POWER kVA 27 30
POWER kW 27 30
HIMOINSA HEADQUARTERS:
Fábrica: Ctra. Murcia - San Javier, Km. 23,6 | 30730 SAN JAVIER (Murcia) Spain Himoinsa has the right to modify any feature without prior notice.
Tel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34 968 19 04 20 |
info@himoinsa.com | www.himoinsa.com Weights and dimensions based on standard products. Illustrations may
include optional equipment.
Manufacture facilities:
SPAIN • FRANCE • INDIA • CHINA • USA • BRAZIL • ARGENTINA Technical data described in this catalogue correspond to the available
Subsidiaries: information at the moment of printing.
PORTUGAL | POLAND | GERMANY | UK | SINGAPORE | UAE | PANAMA |
DOMINICAN REPUBLIC | ARGENTINA | ANGOLA | SOUTH AFRICA The illustrations and images are indicative and may not coincide in their
entirety with the product.
Industrial design under patent.
2019-DIC.-10 19:50
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HHW-35 M6
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HHW-35 M6
APPLICATION DATA
EXHAUST SYSTEM NECESSARY AMOUNT OF AIR
Maximum exhaust temperature ºC 550 Alternator fan air flow m³/s 0,242
Soundproofed version
• External emergency stop switch • Reinforced lifting hooks for crane hoisting • IP Protection according to ISO
8528-13:2016
• Bodywork made from high quality steel • Watertight chassis (acts as a double barrier
• 3 way valve for external fuel supply (available in
plate against liquid retention) 1/2" and 3/8" fittings) (Opcional).
• High mechanical strength • Fuel tank drain plug • Fuel transfer pump (Opcional).
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HHW-35 M6
FEATURES OF THE
CONTROL UNITS
M7X CEA 7 CEC 7 M7X+CEC7
Voltage between phases • • • •
Voltage between neutral and phase • • • •
Current intensities • • • •
Generator Readings
Frequency • • • •
Apparent power (Kva) • • • •
Active power (Kw) • • • •
Reactive power (kVAr) • • • •
Power factor • • • •
Voltage between phases • • •
Voltage between phases and neutral • • •
Current intensities • • •
Frequency • • •
Mains Readings
Apparent power •
Active power •
Reactive power •
Power factor •
Coolant temperature • • •
Oil pressure • • •
Engine Readings
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HHW-35 M6
Short-circuit • • •
Asymmetry between phases • • • •
Incorrect phase sequence • • • •
Inverse power • • •
Overload • • •
Genset signal drop • • • •
Total hour counter • • • •
Partial hour counter • • • •
Kilowatt meter • • • •
Starts valid counters • • • •
Counters
GSM/GPRS modem ⓪ ⓪ ⓪
Remote screen ⓪
Tele signal ⓪ (8 + 4)
J1939 ⓪ M7XJ ⓪ ⓪ M7XJ
Programmable outputs • • •
Multilingual • • •
GPS Positioning ⓪
Synchronisation ⓪
Mains synchronization
Special Functions
⓪
Second Zero elimination ⓪
RAM7 ⓪
Remote screen ⓪
Programming timer ⓪
2019-DIC.-10 19:50
• Standard Optional
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HHW-35 M6
CONTROL
PANELS
AS7 AS5
Automatic control AS5 with CEA7 unit.
panel WITHOUT Automatic control
Transfer Switch and panel without
WITHOUT mains transfer switch and
control with M7X WITH mains control.
unit.
Digital control unit
Digital control unit CEA7
M7X
CC2 AS7 +
CC2
Himoinsa Switching
cabinet WITH display. Automatic control
Digital control unit panel WITH transfer
CEC7 switch and WITH
mains control. The
display will be on the
genset and on the
cabinet.
Digital control unit
M7X+CEC7
AC5
Automatic mains
failure control panel.
Wall-mounted
cabinet WITH
transfer switch and
thermal magnetic
protection
(depending on
current and voltage).
Digital control unit
CEA7
Electrical system
• Electric control and power panel • Battery charger (standard on • Starter battery/ies installed
with measurements devices gensets with automatic control (cables and bracket included)
and control unit (according to panels)
necessity and configuration) • Ground connection electrical
• Heating resistor (standard on installation with connection
• Electrical control panel with sets with automatic control ready for ground spike (not
earth leakage protection panels) supplied)
• 2-pole thermal magnetic circuit • Battery charger alternator with • Battery Switch (Opcional).
breaker ground connection
2019-DIC.-10 19:50
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com