S-18 - Bunkering Checklist
S-18 - Bunkering Checklist
S-18
Date :08/2008
Revision No. 2 / Page 1 of 2
Bulk + Other Cargo
BUNKERING CHECKLIST
VESSEL’S NAME………………………………….
PORT…………………………… DATE……………..
Prior to bunkering:
Check hose is of sufficient length.
Inspect hose and couplings for damage.
Check weight of hose does not exceed SWL of vessel's lifting gear.
Place drip trays under hose couplings and flanges.
Check delivery note quantity and specification are correct.
Discuss bunkering plan with supplier.
Discuss vessel's emergency response procedures with supplier.
Discuss supplier's own emergency response procedures.
Establish communication link between vessel and supplier.
Agree signalling system with supplier Commence Pumping.
Reduce Pumping Rate.
Cease Pumping.
Emergency Stop.
During Bunkering:
Commence bunkering at minimum pumping rate.
Monitor supply line pressure.
Examine hose connections for leakage.
Reduce pumping rate and/or open next tank before topping up.
Close valves as each tank is completed.
Witness, date, jointly countersign & retain sealed bunker samples.
Ensure sufficient ullage in final tank for hose draining/line blowing.
Notify supplier when final tank is reached.
Give suppliers timely warning to reduce pumping rate.
Give suppliers timely warning to stop pumping.
Drain hoses on completion of bunkering and close all filling valves.
On Completion of Bunkering:
Ensure all hoses are fully drained.
Close and blank off manifold connection.
Blank off disconnected hose couplings.
Reconfirm all bunker line and tank filling valves are secured.
Reconfirm all bunker tank surroundings.
Sight, agree and record shore/barge meter readings.
Verify all bunker receipt details are correct.
Complete entry in Oil Record Book.