Platform
Platform Requirements Industry Standards and Compliance Weight and Size
The mainframe shall be non modular CE Class A Compliant The weight of the test set shall not be
greater than 4.2 lbs/1.9kg while supporting
The product shall be field upgradeable EMI/ESD: CE compliant, FCC part 15 subpart
up to 10G rates
A Class A
The test system shall utilize Linux operating
The size of the test set shall not be greater
system to ensure optimum stability FCC Part 15 Compliant
than 17.78 x 24.13 x 7.62cm (7”x9.5”x3”) while
Display Physical and Environment Specifications supporting up to 10G rates
The size of the display shall be 7 inches Temperature range: Operation
minimum, and 1200x600 type for best • Operating, all options: 0°C to +50°C
The base unit shall be able to be turned on
resolution (+32°F to +122°F)
and operational in less than 2 minute
• Storage: - 20°C to +60°C (-4°F to +140°F)
The Test Set shall support a Screen Saver
The Test Equipment shall accept operations
Storage Humidity: 10-95% without
The Test Set shall support a mode that with an external keyboard.
condensing.
'locks' the touchscreen for use without a
The unit will boot to a simplified launch
password Operating Humidity: 10-90% without
page allowing the user to select previous
condensing.
Power/Battery test configurations and/or favorite test
Drop Test - Shock configurations.
The Test Equipment must be battery
operated per IEC 68-2-27 and 68-2-29 Ed. 2.0 I/O’s
The Test Equipment must have a built-in Drop Test - Durability The Test Equipment shall include the
battery charger following I/O interfaces
per IEC 721-3-7 2nd Ed./IEC 61010-1
The battery must be field replaceable • VT100 (RJ-45)
Vibration • 2 x USB
The equipment shall perform a 10G test for • RJ-45 (Ethernet/IP)
per IEC 68-2-6 and MIL-PRF-28800F
a minimum of 3 hours on battery power. • Serial
(Class 2)
Operating time Between 2 to 5 hours • Wifi (optional)
Field Operation • Bluetooth (optional)
depending on the application
The Test Equipment shall be portable, The Test Equipment shall be able to
Charging time Approximately 7 hours from
battery operated and rugged for field download data to PC or compatible device
empty
operations. via standard interface or protocol:
Unit power input 12VDC, 60 Watt Max
The Test Equipment must be protected by
Power supply input 100 to 240 VAC, 50/60 bumpers.
Hz, auto-sensing
Power supply output 12VDC, 5 AMP Max
Specification Sheet
Test, Files and Data Storage Ethernet Framed Pattern Test
Report Generation - HTML, PDF, TXT, CSV, PRBS (2^11-1, 2^15-1, 2^20-1, 2^23-1, 2^31-1
Test Interfaces/Bit Rates
XML and inverse)
10/100/1000M Dual Port Capable
Ability to create a customized name All 1s, All 0s
Electrical
structure.
1:3, 1:7, 3:1, 7:1, 2 in 8
100M Ethernet Dual Port Capable
The Test Set UI supports a screen capture
Optical User defined
The internal storage capacity shall be at
GigE (Optical) Dual Port Capable MAC Frame Payload
least 1GB.
10GigE WAN Phy Dual Port Capable PRBS Pattern
Job Manager to push common job
(9.9G)
information into multiple test applications. Editable Digital Word
10GigE LAN Phy Dual Port Capable
Ability to create summary reports including Flow Control
(10.3G)
all tests performed in a job with pass/fail Emulation On/Off
verdict of each Interface Type
Pause Frames
Remote Operation RJ-45
Tx Insert
The Test Equipment shall be remotely SFP
controlled via Web browser. Pause Quanta - Definable
SFP+
In remote operation, the remote user can Pause Frame Analysis (counts etc)
SFP+Tunable
FTP files from the test set. Ethernet Generator
General
In remote operation, the remote user can Frame Type
FTP files to the test set. Line Rate Traffic Tx and RX for all Interfaces
802.3
The Test Equipment should not require the Single Stream Generation/Analysis
installation of client software on a PC for DIX
10 Streams Generation/Analysis
remote operation. VPLS with inner and outer MAC
Auto Discovery of Test Sets
Access via Smart Access Anywhere Codes MAC in MAC 802.1ah
Modes of Operation
Calibration EtherType Field-Editable
Terminate
Minimum calibration interval must be 3 MAC Addressing
years Monitor
Destination MAC Address - Unicast
Warranty Thru (Intrusive)
Destination MAC Address - Broadcast
The Product shall support a 3 year warranty Loopback
Destination MAC Address - Multicast
Included Items Half Duplex
Source MAC Address - User Defined
User manual Full Duplex
Source MAC Address - Auto Increment
AC Power Source Timing
MAC Frame Size
AC Power cords Recovered from Rx
64, 128, 256, 512, 1024, 1280, 1518
Optical Fiber Microscope Internal (Stratum 3)
User defined
The Test Equipment shall be able to accept Recoverd from External (BITs/SETs)
Jumbo (to 10k)
an optical video microscope with autofocus Freq Offset Transmit/Receive
capability. EMIX
Ethernet Features
The connector image shall be displayed on Random
the Test Equipment and saved into a .JPEG Layer 1 (Unframed) Bit Error Testing
Patterns VLAN
file format.
High Frequency test pattern VLAN Tagging 802.1q
The microscope shall offer a switchable
200/400x magnification capability. Low frequency test pattern VLAN Tag Editable Fields
• Priority
It shall be provided with the dedicated tips Mixed frequency test pattern
• VID
to connect to the patch panel or directly to
Random Data Pattern (RPAT) • VLAN Scan
the connector ferrule.
Jitter Tolerance Test Pattern (JTPAT) VLAN Stacking (Q-in-Q)
Saved Configurations
Supply Noise Test Sequence (SPAT) SVLAN Tag Editable Fields
Users shall be able to save test
configurations for future recall Layer 2 (Framed) Bit Error Testing SVLAN ID
Patterns
Users shall be able to transfer pre-defined SVLAN Priority
test configurations between test sets Compliant Random Data Pattern (CRPAT)
SVLAN DEI
Compliant Jitter Tolerance Pattern (CJPAT)
SVLAN TPID
Compliant Supply Noise Pattern (CSPAT)
Out of sequence frames Optional Testing with line rate LBM frames 1000M/100M/10M Electrical Tx/Rx
One Way Delay with GPS or CDMA receiver 1 KB TCP Window Size Granularity Packet Delay Variation Measurements on
Control Plane Traffic
ITU-T Y.1564 Jumbo Frame Support
Generate up to 4 streams of Background
10 Traffic Streams Graphical Results and Report Generation Dataplane traffic
Service Configuration Test Configurable File Sizes and Window Sizes Frame/Packet Capture and Decode via
Service Performance Test Total Test Time Display Wireshark
Committed Information Rate (CIR) Configurable Saturation Window Test Layer 2 1588v2 Messaging
Extended IR (EIR) Compatible with the following endpoints: Layer 4 1588v2 Messaging
Maximum IR (MIR) • T-BERD/MTS instruments Message rates Multicast: fastest 2/16/64/64
• QT-600 Ethernet Probes (DelayResponse/Announce/Sync/
Frame Loss Rate (FLR) • TrueSpeed VNF Server DelayRequest) ; slowest one message every
Frame Delay (FD) Layer 2 Transparency Testing 16 seconds
Frame Delay Variation Send/Receive Ethernet Control Plane Traffic Message rates Unicast: fastest 2/16/16/16
(DelayResponse/Announce/Sync/
Committed Burst Size (CBS) Encapsulation supported DelayRequest); slowest one message every
Policer Test • VLAN 16 seconds
• Q-in-Q
Round Trip Testing • Spanning Tree Support for Unicast and Multicast Address
Concurrent Bi-directional Testing • Cisco Protocols (Discovery etc.) Mode
• GARP Support for Forwardable and Non-
Configurable VLAN, Priority, Addressing and
• STP forwardable Address
Pass/Fail Thresholds
Programmable Pass/Fail Thresholds
Service disruption time Frame/Packet Size Binning OC-12 Dual Port Capable
PM-TIM Seconds Automated workflow is available at all OTN High frequency test pattern
rates for OTN Bulk Low frequency test pattern
PM-TIM Count
Set test duration based on Bit Error Rate Mixed frequency test pattern
PM-SAPI
Theory or actual time
PM-DAPI Random Data Pattern (RPAT)
Bit Error Rate Theory parameters for test
PM-Operator Specific Jitter Tolerance Test Pattern (JTPAT)
duration:
PM Round Tip Delay Recent • Data Rate (e.g. OTU4) Supply Noise Test Sequence (SPAT)
• BER Threshold Layer 2 (Framed) Bit Error Testing
PM Round Trip Delay Last • Confidence Level (% value) Patterns
FTFL Key automated tests Compliant Random Data Pattern (CRPAT)
Forward-Fault Type Payload BERT Compliant Jitter Tolerance Pattern (CJPAT)
Forward-SF Seconds • PRBS pattern selection
• Pass/Fail BER Threshold Compliant Supply Noise Pattern (CSPAT)
Forward-Operator Specific
Round Trip Delay Framed Pattern Test
Forward-Operator Identifier • Selection of applicable OH fields: PM, PRBS (2^23-1, 2^31-1 and inverse)
Backward-Fault Type TCM1-6
• Measurement Frequency All 1s
Backward-SF Seconds Count
• Pass/Fail Threshold (ms) All 0s
Backward-SD Seconds Count
GCC Transparency User defined
Backward-Operator Identifier • Selection of applicable OH field: GCC0,
GCC1 or GCC2 Fibre Channel Traffic Generation
Backward-Operator Specific
• Pass/Fail BER Threshold Transmit Traffic profiles
TCM 1-6
Report generation and formats Constant
IAE Seconds
Ramp
BIP Errors
Fibre Channel Bursty
BIP Error Rate
Traffic generation in Mbit/s and %
BDI Seconds Laser Type utilization
BIAE Seconds SFP Configurable Source and Destination ID
BEI Errors SFP+ Sequence ID
BEI Error Rate Modes of Operation Originator ID
TIM Seconds Terminate Responder ID
SAPI Monitor Frame length 28, 32, 76, 512, 1024,
DAPI Thru 1536, 2076, 2140,
User defined
Operator Specific Test Interfaces/Bit Rates
Packet payload
GCC BERT Bits 1.0625 Gbit/s Dual Port Capable
Granularity 1 to 6.7%
GCC BERT Bit Errors
Jitter Results per measurement band Maximum Peak-to-Peak TIE (MTIE) [s] 10GigE Optical Ethernet Interface
Current peak to peak jitter [UI] TDEV (Time Deviation) SIP, Cisco SCCP and H.323 Fast Connect
• Peak to peak jitter [UI] Frequency Offset (ppm) Supported SIP Parameters
• Positive peak jitter [UI]
• Negative peak jitter [UI] Drift Rate (ppm/s) Dial by phone/URL/e-mail
Maximum peak to peak jitter [UI] Masks Nortel & Huawei SIP emulation
• Peak to peak jitter [UI] ANSI SMC holdover (T1.105.109) Proxy login and proxyless operation
• Positive peak jitter [UI]
ETSI SEC (ETS 300 462-5-1) Supported SCCP Parameters
• Negative peak jitter [UI]
SEC network IF (ETS 300 462-3-1) Selectable Cisco Phone emulation
Phase Hits SSU (ETS 300 462-4-1) supporting at least 15 models
Percentage of mask SSU network IF (ETS 300 462-3-1)
Configurable device name
RMS Jitter [UI] GR253 SMC transient
Supported H.323 Parameters
Jitter Graphs
H.323 ID
Bearer Capability including Unrestricted
Wander Digital, Speech & 3.1K Audio
Configurable Calling & Called Party Number
General Features Plans and Number Types
Measure Wander on 1PPS Signal