System Curve (Red Color) One Pump 300

hL=35+0.002 Q^2 @1800 rpm


250
Q [gpm] h [ft] Q [gpm] h [ft] System h [ft]
0 35 0 100 35 200
110 59.2 110 90 59.2
180 99.8 180 80 99.8 150 h [ft]
250 160 250 60 160 System h [ft]
100
300 215 300 40 215
340 266.2 340 20 266.2 50

0
0 100 200 300 400

Two Pumps in Series 300


@1800 rpm
Q [gpm] h [ft] System h [ft] 250
0 200 35
110 180 59.2 200
180 160 99.8
250 120 160 150 h [ft]
300 80 215 System h [ft]
340 40 266.2 100

50

0
0 100 200 300 400

Two Pumps in Parallel 1200


@1800 rpm
Q [gpm] h [ft] System h [ft] 1000
0 100 35
220 90 131.8
800
360 80 294.2
500 60 535
600 h [ft]
600 40 755
680 20 959.8 System h [ft]
400

200

0
0 200 400 600 800