Download as pdf
Download as pdf
You are on page 1of 16
PDetector Handheld Partial Discharge Detector See Eee 2) PMDT Solutions for Condition-Based Maintenance Our Mission re eee et Cee Global Application ur products and services have been widel adopted by major electric tities and Industral end users throughout the United ee Geeta regions such as Canada Switzerland, Saudi ee ent ee eet or) Philippines, Thalland, Hong Ko ea ee eer} Peete fon ee eee re eid eee ee Manufacturing, Commercial Buildings, eo oT Coli im Ola( nce) eee eet rey PMDT PDetector o1 About PMDT PMDT provides solutions worldwide for condition-based maintenance to the power industry. Our company has knowledgeable and experienced personnel that utilize the most advanced resources for online testing. Over 20 years of ongoing research and development into power asset condition assessment aids for our wide array of diagnostic and monitoring systems for medium and high voltage substations, (Our headquarters and manufacturing facility is located in San Jose, CA, US, which provides local access to high quality American-made components, We provide reliable and robust equipment with, state-of-the-art capabilities for online testing of energized power equipme PMT meets 1509001: 2008 Quality Management System requirements and our products have passed laboratory tests and inspections Certifications: UL and CE certifications. PMDT continuously puts forth an abundant R&D investment to provide perpetually better solutions for condition-based PDetector Handheld Partial Discharge Detector Applications va stengear = eet ower cates "Gas Insulated Switchgear (61S) And other Equipment Main Features '=Employs 5 types of online PD sensor technologies "= PRPD, PRPS, Single-Cycle, Phase, Waveform, and Amplitude spectrums to determine PD types "Wireless connection to UHF and HFCT sensors 1» Powerflight frequency synchronization 1 Inceligent Patrol Function to create atest task with a set standard test procedure to improve test efiiency ‘= RFID asset tagging on power equipment to standardize the field OLPD testing procedure to greatly improve test eficiency and achieve asset management "= One-key data saving and simple operation, ideal for quick PD testing for a whole substation The PDetector is an ideal device for On-Line Partial Discharge (OLPD) testing of MV and HV equipment which employs all 5 types of OLPD sensor technology: Ultra-High Frequency (UHF}, Acoustic Emissions (AE), Ultrasonic, High Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV). The information from multiple sensors gives the PDetector the versatility to detect all types of PD in all types of substation apparatus. The exact type of PD activity can be determined effectively using multiple on-screen data spectrum analysis. The PDetector greatly simplifies and standardizes the routine OLPD testing procedure by using the intelligent patrol function, the ‘App, and the PMDTCloud, tis a very powerful and helpful tool for substation operators to conduct routine testing in a substation quickly, to determine what the issue Is, and where its located. Certifications f= The PDetector has WI+I capabilites It can communicate with the PMDTCloud via the PDetector App, download the test tas, and upon finishing testing, it also can upload the test data to the PMDTCloud, The PMDTCloud can give the diagnostic result by using the deep learning algorithm programmed into the PMOTCloud itself 1» Records upto 5 minutes of video while in the PRPS/PRPD Detection Modes ofthe UHF/HFCT Sensors '= PC-based data management software with automatic report {generation function in JPEG/MS Word/POF formats "On-board data storage 1» Environmentally friendly and supports papertess testing PMOT PDetector 02 Multiple Detection Modes and Data Spectrums LUHE PRPD-PRPS Spectrum AE Amplitude Spectrum =—- Hel” LAL : pig ede AE Waveform Spectrum HECT PRPD-PRPS Spectrum ‘AE Phase Spectrum PMDT PDetector 03 Data Management Software The PDetector data management software is a powerful, PC-based tool that stores, manages, and analyzes the test data, Main Features Builds a network tree which includes al of the monitored assets. = Generates analysis and management reports in formats automatically IPEG/MS Word/PDF = Manages historic data and produces PD trends. Wireless Sensor Connections and Frequency Synchronization Wireless Sensor Connection re Pea ere nd eee ae signals t eee through a light sensor on the signal processors. This allow ie oat eee pean Vicsea ae emaiee ee SMireneulr ttre Mio icecream eee Foe PMDT PDetector 04 PMDTCloud Asset Condition Monitoring Elare mB) F-laavelsiaie Data Management Wii 00] 2 Multiple Statistics Charts Shows the important information for users to understand the status of power equipment effortiessiy eS n ore Vstieli east Test Job Management Heer Manages and controls the online esting aire process of power equipment, long with : checking the progress ofeach test job in rel ea time, and also conducts test data management, Inquiry, and statistical analysis een e PMDT PDetector 05 PMDTCloud Test Point Management Standardize the test points for each OLPD test ‘method (TEV/Ultrasonic/AE/UHF/HECT), test at the same test point for each test method every time ‘with high efficiency, record and manage the test data, and conduct trend analysis. Cloud Diagnostic Function PMDT has developed the cutting-edge cloud diagnostic technology for the field testing data, based on big data mining and deep learning diagnostic algorithms. The testing data can be sent to the PMDTCloud for data analysis, and the Cloud provides diagnostics results with PD types automaticaly. This provides advanced and. reliable technological support for the status analysis of ower equipment. Automatic Reporting The PMDTCloud generates detailed, proficient test reports automatically ater the test data is uploaded ‘with one simple selection on the PMDTCloud webpage. Say goodbye to writing reports manually! PMDT PDetector 06 analysis i. A nd PMDT PDetector 07 The PMDT’s Field Test Procedure Innovative, Standardized, and High-Efficiency | Upload Test Data Load Test Jobs Data Analysis Intelligent 0 6 Test Instrument Data Collection 05 = z Field Test Send Back the Test Ly Intelligent Patrol Data endJob Files PMDT PDetector 08 2 Improve Test Efficiency and Condition-Based Asset Management with the Intelligent Patrol Function Are you stil performing OLPD testing the traditional way? Spending an extensive amount of time testing all the power equipment in the substations and recording the data by pen and paper? PMDT presents new, intelligent OLPD testing methods that will truly simplify your testing process! Create Electronic !Ds for Your Power Assets via RFID Tagging The RFID tags can be affixed to your power assets and store the power equipment information such as asset name, asst ID , substation name, and provides prompts for the appropriate ters for thatatset, Each teste recorded with a unique test ID number and date/time stamp to ensure reliability consistency and credibility RFID Patrol Function - Provides Efficiency by Utilizing the Internet of Things Following te routine patol procedure to perform fed testing wl vastly improve the testing efficiency, Use the Detector to scan the RFID tags and twill obtain the asset's information automaticaly. Allthe test data wil then be imbedded with the asset's information after the sean s complete, This allows the sytem to automaticaly identify and ink the data to each specifi asset. Detection Point ‘Smart RFID Tag No. 1630 Substation: © Sub Description: Feed to C-6 and (C7 Transformers 144 bemt Dedic. ‘Achieves accurate management of the asset's ID, physical status, and test point information. Standardizes the field OLPD testing procedure and retains the PD test data accurately, consistently, and comparably. d to Asset Management Test PD Environmentally-Friendly Eliminates the need to write down all the asset information and tet data withthe paperless OLPO testing realized with PMD’ innovative RFID function * Note: The intelligent Patrol function is supplied with the Detector. The RFID tags are additionally priced and programmed for your custom application. Please inquire {for more information. Configurations Main Unit Internal TEV Sensor Internal Ultrasonie Sensor LUHF Sensor with Wireless Signal Processor HFCT Sensor with Wireless Signal Processor ‘AE Contact Sensor Ultrasonic Parabolic Dish with Laser Sight Uitrasonic Extension Wand POetector Software ‘TeV Function Checker Vacuum Grease for the AE Contact Sensor ‘Magnetic Holder for the AE Contact Sensor Basic Headphones Battery Charger with Sync ‘Mini USB cable Coaxial Cables for UMF and HCT Sensors Carrying Case * Software Dongle Five Recommended Kits Configured with Optional Combinations of TEV, UHF, HFCT, AE, and Ultrasonic sensors Con rva TL dart Ca i Ce ec Multi-Function, Five-in-One, Kitt for ais, mv switchgear, Power Yovovo¥v v 4 a (Cables, and Transformers {AE/Ultrasonie, Tworin-One, Kit2 for Gis, MV Sultchgear, Cable y y ‘Accessories, and Transformers TEv/Ultrasonic, Two-in-One, Kit3 q " "9 for My Switchgear 2 7 xing UMEJTEV/AE/Ulratonig Fourinone, y z HECT/TEV/AE/UItrasonic, Four-in-One, tS for Power Cables and Transformers * Configurations and functions are customizable upon your request. PMDT PDetector aa. Technical Specifications Ercan acne Resuremene (0d8~70d8. aa Ep ve pea pa Communication Wie SRENGNE” aos weient 1.05 tb /0.48 ke Bandwidth 00kH~SOMHz ee cerns Tara ‘Accuracy #108 eel communion WARS SEER" fey ius Lc Accuracy #48 Spetng e 32°F~131°F / O°C~55°C RECanact Sensor 20k2-300KH Interna Battery ———_Uithiumion fie bitrasoMe Sensors 40KHe Operating Time Approx. 6 hours PMDT PDetector 12 Global Testing Experiences PMDT’s unique experiences consist of over 20 years of R&D combined with many years of field work: testing PD and Infrared for over 180,000 various power assets in thousands of substations globally for a variety of electric utilities, industrial end users, and power equipment manufacturers. PMDT has the expertise needed to provide the best Condition-Based Maintenance Programs for your power assets. PMOT PDetector 13: The PMDT Solution Solutions for Condition-Based Maintenance PMDTCloud Intelligent Asset Data Management Detection and Monitoring PMDTiSmart PDMonitor saya oe @ See a SY Geer co |S. z ohacion Ua & ut = Wireless Autonomous Permanent Online PD Online PORIR Testing Online PD Testing ‘Monitoring + + a Diagnostic and Location Short-Term Online PO Monitoring for Critical Assets PMDT PDetector 14 Solutions for Condition-Based Maintenance Power Monitoring and Diagnostic Technology Lid {6840 Via Del Oro, Suite 150 San Jose, CA:95119, USA Tel: +1 (408) 972-5588 Fax: #1 (408) 972-5678 Er ss powcincom ese © pMoT 2018 + Subject to change without prior notice www.powermdt.com

You might also like