Professional Documents
Culture Documents
Photocell SElcon PDF
Photocell SElcon PDF
BAK
ERY
As a pioneer in the production of photo controls, KAGA, INC. has been highly appraised
by the industry with its reliable products based upon its expert technologies and 50
years experiences. KAGA's product line includes the AS Series (thermal relay type) and
the PS,SS Series (solid state type), and a variety of models to satisfy consumer's require-
ments.
KAGA offers a range of LED street lighting that is bright and stylish in design, offers
excellent functionality and value for money and has a low maintenance requirement
and cost.
By combining emerging style and present technology, KAGA can integrate solar energy
with a chic, low power, low cost and environmentally friendly lighting solution.
LEDEEMA stands for LED + Excellence + Evolution + Mastery. KAGA has given this name
hoping to keep evolving its LED street lights with excellent technical knowledge and
services, and wishing to make mastered products praised by everyone.
MARK OF QUALITY
/
PHOTO CONTROLS
1
PHOTO CONTROLS /
TYPE NUMBER HOW TO CONNECT PHOTO CONTROLS
The type number symbolizes the rating and performance.For example. Lead wire black to electric power source
AS-2203A
Lead wire white to common
Lead wire red to lamp(load)
For HID, FL.lamp For incandescent lamp,LED
Type: P,and Q for built-in type. A or EC for lead-in type.
D for plug-in type.
KAGASEL KAGASEL
Current: 03 for 3A. 06 or 10 for 6A or 10A.
Voltage rating: 10 for 100V.11, 20, 22 or 24 for 110V, Black Red LAMP Black Red LAMP
200V, 220V or 240V,respectively. White White
L L
AS: Thermal relay type. PS,SS: Solid state type.
BALLAST
AS SERIES
■ Dimensions AS-1103A (110V,3A)
Lead-in Type AS-2203A (220V,3A)
3A / 6A AS-2403A (240V,3A)
Type
AS-1106A (110V,6A)
MADE IN JAPAN AS-2206A (220V,6A)
AS-2406A (240V,6A)
IP33 ON:10-80 lx OFF:Not more than 400 lx
MADE IN JAPAN
MADE IN JAPAN
■ Dimensions AS-2403P3(240V,3A)
Built-in Type
P Type
2
K?P?RFMLAJ
/..ik
S@
SS/PS SERIES
Do lin the li e o s itchin operation hen compared ith the thermal rela t pes
Decreasin po er cons mption
perates sin a li ht ith a lo l mino s intensit can sa e ener cons mption
■ Dimensions SS-2410D(240V,10A)
Plug-in Type
ø74
D Type
56
66
IP23
ø80
Nema type l FF l
■ Dimensions PS-2403P1(240V,3A)
Built-in Type l FF l
P Type
PS-2403P2(240V,3A)
l FF l
S ita le or the se in
street l minaires,
endin machines, etc
■ Dimensions PS-2203Q(220V,3A)
Built-in Type 26 23
(50)
24
PS-2403Q(240V,3A)
Q Type M16
φ24
50
More than 150
RECEPTACLE
■ Dimensions ■ Dimensions
Receptacle φ65 Receptacle 2-ø3.4
40
34
115
24 14
MADE APA MADE APA
18
72.5
30 22
5
23 18
5
20 80
A ick connectin t pe
Applica le to SS D Applica le to AS P , PS P ,PS P
PHOTO CONTROLS /
AS-Series
(Thermal relay type)
MAXIMUM LOAD
1 ON and OFF operations are performed by sensing of
WEIGHT light levels.
TYPE RATING INCAN- LED/FLUORESCENT LAMP/
DESCENT MERCURY VAPOR LAMP (g) 2 Random switching due to cloud shadow and such
LAMP(W) (VA) stray light as automobile head light is eliminated by
AS-1103A 110V 3A 300 300 50 using the thermal relay.
AS-1106A 110V 6A 600 600 51
3 Durability and reliability are not affected by change
of temperature and external mechanical forces.
AS-1110A 110V 10A 1,000 1,000 80
4 Small power consumption. Operates either by 50Hz
AS-2203A 220V 3A 600 600 50 or 60Hz.
AS-2203EC 220V 3A 600 600 106 5 The direction on the lighting side can be changed
AS-2206A 220V 6A 1,200 1,200 51 by an easy direction adjustment, the influence from
light other than natural light can be decreased.
AS-2206EC 220V 6A 1,200 1,200 106
PS,SS-Series
(Solid state type)
MAXIMUM LOAD
1 Photo IC is used for the sensor.
WEIGHT 2 High sensitivity and small ratio of ON and OFF levels,
TYPE RATING INCAN- LED/FLUORESCENT LAMP/
DESCENT MERCURY VAPOR LAMP (g) so that electric power consumption is minimized.
LAMP(W) (VA) 3 Small power consumption.
PS-2203Q 220V 3A 600 600 39 4 Rapid response makes possible easy testing of
4
LED LUMINAIRES
5
LED LUMINAIRES
KLE-128-19/KLE-128-26R
■ Light Distribution
KLE-128-19
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚) unit : cd/1000 lm
KLE-128-26R
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚) unit : cd/1000 lm
■ Dimensions
221 376
140
100
KLE-132-35R
■ Light Distribution
KLE-132-35R
unit : cd/1000 lm
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚)
■ Dimensions
145 470
255
■ Basic Performance
Input Power Luminous Luminous Color
Model Standard Weight Voltage Lamp Life
Lamp Housing Cover Color Current Consumption Flux Efficiency Temperature
Name (kg) (V) (hr)※1
(A) (W) (lm) (Im/W) (K)
unit : cd/1000 lm
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚)
■ Dimensions
221
531
130
KLE-126 series require an arm separately for installation. (Adaptable arm diameter:ø34.0mm)
KLE-130-59L
■ Light Distribution
KLE-130-59L
unit : cd/1000 lm
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚)
320
■ Dimensions
320 640
116
640
KLE-130 series require an arm separately for installation. (Adaptable arm diameter:ø48.6 or ø60.5mm)
116
■ Basic Performance
Input Power Luminous Luminous Color
Model Standard Weight Voltage Lamp Life
Lamp Housing Cover Current Consumption Flux Efficiency Temperature
Name Color (kg) (V) (hr)※1
(A) (W) (Im) (Im/W) (K)
220 AC 0.145
KLE- LED 1W type Acrylic
ADC Silver 4.4 31 2,844 91.7 60,000 5,000
126-31R ×31 Resin
240 AC 0.135
220 AC 0.290
KLE- LED 2.2W Acrylic Grayish
ADC 7.0 59 4,920 83.4 60,000 5,000
130-59L type×24 Resin Black
240 AC 0.265
NEW
KLE-137 series require an arm separately for installation. (Adaptable arm diameter: ø34.0, ø48.6 or ø60.5mm)
■ Light Distribution
Polar Curve
KLE-137-52L KLE-137-52L
(Wide type(Standard)) (Area type) KLE-137-81 KLE-137-92
90 90 90 90 90 90 90 90
100
100 100 100
200
400
A A 300 A 300 A 300
500 30 30 30 30
30 30 30 30
600 400 00 400
unit : cd/1000 lm unit : cd/1000 lm unit : cd/1000 lm unit : cd/1000 lm
B
B
B
B
■ Features ■ Dimensions
Optical Versatility (※KLE-137-52L only) 300
Light distribution patterns are variable.
KLE-137-52L provides two different light distribution patterns, allowing the choice between
wide and area type in accordance with installing sites.
Adjustable for three different size of mounting arms, ø34.0, ø48.6 or ø60.5mm.
(135.5)
Having structure to maintain the center of line of mounting arm, the outer appearance is
enhanced when the luminaire is installed.
■ Basic Performance
Input Power Luminous Luminous Color
Model Standard Weight Voltage Lamp Life
Lamp Housing Cover Current Consumption Flux Efficiency Temperature
Name Color (kg) (V) (hr)※ 1
(A) (W) (Im) (Im/W) (K)
KLS-701-8M
KLS-701 series require a pole separately for installation. (Adaptable pole diameter:ø76.3mm)
unit : cd/1000 lm
Outside length of
insulated wire:
: A‒A (0˚‒180˚)
150mm
: B‒B (90˚‒270˚)
unit
Mounting Height :5m
Maintenance Factor:0.63
■ Basic Performance
Input Power Luminous Luminous Color
Model Standard Weight Voltage Lamp Life
Lamp Housing Cover Current Consumption Flux Efficiency Temperature
Name Color (kg) (V) (hr)※ 1
(A) (W) (Im) (Im/W) (K)
220 AC 0.365
240 AC 0.345
SAL-800
Solar light (street light) is a system
that converts sunlight into electricity
and to use as a street light.
KAGA's solar light is compact and
simple, and designed to be used with
our LED street light products.
■ Light Distribution
SAL-800
unit : cd/1000 lm
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚)
■ Dimensions
1218
(4061)
(3910)
G.L
■ Specifications ■ Features
No CO2 Emissions No Commercial Power Required
Model Name SAL-800
Since the high-efficiency solar panel directly LED solar light eliminates the need for power
converts sunlight into electric energy, CO2 is distribution work and makes the installation
Lamp LED 1W type×8 not be emitted. easy. It can be also installed even in the
places with no electric power supply, such as
riverside areas and beaches.
Solar Panel 50W×1 Reduction in Maintenance Costs
Long-life LEDs are adopted for the light
Creating a Safe Environment with
Backup Power source of Kaga Solar Lights. The cost for
for Rainy and 7 days
replacing light source can be reduced. Disaster-prevention Design
Cloudy Days
LED solar light creates a safe environment
by lighting up dangerous areas such as
100% for 7 hours after sunset,
Lighting Time
30% for hours until sunrise
Creating Corporate Image as an pitch-dark parks and school zone at night.
Environment Responsive Company Moreover, when the power is out in case
Turn-on automatically after
Lighting sunset LED solar light contributes to company's of disasters, or solar batteries cannot be
System Turn-off automatically at image with eco-friendly practices as well as charged due to bad weather, it can light up
sunrise
economic effects. for 7 nights.
10
LED Street Lights for Solar Lights (12V DC Type)
SLE-129-12L LEDEEMA for solar lights is specifically designed to be used with solar applications.
■ Light Distribution
SLE-129-12L
90 90
100
200
60 300 60
400
500 30
30
600
A unit : cd/1000 lm
: A‒A (0˚‒180˚)
B
A : B‒B (90˚‒270˚)
■ Dimensions
151 337
126
100
SLE-128-17R LEDEEMA for solar lights is specifically designed to be used with solar applications.
■ Light Distribution
SLE-128-17R
unit : cd/1000 lm
: A‒A (0˚‒180˚)
: B‒B (90˚‒270˚)
■ Dimensions
221 376
140
100
■ Basic Performance
Input Power Luminous Luminous Color
Model Standard Weight Voltage Lamp Life
Lamp Housing Cover Color Current Consumption Flux Efficiency Temperature
Name (kg) (V) (hr)※1
(A) (W) (Im) (Im/W) (K)
KLE-137-52L 52 5,720
Die cast aluminum housing 15※1
220/240
KLE-137-81 For mounting on φ34.0 / 81 50-60 9,100 70 5※3
AC
φ48.6 / φ60.5mm arm pipe
KLE-137-92 92 9,800 20※2
KLE-128-19
4 10.0 11.7 W480 x L540 x H340
KLE-128-26R
11.6 13.8
KLE-137-52L
KLE-137-81 2 12.0 14.2 W363 x L631 x H432
KLE-137-92
12.2 14.4
SAL-800 ー ー ー ー
12
Safety Precautions for Photo Controls
Read installation instructions before installing luminaire. Failure to comply may result in serious injury or death.
! WARNING
● Do not disassemble or modify photo control. It may cause fire or electric shock.
● Do not damage the insulator for power cable when wiring.
! CAUTION
● Do not install in the shaded side of tress, buildings, etc.
● Do not install in a dark place in the daytime or in a place getting artificial lights.
Maintenance
● Photo control malfunctions if it turns on in the daytime. Replace photo control.
● Cleanthe cover about once a year.
● When the photo control is tilted or upside-down, there is a risk of insulation deterioration by ingress of water, and replace photo control.
● When replacing photo control, check the current and voltage of the load, and replace appropriate photo control.
! WARNING
● Do not remodel the luminaire and only use genuine specified parts when maintaining luminaire.
● Do not install luminaire if there is any sign of damage, such as cracks to the cover or housing.
! CAUTION
● Do not connect power if there is a sign of water within the luminaire.
● Disconnect power immediately if there is smoke or fire. Contact supplier.
13
http://www.kaga-bouhantou.jp/en/
Head Office
139 Akiba-cho, Totsuka-ku, Yokohama, Kanagawa 245-0052, Japan
Phone:81(45)-811-1921 FAX:81
(45)-811-7159