SSDAC Question Paper

1. Axle counters & track circuits are treated as authorized ____


a) Means of communication
b) Means of knowledge
c) Means of transportation
d) None
2. What are the frequencies used in HASSDSC of GG Tronics make?
a. 15 KHz & 17 KHz
b. 21 KHz & 25 KHz
c. 21 Hz & 25 Hz
d. 23 KHz & 25 KHz
3. What is the resistance of vital relay of digital axle counter?
a. 1000 Ohms
b. 9 Ohms
c. 50 Ohms
d. 100 Ohms
4. TX coil is always connected _________ the rail.
a. Outside
b. Inside
c. Both sides
d. Between
5. The distance from home signal to the block section shall not be less than _______ Mtrs.
a. 180
b. 120
c. 400
d. 580
6. What is the maximum current drain by DC –DC converter of GG Tronics make?
a. 300 mA
b. 1200 mA
c. 200 mA
d. 500 mA
7. SSDAC communication using V.23 FSK modem with cable loss of _______________ dB.
a. 20
b. 30
c. 40
d. 50
8. Basic principle employees n SSDAC is ________________
a. Amplitude detection
b. Frequency detection
c. Phase detection
d. Voltage detection
9. The minimum train wheel diameter, Which the system senses____________
a. 500mm
b. 490mm
c. 520mm
d. 550mm
10. The design of track device is suitable for _____________rails.
a. 50Kg & 62Kg
b. 42Kg & 64Kg
c. 52Kg & 60Kg
d. 50Kg & 60Kg
11. The indoor equipment consists of ______________
a. Evaluator System
b. SM Reset box
c. Relay Rack
d. All of the above
12. The input voltage of DC – DC converter is ______________
a. 24V
b. 12V
c. 18V
d. 5V
13. In system evaluator MS Coupler no. 5 is used for ____________cable.
a. PD card
b. Relay card
c. SMC PU card
d. Communication card
14. The SF & EF units communicate with each other in FSK mode at _____________ baud rate.
a. 1000 BPS
b. 1400 BPS
c. 1200 BPS
d. 1600 BPS
15. The TX & RX signals will be in phase under _________condition.
a. No Wheel / Axle
b. Wheel / Axle
c. Both a & b
d. None of the above
16. The SSDAC system is suitable for axle detection for train speed up to _______KMPH
a. 150
b. 200
c. 250
d. 300
17. The loop resistance of Quad cable is ___________
a. 58 ohms/Km
b. 50 ohms/Km
c. 56 ohms/Km
d. 52 ohms/Km
18. The minimum voltage required for reset box is ___________
a. 24 V
b. 12 V
c. 18 V
d. 48 V
19. ________ are used for avoiding damage to the detector coils.
a. Reflectors
b. Deflectors
c. Sensors
d. All of the above
20. The temperature, at which the system can work _________
a. +10°C to + 70°C
b. - 20°C to + 80°C
c. - 10°C to + 70°C
d. - 10°C to + 60°C
21. The input voltage to the PD card from DC – DC converter is ___________
a. 24V
b. -12V
c. 12V
d. 18V
22. The insulation resistance of Quad cable between conductors is more than ______ohms
a. 10m
b. 10M
c. 10K
d. 10
23. While trouble shooting, which error code displays for SM CPU missing?
a. 3
b. 7
c. 6
d. 5
24. SSDAC system unit is housed near the track with its DP placed at a variable distance of _____
a. 10 Mtrs
b. 25 Mtrs
c. 15 Mtrs
d. 30 Mtrs
25. The SM Event Logger logs up to ___________ no of events.
a. 11000
b. 12000
c. 16000
d. 14000
26. The maximum RX signal induced voltage in an Axle counter is _____
a. 900mV to 1.2V AC
b. 900mV to 1.2 V DC
c. 300mV to 900mV AC
d. 300mV to 900mV DC
27. The main purpose of two different frequencies provided in TX coils of Axle detectors is ____
a. To detect coil functioning
b. To detect wheel direction
c. To detect regular time period
d. To count the no. of axles
28. Which type of MS Coupler no. is used for Reset in system evaluator ?
a. 6
b. 8
c. 10
d. 11
29. In Trouble shooting , How many possible errors occurs in our system ?
a. 61
b. 65
c. 62
d. 60
30. The Input voltage to drive relays in RD is ____
a. 48
b. 12
c. 24
d. 18
31. The architecture suited for proving station sections & block sections is_____
a. 1 out of 2
b. 2 out of 2
c. 2 out of 3
d. 1 out of 3
32. Which configuration of GGTronics SSDAC G-36 is used for point zone ?
a. 2 DP - 1S
b. 3 DP -1S
c. 3 DP - 2S
d. All of the above
33. In HASSDAC-G36R , How many SF’s & EF’s are housed in location boxes ?
a. 1 SF & 2 EF
b. 2 SF & 1 EF
c. 2 SF & 2 EF
d. 1 SF & 1 EF
34. The average drain current in SSDAC & HASSDAC is____
a. > 1.5 Amp
b. < 1 Amp
c. < 1.5 Amp
d. > 1 Amp
35. How many Kms long , the system monitors the block station ?
a. 40 Km
b. 30 Km
c. 50 Km
d. 25 Km
36. The SSDAC system works in _____areas.
a. RE Area
b. Non RE Area
c. Both a & b
d. None of the above
37. The communication between the units of SSDAC system over medium is____
a. ½ quad cable
b. 1 quad cable
c. 2 quad cable
d. 4 quad cable
38. Which of the card houses the system software of GGTronics SSDAC G-36 which schedules
the overall operation as per configuration?
a. Phase Detector Card (PD 1 & PD2)
b. Communication Card (Com1 & Com2)
c. Relay Drive Card (RD1 & RD2)
d. CPU Card (CPU1 & CPU2)
39. The Reset box gives information of _______
a. Each PD status
b. Section error message
c. Each DP wheel counts
d. All of the above
40. In SSDAC system , which card is used to perform wheel counting ?
a. PD1 & PD2
b. SM Event logger
c. DC –DC Power supply card
d. CPU _1/2
41. The SSDAC system detects _____
a. Train wheels
b. Solid trolley wheels
c. Push trolley wheels
d. All of the above
42. The SSDAC system makes counting of ____
a. Train wheels
b. Solid trolley wheels
c. Push trolley wheels
d. All of the above
43. The Relay drive output to the Vital relay measured across R1 & R2 in GGTronics SSDAC G36 with section
unoccupied shall be
a. >28 V DC
b. >26V DC
c. >24 V DC
d. >20 V DC
44. Earthing resistance of system should be______
a. < 5 Ohms
b. < 2 Ohms
c. > 5 Ohms
d. > 2 Ohms
45. The relay box for each DP in a 2DP-1S version of GGTronics SSDAC G-36 consists of
a. 1 Vital Relay & 1 Preparatory Relay
b. 2 Vital Relays & 2 Preparatory Relays
c. 1 Vital Relay only
d. 1 preparatory relay only
46. 2DP-1S and 3DP-2S versions of GGTronics SSDAC G-36 together can be is used for
a. Single station/block for entry/exit
b. Point zone
c. Auto Signalling application
d. None of the above
47. The relay box for each DP in a 3DP-1S version of GGTronics SSDAC G-36 consists of
a. 1 Vital Relay & 1 Preparatory Relay
b. 2 Vital Relays & 2 Preparatory Relays
c. 1 Vital Relay only
d. 1 Preparatory Relay only
48. The relay box of Centre Fed (CF) unit in a 3DP-2S version of GGTronics SSDAC G-36
consists of
a. 1 Vital Relay & 1 Preparatory Relay
b. 2 Vital Relays & 2 Preparatory Relays
c. 1 Vital Relay only
d. 1 Preparatory Relay only
49. Which of the following is NOT indicated on LCD display of reset box of GGTronics SSDAC G36 ?
a. DP status
b. Wheel counts
c. Reset counts
d. Error condition
50. Earthing resistance of system should be______
a. < 5 Ohms
b. < 2 Ohms
c. > 5 Ohms
d. > 2 Ohms
51. RX coil is always connected _________ the rail.
a. Outside
b. Inside
c. Both sides
d. Between
52.

You might also like