Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

A.6 .

Applicable Loading as per UG - 22


Sub
Clause Description
( 1 ) Internal Design Pressure as defined in UG-21 Applicable
(a)
( 2 ) External Design Pressure as defined in UG-21 Applicable

Weight of the vessel and normal contents under


(b) operating or test conditions ( including aditional pressure Applicable
due to static head of liquid) ;

Superimposed Static Reactions from weight of attached


(c) equipment, such as motors, machinery, other vessels, Not Applicable
piping, linings and insulation.
( 1 ) Attachment of internals Applicable (Note:1)
(d) ( 2 ) Vessel supports such as lugs, rings, skirts, saddles
Applicable
and legs.

Cyclic and dynamic reactions due to pressure or thermal


(e) variations, or from equipment mounted on a vessel, and Applicable
mechanical loadings.
Wind Reaction (Note: 2) Not Applicable
(f) Seismic Reaction ( Note:3) Not Applicable
Snow Reaction Not Applicable
(g) Impact reactions such as those due to fluid shock Not Applicable

(h) Temperature Gradient and differential thermal expansion Not Applicable

Abnormal Pressures, Such as Those Caused by


(i) Not Applicable
Deflagration

Test Pressure and Coincident static head acting during


(j) Applicable
test( UG-99)

Note:
1) Internal nozzle pipe, dish and internal tubing is attached to the vessel hencs additional 75
kg load is considered in design and No additional loads transferred to pressure parts over and
above design loads specified.