Calibration tube properties
ID OD
mm mm
60.3 73.0
76.2 101.6
207E+06 kPa
oisson's coefficient: 0.2
Disclaimer
Roctest makes no warranty as to this Excel file and
assumes no liability with regards to its use. It is furnished
with the sole purpose
of better assisting Roctest's clients.
Membrane stiffness
Information on the test Raw test data
calibration
Ref number: cal06
Test depth: 9.00 m Pressure Volume Pressure Volume
Test number: SK-8 Bar cm³ Bar cm³
Probe size: B 0 0.0 0 0.0
Use of a slotted casing: No 1 140.0
2 200.0
For a B probe: 3 350.0
Th. diameter 58 mm 4 462.0
Th. length 21 cm 5 585.0
Th. volume 535 cm³ 6 710.0
ID tube 60.325 mm
OD tube 73.025 mm
Calculated coefficients
a 3.100 cm³/kPa
b 0.00003 cm³/kPa
Volume correction
Apply volume correction? No
Nb points 1 Nb points
Nb used 2 Nb used
### Err:502 Err:502 125000
### #VALUE! #VALUE! 600
0 0 a
A Err:502 cte not used
B Err:502
C Err:502
Volume calibration Corrected test data
Intermediary calculations
P0 Corrected
DP pressure
Volume Index Pressure Volume
cm³ kPa kPa kPa kPa cm³
0.0 1 0 0 93 93 0.0
102.0 1 0 0 193 193 140.0
218.0 1 0 0 293 293 200.0
350.0 1 0 0 393 393 350.0
505.0 1 0 0 493 493 462.0
660.0 1 0 0 593 593 585.0
#N/A 1 0 0 693 693 710.0
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
245.0 #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
6
3
600
3
318500
1515
800.0
ected test data
DR/R0 700.0
%
0.00
12.32
Volume (cm³)
17.21 600.0
28.62
36.51
44.69 500.0
52.55
#N/A
#N/A
#N/A 400.0
#N/A
#N/A
#N/A 300.0
#N/A
#N/A
#N/A
#N/A 200.0
#N/A
#N/A
#N/A 100.0
#N/A
#N/A
#N/A
#N/A 0.0
#N/A 0 100 200 300 400
Pressure (kPa)
Raw test data
Membrane stiffness calibration
Volume calibration
Corrected test data
Volume (cm³)
93 0.0 0.00 293 200.0
193 140.0 12.32 800.0 493 462.0
293 200.0 17.21 x
393 350.0 28.62 700.0 PL & VL or DR/R0 plots
493 462.0 36.51 x
593 585.0 44.69 600.0 693.157 5
693 710.0 52.55 Pressure Volume
#N/A #N/A #N/A 500.0 kPa cm³
#N/A #N/A #N/A 899 0.0
#N/A #N/A #N/A 899 935.0
400.0
#N/A #N/A #N/A 0 935.0
#N/A #N/A #N/A 899 935.0
#N/A #N/A #N/A 300.0
#N/A #N/A #N/A
#N/A #N/A #N/A 200.0
#N/A #N/A #N/A
#N/A #N/A #N/A 100.0
#N/A #N/A #N/A
#N/A #N/A #N/A 0.0
#N/A #N/A #N/A 0 100 200 300 400 500 (kPa)600
Pressure
#N/A #N/A #N/A
#N/A #N/A #N/A
#N/A #N/A #N/A E= 1,758
#N/A #N/A #N/A VL = 935.0
#N/A #N/A #N/A Suggested poly order: 3
Suggested PL = 899
stic segment Elastic segment Plastic zone
eter test
metric - corrected
units) curve (metric units) (imperial units) (interpolated - metric units)
25
DR/R0 Pressure Volume DR/R0 Pressure
% psi in³ % kPa
17.21 43 12.2 17.21 693
36.51 72 28.2 36.51 702
710
719
VL or DR/R0 plots PL & VL or DR/R0 plots
727
100.5339232 736
DR/R0 Pressure Volume DR/R0 745
% psi in³ % 753
0.00 130 0.0 0.00 762
65.76 130 57.1 65.76 770
65.76 0 57.1 65.76 779
65.76 130 57.1 65.76 787
796
804
813
822
830
839
847
0 300 400 500 (kPa)600
Pressure 700 800 900 1000 856
864
873
kPa 255 psi 882
cm³ 57.1 in³ 890
899
kPa 130 psi
Plastic zone Plastic zone
(interpolated - metric units) (interpolated - imperial units)
8.56
Volume DR/R0 Pressure Volume DR/R0
cm³ % psi in³ %
710.0 52.55 101 43.3 52.55
720.5 53.19 102 44.0 53.19
731.0 53.83 103 44.6 53.83
741.3 54.46 104 45.2 54.46
751.7 55.08 106 45.9 55.08
761.9 55.70 107 46.5 55.70
772.1 56.31 108 47.1 56.31
782.2 56.91 109 47.7 56.91
792.1 57.50 110 48.3 57.50
802.0 58.09 112 48.9 58.09
811.8 58.66 113 49.5 58.66
821.5 59.23 114 50.1 59.23
831.1 59.79 115 50.7 59.79
840.5 60.35 117 51.3 60.35
849.9 60.89 118 51.9 60.89
859.1 61.42 119 52.4 61.42
868.1 61.95 120 53.0 61.95
877.0 62.46 122 53.5 62.46
885.8 62.96 123 54.1 62.96
894.4 63.46 124 54.6 63.46
902.9 63.94 125 55.1 63.94
911.2 64.41 127 55.6 64.41
919.3 64.87 128 56.1 64.87
927.2 65.32 129 56.6 65.32
935.0 65.76 130 57.1 65.76
Extrapolation of the test - use of polynomial method
693
olynome order used: 3 876
898
a3 4.3522E+11 899
a2 713415430 899
a1 1204581.799 899
a0 2107 899
a-1 3.837598068 899
a-2 0.007304392 899
a-3 1.45463E-05 899
899
899
899
899
899
899
899
899
899
899
899
G-AM Pressuremeter Test
900.0
Volume (cm³)
800.0
700.0
600.0
500.0
400.0
300.0
200.0
100.0
0.0
0 100 200 300 400 Pressure
500 (kPa) 600 700 800 900 1000
50.0
40.0
30.0
20.0
10.0
0.0
0 20 40 60
Pressure (psi) 80 100 120 140
Pressure (kPa)
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A 700
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
600
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A 500
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A 400
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A 300
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
200
100
0
Calibration Sheet Reference 0.00 10.00 20.00 30.00 40.00
DR/R0 (%) 50.00 60.00 70.00
Test Results
Pressure (psi)
#N/A #N/A #N/A #N/A #N/A #N/A 100
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
80
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A 60
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A 40
#N/A #N/A #N/A #N/A #N/A #N/A
20
0
Calibration Sheet Reference 0.00 10.00 20.00 30.00 40.00
DR/R0 (%) 50.00 60.00 70.00
Test Results
Calculated coefficients
c= 3.100 cm³/kPa
Calculated coefficients
c= 1.304 in³/psi
Calculations are done in accordance to ASTM D 4719-00 Standard using the process for volume-measuring presuremeter.
The raw test data are corrected to compensate for membrane resistance, system compressibility and the hydraulic head
between the control unit and the probe.
Where:
Em = Pressuremeter modulus
v = Poisson's ratio
Vo = Theoretical volume of the measuring portion of the uniflated probe at 0 volume reading at the ground surface
Vm = Corrected volume increase at the center of the ΔV volume increase
ΔP =Corrected pressure increase in the linear zone of the pressure-volume curve between P1 and P2
ΔV =Corrected volume increase in the linear zone of the pressure-volume curve between P1 and P2
P = Pr + Pl - Pc
P = Corrected pressure.
Pr = Pressure reading on the control unit.
Pl = Hydrostatic pressure between control unit and the probe.
Pc = Pressure correction for the stiffness of the instrument at corresponding volume; determined with the pressure calibration.
V = Vr - Vc
V = Corrected volume.
Vr = Volume reading on the control unit.
Vc = Volume correction for the volume expansion of the instrument during the test; determined with the volume calibration.
The limit pressure (PL) is determined with a polynomial tendancy curve. Many methods can be used for determining the P L.
According to us, the best one consists in estimating this pressure by eye. If the tendancy curve does not yield satisfactory
results, the user must proceed to necessary adjustments.
Vc is obtained with a volume correction factor "c" given by the following equation:
c=a-b
The correction factor "a" is calculated from the linear part of the curve of the calibration in the steel tube.
The "b" parameter takes into account the expansion of the steel tube during the calibration and is calculated with following
equation:
b = (2V * (r + e * (1 + m))) / Em * e
Where:
V = Volume of the probe when in contact with the metallic calibration tube
r = Internal radius of the calibration tube
e = Wall thickness of calibration tube
m = Poisson's ratio of calibration tube material
Em = Modulus of elasticity of calibration tube material
Disclaimer
The Roctest company makes no warranty as to this Excel Macro and assumes no liability with regards to its use. It is
furnished with the sole purpose of better assisting Roctest's clients.
V = Volume of the probe when in contact with the metallic calibration tube
r = Internal radius of the calibration tube
e = Wall thickness of calibration tube
m = Poisson's ratio of calibration tube material
Em = Modulus of elasticity of calibration tube material
Disclaimer
The Roctest company makes no warranty as to this Excel Macro and assumes no liability with regards to its use. It is
furnished with the sole purpose of better assisting Roctest's clients.
or volume-measuring presuremeter.
pressibility and the hydraulic head
een P1 and P2
en P1 and P2