LOCATION : LOT 6, BLOCK 10, NATIONAL HIGHWAY BRGY.ZONE 15, TALISAY CITY,
NEGROS OCCIDENTAL
GENERAL CONDITIONS
1.1 General
1.1.1 All works incorporated herein or as shown on plans and detailed drawings shall be done
in accordance with the National Building Code of the Philippines in conformity of the
Building Ordinance.
1. All materials and workmanship shall conform to the latest building code of American
concrete institute (ACI-318).
2. All concrete shall develop a minimum comprehensive strength at the end of (28) Days will
corresponding maximum size aggregate and slumps as follow:
COLUMN
PEDISTALS 3000 PSI (210KG/ cm2) ¾ IN. (19MM) 4 IN. (100M)
3. All reinforcing bar shall conform to ASTM A615 (PNS49) grade 40 for diameter 12 and
smaller bars and grade 40 for diameter 16 and larger bars column and hoops are all grade 40
bars.