Professional Documents
Culture Documents
Pinch TEQIP16
Pinch TEQIP16
Rangan Banerjee
Department of Energy Science and Engineering
IIT Bombay
Lecture in KIC-TEQIP programme on Energy Management and Energy Efficiency - IITG - 24th May 2016
Heat Exchanger Network Synthesis
(Pinch Analysis)
Steam 1200C
200C 800C
2kW/0C
Heating
Steam 1200C
200C 800C
2kW/0C
Source: Linnhoff
2
Heat Exchanger Network Synthesis
(Pinch Analysis)
300C
1500C
900C
2kW/0C
500C
300C Cooling
1500C
900C
2kW/0C
500C
Source: Linnhoff
3
Alternative Network
1500C 900C
120kW
800C
200C
1500C 900C
120kW
800C 200C
Source: Linnhoff
4
Area and Energy
Q UAT
Integration
As T decreases, expect Area to increase
But if Q decreases, Area may also decrease
120 = (UA) 70
UA = 1.7 kW/k
Total UA = 3.4 kW/k
In earlier case total UA = 6.44 kW/k
Hence cost energy 5
Problem Definition
Q CPdT CP (TT TS ) H
Ts
6
Problem Definition
Stream No. Type CP (kW/0C) Ts 0C Tt 0C
1 C 2.0 20 135
2 H 3.0 170 60
3 C 4.0 80 140
Source: Linhoff
7
Parallel grid representation
CP (kW/0C)
1700C 600 3.0
H 2
300
1500C 1.5
H 4
1400C 800
4.0
C 3
8
Data Specification
Set of hot streams to be cooled and set of cold
streams to be heated
Inlet and outlet temperatures (Tin, Tout) of steams
Additional constraints
Plant layout, safety, flexibility, controllability,
operability.
9
Temperature – Enthalpy diagram
T
Tt dH
CP
dt
dT 1
Slope =
0C dH CP
If Ts > Tt Hot stream
Ts < Tt Cold stream
Ts
H = CP(Tt-Ts)
kW
H
10
Cold Streams
11
Cold Composite Curve
12
Hot Streams
13
Hot Composite Curves
14
Pinch Analysis
180
160
140
Temperature (oC)
120
HCC
100
80
CCC
60
40
20
0
Enthalpy (H)
15
Pinch Analysis
180
QH=20 kW
160
140
Temperature (oC)
120
100
80
∆T=10oC
60
40
20
QC=60 kW
0
Enthalpy (H)
16
Design rules
17
Pinch
QH,min
C
T
H Pinch
H
18
19
HEAT CASCADE From Hot Utility From Hot Utility
1650C 0 kW 20 kW
1 H=-60kW
80 kW
1450C 60 kW
2 H=-2.5kW
1400C 62.5 kW 82.5 kW
3 H=+82.5kW
850C
-20 kW 0 kW
4 H=-75kW
550C 55 kW 75 kW
5 H=+15kW
250C 40 kW 60 kW
1400 800
3 4.0 QC MIN =60 kW
QH MIN = 20 kW
PINCH
21
DESIGN
1700 900 600
2 I III
1500 300
900 700
4 II IV C
60kW
1350 1250 800 350 200
H 1
20kW 90kW 30kW
90kW
1400 800
3
240kW
22
Eulers Theorem
23
Targeting no of units
24
Energy Relaxation
25
2 I III
1500 T2 300
4 II C
60+X
1350 650 200
H 1
20+X 120-X 90
3
PATH
240
26
1700 900 600
2 I III
1400 800
3
240 u = uMIN = 5
27
28
29
30
31
References
1. B. Linhoff, User Guide on Process Integration for the
Efficient Use of Energy IChem E (1984), London.
2. U. V. Shenoy, Heat Exchanger Network Synthesis, Gulf
Publishing Company, Houston, Texas, 1995.
32