Known Parameters

Pressure before blower


Pressure after blower
Volumetric Flow after Blower
Blower power
Blower power
Density of Air before blower
Heat given by Heater
Specific Heat of air at const. Pressure

Assumed parameters
Blower efficiency
Specific heat Ratio of Air
Temperature before Blower

Calculated
Volume flow rate at blower inlet
Volume flow rate at blower inlet
Mass flow rate
Mass flow rate
Temperature at the Blower Outlet
Temperature at heater outlet
Temperature at heater outlet

Conditions for the tapped air required


Temperature
Flow rate
Pressure

COMPRESSOR
Density
Motor
Flow

Pressure
Temperature before after cooler
mass flow rate

Power req for unit mass flow rate


total power consumed for tapping air
Blower power consumption for 22 hrs
heater power consumption for 18 hrs
Total power consumption

Power consumed for 18 hrs for tapping

Total saved power


Total saved power in terms of money
P1 101325.000 Pascal
P2 106301.800 Pascal
Q2 450.000 Cubic Meters per Hour
Ẇ - blower 2.000 HP
Ẇ - blower 1491.400 Watts
ρ1 1.180 Kg/cubic meters
Ẇ - heater 25200.000 Watts
Cp 1006.000 Joules per Kg per Kelvin

η 0.700
γ 1.400
T1 298.000 Kelvin

Q1 0.128 Cubic Meters per second


Q1 461.505 Cubic Meters per Hour
ṁ 544.576 Kg/hour
ṁ 0.151 Kg/second
T2 304.843 Kelvin
T3 470.438 Kelvin
T3 197.438 Degree Celsius

Treq 197.438 Degree Celsius


ṁ req 544.5759917098 Kg/hour
Preq 106301.800 Pascals

6.48 kg/m3
132 kWatts
17.1 Cubic meters per minute
1026 Cubic meters per Hour
8.5 kg per sq cm
175 deg C
6648.48 kg/hr

0.0198541622 kWhr/kg
10.8121000448 kw
32.8108 kwh
453.6 kwh
486.4108

237.87 kwh

248.54 kwh
1118.4506955671 Rs