[poe. No.

: CON-F-71 I
<t.> Valve Chamber Construction Report LRev. No. : 00 I
GUJARATGAS
_lEft. Date: 12.02.2018 I
Project: SHUKALTIRTHDPRC EXT PROJECT Report No. : 01
Location: NI!ar Maharshi Bunglows, Shukaltirth Road Date: 24-04-2018
Size: 8" X 6.4mm API 51Gr X52
Chamber Number: BMSO 029 /
1890 X 1500 X SITE
1 Sizeof Valve Chamber (L X B X H) 1890 X 1500 X 1900
CONDITION (

2 irype of cement used GR ope 53 GR OPCS3

3 Proportion of cement, sand and aggregates 1:1.5:3


(' 1:1.5:3

4 Thickness of raft / bottom slab PCC75MM PCC75MM

5 !Thickness of walls 150MM 150MM


(

6 Reinforcement Details

A RAFT

Oia & spacing of main bar (bottom) «: 010 MM 150(C 010 MM 150(C

Dia & spacing of distribution bar (bottom) 012 MM 150CC 012 MM 150(C

Oia & spacing of main bar (Top) 010 MM 150(( 010 MM 150(C

Oia & spacing of distribution bar (Top) 012 MM 150(C 012 MM 150CC

B BEAM & COLUMNS

Dia & spacing of main bar (outer face) 010 MM 150(( 010 MM 1S0C(

Dia & spacing of distribution bar (outer face) 08 MM 150(( 08 MM 150(C

Oia & spacing of main bar (inner face) 010 MM 150C( 010 MM 150C(

Oia & spacing of distribution bar (inner face) 08 MM 150(( ¢8 MM 150(C

c WALLS

Dia & spacing of main bar (outer face) ¢8MM 150(( ¢8 MM 150((

Oia & spacing of distribution bar (outer face) ¢8 MM 150(( ¢8MM 150(C

Dia & spacing of main bar (inner face) ¢8 MM 150CC ¢8 MM 150C(

Oia & spacing of distribution bar (inner face) 08MM 150(( ¢8MM 150CC

7 ANTI CORROSSIVE PAINT ON RE-BARs(YES/ NO) NA NA

R 95 paint for buried Part & apply paint on non buried part of valve
8 YES YES
assembly (YES/ NO)

9 LADDER(YES/ NO) NA NA

10 ENGRAVING ON VALVE CHAMBER COVERS(YES/ NO) YES YES

Ensure Painting of Valve Chamber Numbers with Flow Direction Arrow


11 YES YES
Inside chamber On sleeper & On near by structure)

12 SUMP (YES/ NO) YES YES

13 WATERPROOFING PROVIDED (YES/ NO) NA NA

14 CONCRETECUBE TEST RESULTATTHE AGE OF 7 DAYS NA NA

1S CONCRETECUBE TEST RESULTAT THE AGE OF 28 DAYS NA NA

CONTRACTOR TPIA ~ GGL


\ ~~ ,aO"Al(~

IT
'"
Sign -A..\»~~~C p~.
~ _-\-j).M~V.-\ ~~ ~~ ~~
Name
~V; W~rr4r9c. l~~\
en,
:..,,;.' ...'lo. ~r\ J\.~{ ~

Date
9--ll(\ v ~~~?/ ~v
V.~"-V-,-
"-~(!
l. \./
t'V"
Doc.No. : CON-F-71 J
(fa> Valve Chamber Construction Report Rev. No. : 00 J
GUJARA.'TCAS 1E1f. Date:12.02.2018 J
Project: SHUKALTIRTHDPRCEXT PROJECT Report No. : 02
Location: Near Maharshi Bunglows, Shukaltirth Road Date: 24-04-2018
Size: 4" X 6.4mm API 51 Gr X52
Chamber Number: BMSD 030
Specification as per
Sr. No. Description Actual Construction Remarks
Drawing
1760 X 1500 X SITE
1 Size of Valve Chamber (L X B X H) 1800 X 1500 X 1900
CONDITION

2 GR OPC53 GR OPC 53

3 Proportion of cement, sand and aggregates 1:1.5:3 1: 1.5:3 .

4 Thickness of raft / bottom slab PCC75MM PCC75MM

5 Thickness of walls 150MM 150MM

6 Reinforcement Details

A RAFT

Dia & spacing of main bar (bottom) 010 MM 150(( 010 MM 150CC

Dia & spacing of distribution bar (bottom) 012 MM 150C( 012 MM 150CC

Dia & spacing of main bar (Top) 010 MM 150(( 010 MM 150CC

Dia & spacing of distribution bar (Top, 012 MM 150(( 012 MM 150CC

B BEAM & (OLUMNS

Dia & spacing of main bar (outer face' 010 MM 150(( 010 MM 150(C

Dia & spacing of distribution bar (outer face) 08 MM 150(( 08 MM 150(C

Dia & spacing of main bar (inner face' 010 MM 150C( 010 MM 150CC

Dia & spacing of distribution bar (inner face) 08 MM 150(( 08 MM 150C(

( WALLS

Dia & spacing of main bar (outer face' 08 MM 150(( 08 MM 150C(

Dia & spacing of distribution bar (outer face) 08 MM 150(( 08 MM 150C(

Dia & spacing of main bar (inner face' 08 MM 150(( 08 MM 15OC(

Dia & spacing of distribution bar (inner face) 08 MM 150(( 08 MM 15OC(

7 ANTI CORROSSIVEPAINT ON RE-8ARS(YESI NO) NA NA

R 95 paint for buried Part & apply paint on non buried part of valve
8 YES YES
assembly_(YES_LNO)

9 LADDER(YESI NO) NA NA

10 ENGRAVINGON VALVE CHAMBERCOIIERS(YESI NO) YES YES

Ensure Painting of Valve Chamber Numberswith Flow Direction Arrow


11 YES YES
Inside chamber On sleeper & On near bv structure)

12 SUMP (YESI NO) YES YES

13 WATERPROOFINGPROVIDED (YES/NO) NA NA

14 (ONCRETE CUBETESTRESULTAT THEAGEOF 7 DAYS NA NA

15 CONCRETECUBETESTRESULTAT THEAGEOF28 DAYS NA NA