DISOMAT® T Weigh Transmitter
DISOMAT® T Weigh Transmitter
DISOMAT® T Weigh Transmitter
3 binary inputs
Application Equipment
Designed as favourably priced solution Main board DWT 100 comprises the DISOMAT T is supplied as plug-in board
for many standard weighing tasks, the following functions: or mounted in a 19" rack or fieldbox.
DISOMAT® T Weigh Transmitter is used
as weight value transducer for weight Measuring circuit with A/D converter Appropriate designs of the DISOMAT T
value monitoring, hopper level 4 relay outputs, safety-separated are available for explosion-hazard areas
measurement and control of single- 3 binary inputs, galvanically isolated of categories 2D/3G for direct on-site
ingredient feed operations. 1 analog output installation. Weighing sensors and
Service interface displays in category 2G (zone1) are
Combined with load cells, DISOMAT T is EDP interface (various protocols) connected via the optional barrier sets
also suitable for sophisticated measuring DXB 10x.
tasks. Expansion boards provide additional The barrier sets are mounted directly into
functions: the field housings or inserted into the 19"
Used in conjunction with Schenck rack.
measuring eyes of the DMA type, the PROFIBUS interface via PROFIBUS
system is a simple and far less costly board VPB 20100
answer to applications where more DeviceNet interface via coupler
approximate measurement will suffice, board VCB 010
e.g. hopper level measurement. Display, 3 1/2-digit, 10 mm digit
height to control the scales function.
Equipped with analog output and serial 3 buttons to control the scales
interface, DISOMAT T is suitable for all function.
remote-controlled scales connected to
higher level EDP or PLC systems. The
optional display enables the weight value
to be checked locally.
BV-D2035GB 97
Functions
DISOMAT T comes with An on-line help function assists the DISOPLAN T user by providing comprehensive
various EDP protocols. In information on all important menu items.
addition, it can be integrated
into commercial fieldbus
systems (J-BUS,
PROFIBUS, DeviceNet).
98
Feeding Functions
Despite its compact design and simple parameterisation, the DISOMAT T feeding functions can be set
over a wide range.
For every ingredient to be fed, a set of material-specific data can be preset before start of feeding, e.g.
99
Housings
- DWT 100
DISOMAT T as p.c. board
- DXB 101, 102, 103
Ex-protective circuitry
- DNT 300/310, VNT 331
Power supply for 115/230 VAC
(only 1 unit per rack) Fig.2
- Dummy front panel Fieldbox DFG
- The display variant needs two
slots. 1956
Fig.5
Expansion boards:
– PROFIBUS board DPB V100
– DeviceNet board VCB010
One expansion board can be plugged
onto weigh transmitter board DWT 100.
100
DISOMAT T – Open-ended
EDP interface
101
Technical Data
Display 8 LEDs for display of: 2 serial interfaces Rear panel equipped with plug-in
– Output contact status EDP interface block terminals.
– Error message RS 232 (factory set), RS 485
– System load or 20 mA TTY pluggable to EDP,
Sending/receiving on EDP PLC, PC and serial displays.
interface Available protocols:
Load cells max. 12 x RT load cells - Siemens 3964 R
max. 4 x 350ȍ load cells - Siemens 3964 R for S5 mode
max. 4 x DMA measuring eyes - Siemens Teleperm
Load cell supply 20 and 10 V - SCHENCK Protocol in accordance
Load cell cable max. 1000 m with Spec Sheet DDP 8 785
Overvoltage ± 30 V - J-Bus (MODBUS)
protection on - Protocols for secondary displays
measuring input Service interface 9-pole SUB-D connector on front
Measuring circuit Linearity: < 0.01 % panel for connection of PC to
accuracy Range stability: ± 20 ppm/K DISOPLAN T configuration program.
Zero point stability: RS 232 with fixed parameter setting:
± 1 µV / K basic variant 9600 baud, 8 bits, even parity,
Number of increments 100 to 50,000 1 stop bit, no handshake
Measuring rate 70 measurement values/sec. Analog output 0 – 20 mA or 4 – 20 mA
Storage temperature -10° to +80°C 500 : maximum load
Operating temperature -10° to +50°C ATTENTION:
The use of the optional DISOMAT T
Sensitivity t 2 µV/d display reduces the admissible
Input signal 0.1 to 57 mV external load by 250 ohms.
Dead load signal 0 to 57 mV When connecting the analog output
Required power 18 – 36 VDC or in the hazardous area, please note
24VAC +10% –15%, the instructions given at the
47 – 63Hz Explosion Protection item.
0.63AT fusing Resolution: 10,000 increments
(0.8AT with Profibus board) Linearity 0.05% calibrated;
Power consumption apr. 10 W 1% non-calibrated.
Data backup All setting data are stored fail- Range stability: < 0.05 % / 10 K
safe in EEPROM. Zero point stability: < 0.10 % / 10 K
After power failure, DWT 100 Analog output can be assigned to
initialises and automatically the following values:
resumes operating. - Net
Zero setting function max. 20 % - Gross
Automatic zero 0.5 d/s; deselectable - dW/dt
tracking - Preset by EDP
Filter Software filter 1 to 10 sec. Analog output galvanically isolated
Line interference 90 dB, 48 to 62 Hz Binary outputs 4 relay outputs, 230 V AC/0, 1 A, or
suppression 24 V DC/0.5 A, switched as MAX or
Common mode > 110 dB MIN contact via comparators using
rejection the following selectable values:
CE conformity As per EC directives - Net
89/336 EWG - Gross
73/ 23 EWG - dW/dt
90/384 EWG Controlled directly:
- No-motion
- Tare acquired
- Preset by EDP
- Fault
- Feed control
Binary outputs galvanically isolated
and safety-separated (VDE 0160).
Binary inputs 3 inputs 24 VDC, opto-decoupled
102
Technical Data
Expansions
103
Variants Ordering Number Hazardous Area Variants Ordering Number
DWT 100 V 019323.B01 DXB 100 707041.01
DISOMAT T Weigh Transmitter, Ex-protective circuitry designed as p.c.
p.c. board including front panel board including front panel
DWT 100 - D V 008566.B01 DFG 100E 707043.04
DISOMAT T Weigh Transmitter, DISOMAT T in fieldbox DFG,
p.c. board with front panel, complete for 24VDC supply, complete with Ex-
with integral LED weight display protective circuitry
DWT 101 D 707039.02 DFG 100E - D V 008562.B 01
DISOMAT T Weigh Transmitter, DISOMAT T in fieldbox DFG,
Profibus expansion board on p.c. for 24VDC supply, complete with Ex-
board, including front panel protective circuitry and integral LED
DFG 100 D 707043.01 weight display
DISOMAT T in fieldbox DFG, DFG 101E 707043.05
for 24VDC supply DISOMAT T in fieldbox DFG,
DFG 100 - D V 008558.B 01 for 24VDC supply, complete with
DISOMAT T in fieldbox DFG, Profibus expansion board and Ex-
for 24VDC supply, complete with protective circuitry
integral LED weight display DFG 101E - D V 008564.B 01
DFG 101 D 707043.02 DISOMAT T in fieldbox DFG,
DISOMAT T in fieldbox DFG, for 24VDC supply, complete with
for 24VDC supply, complete with Profibus expansion board, Ex-
Profibus expansion board protective circuitry and integral LED
DFG 101 - D V 008560.B 01 weight display
DISOMAT T in fieldbox DFG, DFG 110E 707044.04
for 24VDC supply, complete with DISOMAT T in fieldbox DFG,
Profibus expansion board and integral complete with transformer for
LED weight display 115/230VAC supply and Ex-protective
DFG 110 707044.01 circuitry
DISOMAT T in fieldbox DFG, DFG 110E - D V 008563.B 01
complete with transformer for DISOMAT T in fieldbox DFG,
115/230VAC supply complete with transformer for
DFG 110 - D V 008559.B 01 115/230VAC supply, Ex-protective
DISOMAT T in fieldbox DFG, circuitry and integral LED weight
complete with transformer for display
115/230VAC supply and integral LED DFG 111E 707044.05
weight display DISOMAT T in fieldbox DFG,
DFG 111 707044.02 complete with transformer for
DISOMAT T in fieldbox DFG, 115/230VAC supply, Profibus
complete with transformer for expansion board and Ex-protective
115/230VAC supply and Profibus circuitry
expansion board DFG 111E - D V 008565.B 01
DFG 111 - D V 008561.B 01 DISOMAT T in fieldbox DFG,
DISOMAT T in fieldbox DFG, complete with transformer for
complete with transformer for 115/230VAC supply, Profibus
115/230VAC supply, Profibus expansion board, Ex-protective circuitry
expansion board and integral LED and integral weight display
weight display DISOPLAN T D721017.02
Adapter cable for 1 x Profibus K 006038.01 PC software for parameterisation of
connection at the 19" rack rear wall DISOMAT T, operable under
(max. 5 possible in 19" rack) WINDOWS 9x, ME, 2000, NT and XP.
Adapter cable VSC 20205 for Profibus V 031075.B01
connection of 5 DISOMAT T to a bus Please ask us for further variants.
cable e.g.:
(2 possible in 19" rack) - DFG 100 – E02
- DFG 101 – E02
- DFG 100 – E21
104