ALWAYS perform the start up procedure with the first installation and when the card reader
has been replaced! Do not connect the TSM connector to the CPK+ yet.
Connect the TSM only when the display shows you to connect the TSM.
Start the TMD Utility. The Device info will display No Connection
The TMD Utility has searched for a connection with the CPK+ but could not find it.
Now connect the USB to the CPK+ Unit and plug the USB connector in a laptop or PC.
Put the 24V power cable in the CPK+ main board.
Make sure the TSM is NOT connected to the CPK+ yet.
When the CPK+ is connected you can see information in the Device info section.
For an optimum protection of the CPK in combination with the different types of ATM’s, the
following settings needs to be selected:
- RD mode only for Diebold Opteva ATM’s with motorized card readers.
- RV mode for all other ATM’s with motorized card readers.
- (RS mode is only for ATM’s where the cards can be inserted on several ways when a CPK is
connected).
Redo the start up procedure when “TSM.dis.” appears on the CPK+ display.
Door switch
The door switch has been developed to prevent false alarms during maintenance of the ATM.
When the ATM door is open the SDK is standby.
When the door is closed the SDK starts initializing again and audible beeps will be generated as
during the start-up!
Before collecting any Log file wait until the Device Info field is filled
with CPK+ information and that the SDK Level Indicator is switched off.
Press “Get Logs” 1 to get the log files of the CPK+. (15000 lines can be kept, after that first in
first out rule is applied)
If Logs needed to be kept, press “Save Logs” 2
If more SDK Sensors are installed choose from the drop down list and select.
U
Sometimes you have to click a button more than once, the processors could be busy at
that moment, not executing that command.
This section gives the option to change the default settings of the CPK+.
Changing this should only be done for demonstration purposes.
Under no circumstances other than approved by TMD Security GmbH may the changed CPK+ be
used in the field.
TMD Security GmbH is not liable for errors and damages resulting when changing any of the
default settings on the CPK+.
CPK 2
MCRW Relay
(Power Cut to CRD)
Alarm Relay
(Dry-contact relay NO/NC/Com)
SDK 3
MCRW Relay
(Power Cut to CRD)
Alarm Relay
(Dry-contact relay NO/NC/Com)
TVK 4
MCRW Relay
(Power Cut to CRD)
Alarm Relay
(Dry-contact relay NO/NC/Com)
CPK Type 6
Dropdown list to change the CPK Mode.
Duty Cycle 7
Dropdown list to change the TSM signal, only for RV Mode. Press “Update” 8 to activate the
changes.
When finished changing the configuration the CPK+ needs to be restarted to begin
using the new configuration. ( Utility Tab press “Restart” 4 to restart the CPK+.)
U U
This section describes how to quick check if the CPK is functioning correctly:
In case a CPK is not functioning at all first check step by step if the installation has been done correctly
conform the installation manual and if the CPK has been configured in the correct mode.
If the display of the CPK , and the control LEDS, do not give any indication, check if the CPK gets
power from the ATM. Causes could be ATM power down, defective power supply from ATM, defective
power cable to CPK as result from damage, or ATM does not get power from power socket.
In case the CPK gets power from its power cable but does not show any information , either on the
LED’s or display, the responsible person for maintaining the ATM is requested to contact TMD Security
for a solution.
When the CPK display indicates information on the LCD, a Laptop computer can be connected to the
CPK to use the Utility software to read the log file from the CPK.
The contents of the log file must be checked for the following messages:
cpk1 Tdis
The cpk1 Tdis message appears on the CPK+ display when the TSM
appears to be disconnected. The CPK+ will block the power to the Card Reader.
Solution:
cpk1 Tlow
cpk1 Thig
cpk1 Terr
In case one of these messages appears in the log file the responsible person for maintaining
the ATM is requested to contact TMD Security for a solution.
These messages indicate a problem with one of the sensors of the CPK :
sdk2 err
sdk2 St.Er
tvk1 err
atk1 err
In case one of these messages appears in the log file the responsible person for maintaining
the ATM is requested to contact TMD Security for a solution.
Version conflict on the LCD panel of the CPK : In this case an incorrect firmware file has been
downloaded in the CPK.
In case this message appears in the log file the responsible person for maintaining the ATM
is requested to contact TMD Security for a solution.
If the logfile contains csw ins or csw err messages, these messages are related to the card switch of
the card reader. Either a card was in the CES for a longer period or the card reader was replaced
without following the startup procedure correctly.
If the log file does not show any of these messages, but a problem still exists, you are requested to
send the log file together with description of the problem to
Support@TMDSecurity.com
Always include the serial number of the cpk in your email. When the cpk is still working the serial
number can be retrieved with by sending the sn command in the utility software. The serial number is
also indicated on the back of the cpk on the aluminum gray sticker. It is a 12 digit number after the
characters S.N.