NOTES:

ARAMCO.
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE INDICATED.
M

SAUDI
2. FOR FIRE GENERAL NOTES, LEGENDS AND NOTES
A
K
K
REFER DRAWING RA-620026-001.
A
H

3. FOR TYPICAL STANDARD DETAILS REFER TO


P&ID reference to be mentioned in the

OF
DRAWING RA-620694 SHEET NO. 001, 002, 003

N
Notes AND 004.

CONSENT
4. THIS DRAWINGS IS EXTRACTED FROM MODEL
MYDP-6CS-C410-M3-F-000001.

WRITTEN
THE
WITHOUT
CRITERIA FOR THE DESIGN OF THE SPRINKLER SYSTEM

DRAWING
Provide dimension for distance between sprin-
kler(Typical), distance between supports,BOP
DESIGN STANDARD NFPA 13:2016
for branch (TYP), Elevation
Ø50 Ø25 SPRINKLER K-FACTOR 115 L/MIN/(BAR) 1/2

THIS
Ø32 Ø65 SPRINKLER THERMAL SENSITIVITY STANDARD RESPONSE
⌀25 TEST LINE WITH TEST VALVE AND
SPRINKLER COVERAGE (STANDARD/EXTENDED) STANDARD COVERAGE

FROM
SMOOTH BORE, CORROSION RESISTANT Ø80
Ø25 BOP 12270
OUTLET GIVING FLOW EQUIVALENT TO ONE
Assign support numbers for each sup- SPRINKLER TEMPERATURE RATING ORDINARY (57-77 DEG CELSIUS)
SPRINKLER
BOP 12270 Ø100 ports & provide reference for support

OBTAINED
INSTALLATION ORIENTATION SEE PLANS AND LEGENDS
drawings
BOP 12330 TYPE OF SYSTEM WET

UPRIGHT SPRINKLER AREA PROTECTED BY EACH SYSTEM RISER < 3720 SQM
Ø150
(TYPICAL) E
US OCCUPANCY CLASSIFICATION PW AND FW PUMP STATION

BE
HO
MP BOP 12360
Ø150
PU

SHALL
W Ø100
&F
P W 150MM DIA ALARM CHECK VALVE HYDRAULIC CALCULATIONS

LOCATION OF THE HYDRAULICALLY


GRID A TO B & 3 TO 8

PART,
MOST DEMANDING AREA
⌀150 PIPE CONNECTED
TO FIRE PUMP DISCHARGE HEADER OCCUPANCY CLASSIFICATION FOR THE LEGEND:
Upright sprinkler installation details are not EXTRA HAZARD GROUP 2
(REFER DWG.NO.:RA-631308-001)

IN
HYDRAULICALLY MOST DEMANDING AREA
clear . Either TEE with 25. mm outlet or TEE SPRINKLER PIPE
Ø65

OR
with 13 mm outlet BOP 6870 DESIGN DENSITY 16.3 L/MIN
UPRIGHT SPRINKLER

FULL,
Ø80 AREA OF THE HYDRAULICALLY MOST
963-C41001-ACV-60001 232 SQM
Ø25 DEMANDING AREA ZCV ZONE CONTROL VALVE
(TYPICAL)

IN
BOP 4180 Ø50
NUMBER OF THE HYDRAULICALLY MOST
(TYPICAL) 32 ACV ALARM CHECK VALVE
Ø32 DEMANDING SPRINKLERS

REPRODUCTION
(TYPICAL)
Ø25 SPRINKLER MINIMUM RESIDUAL PRESSURE 1.15 BAR
REFERENCE DRAWINGS
⌀32 DRAIN PIPE (TYPICAL)
SPRINKLER DESIGN/CALCULATED FLOW 5063 L/MIN
TO TRENCH DRAIN GROUND FLOOR AND ROOF PLAN RA-610448-001
INSIDE HOSE STREAM ALLOWANCE 0 L/MIN LIFE SAFETY PLAN - GF RA-610451-001
SITE PLAN RA-610447-001
TOTAL FLOW (SPRINKLER+HOSE ALLOWANCE) 5063 L/MIN ELEVATIONS RA-610449-001

NO
RESULTING PRESSURE AT BUILDING TIE-IN POINT 3.718 BAR GF ANDRF FIRE PROTECTIONPLAN RA-620576-001

ARAMCO.
KEYPLAN

SAUDI
THIS BUILDING

A FIRE FIGHTING ISOMETRIC VIEW

OF
SCALE

PROPERTY
SOLE
THE
N
ARE
0 10.0 20.0 30.0

HEREIN
METERS

SCALE: NTS

CONTAINED
REVISION VALIDATION

THIS REVISION NO. A IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

25-00053-0006-222

INFORMATION
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
FA/DK UFA SEPCO
12/22/19 12/22/19

REV.NO. DATE REVISION DESCRIPTION

A 12/22/19 ISSUED FOR 90% DESIGN

JOB ORDER/EWO NO.

THE
THIS REVISION IS NOT TO BE USED FOR
25-00053-0006 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY

AND
FIRE FIGHTING ISOMETRIC VIEW
DRAWING TYPE

FPS

DRAWING
PW AND FW PUMP STATION (C-410)
SHIPBUILDING
RAS AL KHAIR SAUDI ARABIA
UNIT NO. PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THIS
C410 963 B RA-620575 001 A
Saudi Aramco 2615 ENG. (05/05)

CAD CADD-05