Protection, control
and monitoring
For transmission lines, substations,
railways, power generation & renewables.

• Advanced protection,
control and monitoring solutions
• At the forefront of IEC 61850
technology
• Future proof applications meeting
digital substation requirements
2 D I G I TA L S U B S TAT I O N 3

— —
Power and automation technology Table of contents
solutions from ABB support the digital
transformation of your business from the
field to the boardroom and everywhere
in between. These solutions enable deep
insight into the power network, asset
004 – 009 Power infrastructure
performance management, energy Substation and Grid evolution.
efficiency and reduced operating costs. Main challenges and expectations.

010 – 011 Relion® 670 & 650 series –


Intelligent Electronic Devices (IEDs)
ABB’s protection, control and The power of one offering for protection and control.

monitoring portfolio provides Relion 670 and 650 series.

012 – 019 Line protection solutions


interoperable and reliable solutions Overhead lines and cables:
enabling a smarter, sustainable and REL670, REL650, RED670, RED650.

future proof power system. 020 – 029 Substation solutions


Circuit breakers: REQ650.
Control applications: REC670, REC650.
Transformers: RET670, RET650.
Busbars: REB670, REB650, REB500.
Phasor measurement units: RES670.

030 – 033 Railway solutions


RER670.

034 – 037 Power generation and renewables solutions


Generators: REG670.

038 – 043 Software engineering tools


PCM600, IET600, ITT600.
4 R e l i o n ® p r ot e c t i o n a n d c o n t r o l P o w er i n fr a str u ct u re 5


Substation evolution.
From electro-mechanical

01 Classical Conventional ABB Ability Digital

relays to digital substation.


Network
Evolution continues. level Network Network ABB Ability Network Management
Management Management & Asset Performance Management

Serial Communication Ethernet Communication MPLS-TP


— The main objective of the utilities is to provide New challenges are arising for the customers,
01 Substation evolution
from classical to affordable electric power of a good quality, and it is the manufacturers task to facilitate
ABB Ability Digital continuously and preferably for profit. usability of the equipment, in order to leverage
Substation
the maximum of all assets in the power system.
Reliability of the power system protection, as Station
well monitoring, control and asset management Digital substation is the way forward. level
have significantly improved from the early
HMI + Control Board / Event Recording HMI Gateway HMI Gateway
days of electromechanical relays to modern
IEDs - leading to higher availability.

Copper Cables IEC 61850 IEC 61850

Bay
level
Hard-wired Protection & Control Protection and control IEDs Protection and control IEDs

Copper Cables Copper Cables IEC 61850

Conventional Conventional Process interface units in


Marshalling Cubicle marshaling cubicle digital marshaling cubicle

Process
level
Copper Cables and Fibre

Conventional AIS bay Conventional AIS bay DCB with FOCS and Motor Drive
6 R e l i o n ® p r ot e c t i o n a n d c o n t r o l P o w er i n fr a str u ct u re 7


Grid evolution.
Changes in the grid
topology and business model.
Trends in modern power grids.

— The trends that are having impact on The requirements and expectations on
02 Traditional and
modern day grid transmission grid technology: substation protection and control will
• Renewable penetration increase. Evolving grids have direct impact
• HVDC on protection and control systems.
• FACTS
• Phase-shifting transformers
• Micro-grids
• Nano-grids
• Electrical mobility
• Charging infrastructure for electric vehicles
• Digital transformation of transportation
• Digitalization of power grids

— Traditional grid Modern day grid


02
8 R e l i o n ® p r ot e c t i o n a n d c o n t r o l 9


Evolving grid and substation.
Main challenges and expectations.
Requirements for a modern grid.

— —
Fundamental requirements Cyber
on protection and Security
control IEDs • User access control
• Secure communication
• High reliability
• Protocol hardening
• High availability
• Security logging
• High operational performance
• Patch management
• User friendliness and safety
• Cost effectiveness
• Interoperability

— —
Product related Life cycle
expectations requirements
• Scalability • Safeguard investment
• Flexibility and robustness over the entire life cycle
• Ability to facilitate conventional • Backward compatibility
to digital substation transition
10 R e l i o n ® p r ot e c t i o n a n d c o n t r o l P o w er i n fr a str u ct u re 11

— —
Relion® the power of one solution. Relion 670 and 650 series.
For protection, control and monitoring. The power of one.
To cope with any situation, a modern protection IED needs ABB’s high performing series of
to be configurable to fit within its intended application area. intelligent electronic devices (IEDs)
ABB’s solution to this requirement is the Relion® series of IEDs.

The Relion series offers a standardized library network. And in the smart grid, information is


of functionality on a high performance, common of vital importance, so advanced and accurate
hardware architecture, and provides the flexibility PMU (phasor measurement unit) functionality
03 Relion 670 Family
Relion 670 series

and configurability to suit any application area. will present you with the information you 04 Relion 650
• A flexible solution for every application
need to make your smart grid truly smart.
• Support for the most demanding requirements
The Relion series of devices cover the
of protection and control applications
complete protection, control and monitoring With its proven reliability, high accuracy and
• Ordering as pre-configured or customized
needs of your power infrastructure. high performance operation, the Relion family
- Three different hardware casings
devices can be used for the most demanding
(1/1, 3/4 and 1/2 19”)
Advanced control capabilities and system applications for your power system network.
- Advanced protection and control features
modeling, according to IEC 61850 will give you
- Multiple objects
new ways to design and dynamically operate your — - High level of functional integration
03

One common platform Flexibility


• For any type of application the platform • Functional specification – cost effective way
remains the same of selecting only the required functions
• Learn it once, use it many times • Functional integration —
• A type tested platform – time saving -- The same number of functions in fewer IEDs
• Substantial reduction in spare parts reduces cost and improves safety.
Relion 650 series
• Solution for the most common requirements of
protection and control
• Pre-defined, ready-to-use solutions for all
application areas
• Simple ordering, ready made applications for all
application areas
- Single breaker applications
Scalability Communication, - One hardware casing (1/2 19”)
• Hardware scalability to meet security and conformity - Always pre-configured
the demands of the application • Interoperability - IEC 61850 - Few additional options
• I/O scalability offers cost effectiveness • Security - NERC CIP and IEC 62351-8 —
04
• Modularity • Operational performance -
IEC 60255-1 and IEEE C37.90
• Testing beyond the standards
12 R e l i o n ® p r ot e c t i o n a n d c o n t r o l L i n e protectio n 13


Relion® the power of one solution.
For line protection.
— —
Overhead lines and cables tie the electrical grid together. Cables Overhead lines
Overhead lines are exposed and particularly vulnerable to All encompassing application Applicable for all kinds of lines
everything from bad weather to flora and fauna. across short high-voltage including long, extremely high-voltage
underground cable link traversing series compensated overhead lines
a waterway to a combination deployed in rough challenging terrain.
of cable and overhead line.

It is an accident of geography that many power


generation sites are situated far from the centers
of power consumption, which means
efficient ways of transporting large
amounts of electricity over longer and
longer distances is critically important.

Increasing voltage, reducing reactance


and building more parallel lines using AC
transmission is one answer. As primary power
systems become more technically complex,
secondary systems must keep up with
improved algorithms, enhanced performance
and rigorous control capability in order to
ensure network stability and continuity.

From long, extremely high-voltage series


compensated overhead lines deployed in
rough, rural terrain to a short high-voltage
underground cable link traversing a waterway,
ABB grid automation has a protection solution
for any line application, supported by 100
years of practical, real world experience.
14 R e l i o n ® p r ot e c t i o n a n d c o n t r o l L i n e protectio n 15


Line protection solutions.
Relion® REL670, REL650, RED670 and RED650
Distance protection offers extensive protection
application opportunities for overhead lines and cables,
or combinations of overhead lines and cables.


05 Line protection
Differential protection is easier An alternative principle for line protection that
performance is quickly becoming the norm is differential
characteristics to integrate and delivers more protection. Differential protection is based on
consistent performance compared Kirchhoff’s laws, stating that all current into
a network node shall add up to zero in an
to distance protection, at the cost ideal system. What this practically means
of an increased hardware and for a line protection application is that the
current that is measured to flow into the line
communication dependency. should also be measured to come out.

Differential protection is easier to integrate into


Distance protection is and remains by far the
a protection philosophy than distance
main protection principle for overhead lines and
protection, as it is a unit protection. It delivers
cables. It is reliable, fast and largely manages to
more consistent performance, at the cost of
eliminate the variable system quantities of load
an increased hardware and communication
and supply out of the protection calculation.
dependency. Some form of high bandwidth,
low latency communication is required in
Distance protection is in its core an
between the line ends to exchange analog
impedance measurement, comparing
information for the line differential algorithm
a known line impedance against a
to process. Typically, this is a direct fiber optic
measured system impedance.
cable, but communication over MPLS-TP, SDH,
PDH or SONET network is also possible.
A modern distance protection IED (Intelligent
Electronic Device) must deal with many
Relion RED670 and RED650 offer either a
more features though; phase selection,
dedicated line differential protection IED, or a so
load encroachment, power swing detection,
called multi-function device, whereby distance —
REL670 REL650 RED670 RED650
scheme communication, phasor measurement, 05
protection is integrated in the same IED as well.
monitoring, control and backup protection – a Distance protection
wide variety of tasks are performed, differing Speed < 1 cycle 1 1/2 cycle < 1 cycle 1 1/2 cycle
from installation to installation and customer Power swing blocking
to customer. Additional functions Out of step and pole slip detection
Phase preference logic

Relion REL670 and REL650 offer line distance Series compensated lines X Not available X Not available

protection. REL670 offers pre-configured Differential protection


solutions while it is also a highly configurable Speed < 1 cycle 1 1/2 cycle
device that delivers superior protection, control Maximum line ends 5 3
and monitoring in any high-voltage application; In-zone transformer X X
Not available
REL650 provides a pre-defined, pre- Short range communication to multiplexer X X
configured variant with a small form Communication speed 64 kbit/s or 2 Mbit/s 64 kbit/s
factor and standardized solution. Direct fiber communication range Up to ~ 130 km Up to ~ 60 km
16 R e l i o n ® p r ot e c t i o n a n d c o n t r o l L i n e protectio n 17


Line distance protection.
Relion® REL670 and REL650
Line distance protection offers extensive protection
application opportunities for overhead lines and cables,
or combinations of overhead lines and cables.

— The REL670 can offer more integrated • REL670-A42 offers everything included in
06 Line distance
protection options functionality compared to the REL650, REL670-A41, except the phase preference logic
such as full bay control functionality and • REL670-B42 is equal to the REL670-A42, but is

07 Ordering options synchrophasors (PMU) functionality. In order intended for 1 ½ or double breaker
for line distance to facilitate this additional functionality, there configurations.
protection
is a larger and more flexible choice in available • REL670-D42 is equal to REL670-A42, and in
hardware compared to the REL650 as well. addition includes synchrophasors (PMU)
functionality by default
REL670 and REL650 include features such as:
• Distance protection with 6 independent zones, REL650 comes in two different variants
for quadrilateral and mho characteristics • REL650-A11 offers a 6 zone distance protection
• Power swing detection and blocking, out-of- function with mho and quad characteristic, load
step and pole slip detection encroachment, power swing detection, out of
• Phase preference logic for the correct tripping step protection, overcurrent, frequency and
of multiple phase-to-earth faults in thermal overload protection. It also includes
compensated networks breaker failure protection, autoreclose and
• Back-up current, voltage and frequency synchrocheck functionality —
REL670 REL650
06
protection • REL650-A12 offers everything included in Distance protection X X
• Switchgear control functionality REL650-A11, and additionally phase preference
Speed < 1 cycle 1 1/2 cycle
logic. This functionality is required for a correct
Characteristic Mho, Quad Mho, Quad
REL670 comes in four different variants phase selection in high impedance or resonance
Zones 2 instances, 6 zones each 1 instance, 6 zones
• REL670-A41 offers a 6 zone distance protection earthed networks
Tripping 1ph/3ph 1ph/3ph
function with mho and quad characteristic, sub
Load encroachment X X
cycle tripping times, load encroachment, phase
Power swing blocking X X
preference logic, power swing detection.
Back-up protection Basic and additions as options Basic
Overcurrent, overvoltage, undervoltage,
Control of entire bay Optional Circuit breaker only
frequency and thermal overload protection are
available as backup protection functions and
included as basic or optional functionality. It
also includes breaker failure protection, —
REL670-A41 REL670-A42 REL670-B42 REL670-D42 REL650-A11 REL650-A12
07
autoreclose and synchrocheck functionality. High speed distance protection X X X X
This variant is used in isolated or high-
Distance protection X X
impedance earthed systems. All other variants
Phase preference logic X X
are intended for directly earthed systems.
Back-up protection Basic and additions as options Basic
Control of entire bay Optional Circuit breaker only

Double Single breaker


Configuration Single breaker Circuit breaker only
breaker with PMU
18 R e l i o n ® p r ot e c t i o n a n d c o n t r o l L i n e protectio n 19


Line differential protection.
Relion® RED670 and RED650
Differential protection is easier to integrate and delivers
more consistent performance as distance protection, at the
cost of an increased communication dependency.

— Line differential protection offers an easy, RED670 and RED650 include such features as: RED670 comes in four variants RED650 comes in one variant
08 Line differential
protection options accurate and secure alternative to line distance • Differential protection from 3 to 5 line ends, • RED670-B33 offers 2 – 5 line ends differential • RED650-A11 offers a 3 ended line differential
protection in line protection applications, but with up to two in-zone transformers protection with the possibility for increased protection function, with an option for an in-

09 Ordering options requires communication between the line ends. • Dedicated IED communication, performance over a 2 Mbit data link, improving zone transformer. It also offers a 6 zone
for line differential or multiplexer support trip time performance. distance protection function with mho and
protection
Relion RED670 and RED650 offer line differential • Back-up current, voltage and • RED670-A42 offers a high speed differential quad characteristic, load encroachment, power
protection and the option for line and cable frequency protection protection with sub-cycle trip times, and swing detection, out of step protection,
distance protection in the same device. With includes overcurrent, voltage, frequency and overcurrent, frequency and thermal overload
its high performance, high bandwidth and In addition, RED670 can include all the thermal overload protection. These are included protection. It includes breaker failure
low latency communication channel, RED670 functionality available in REL670, resulting as basic or optional functionality. It also protection, autoreclose and synchrocheck
delivers subcycle trip times in both its in a single device capable of both line includes breaker failure protection, autoreclose functionality.
differential and distance protection functions. differential and line distance protection. and synchrocheck functionality.
• RED670-B42 is equal to the RED670-A42,
RED650 provides a predefined, preconfigured but is intended for 1 ½ or double breaker
variant with a small form factor and a configurations.
standardized application solution. • RED670-C42 is equal to RED670-A42, and
includes the high speed, sub cycle distance
RED670 and RED650 can either be outfitted protection as the backup functionality to the
with their own dedicated long/medium- existing high speed line differential protection.
range communication module, or use
a short-range communication channel
to a multiplexer so that an independent
communication network can be used.

— —
08 RED670 RED650 09 RED670-B33 RED670-A42 RED670-B42 RED670-C42 RED650-A11
Differential protection X X High speed differential protection X X X
Speed < 1 cycle 1 1/2 cycle Differential protection X X
Communication speed 64 kbit/s or 2 Mbit/s 64 kbit/s High speed distance protection Optional X
Line ends 2-5 2-3 Distance protection X
In-zone transformer X X Basic and Basic and Basic and Basic and
Tripping 1ph/3ph 1ph/3ph Back-up protection additions as additions as additions as additions as Basic
options options options options
Distance protection X X
Circuit breaker
Back-up protection Basic and additions as options Basic Control of entire bay Optional
only
Control of entire bay Optional Circuit breaker only
Single breaker, Single breaker, Double breaker, Single breaker,
Time synchronization PPS, IRIG-B, GPS, IEC/IEEE 61850-9-3 PPS, IRIG-B, IEC/IEEE 61850-9-3 Configuration
2-5 line ends 2-3 line ends 2-3 line ends 2-3 line ends
20 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S u bstatio n s 21


Relion® the power of one solution.
For substations.
We deliver essential substation automation, high-voltage protection,
control and monitoring solutions for today’s power networks, — — —
ensuring they are ready for tomorrow’s challenges. Control applications Busbar protection Transformer protection
and voltage control
Advanced and ready made • Low impedance busbar protection
control solutions for interlocking for up to six bus bar zones
• Capability of protection transformer
and reservations
with differential protection and
As urban centers grow ever larger and the Substation solutions • Capability of using conventional
restricted earth fault
demand for electricity accelerates, power Substations are integral parts of a power hard wired measurements and
generation itself has entered a transitional phase. network, built to ensure grid infrastructure IEC61850-9-2 sampled values in
• Performing voltage regulation with
operates safely, reliably and efficiently. the same IED
the same IED
Traditional methods such as large-scale thermal Statistically, the number of faults in a substation
or hydro generation still dominate, but a new is substantially lower than in the more exposed
era of decentralized electricity generation overhead power lines, but the strategic
is developing. Decentralized generation is importance of a substation as a point where
characterized by small islands of balanced power everything in a power network comes together
supply and demand. But the intermittent nature makes the consequences of electrical failure
of this kind of generation, for example small wind even more severe. Reliability and capacity to
turbine or solar photovoltaic installations, makes minimize equipment damage is therefore vital.
a stable traditional electrical grid more important
than ever, and this is driving the development and ABB grid automation delivers an extensive
increased complexity of modern power networks. portfolio of protection, control and monitoring
solutions to keep substations safe and secure.
It is an accident of geography that many
power generation sites are situated far
from the centers of power consumption,
which means efficient ways of transporting
large amounts of electricity over longer and
longer distances is critically important.

As primary power systems become more


technically complex, secondary systems must
keep up with improved algorithms, enhanced
performance and rigorous control capability
to ensure network stability and continuity.
22 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S u bstatio n s 23


Circuit breakers and disconnectors.
Relion® REC670, REC650 and REQ650

— Circuit breakers and disconnectors The REQ650 provides ideal breaker failure • The REC650-A02 offers a configured solution Breaker backup protection may also be included
10 Bay control
unit varieties Circuit breakers, disconnectors and earthing protection, enabling high-speed back-up tripping for a single circuit breaker, and up to 9 in ABB’s REC670 bay control unit. REC670 offers
switches typically comprise the bulk of the of surrounding breakers, and retripping of the disconnectors and earthing switches. It is an extensive back-up protection function

11 Ordering options components inside a substation. There are many target breaker. REQ650 breaker protection is the suitable for single or double busbars library, which it shares with all other protection
for apparatus control types of breakers and switches, and many ways ideal choice for refurbishment projects, where • The REC670-A30 is very similar to the products in the 670 and 650 series. REC670
of configuring the connections between them. old protection relays need to be replaced. REC650-A02, but offers the possibility for more delivers the same high-performance protection
binary inputs and outputs and can include functionality as a dedicated protection device.
Circuit breaker and disconnector control ABB’s REC650 and REC670 offer various back-up protection functionality
Driven and controlled by the substation pre-configured variants to cover the • The REC670-B30 and C30 extend upon the
automation system, IEDs reserve, interlock and different switchgear configurations that REC670-A30 offering by including control for
actuate the circuit breakers and disconnectors exist in substations around the world. more switchgear, namely 2 circuit breakers with
that enable the electrical grid to operate. 13 switches, and 6 circuit breakers with 24
Interlocking and reservations switches for the B30 and C30 configurations
Circuit breaker protection REC670 and REC650 have ready respectively
Circuit breakers typically combine failure made logic function blocks for bay • Phasor measurement (PMU) functionality is an
protection with autoreclose, synchro-check and station wide interlocking. option in all REC670 configurations, however
and system back-up protection of functions the REC670-D30 configuration includes this
related to current, voltage and frequency. In IEC 61850 based reservation philosophy function by default, readily configured to be
ABB Relion protection IEDs this functionality prevents multiple operations of more used. Functionality wise, the REC670-D30
is basic or optional, and also available in than one apparatus in the substation. configuration is equivalent to the REC670-A30.
a product specifically designed for this The REC670 may also be ordered as a
purpose – the REQ650 breaker protection customized device, where all functionality
Intelligent Electronic Device (IED). is optional

— —
10 REC670* REC650** 11 REC670-A30 REC670-B30 REC670-C30 REC670-D30 REC650-A02 REQ650-B11
Circuit breaker, disconnector and
Up to 6 circuit breakers and 24 switches Up to 1 circuit breaker and 9 switches
earthing switch control
1 circuit
Generic switch control Up to 150 double point objects Up to 30 double point objects 1 circuit 2 circuit 1 circuit 1 circuit
1 ½ circuit breaker,
breaker, breakers, breaker, breaker,
IEC 61850 Edition 1 and 2 Edition 1 and 2 breaker double busbar,
double busbar double busbar double busbar double busbar
with PMU
Reservation With or without confirmation
Interlocking Pre-defined or user defined Control (CB / SW) 1/9 2 / 13 6 / 24 1/9 1/9
Operation Direct or select-before-operate, with or without enhanced security Voltage regulation and
Optional
OLTC control
Protection Optional X
Control functionality can be optionally integrated in
*
all Relion 670 series products, except for RES670 Synchrocheck X X X X X X
** All Relion 650 series products include Autoreclose X X X X X
basic control for 1 circuit breaker
IEEE 1344 / C37.118 (PMU) Optional
IEC 61850-9-2 8 SV streams (Optional) 4 SV streams (Optional)
24 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S u bstatio n s 25


Transformer protection, —
RET670 RET650

control and monitoring.


12

Voltage regulation
For single transformer or up to 8 parallel
For single transformer
transformers*
Tap changer control

Relion® RET670, RET650 IEC 61850 Edition 1 and 2 Edition 1 and 2

Full graphic display with circuit breaker,


HMI
disconnector and tap changer position indications

Supports up to 8 parallel transformers in a


*
group and with maximum 4 per RET670

— Transformers Transformer protection —


RET670 RET650
12 Options 13
for voltage control Electrical transformers are key pieces of Relion RET670 or RET650 intelligent electronic Differential protection 2 winding, 3 winding 2 winding, 3 winding
— equipment common throughout an electrical devices (IEDs) provide fast, reliable protection,
13 Transformer Restricted earth fault protection Included Included
protection grid. They are typically high-value, difficult monitoring and control solutions for all types of
Analog inputs Up to 24 12
functions and control to replace assets that can also become key transformers. In addition, RET670 offers state-

14 Ordering options weak points in electrical infrastructure as of-the art protection for autotransformers, Control Up to 6 circuit breakers and 24 switches Up to 3 circuit breakers
for Transformer stresses on the grid increase, and safeguards phase-shifting transformers and shunt reactors.
solutions
are overwhelmed. Unnecessary transformer These IEDs provide extremely fast differential Back-up protection Extended Basic
outages and undue equipment stresses protection with automatic CT ratio matching Voltage control, single transformer Included Included
should be avoided at all costs and a solution and vector group compensation, and are Voltage control, parallel transformers Optional No
should be adopted that help keep these high- ideal solutions for the most demanding
value assets in peak operating condition. transformer protection applications.

RET670 comes in 4 pre-configured variants, RET650 comes in 2 pre-configured variants:


Voltage control RET650 delivers complete protection
as well as a completely customizable solution: • RET650-A01 is intended for 2 winding
Voltage regulation and tap changer for two- or three-winding transformers,
• RET670-A10 is intended as a back-up protection transformers and RET650-A05 for three
control are required for any transformer while RET670 can also provide control
solution. It doesn’t offer differential protection winding transformers. Both devices are 6U ½
with an on load tap changer (OLTC), but it for up to 30 switching objects.
such as the B30 and B40 configurations do, but 19” devices, offering a lot of functionality in a
needn’t be a separate control device.
includes all possible back-up protection, small package
One RET670 IED can be extended to contain two
making it ideal as a complementing product.
RET670 and RET650 both include voltage differential protection functions to protect the
• RET670-A25 is a dedicated voltage regulator
regulation and tap changer control for a most advanced system configurations, providing
solution, with the possibility to include some
single transformer, while RET670 can also increased functional integration and more cost-
back-up protection functionality
be configured for voltage regulation and tap effective protection and control solutions.
• RET670-B30 and B40 are intended for
changer control of up to 8 parallel transformers.
respectively two winding and three winding
Transformer monitoring
transformers. They include transformer
Advanced transformer monitoring functions
differential and restricted earth fault
are included. These enable preventive
protection, and offer a selection of standard
maintenance of the equipment thereby
and optional back-up protection functionality
avoiding outages and saving significant costs.
Monitoring functionalities include estimation
of transformer insulation loss of life based on —
top oil temperature measurement/calculation 14 RET670-A10 RET670-A25 RET670-B30 RET670-B40 RET650-A01 RET650-A05
and monitoring of transformer through faults.
Two winding differential
X X
protection
Three winding differential
X X
protection
Back-up protection X Optional X X X X
Apparatus control Optional
Voltage regulation and
Optional X Optional Single transformer
OLTC control
IEEE 1344 / C37.118 (PMU) Optional
Apparatus control Optional Circuit breaker only
IEC 61850-9-2 streams 8 SV streams (Optional) 4 SV streams (Optional)
26 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S u bstatio n s 27


Busbar protection.
Relion® REB670, REB650 and REB500
The heart of a substation is its busbar configuration. Although typically designed
in single or double busbar systems, there are many other designs, each with
specific advantages. ABB’s Relion family of IEDs provides the flexibility to adjust
to any busbar configuration, and delivers unrivaled reliability and performance.

— Traditional busbar differential protection Centralized busbar protection is also generally


15 Busbar protection
variants employs a high impedance system. This relatively faster because different IEDs do not have to
simple overvoltage or overcurrent function communicate, eliminating delays. However,

16 Ordering options requires several supporting functions in a modern this does impact the size and extendibility
for busbar protection substation, such as advanced disturbance requirements of the protection IED – each
recording and communication capabilities. bay requires a certain number of IOs, which
must fit in a single device and be wired from
REB650 is a dedicated, high performance, the bay to the centralized IED. This can be
high impedance differential protection difficult from a station topology point of view,
IED that fills this application space. particularly in large, open-air substations.

The performance and reliability of high


impedance differential protection systems is REB670 offers an easy to configure
hard to match using alternative methods, but
they are also more costly, complex, and require
centralized busbar protection for
the use of dedicated current transformers. High up to 24 feeders, and can cover up
impedance differential protection schemes must
also deal with potentially very high voltages near
to 6 independent busbar zones. —
15 REB500 REB670 REB650
commissioning and maintenance personnel. Type Distributed, low impedance Centralized, low impedance High impedance

Instead, low impedance differential In a distributed solution, a single, central IED Number of bays 60 24 Not applicable
protection is much easier to incorporate connects many satellites (bay units), which Number of zones 32 6 3
into modern protection systems, is are connected to the process. Typically, a
considerably safer and considered the best distributed solution scales much better, as the
solution by utilities all over the world. IO is not concentrated on a single IED, which also —
drastically reduces the wiring needed between 16 REB670
REB670-A20 REB670-A31 REB670-B20 REB670-B21 REB670-B31 REB500 REB650-A03
Customized
ABB grid automation provides products for different parts of the installation. Instead of
Low
two different approaches to low impedance many cables coming from every feeder to a Differential High
Low impedance, centralized impedance,
differential protection applications: central location, a single optical fiber cable principle impedance
distributed
REB670 for centralized and REB500 for between the bays and the central IED suffices. Measurement Three-phase Single-phase Three-phase
distributed busbar protection solutions. Zones 2 2 2 2 2 6 32 3
Although communication delays and the Bays 4 8 12 12 24 24 60 X
A centralized solution puts all process synchronization of many measurement points
Overcurrent /
inputs and outputs in a single place - the from different places reduces performance to end fault Optional X
busbar protection IED. This reduces IED some extent, it is still well within acceptable (and protection
hardware costs substantially, because it accepted) levels. While the additional hardware Voltage and
eliminates the need for additional hardware increases initial costs of a distributed installation current backup X X X
protection
in all bays, unlike a distributed solution. compared to a centralized solution, subsequent
installation costs can be reduced due to the Breaker failure
Optional X
protection
reduction of wiring throughout the installation.
Circuit breaker
REB500 delivers a high-performance solution, X X X X X Optional X
monitoring
with industry leading reliability and sub cycle
performance that scales up to very complex
system topologies and many connected feeders.
28 R e l i o n ® p r ot e c t i o n a n d c o n t r o l 29


Phasor measurement unit.
Relion® RES670
The Relion 670 series of protection and control intelligent
electronic devices (IEDs) can provide power system AC voltages
and currents as phasors.

— Enhanced monitoring enables power network Depending on the product, these devices
17 Available phasor
measurements operators to take fast remedial action and can transmit up to 32 analog phasors in two
per product type use existing power systems more efficiently. different data streams. The high accuracy of
— Better information supporting fast, reliable voltage and current measurements eliminates
18 Ordering options emergency actions reduces the need for relatively the need for any external measurement
for standalone phasor
measurement units high transmission margins made necessary transducers, which makes the 670 series ideal
by potential power system disturbances. for use in all types of Phasor Measurement
Unit (PMU)-based applications.


17 RES670 REL670, RED670, REC670 REG670 RET670
Phasors 32 8 16 24
Systems 2 1 2 1
Time synchronization GPS, IRIG-B, IEC/IEEE 61850-9-3

IEEE 1344-1995 and IEEE Std C37.118-2005 (Both measurements and data communication),
IEEE Std C37.118.1-2011 and IEEE Std C37.118.1a-2014 (Measurements),
Compliance IEEE Std C37.118.2-2011 (Data communication)

RES670 comes in 2 preconfigured variants: • RES670-B20 is intended for up to 6 bays and a


• RES670-A20 is intended for up to 3 bays and a double busbar. It can handle two distinct PMU
single busbar. Although it can handle two reports, meaning it can handle differing
distinct PMU reports, meaning it can handle 2 frequency rates on both busbars and still report
separate system frequencies, it is configured the frequency accurately. It features automatic
for a single frequency (busbar) system. configuration of the correct frequency system
based on the status indications of the
disconnector inputs of the bay.


18 RES670-A20 RES670-B20 Customized
Configuration 3 bays, single busbar 6 bays, double busbar
C37.118 2011 and IEEE1344 reports 2 2 2
Phasor data 16 32 Up to 32
Analog data 8, up to 24 16, up to 24 Up to 24
Binary data 8, up to 24 16, up to 24 Up to 24
System protection Basic and optional Optional
30 R e l i o n ® p r ot e c t i o n a n d c o n t r o l R a ilw ay s 31


Relion® the power of one solution.
for railways.
ABB delivers a comprehensive range of rail and urban transport
infrastructure solutions for AC systems that ensure safe,
reliable power delivery to all essential rail assets.

Rapid urbanization plus the urgent need to Relion RER670 applications include protection, Line protection Catenary protection Transformer protection Control and monitoring
reduce carbon dioxide emissions are driving control and monitoring of AT and BT catenary • Line distance protection • Catenary distance • Transformer • Control for up
substantial new interest and investment in systems, single and double phase power • Scheme communication protection for 2 catenaries differential protection to 15 apparatuses
the transportation sector. Because of their transformers, single and double phase • Fault location • Scheme communication • Transformer under • Tap changer control
specialized nature, traction power protection transmission lines, and incorporate control • Back-up protection • Fault location impedance protection and supervision
and control systems can be challenging. and communication functionality based on IEC • Synchrocheck • Back-up protection • Restricted earth fault • Circuit breaker monitoring
61850 edition 2. The RER670 is designed to be and auto-reclose • Synchrocheck protection
With the Relion RER670, ABB offers a single used on 16.7 Hz, 50 Hz and 60 Hz networks. and auto-reclose • Transformer tank
solution encompassing the entire scope of railway overcurrent protection
power delivery; transmission, transformation With over 150000 Relion devices installed • Transformer energization
and delivery. In a single device it supports globally, RER670 has a robust family history control (16.7 Hz)
single and two phase systems in isolated, and is a testament of the trust that • Back-up protection
compensated or solidly earthed networks. has enabled numerous users to secure • Synchrocheck
their power infrastructure. • Monitoring of power
system harmonics
32 R e l i o n ® p r ot e c t i o n a n d c o n t r o l R a ilw ay s 33

— —

Railway solution. 19

Relion® RER670 Transformer protection for Simplified distance


reliable, high-performance protection for your
and flexible applications catenary infrastructure

RER670 is used for the protection, control and monitoring of transmission


Safeguarding your
lines or transformers in 16.7 Hz, 50 Hz and 60 Hz railway applications. assets with RER670

Fast and reliable line Control functions for


— Line protection Catenary protection protection for all types of optimized control and
19 Application areas
for RER670 Line protection is covered by the distance Catenary distance protection package is similar power system grounding reliable operation of the
protection function with quadrilateral or circular to the line protection package, but is used as devices in your switchyard

20 Ordering options starting characteristics. The six zones have a distance protection for catenary feeders,
for railway solutions fully independent measurements and settings which supply the moving locomotive through
from each other which gives high flexibility a pantograph. The function is applicable
for all types of lines. Load encroachment and for single-phase booster transformer (BT)
adaptive reach compensation are included. railway supply systems and can be used as RER670 can be ordered with • The A51, B60 and B70 packages all include
Communication to remote ends can be a simplified distance protection for auto these functional packages: back-up protection, consisting of (residual)
used for even more selective protection, transformer (AT) catenary systems. • The A51 package is intended for transformer overcurrent, thermal overload, breaker failure,
via traditional tele protection equipment or protection. It includes transformer under (residual) under and overvoltage, and under
through direct IED to IED communication. Control and interlocking impedance, differential, restricted earth fault frequency protection.
This IED can also be provided with full bay and tank overcurrent protection functionality. • The H37 and H38 packages offer apparatus
Backup functions like directional earth fault or control and interlocking functionality. The • The B60 package is intended for line protection. control for 10 (1 circuit breaker) or 15 (2 circuit
overcurrent as well as breaker failure protection autorecloser includes priority features It includes distance and switch onto fault breakers) switching objects respectively. The
are available, as well as autoreclose and for multi breaker arrangements. It co- protection, scheme communication and multi backup protection package can be optionally
synchrocheck functions. A line fault locator for operates with the synchrocheck function section fault location functionality. added to these control packages.
up to 10 line segment supports efficient remedial with high-speed or delayed reclosing. • The B70 package is intended for catenary
actions after faults on the transmission line. protection. It includes catenary distance and Further options include transformer energization
Communication switch onto fault protection, scheme control, transformer tap changer control, and
Transformer protection RER670 provides extensive IEC 61850 communication and multi section fault location current and voltage harmonic monitoring.
The transformer differential protection function support, and incorporates such functions functionality.
covers different traction power transformer as MMS, GOOSE, SV, PTP, HSR and PRP, as The number and type of analog inputs
configurations and a wide range of current well as IEC 60870-5-103 communication. and binary inputs and outputs as well as
and voltage backup functions are available, mA input and communication modules
including restricted earth fault protection. Binary signals can be exchanged with can be selected when ordering.
the Line Data Communication Module
A very fast transformer tank protection (LDCM). Communication between IEDs
helps to avoid damages in case of short in different substations is supported —
20
Software options
circuits to the transformer tank. using the IEEE C37.94 standard.

Transformer Line Catenary Back-up Apparatus Auto- Synchro- Transformer Tap changer Harmonic I/U vector
protection protection protection protection control reclose check energization control control monitoring shift
A51 B60 B70 C61 H37/H38 H52 H51 H55 H53/H54 M27 supervision

Transformer
X X Optional Optional X Optional X
protection

Line protection X X Optional X


Applications

Catenary
X X Optional X
protection

Control Optional X Optional X

Multiple options can be selected per physical device


34 R e l i o n ® p r ot e c t i o n a n d c o n t r o l P o w er ge n er atio n a n d re n e w a bles 35


Relion® the power of one solution. Technology may change, but safety, quality and reliability remain the top
requirements of any power generation source. Whether the generation solution is
For power generation and renewables. large or small, centralized or distributed. In the end, every minute not spent
producing energy has tremendous financial and social consequences. ABB is at the
forefront of the digitalization that is sweeping over the power generation space.
We deliver secure power generation solutions by continuously adapting Our digital substation portfolio enables customers to build for the future - today,
to the active system situation, guaranteeing reliability and performance. while still enjoying the long-term ABB know-how and support of the existing market.

Thermal power plants Generator


Burning natural gas, coal, diesel oil, biomass A generator is one of the most complex and
or using nuclear fission to create steam, which essential pieces of electrical equipment in

in turn drives turbines and generators is how a power station. Without it no electricity Generator protection
most electrical power on earth is presently will be produced, so unnecessary outages
produced, and thermal power generation and undue stress on the generator
and renewables
will remain an integral part of the energy are to be avoided at all cost.
mix for a very long time. As the grid and Complete protection of generators,
the machinery connected to it become ever Transformer transformers and generator-transformer
larger and more complex, reliable sources of Step-up and auxiliary transformers are high blocks of all sizes and types.
quality power are crucial for its stability. value, difficult to replace assets that are
as much a part of a generator protection
Hydroelectric power plants solution as the generator protection device
Moving water is the oldest green technology, itself. Step-up transformers can potentially
which has produced energy for mankind for be exposed to a much larger frequency range
thousands of years, and electricity for more than than conventional transformers, and may
a century. Hydro generation continues to play also face very different conditions during
a significant role in modern power networks fault and through fault incidents because
as a load balancer and as a source of cheap, of their proximity to the generator.
renewable energy. Although in many regions
many of the most accessible hydro locations A protection solution for every component
have been developed, pumped storage upgrade ABB’s Relion family of IEDs delivers control,
solutions are breathing new life and interest in protection and monitoring solutions that
existing installations. In regions with untapped protect these vital generating assets. With
renewable generation potential, hydro helps its proven reliability, high accuracy and high
to integrate other renewable sources such performance operation, the Relion series can
as wind and solar power into the network, by be used for the most demanding applications.
providing stability and storage capacity.
Advanced control capabilities and system
Renewable generation modeling, such as given by IEC 61850 will
Sustainable power, such as solar photovoltaic, give you new ways to design and dynamically
large and small hydroelectric and wind turbines operate your network or power plant. And
deployed either onshore or offshore are part of in the smart grid, information is of vital
the power generation future. Their deployment importance, so advanced and accurate PMU
in our electrical networks is steeply on the rise (phasor measurement unit) functionality
and only expected to increase in the future, will present you with the information you
but this is not always an easy process. need to make your smart grid truly smart.

Utility-scale renewable generation is typically


situated in remote, difficult to access
locations, such as far out to sea, in a desert or
on a mountaintop, which means they require
advanced protection and control equipment
to ensure a reliable connection to the grid.
36 R e l i o n ® p r ot e c t i o n a n d c o n t r o l P o w er ge n er atio n a n d re n e w a bles 37


Generator protection,
control and monitoring.
Relion® REG670
Relion REG670 Intelligent Electronic Device (IED) is a protection and monitoring
solution for generators, prime movers and step-up transformers in hydro, pumped
storage, gas fired, combined cycle, steam, and cogeneration power plants.

— Supported by ABB’s extensive experience No changes are necessary in the primary circuit
21 Ordering options
for generator protection in generator protection solutions, REG670 or grounding resistor, so the design, installation
achieves a new level of performance with up and commissioning of the protection system
to 24 analog inputs, and the availability of is simple and fast. The third harmonic-based
IEC61850-9-2 process bus technology. Main 100 percent stator earth fault protection
and back-up protection can be integrated utilizes the differential principle, providing
into one IED, and additional components like high sensitivity and security to ensure proper
transformers can be included in the scope of operation even in low load conditions.
protection. This reduces the number of IEDs
needed to protect the generating station. It REG670 comes in 3 different
also increases availability, simplifies installation pre-configured variants, as well as a
and reduces lifecycle costs relating to completely customizable solution:
commissioning, maintenance and spare parts. • REG670-A20 offers a solution for a typical
generator protection application with
generator differential and back-up protection
Using an advanced and innovative including 12 analog inputs transformers in a half
filtering technique, REG670 can 19” case size
• REG670-B30 offers enhanced generator
provide integrated sub protection application with generator
synchronous resonance differential and back-up protection, including
24 analog inputs in a full 19” case size.
protection for turbo generators. Optionally, pole slip protection, 100% stator
earth fault protection and overall block
A REG670 generator protection scheme delivers
differential protection can be added —
REG670-A20 REG670-B30 REG670-C30
maximum dependability and availability, 21
• REG670-C30 offers complete unit protection,
featuring extremely fast detection criteria Generator differential,
including generator and generator transformer Generator differential and Generator and block
(typically 15 milliseconds) for generator transformer differential and
backup protection transformer protection
protection with 24 analog inputs in a full 19” backup protection
differential protection, while maintaining a high
case size. Optionally pole slip protection Generator differential protection x x x
level of security with DC offset functionality.
and 100% stator earth fault protection can Two winding transformer
Among the REG670’s many functions, is injection- Optional x
be added differential protection
based 100 percent stator and rotor earth fault
Three winding transformer/
protection, as well as third harmonic-based 100 Optional x
block differential protection
percent stator earth fault protection. These
solutions optimize the protection system’s Extensive function selection included,
Backup protection
and additional functionality available
cost-performance ratio in relation to the
Apparatus control Optional
importance or size of the generating station.
ABB’s innovative solution enables injection IEEE 1344/C37.118(PMU) Optional

via a neutral point VT, or even an open-delta IEC 61850-9-2 8 SV streams (Optional)

VT located at the generator terminals.


38 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S oft w a re E n gi n eeri n g Tools 39


Protection and control manager for IEDs.
PCM600

22
Application configuration allows you to easily With the signal matrix, you can connect the
create, change or view an IED configuration. process termination with any I/O connection
The colors of the function blocks relate to point in the configuration in the same way as
the function status in the configuration: the traditional trip matrix.
Ethernet Switch
unconnected (gray), partially connected
PCM600 IED
In remote office (yellow) or fully connected (green).

Ethernet Switch
Gateway Gateway IED
With firewall With firewall

PCM600 IED PCM600 With the graphical display editor, you can easily The parameter setting tool allows you to change
On substation network Connected to the engineer the single line diagram according to or view all the parameters that an IED has,
IED front port
the switchgear arrangement for the IED HMI. for all the setting groups. When reading the
parameters from the IED, you can easily compare
the values in the PC with the ones in the IED.
The graphical representation of protection
characteristics supports you in visualizing, for
example, distance protection parameter setting.
— PCM600 provides versatile functionalities for the • Graphical representation of parameters
22 An overview
of PCM600's efficient entire life- cycle of Relion® protection and control simplifies setting of protection function
management of IED applications. This easy-to-handle tool helps you parameters
ABB's protection
and control IEDs manage your protection and control equipment • Configuration of IED hardware and IED display Tool suite for engineering, integration and testing.
all the way from application and communication • Communication management
— ABB‘s comprehensive suite of tools (PCM600, systems. With many advanced features, the
23 Tool suite configuration to disturbance handling, • Signal matrix for efficient and flexible
IET600 and ITT600) for engineering, integration tools allow you to manage your installation
for engineering, including automatic disturbance reporting. connection of CTs, VTs and binary input and
integration and testing and testing supports you throughout the efficiently in all situations from engineering and
output signals, as well as connection of the
complete lifecycle of protection and control IEDs commissioning to operation and maintenance.
PCM600 interacts with IEDs over the fast and GOOSE (Generic Object Oriented System-Wide
and IEC 61850-based substation automation
reliable TCP/IP protocol via a corporate LAN Events) signals between IEDs
or WAN, or alternatively directly through the • Comparison of configuration between IEDs
communication port at the front of the IED. It and PCM600, as well as SCL (substation —
23
is able to read and write all configuration configuration description language) files at SCD
and setting data of an IED with a single (substation configuration description) import
command. The user interface, workflow • Monitoring of IED signals and events System Engineering .scd Substation Automation System
and the IEC 61850-based data model in the • Integrated disturbance recording IET600
PCM600 are designed according to the same functionalities for scanning and analysis of
philosophy as the Relion protection and disturbance information
control IEDs, ensuring smooth and seamless • Copy/paste and export/import functions to
integration between the tool and the IEDs. allow efficient reuse of existing IEDs, bays
or substations
Top 10 features of the protection and control • Utilizes ABB’s unique Connectivity Package
IED manager PCM600: concept which contains a comprehensive System Testing Managing Relion
• Powerful application configuration for creating description of the IED, consisting of data ITT600 SA Explorer Protection and Control
and monitoring application configuration signals and parameters as well as the IED IEDs PCM600
documentation Process Interface Process Interface
40 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S oft w a re E n gi n eeri n g Tools 41


Integrated engineering tool.
IET600
Integrated engineering tool IET600 is designed for configuring IET600 provides powerful graphic editors to design IET600’s communication editors allow fast
IEC 61850-based substation automation systems and applications and configure the substation topology according and easy configuration of the dataflow
to IEC 61850. System engineers can easily define between all IEC 61850-compliant IEDs in the
with IEC 61850 compliant IEDs from ABB and other vendors. the substation layout using the built-in Single Line substation. Built-in consistency checks and
palette of primary equipment, assign internal clear representation of information reduces
and customer-specific names to the devices, and errors during the engineering process.
print the configuration for documentation.

IET600 allows system engineers and integrators Features


to define and configure the complete substation • IEC 61850 oriented project explorer for fast
automation system according to IEC 61850. navigation within a project / substation
It features powerful graphical interfaces to -- Primary objects view
design the substation topology, manage the -- Communication subnetworks view
communication between all IEC 61850-compliant -- IED view
IEDs in the substation and generate a complete -- HMI view
description of the substation in an SCD file. • Default support for primary and secondary
equipment naming scheme according IEC 81346
IET600 provides a simplified, consistent and • Station wide consistent IEC 61850 dataflow IET600 provides a comprehensive graphical Configure and manage station and gateway-
flexible approach to SA system engineering configuration editor for the physical network configuration of level signals for ABB’s MicroSCADA SYS600
enabling substation engineers to design -- View or engineer dataset and dataflow the SA System. The detailed layout is included in platform from IET600 to ensure data
the complete system engineering of an IEC configuration, for vertical or horizontal IEC the exported SCD file and can subsequently be consistency throughout the station. Automatic
61850-based substation with a single tool. 61850 communication reused for IEC61850 testing and commissioning calculations and easy reuse of engineered
-- Comprehensive matrix for efficient and applications like the ABB ITT600 SA Explorer signals give engineers a powerful means
IET600’s combination of powerful engineering flexible configuration of: to configure the station computers.
editors and built-in IEC 61850 intelligence - MMS client server reporting
allows engineers to integrate protection and - GOOSE publisher/subscriber
control IEDs easily and effectively, including - Sampled values publisher/subscriber
devices from third-party vendors. IET600 -- Configuration of IEC 61850 substation to
performs consistency checks at every step substation communication
of the engineering process, which can -- Configuration of IEC 61850 functions & sub- Features Features
significantly reduce the amount of errors functions • HMI database maintenance for ABB • Supported IEC 61850 file formats
not only during system engineering, but also -- Freely adaptable tool behavior for handling MicroSCADA Pro SYS600/C based substation -- SCL import
subsequently during the system integration, IEC 61850 IED capabilities for higher automation systems - SCD, ICD, CID, IID
testing and commissioning phase. engineering tool interoperability • Powerful copy/paste functions for: - SED (SCL version 2007 Rev.B)
-- Transparent IEC 61850 configuration -- Single or multiple HMI signals - SCL export
Centralized configuration and maintenance comparison when importing SCL files -- IEC 61850 IEDs - SCD, ICD, IID
of substation signals for ABB’s MicroSCADA • Graphical editor for single line diagram -- Grafical bay single line diagram - SED (SCL version 2007 Rev.B)
platform ensures that data consistency is assured -- Bay oriented -- Fully engineered bays including IEDs, single • *.xls export for documentation of complete IEC
throughout the lifecycle of the substation. -- Voltage level oriented line diagram, logical node mapping, ABB 61850 dataflow
The modern and intuitive user interface allows -- Including IEC 61850 logical node mapping MicroSCADA Pro SYS600/C database signals • Supported IEC 61850 SCL scheme versions
engineers to easily navigate through large to primary equipment & functions • Seemless migration of projects from the -- 2003 Rev.A
amounts of data to find exactly what they need. • Graphical editor for network configuration predecessor versions -- 2007 Rev.B
diagram covering and supporting • Supported file exchange formats for ABB
With over a thousand deployed systems -- IEDs, HMIs, Gateways MicroSCADA SYS600/C
worldwide, IET600 integrates ABB’s long- -- Ethernet switches -- *.lof/*.csv database load file (complete)
term IEC 61850 expertise. ABB’s UCA -- Switch configuration according to -- *.sfx file database load file (changes only)
International certified in-house System IEC 61850-90-4 -- *.xrf/*.txt gateway configuration files
Verification Center continuously ensures that • Integral communication address -- *.xls database documentation
IET600 meets the integration and system configuration tables
performance requirements of ABB and third-
party protection and control devices.
42 R e l i o n ® p r ot e c t i o n a n d c o n t r o l S oft w a re E n gi n eeri n g Tools 43


Integrated testing tool.
ITT600 SA Explorer
Integrated testing tool ITT600 SA Explorer is designed ITT600 SA Explorer makes GOOSE messages ITT600 SA Explorer allows you to connect to
for easy diagnosis and troubleshooting of IEC 61850-based visible, and presents the transmitted GOOSE any IEC 61850-compliant IED, browse the IED
values both on-line and off-line. The tool configuration, subscribe to IEC 61850 reports,
substation automation systems and applications. allows you to focus on the application behavior send Select-before-operate commands and
and verify the traffic instead of searching review the IED’s response in the built-in event list.
for specific values in GOOSE frames.

It features convenient navigation, comprehensive Top 10 features of the integrated


presentation of application data, and support testing tool ITT600 SA Explorer:
for system consistency check both on-line • Exploration of the complete IEC 61850
and off-line. This allows anybody to use the communication configuration of ABB’s
same tool to analyze and debug substation Relion protection and control IEDs and
automation applications regardless of their level third-party IEDs.
of knowledge of IEC 61850 communication. • Process event list with filtering and exporting
capabilities to support testing and
The ITT600 SA Explorer tool offers facilities for commissioning of the IEDs.
exploring and analyzing the communication • Many advanced functionalities, such as creation ITT600 SA Explorer visualizes up to two IEC 61850 When analyzing communication within a
configuration of the protection and control of dynamic datasets and editing of setting 9-2 LE streams in a phasor diagram and as RMS substation automation system, ITT600 SA
IEDs (Intelligent Electronic Devices) and IEC group values. values to allow engineers to evaluate primary Explorer allows you to focus on the transmitted
61850 communication in substation automation • Manual and automatic comparison of the currents and voltages sent by merging unit on- payload instead of protocol details. You only need
systems, including GOOSE messages. Its versatile system configuration description (.scd) and line. Off-line analysis for one stream includes an to concentrate on the application values important
functionality eliminates the need for multiple the deployed IED configurations to ensure oscilloscope style view of the sampled values. to you while the tool’s unique built-in consistency
testing tools for different purposes, such as MMS data consistency. check functionality takes care of the details.
browsers, and protocol and Ethernet analyzers. • Documentation of the system configuration
revisions and IED firmware versions to keep
The powerful features of ITT600 SA Explorer track of the changes in the system.
provide test engineers with access to any • Unique graphical visualization of the data flow
IEC 61850-compliant IED. The tool’s various within an IEC 61850-based system to verify and,
functions allow efficient testing of the IED if needed, optimize the data flow.
application and isolate the root cause of system • Visualization of GOOSE data in an Oscilloscope
communication problems. This significantly style view simultaneously for several IEDs
reduces testing and commissioning time. showing correlations and time measuring. This
enables faster debugging and troubleshooting.
ITT600 SA Explorer is easy to use, and does • Support for decoding and analysis of
not require the skills of a data communication substation automation-related Ethernet-based
specialist. By translating the complex communication protocols, such as IEC 61850-8-
terminology of communication protocols into 1, IEC 61850-9-2, IEC 60870-5-104, DNP 3.0/TCP
the standardized IEC 61850 language, it makes and Modbus/TCP.
the essential information available to all users. • Comparison of any two SCL-based (substation
configuration description language) files at the
same time; for instance, comparison of two .icd
files to identify the differences between them.
• Visualization of IEC61850-9-2 LE sampled value
streams in a phasor and Oscilloscope style view.

ABB AB