Professional Documents
Culture Documents
1801 197 PDF
1801 197 PDF
Nortel Networks
OPTera Long Haul 1600
Optical Line System
1600G Amplifier Fiber Assist Tool Description
What’s inside...
Fiber Assist Tool
Copyright 2000 Nortel Networks, All Rights Reserved
The information contained herein is the property of Nortel Networks and is strictly confidential. Except as expressly authorized in
writing by Nortel Networks, the holder shall keep all information contained herein confidential, shall disclose it only to its employees
with a need to know, and shall protect it, in whole or in part, from disclosure and dissemination to third parties with the same degree
of care it uses to protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in
writing by Nortel Networks, the holder is granted no rights to use the information contained herein.
Nortel Networks, the Nortel Networks logo, the Globemark, How the World Shares Ideas, S/DMS TransportNode, OPTera, Preside,
and Unified Networks are trademarks of Nortel Networks.
Contents 0
About this document v
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
iv Contents
Audience
This document is for all users of the OPTera Long Haul 1600 FAST.
Network
16
Applications
00 R P
G
M
Supported
C
R
O
om r
Am s
ep
ea
bi
pl
ne
lu
ifi
te
er
r
Library Introduction, List of Terms, and Master Topical Index
-continued-
Network
16 OR r
Applications
00
G Plu
M
Supported
C
R
om r
Am s
ep
ea
bi
pl
ne
ifi
te
er
Maintenance
Supporting Documentation to the OPTera Long Haul 1600 Library (not part of this library)
323-1301-XXX OC-192 NTP Library
323-1321-XXX TN-64X NTP Library
323-1201-XXX OC-48 NTP Library
323-1211-XXX TN-16X NTP Library
450-3101-XXX Preside Documentation
NTR710AM Optical Networks Data Communications Planning Guide
NTCA65DA OPTera Connect DX NTP Library (OPTera Connect DX SONET platform)
NTCA65FA OPTera Connect DX NTP Library (OC-192 platform)
NTCA65GA OPTera Connect DX NTP Library (OPTera Connect DX SONET & OC-192 platforms)
NTCA65JA OPTera Connect DX NTP Library (OPTera Connect DX SDH platform)
NTCA65AC TN-64X Rel 3 NTP Library
NTCA65KA OPTera Connect DX NTP Library (OPTera Connect DX SDH & TN-64X platforms)
References
This document refers to the following application guide:
• Amplifier Network Application Guide (NTY314AX)
The Fiber Assist Tool guides you through the steps of connecting circuit packs
with fiber optics to create Optical Transport Repeater (OTR) topologies. For
additional information on the creation of OTR topologies, refer to
OPTera Long Haul 1600G Amplifier Network Application Guide,
NTY314AX.
Two screens are available in the Fiber Assist Tool: the variable selector screen
and the topology output screen.
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-2 Fiber Assist Tool
4 Direction
Select Direction
There are two main types of functions in the variable selector screen: variable
fields and function buttons.
Variable fields
There are six variable fields in the variable selector screen. Each field allows
you to select one of several variables. Each field is located in one of four
numbered areas in the screen. The following is a list of the variable areas and
the variable fields they contain:
Unit field
The Unit field allows you to select a slot position of a circuit pack, as shown
in the following example:
Figure 1-2
Unit selection
OTP1014
4 Direction
Select Direction
Card field
The Card field allows you to select a circuit pack, as shown in the following
example:
Figure 1-3
Card selection
OTP1015
4 Direction
Select Direction
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-4 Fiber Assist Tool
4 Direction
Select Direction
BypassType field
The Bypass Type field allows you to select between three types: no bypass,
dual amp bypass and full bypass, as shown in the following example:
Figure 1-5
Bypass selection
OTP1017
4 Direction
Select Direction
Bypass is not available for line sites. If you choose Line in the site type field,
the following message appears when you click on the execute button:
Figure 1-6
Bypass warning
OTP1019
4 Direction
Dir1
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-6 Fiber Assist Tool
Direction field
The Direction field allows you to select the direction of the optical signal, as
shown in the following example:
Figure 1-8
Direction selection
OTP1021
4 Direction
Select Direction
Dir1
Dir2
Function buttons
There are two function buttons available from the variable selector screen:
execute and reset. They are at the right side of the screen, as shown in the
following example:
Figure 1-9
Function buttons
OTP1022
4 Direction
Select Direction
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-8 Fiber Assist Tool
Execute
The execute function processes the selections you make in the variable selector
screen. Click on the execute button to proceed to the next screen, the topology
output screen. All variable fields require a selection in order to use the execute
function and proceed to the next screen. If you do not select a variable from
each field, a warning message like the one below appears:
Figure 1-10
Execute function warning
OTP1023
4 Direction
Select Direction
Reset
The reset function allows you to reset all variable fields to default status. The
screen returns to the same state as when you first log into the Fiber Assist Tool.
(See Figure 1-1)
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
• topology description
• step navigational buttons
• step description
• main shelf circuit packs
• extension shelf circuit packs
• function buttons
• connection legend
• slot description
• Mid-stage access (MSA) description
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-10 Fiber Assist Tool
Topology description
This area contains information about the following: unit, cards, OSC, site type,
direction and bypass. This area displays the selections from the variable
selector screen.
Figure 1-12
Topology description
OTP1024
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
The <<First button returns you to the first step. The <Prev button returns you
to the previous step. The Next> button displays the next step. The Last>>
button brings you to the last step. When you click on any of these buttons, the
connection symbols change in the areas at the bottom of the topology output
screen.
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-12 Fiber Assist Tool
Step description
This area describes the connection steps you request in the variable selector
screen. The step description contains the following elements:
• current step
• total number of steps
• description of current step
Figure 1-14
Step description
OTP1026
Unit: G0 Cards: DAMP + 2 BOOSTER18 New connection
Back Established connection
OSC: BI OSC Site Type: Line Direction: Dir1
Unused connector
Bypass: No Bypass
<< First < Prev Next > Last >>
Step 1 of 10 : Dir 1's upstream fiber to IN-1
Slot Number : 1 2 3 4 5
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
As you navigate between the steps, the number of the current step (in the above
example: step 1 of 10) and its description change until you reach the final step.
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
When the connection steps do not apply to a circuit pack, the entire large box
is grey-filled. As you navigate between steps, the small boxes change color
(see Connection Legend section on page 1-16).
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-14 Fiber Assist Tool
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
When the connection steps do not apply to a circuit pack, the entire large box
representing that circuit pack is grey-filled. As you navigate between steps, the
small boxes change color (see Connection Legend section on page 1-16).
Function button
This area consists of the back function, as shown in the following example:
Figure 1-17
Function Button
OTP1029
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-16 Fiber Assist Tool
Connection legend
This area is a guide to the connection procedures to which the steps pertain.
The legend consists of symbols representing the following elements:
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
When you view the next step, the previous blue-filled box is now a grey-filled
box with a large X in it, as shown in the following example:
Figure 1-19
Connection legend - next step
OTP1031
Unit: G0 Cards: DAMP + 2 BOOSTER18 New connection
Back Established connection
OSC: BI OSC Site Type: Line Direction: Dir1
Unused connector
Bypass: No Bypass
<< First < Prev Next > Last >>
Step 2 of 10 : 1510nm ADD to UPB-1
Slot Number : 1 2 3 4 5
1510 1480 1480-A IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB
DROP ADD 1510-D
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
If you view the previous step, the grey-filled box becomes a blue-filled box, as
in Figure 1-18.
Slot description
The slot description represents the location of the circuit packs on the main
shelf and the first extension shelf (Fig. 1-20).
Figure 1-20
Slot description
OTP1032
Unit: G0 Cards: DAMP + 2 BOOSTER18 New connection
Back Established connection
OSC: BI OSC Site Type: Line Direction: Dir1
Unused connector
Bypass: No Bypass
<< First < Prev Next > Last >>
Step 1 of 10 : Dir 1's upstream fiber to IN-1
Slot Number : 1 2 3 4 5
Right Carrier Left Carrier
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
1600G Amplifier Fiber Assist Tool Description 323-1801-197 Rel 3 July 2000
1-18 Fiber Assist Tool
The slot numbers change according to the variables you select in the variable
selector screen.
IN-2 OUT-2 UPA-2 UPB-2 INTLV UPB INTLV UPB INTLV UPB INTLV UPB
DAMP 2A
IN MSA 1AB OUT IN MSA 2AB OUT IN MSA 1BC OUT IN MSA 2BC OUT
Note: For reference, illustrations of OSC and DAMP circuit packs can be
found in the OPTera Long Haul 1600G Amplifier Network Application
Guide, NTY314AX.
323-1801-197
Rel 3 Standard
July 2000