ZS - 300 Series
of Products
Structures
Model ZS-300 series of automatic clinical chemistry analyzers
consists of four types:ZS-310,ZS-320,ZS-330,ZS-340.

ZS-310 use single probe system and working speed is


200Tests/hour for clinical chemistry.

ZS-320 ZS-330 and ZS-340 use double probes system and


working speed up to 360Tests/hour for clinical chemistry.

Model ZS-300 series of automatic chemistry analyzer


consists of the instrument host and the operating system
software(CD-ROM),wherein the instrument host consists
of the optics, mechanical movement, fluid path, electronic
control, This instrument is used for the routine clinical
chemistry tests for the samples, such as blood, urine,
ascites and cerebrospinal fluid, etc.

Functional Principle

Advanced Technology Add reagent R2


Add
Add sample (inapplicable to Blend
and Perfect Design reagent R1
simple reagent)
Real discrete system, the modular integrated for each part, and
convenient maintenance

Automatic pre-dilution function, automatic pre-dilution (re-assay)

Available for single or double reagents

Open systems with comprehensive testing methods, optional


Calculate and
React at body
for all brands reagents display the Test
temperature
result
ZS - 300 Series High Quality

of Products
Colorimetry System
· 72 standalone quartz cuvettes with long

Advantages
service life ,affordable cost and can be
replaced individually

· High precision reversed optics grating


photometry system with a selection of 12
wavelengths ranging from 340 to 800nm,
primary and secondary wavelength optional.

ZS-310 reagent tray


integrated with sample
tray,45 reagent positions
and 45 sample positions
Accurate Sample
Adding System
·Accurate reagent probe with the functions
of liquid detection and VOD test, which
ensure probe safety and collision protection

·Sample probe and reagent probe with


Teflon layer to minimize contaminations

·Sample syringe distribution volume


3-35μL,sample precision 0.1μL

ZS-320/330/340
independent reagent
tray and sample tray,45
reagent positions and 60
sample positions
Humanized Design
Considerate Care
·Constant refrigeration for reagent tray
ensures the stability of reagent

·Liquid level sensor detects the leftover of


reagent

·Stored 120 parameters and adding more if


needed
ZS - 300 Series Performance

of Products
Parameters

Advantages
Fully automated, Discrete, Random access for routine,
System Function
STAT sample priority

System With package: 1033mm×830mm×1350mm (W×D×H)


Function Dimension
Without package: 830mm×670mm×1150mm(W×D×H)

Weight 145Kg

ZS-310:constant 200Tests/hour for clinical chemistry


Working Speed
ZS-320/330/340:contant 300/330/360Tests/hour for clinical chemistry

Methodology End-point, Two-point, Rate A/Rate B(kinetic),Fix time,etc.

Test Parameter 120parameters


Basic
Easy Cleaning and Reaction Temperature 37℃ ±0.1℃
function
Stirring System Test temperature 37℃

Spectrophotometry Holographic concave flat field reversed grating system with 12 wave-
Multi-step continuous washing system, Technology lengths (340-800nm)
monitoring cleanliness of cuvettes,
automatically detect and skip the cuvettes Absorbance range 0~3.5 Abs (Resolution:0.0001Abs)
which do not conform to the standard Test Methods Reagent Tray 45 reagent positions in 24-hour refrigerated compartments(2~8℃ )
·Thoroughly washing and cleaning with low ·Batch processing, Parameter combination, ordinal test, STAT
water consumption up to 6-8liters per hour,to ZS-310:45 sample positions
minimize cross contamination between ·End-point,two-point, Rate A/ Rate B(kinetic),etc. Sample Tray ZS-320/330/340:60 sample positions
samples. All types:optional for QC, sample and STAT

·Independent stirrer can automatically adjust Reagent &Sample Probe


With Teflon layer to minimize contaminations, Liquid level &Clot De-
the stirring speed and prevent the generation tection, VOD Test, Collision protection and automatic resetting
of bubbles to ensure the accuracy of testing Sample,
results. A special material with corrosion Reagent Reagent Volume 50-350μL,step by 1.0μL(Minimum:15μL)
resistance is used for the stirring rod, thus no System Sample Volume 3-35μL,step by 0.1μL(Minimum:2μL)
wall leftover and long service life.
Reaction Volume Minimum:100μL

Automatic Dilution Function Automatic sample dilution

Reaction Process Monitoring Real-time monitoring of system working status

Cuvettes 72 Permanent quartz cuvettes

Washing Normal Washing, Detergent Washing ,warm water washing and special
Auto-Washing station
System test washing
More Features STAT Easy access for an STAT sample at any time
·Independent software control system(applicable
QC Rules Westgard, L-J, Cumulative sum, etc.(Diagram Printing)
to the discrete test of reagent probe,sample probe
and other motors),Easy maintenance .Automatic Analyses
Calibration Rules Linearity,Logit-4P/5P,Spline,Factor,etc.
maintenance program System
Water consumption 6-8/hour
·Ensures the sustainability of accuracy and
precision Operation system Window*XP, Window*7,Window*8,Window*10

·Constant temperature control for reaction Data RS-232,USB outlet, Bi-directional LIS interface for remote operation and
Interface
tray at 37℃ ±0.1℃ ,safe, efficient, free of daily System maintenance
maintenance
Power
Power Supply AC 220V Single-Phase with Three-line