Download as pdf
Download as pdf
You are on page 1of 5
PVSYST V6.81 21/10/19 Page 1/5 Grid-Connected System: Simulation parameters Project : Prince Pipes Salempur Mahdad Geographical Site Situation Latitude Time defined as Legal Time Albedo Meteo data: Salempur Mahdad Country India 29.94" N Longitude 78.05° E Time zone UT+5.5 Attitude 289m 0.20 Meteonorm 7.2 (1981-2010), Sat=100% - Synthetic Simulation variant: Simulation-2 Simulation date 21/10/19 1746 Simulation parameters System type 4 orientations titsfazimuths No 3D scene defined, no shadings 10°1-45", 10°84", 10749", 107-135" Models used Transposition Perez Diftuse Perez, Meteonorm Horizon Free Horizon Near Shadings No Shadings User's needs : Unlimited load (grid) PV Arrays Characteristics (4 kinds of array defined) PV module Sipoly Model Eldora VSP.72.330.05_U Original PVsyst database Manufacturer Vikram Solar Sub-array "Sub-array #1" Orientation #1 TivAzimuth 10°45 Number of PV modules Inseries 18 modules in parallel 109 strings Total number of PV modules Nb. modules 1962 Unit Nom. Power 330 Wp Array global power Nominal (STC) 647kWp _Atoperating cond, 587 kWp (50°C) Array operating characteristics (50°C) Umpp 614V Impp 956 A Sub-array "Sub-array #2" Ofientation #2 Tivazimuth —10"/-144 Number of PV modules Inseries 18 modules In parallel 60 strings Total number of PV modules Nb, modules 1080 Unit Nom. Power 330 Wp Array global power Nominal (STC) 356 kWp- At operating cond. 323 kWp (50°C) ‘Array operating characteristics (50°C) Umpp 614V Impp 526A Sub-array "Sub-array #3" Orientation #3 TivAzimuth 40°/49" Number of PV modules In series 18 modules In parallel 25 strings Total number of PV modules Nb. modules 450 Unit Nom. Power 330 Wp Array global power Nominal (STC) 149kWp At operating cond. 135 kWp (50°C) Array operating characteristics (50°C) Umpp 614V Impp 219 ‘Sub-array "Sub-array #4" Orientation #4 TilvAzimuth —10°/-136" Number of PV modules Inseries 18 modules In parallel 10 strings Total number of PV modules Nb. modules 180 Unit Nom. Power 330 Wp Array global power Nominal (STC) 59.4 KWp Atoperating cond, 63.8 kWp (50°C) Array operating characteristics (50°C) Umpp 614V Impp 88A Total Arrays global power Nominal (STC) 1242 kWp Total 3672 modules Module area 7114 m* Inverter Model SG6OKTL Original PVsyst database Manufacturer Sungrow Characteristics Operating Voltage 570-950 Unit Nom. Power 60.0 kWac Sub-array "Sub-array #1" Nb. of inverters. 9 units Total Power 540 kWac Pom ratio 1.20 Sub-array "Sub-array #2" Nb. ofinverters 5 units Total Power 300 kWac Pom ratio 1.19 PVSYST V6.81 21/1019] Page 2/5 Grid-Connected System: Simulation parameters Sub-array "Sub-array #3" Nb. of inverters 2 units Total Power 120 kWac Pnom ratio 1.24 Sub-array "Sub-array #4” Nb. ofinverters 1 units Total Power 60 kWac Pnom ratio 0.99 Total Nb. of inverters 17 Total Power 1020 kWac PV Array loss factors Array Soiling Losses Loss Fraction 3.0% Thermal Loss factor Wiring Ohmic Loss Uc (const) 15.0 Wimek Array#t1 141 mOhm Array#2_-20 mOhm Array#3 47 mOhm Array#l4 117 mOhm Uv (wind) Loss Fraction Loss Fraction Loss Fraction Loss Fraction 0.0 Wim? / mis 1.8 % at STC 1.5 % at STC 1.5 % at STC 1.8 % at STC Global Loss Fraction 1.5% at STC Module Quality Loss Loss Fraction -0.8 % Module Mismatch Losses Loss Fraction 1.0 % at MPP Strings Mismatch loss Loss Fraction 0.10 % Incidence effect (IAM): Fresnel smooth glass, n= 1.526 ° 30° 50° 60" 70° 75° 80° 3° 90° x000_| 0.998 | a9i_| 0.048 | 0.862 | 0.776 | 0.636 | 0.403] 0.000 System loss factors Wires: 3x1200.0 mm? 157m Loss Fraction 1.8 % at STC Unavailabilty of the system 7.3 days, 3 periods Time fraction 2.0 % PVSYST V6.8 2110/19] Page 3/5 Grid-Connected System: Main results Project : Prince Pipes Simulation variant: _Simulation-2 Main system parameters System type No 3D scene defined, no shadings PV Field Orientation A orientations TilvAzimuth = 10°/-48", 10°/-144", 10°/49", 10°/-136" PV modules. Model Eldora VSP.72.330.05U nom 330 Wp PV Aray Nb. of modules 3672 Prom total 1212 kWp Inverter Model SGEOKTL Pnom 60.0 kW ac Inverter pack Nb. of units 17.0 Prom total 1020 kW ac User's needs Unlimited load (grid) Main simulation results System Production Produced Energy Performance Ratio PR 1771 MWhlyear 76.28 % Specific prod. 1462 kWh/kWplyear Normalized productions (per Installed KY): Nominal power 1212 kWp a (u. E WR a Perera 8 Simulation-2 Balances and main results GtobHor | DiftHor | T_Amb | Globinc ] Giobéff ] EArray | EGrid | PR vewiyme | tewhyme | ec | kwiyme | tetye | wh | Mw January uss | 3083 | wse | u76 | 178 | 204 | 1180 | os February 1303 | 3772 | 1597 | 1331 | 1236 | 1342 | i315 | osis March 123 | 4927 | 2135 | issa | 1721 | 1785 | i747 | 0.783 April 2030 | 644s | 2701 | 2033 | 1908 | 1993 | 1952 | 0752 May z34 | seiz | 3057 | 227 | 1994 | 1984 | 1904 | 0739 June 120 | 9797 | 3020 | isia | 1693 | 1695 | asia | 0.689 uly 1sa7 | 9203 | 2938 | 1536 | 1a1 | 1467 | 1438 | 0773 August 1592 | 8998 | 2846 | 1590 | 1482 | 1526 | 1495 | 0.776 lseptember | 1539 | 7144 | 2680 | 1553 | 1447 | 1493 | 146.2 | 0.777 Joctober 105 | aio | 2388 | 1637 | 1526 | ise4 | issa | over November x96 | 2496 | 1820 | 1339 | 1229 | 1327 | 167 | ons December us2_|_ 2196 | 1408 | 1193 | 1088 | 1205 | 1095 | 0.757 Year 1979 | 71052 | 2324 | 19166 | 17034 | 18466 | i775 | 0.763 Legends: GlobHor Horizontal global irradiation Globe Effective Global, corr. for TAM and shadings DiffHor Horizontal diffuse radiation Enrray Effective energy at the output ofthe array TLAmb Ambient Temperature E.crid Energy injected into arid GlobInc Global incdent in col plane PR Performance Ratio PVSYST V6.81 2410/19| Page 4s Grid-Connected System: Special graphs Project : Prince Pipes Simulation variant: Simulation-2 Main system parameters PV Field Orientation PV modules. PV Array Inverter Inverter pack User's needs System type No 3D scene defined, no shadings orientations TilAzimuth = 10°/-45°, 10°/-144°, 10°/49°, 10°7-135" Model Eldora VSP.72.330.05_U Nb. of modules 3672 Prom total Model SG6OKTL Nb. of units 17.0 Pnom total Unlimited load (grid) Pnom 330 Wp 1212 kWp Pnom 60.0 kW ac 1020 kW ac 7000 Daily Input/Output diagram 6000 5000 + 4000 fo ont phy 3000 2000 1000 T T T T T Values from 01/01 to 31/12 L L L L L La, 2 3 4 5 6 Global incident in coll plane [kWhimn? day] System Output Power Distribution 60000 0000} 40000 30000}- 20000 ney 10000 }- T T Values from 01/01 to 31/12 200 400 600 Power injected into grid KW] 800 PVSYST V6.81 21/1019] Page 515 Grid-Connected System: Loss diagram Project : Prince Pipes Simulation variant: Simulation-2 Main system parameters System type No 3D scene defined, no shadings PV Field Orientation A orientations TilvAzimuth = 10°/-48", 10°/-144", 10°/49", 10°/-136" PV modules: Model Eldora VSP.72.330.05 U Pnom 330 Wp PV Array Nb. of modules 3672 Pnom total 1212 kWp Inverter Model SGEOKTL Pnom 60.0 kW ac Inverter pack Nb. of units 17.0 Phom total 1020 kW ac User's needs Unlimited load (grid) Loss diagram over the whole year 1898 Kin Horizontal global inaction +1.0% Global incident in col plane 0.04% Globalinidert below tweshold 47% AM facta on global 3.00% Soling oss factor 789 kw 7114 mca Eftectivelradaton on collectors efcionsy @ STC= 17.06% PV conerion 25 Mh Array nominal energy (at STC effi) Ki.050% pViess du toiradiance level 12.69% PV Ios dv to temperature 40.75% Module alt bss 130% Mismatch ss, meddes and sings 101% Ohmic wing loss 126 wn Array val energy at MPP 1.18% Inverter Loss during operation (efficiency) 200% Invert Loss over nominal nv power 200% Inverter Loss due to mak input curent 200% Inverter Loss over nonal iv volage 2.0% Inverter Los de to power teshotd 0.50% Inverter Loes due to voliagetreshold 1825 Mm ‘Avallable Energy at Inverter Output 2.05% ‘System unavailability 088% AC ohmic ss srt Mn Energy injected ino grid

You might also like