydney, Australia
Fax (+31)034/1411690 energysh@emirates.net.ae Tel. +61 (0) 2 / 9624 4000
verkoop@rucon.nl
Fax +61 (0) 2 / 9624 4100
Österreich: Asia sales@thesydneyfancompany.com
Wolter Werksvertretung Österreich China Mainland:
A-4040 Linz Taizhou Wolter Ventilation Co. Ltd.
Tel. (+43) 07 32 / 75 77 07 Hengjie, Luqiao District
Fax (+43)07 32 / 75 77 07 75 Taizhou City, Zhejiang
wolter.linz@aon.at Tel. (+86) 576 / 26 22 666 (26 52 888)
Fax (+86) 576 / 26 56 830
Wolter GmbH
Maschinen-und Apparatebau KG
Am Wasen 11
D-76316 Malsch / Germany
Tel. +49 (0) 7204/9201-0
Fax +49 (0) 7204/9201-11
www.wolter.eu
info@wolter.eu

You might also like