Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings. Daikin Air Conditioner Made in Japan
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Split Type Air Conditioners
Cautions on product corrosion DC Inverter Power Control Heat Pump [50/60 Hz]
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Specifications, designs and other content appearing in this brochure are current as of February 2014 but subject to change without notice. c All rights reserved
PCRMT1407aprv
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings. Daikin Air Conditioner Made in Japan
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Split Type Air Conditioners
Cautions on product corrosion DC Inverter Power Control Heat Pump [50/60 Hz]
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Specifications, designs and other content appearing in this brochure are current as of February 2014 but subject to change without notice. c All rights reserved
A New Level of Comfort
Urusara 7 offers a unique, total comfort experience for
any lifestyle. Powerful year-round cooling and
dehumidifying is just the beginning.
Notes: 1. Urusara 7 received a prestigious Red Dot Award: Product Design 2013 from the Design Zentrum
Nordrhein Westfalen in Germany.
2. For residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched
Urusara 7 in the Japanese market.
3. In January 2013, the 4.0 to 7.1 kW class models for the Japanese market received the Minister’s
Prize from Japan’s Ministry of Economy, Trade and Industry in the Fiscal 2012 Grand Prizes for
Excellence in Energy Efficiency and Conservation.
1 2
Seven Benefits of Urusara 7 Benefit 2 Benefit 3
Energy Savings
・Double Air Intake
・High-Density Heat Exchanger
・Sharp-Edged Cross Flow Fan
Benefit 7
Automatic Filter
Contents Cleaning
A New Level of Comfort Page 1 ・Cleaning Filter Operation
Benefit 5 Benefit 4
Designed in Japan Airflow Control
・Innovative Design ・Circulation Airflow
・Coanda Mechanism
・Double Air Intake
3 4
Lineup
FTXZ25/35/50NVM RXZ25/35/50NVM
2.5 kW Class
FTXZ25NVM / RXZ25NVM
2.45 (0.6-3.9) kW
Cooling Capacity
Rated (Min.-Max.)
8,400 (2,000-13,300) Btu/h
3.6 (0.6-7.5) kW
Heating Capacity
Rated (Min.-Max.)
12,300 (2,000-25,600) Btu/h
3.5 kW Class
FTXZ35NVM / RXZ35NVM
3.45 (0.6-5.3) kW
Cooling Capacity
Rated (Min.-Max.)
11,800 (2,000-18,100) Btu/h
5.0 (0.6-9.0) kW
Heating Capacity
Rated (Min.-Max.)
17,100 (2,000-30,700) Btu/h
5.0 kW Class
FTXZ50NVM / RXZ50NVM
4.95 (0.6-5.8) kW
Cooling Capacity
Rated (Min.-Max.)
16,900 (2,000-19,800) Btu/h
6.3 (0.6-9.4) kW
Heating Capacity
Rated (Min.-Max.)
21,500 (2,000-32,100) Btu/h
Category: Product Design 2013
5 6
Benefit 1 Energy Savings
A New Era for Energy Efficiency
2012 Grand Prize for Excellence in Energy Efficiency Inverter Advantages Compared to Non-Inverter
and Conservation Inverters are devices which are able to vary their operating capacity by adjusting frequency. Inverter air
conditioners can vary their capacity by adjusting the power supply frequency of their compressors. In
Daikin has always pushed to achieve higher levels of energy efficiency. After reviewing Urusara’s
contrast, non-inverter air conditioners have a fixed capacity and can only control the indoor temperature
performance, Daikin engineers decided to use next-generation R-32 refrigerant due to its superior
by starting or stopping their compressors. Inverter air conditioners are more powerful, energy-efficient
energy efficiency. They also developed a new indoor heat exchanger, double air
and comfortable than non-inverter models.
intake and revised DC Inverter Power Control.
Thanks to these efforts, Urusara 7 delivers greater energy efficiency. In January
2013, Urusara 7’s 4.0 to 7.1 kW class models for the Japanese market received the Comfortable Temperature Control
Minister’s Prize from Japan’s Ministry of Economy, Trade and Industry in the Fiscal
2012 Grand Prizes for Excellence in Energy Efficiency and Conservation. Temp.
Product: Urusara 7 (S40PTRXP, S56PTRXP, S63PTRXP, S71PTRXP), Minister’s Prize, Ministry of Economy, Trade and
Industry, Fiscal 2012 Grand Prize for Excellence in Energy Efficiency and Conservation (Product Category and Business
Inverter type
Model Category), Sponsor: Energy Conservation Center, Japan
Not cool
S40PTRXP,S56PTRXP,
S63PTRXP,S71PTRXP
Comfortable
Too cool
Set temp. Non-inverter type
First 7-Star Rating for Australia Start
Time
Urusara 7 achieves high COPs of 4.30 to 5.70 during cooling operation thanks to Daikin’s combined
energy-saving technologies and DC Inverter Power Control. The 2.5 kW model for the Australian
market is the first split-type air conditioner to receive the country’s top 7-Star Super Efficiency rating.
Electricity Consumption after One Year of Operation 1
No other air conditioner has obtained this rating as of February 2014. The models for Europe have also
received top ratings.
The Urusara 7 models listed below have received Singapore’s 4 Tick Energy Label, which is the country’s
highest energy-efficiency rating for inverter type air conditioners.
58% energy saving
Australia's 7-Star Efficiency rating Singapore’s 4 Tick rating Europe’s A rating
1,132 kWh
A +++
475 kWh
RXZ25N RXZ35N RXZ50N
Non-inverter type Inverter type
Compared to non-inverter models, Urusara 7 cuts power consumption
by up to 58%. This helps to reduce electricity bills for the user and
An air conditioner’s COP (Coefficient of also decreases CO2 emissions caused by power generation.
What Is COP? Performance) indicates how efficiently the Capacity (W)
COP =
unit uses energy. A higher COP means greater energy efficiency. It Power consumption (W)
also means lower electricity consumption, so you save money.
Note: 1. Test method: In-house simulation based on the principles of JIS-C9612B.1.6.5 for inverter models and JIS-C9612B.1.6.4 for non-inverter models
Test inverter model: 3.5 kW class model of Urusara 7 for the Thailand market, rated COP 5.00, COP in the partial load region 6.39
Test non-inverter model: 3.5 kW class Daikin non-inverter model for the Thailand market, COP 3.45
Test location: Bedroom of 24 m2
Test conditions: Annual average outdoor temperature in Bangkok
Test period: 9 hours of operation from 10:00 p.m. to 7:00 a.m.
7 8
Benefit 1 Energy Savings
Swing Compressor
Conventional Daikin inverter models Urusara 7
Thanks to its smooth rotation, the swing
compressor decreases friction and
vibration. It also prevents the leakage
of refrigerant gas during compression.
These advantages provide quiet and
efficient compression.
Fan Fan
Heat Heat Interleaved PAM Control
exchanger exchanger
PAM (pulse amplitude modulation)
control reduces energy loss by
specifying how often the converter
The back part of the heat exchanger is only Air intake from both the top and bottom allows the switches on and off. Urusara 7 is
partially used. back part of the heat exchanger to be used fully, equipped with twin interleaved PAM
resulting in higher energy efficiency. circuits. This ensures efficiency for
both high and low output.
Magnetic power
Dimple
Rapid switching
Embedding a high-strength neodymium magnet in the rotating shaft turns the entire
centre of the motor into a powerful magnet. By rapidly switching the electromagnet
from the N to S-pole, the Reluctance DC motor is able to produce greater speed and
power. Urusara 7 uses a new dysprosium-reduced neodymium magnet.
9 10
Benefit 1 Energy Savings
Normal operation
310 W
Econo Mode
Power consumption
When there is no movement, Intelligent It automatically stops operation after one
Eye automatically adjusts the set or three hours.
temperature by 2˚C.
Time
11 12
Benefit 2 Next-Generation Refrigerant
ozone layer and to restrict the production, consumption and trade of relevant substances. Based on the 4,750
adoption of this protocol, industrialised countries are required to eliminate alternative fluorocarbons 1,810 2,090
including R-22 (HCFC) by 2020, 1 675
1987 1997 Around 2000
while developing countries are CO2 R-32 R-22 R-410A R-11 R-12 R-23
obliged to gradually reduce their CFC refrigerant R-12 HCFC refrigerant R-22 HFC refrigerant R-410A
Ozone depletion 1.0 0.05 0
use from 2013, and to eliminate potential value
them by 2030. In industrialised countries, the changeover from R-22 (HCFC) to R-410A (HFC) is well underway.
Through replacement with R-410A, ozone depletion potential has been reduced to zero. However,
R-410A still has a high global warming potential. Energy Efficiency
Air conditioners are major consumers of electricity but about half of the energy 3 they use is still
Schedule of Reduction for HCFC Consumption Volumes generated by fossil fuel power plants. The CO2 discharged in this process is a known greenhouse gas.
Industrialised countries
Air conditioning manufacturers must be responsible for providing energy efficient equipment.
Developing countries
(%) Daikin has redesigned its residential-use air conditioners to use R-32. This enables its systems to
100% 100%
100 achieve new levels of energy efficiency while reducing environmental impact.
90%
80
65% 65%
60
Refrigerant is changed from gas to
Refrigerant liquid in the outdoor unit, after which
40 32.5%
25% it is evaporated in the indoor unit. During cooling operation,
cool air is discharged from the indoor unit while heat is
20
10% removed from the air taken in from inside the room. This heat
0.5% 0.5% 2.5%
0 is delivered to the outdoor unit and released.
1996 2000 2004 2010 2013 2015 2020 2025 2030 2040 (year)
13 14
Benefit 3 Humidity Control
Room air
Indoor temperature ˚C
20
Selecting this function starts dehumidifying operation during cooling operation. It dehumidifies
30 40 50 60 70 80 by cooling at a low airflow rate, resulting in a lower room temperature.
Humidity %
15 16
Benefit 4 Airflow Control
Airflow discharged
from the unit
It takes a long time to achieve a similar temperature in all Circulation Airflow rapidly achieves a uniform temperature in
corners of the room. each corner of the room.
Breeze Airflow
Natural pattern of a gentle breeze
Urusara 7 recreates the natural pattern of a gentle breeze,
providing a cool airflow without direct draft. Based on (2) Rapidly switching wave
Speed of airflow
precisely fluctuating waves1. Daikin has recreated this (3) Precisely
variable rhythm using its advanced airflow control fluctuating wave
3-D Airflow
Vertical Auto-Swing automatically moves the flaps up and down and Horizontal Auto-Swing automatically
moves the louvers to the left and right. 3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate
air to every part of a room for uniform cooling/heating of even large spaces.
4 2
Inspired by Japanese “Ogi”
3 In 2013, Urusara 7 received a prestigious Red Dot Award:
Product Design 2013 from the Design Zentrum Nordrhein
Westfalen in Essen, Germany. The internationally recognised
Red Dot has been awarded to products of outstanding quality
The flaps and louvers swing in turn, expanding the comfort zone.
since 1954.
Urusara 7 was praised for its innovative design, inspired by the Japanese “ogi” folding
fan. This is exemplified by the Coanda flap mechanism, which modifies the airflow to create
Installation Position Setting a pleasant indoor environment. Daikin’s use of R-32 refrigerant and other advanced
A pattern for the room shape and installation position can be selected with the wireless remote control- technologies also reduces energy consumption and environ-
ler. This enables control of the horizontal airflow direction to be optimised. mental impact.
Daikin believes with Urusara 7 it has created a leading air
conditioner integrating a new shape and cutting-edge technolo-
gies developed in Japan.
Note: 1. Based on a report issued by the Prefectural University of Kumamoto on August 31, 2012.
Test model: 4.0 kW class Daikin inverter model for the Japanese market
Test conditions: In an environment with a temperature of 27°C and relative humidity of 50%, subjects evaluated their comfort levels while seated at rest in a chair
2 m in front of the air conditioner and 850 mm above the floor. Valid responses were gathered from 16 Japanese male and female subjects in their twenties. The
evaluations of comfort/discomfort levels and airflow patterns were made over an extended period.
19 20
Benefit 6 Air Purification
Photocatalytic Air-Purifying
and Deodorising Filter
Streamer Technology
Streamer discharge decomposes bacteria and mould adsorbed on the filter by irradiating
them with an advanced plasma electric discharge. It provides highly effective oxidative
decomposition. Streamer discharge is one of the methods of plasma electric discharge. The streamer discharge generates The high-speed electrons hit and combine This generates high-strength
high-speed electrons. with nitrogen and oxygen in the air. decomposition elements.
With the same electrical power, the oxidative decomposition speed is over 1,000 times
faster than ordinary plasma electric discharge (glow discharge).
To achieve this performance, Daikin developed original Step 2 Decomposes Allergic Substances
technologies which successfully stabilise the flow of electrons.
Oxygen radical
Area of electron
discharge OH radical
Excited nitrogen
Primary decomposition Excited oxygen Secondary decomposition
(decomposes surface) (decomposes centre)
21 22
Benefit 5 Air Purification
23 24
Benefit 7 Automatic Filter Cleaning
Auto SL L M H
You no longer have to clean the prefilter. After operation stops, this function automatically brushes dust Each decrease in airflow volume reduces the
Sound pressure level
sound pressure level.
off the prefilter and collects it in the installed dust box. Cleaning automatically starts after 18 hours or
more of cumulative operation. The cleaning lasts
a maximum of 11 minutes and once the Mould- Electricity Consumption after One Year of Operation
Proof/Cleaning Filter lamp starts blinking, you only Without Cleaning
125%
Filter Operation
need to discard the dust collected in the box. This Outdoor Unit Quiet Operation
With Cleaning
helps to maintain filter performance and prevent Filter Operation 100%
energy loss. This function decreases the sound pressure level from the rated operation (H). It can be started easily
This function prevents reduced operational performance caused
by dust collecting on the prefilter. It decreases annual electricity from the wireless remote controller. (Capacity may decrease during Outdoor Unit Quiet Operation.)
consumption by 25%1.
19 20 30 40 43 50
(dB (A))
The prefilter is automatically moved The brush removes dust attached to The removed dust is collected in the Rustling of leaves Library
downwards. the prefilter. dust box.
Pendulum of a wall clock Normal office
65
Body temperature fluctuation pattern V-shaped pattern programme 40
Constant temperature V-shaped pattern
Body temperature Set temperature control programme
Low
Core body temperature
Time 9:00 6:00 Sleep 0:00 3:00 6:00 Wakeup Sleep time 0 1 2 3 4 5 6 Constant temperature control V-shaped pattern programme
a.m. p.m. a.m. a.m. a.m.
Accelerates onset of deep sleep 120
Body temperatures drop slowly as people begin to sleep and rise
as their wakeup time approaches. The room temperature drops slowly as you begin to sleep, lowering your
body temperature while you are asleep.
100
You awake feeling refreshed
The room temperature rises as your wakeup time approaches, causing your
body temperature to rise just before you awake.
80
Required deep sleep
3 hours difference
Both the operation start and stop time can be preset. With this timer, the air conditioner starts and stops 40
at the same time every day. Using the Daily On Timer ensures your living room and bedroom are cool
Total time spent in deep sleep (min.)
Time (min.)
0 60 120 180 240 300 360 420
Countdown Off Timer
The operation stop time can be set with the touch of a single button and preset for a period of 0.5 to 9.5 V-shaped pattern programme Constant temp. control
hours in 30 minute increments. Set 4 and the unit will stop after four hours. This is convenient if you want
90 minutes of 90 minutes of
to maintain cooling or dry operation during the night even if you do not use the Daily Off Timer. deep sleep deep sleep
3 hours of sleep 6 hours of sleep
Daily On/Off Timer Starts and/or stops daily operation at the same time. To experience satisfying sleep, you need 90 minutes of deep sleep. Three hours of sleep is necessary
with the V-shaped pattern programme and six with the constant temperature control.
Notes: 1. Japanese Society of Sleep Research, “Comfort Sleep Experiment Research 2002”
2. This result was obtained through research. There are wide differences between individuals.
27 28
Controller
Off switch
29 30
Functions
Comfortable Airflow Lifestyle Convenience Comfort Control Cleanliness
3-Area Intelligent Eye (Focus) Auto Off Operation Sarara Dry Operation Streamer Discharge Air Purifying
Intelligent Eye has infrared sensors which detect human movement Auto Off Operation uses 3-Area Intelligent Eye to This dehumidifying function stabilises the room temperature The streamer discharge decomposes bacteria and mould
in left, right and centre zones. Intelligent Eye Focus automatically automatically stop operation if no movement is detected in a and prevents overcooling, even for people who are particularly adsorbed by the indoor unit’s photocatalytic filter. After the
adjusts horizontal airflow to send air directly to a person. room. A detection period of one or three hours can be set. sensitive to cold. particles are trapped, they are irradiated by the streamer device.
See page 11 See page 12 See page 16 See pages 21 to 23
3-Area Intelligent Eye (Comfort) Standby Electricity Saving Dry Cooling Operation Mould-Proof Operation
Intelligent Eye has infrared sensors which detect human movement Even when an air conditioner is not operating, it requires This combined dehumidifying and cooling operation The streamer discharge dries the inside of the indoor unit,
in left, right and centre zones. Intelligent Eye Comfort automatically standby power. However, thanks to this function, the required dehumidifies by cooling at a low airflow rate, resulting in a heat exchanger and airflow routes. It effectively prevents the
adjusts horizontal airflow to avoid blowing air onto a person. standby power can be reduced. lower room temperature. growth of both mould and odour-causing bacteria.
See page 11 See page 11 See page 16 See page 24
Cleaning Filter Operation
Circulation Airflow Econo Mode Indoor Unit Quiet Operation
After operation stops, this function automatically brushes
This function uses the Coanda effect to rapidly achieve the set This mode limits maximum running current and power Indoor unit operating sound pressure levels are decreased by dust off the prefilter and collects it in a box. This helps to
temperature. The double air intakes and cross flow fan consumption. This improves operating efficiency and also 7 to 10 dB (A) from the Low setting fan speed using the maintain filter performance and energy efficiency.
increase airflow to circulate air around a room. prevents circuit breakers from being overloaded. wireless remote controller. See page 25
See page 11 See page 26
See page 17
Outdoor Unit Quiet Operation Photocatalytic Air-Purifying and
Breeze Airflow Inverter Powerful Operation Deodorising Filter
This function recreates the natural rhythm of a gentle breeze. This function is convenient for boosting cooling/heating Outdoor unit operating sound pressure levels are decreased from
the rated operation sound using the wireless remote controller. While the filter’s micron-level fibres are able to effectively
With this airflow pattern, even people who are sensitive to performance for a 20 minute period both when the air trap dust, its photocatalyst has the ability to adsorb odours.
conditioner is first turned on or it is necessary to change the See page 26
drafts feel comfortable when air is directed towards them. See page 23
See page 19 room temperature quickly.
Automatic Operation Wipe-Clean Flat Panel
Power-Airflow Flap This function automatically selects cooling or heating The flat panel design can be cleaned with only the single
The Power-Airflow Flap can flatten out during cooling operation mode based on the room temperature at start-up. pass of a cloth across its smooth surface. The flat panel can
operation to deliver cool air to the corners of a room. The also be easily removed for more thorough cleaning.
flap can direct warm air straight down to the floor during
heating operation. Auto Fan Speed
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature. Worry Free
Wide-Angle Louvers
The smoothly curved Wide-Angle Louvers provide wide Child-Proof Lock
airflow coverage for effective operation no matter where the Information Display Hot-Start Function
indoor unit is placed in a room. The LCD provides various details on current operation, After defrosting or when starting heating operation, air is pre- This function allows users to lock operation using the
including temperature and humidity. It also displays heated before discharge to prevent uncomfortable cold drafts. wireless remote controller. It is useful for preventing setting
information such as total energy use over several days. changes if children play with the controller.
See page 29
Auto-Restart after Power Failure
Wireless Remote Controller with Backlight Timers The air conditioner memorises the settings for mode, airflow,
The large LCD and backlit buttons allow easy operation in the temperature, etc., and automatically returns to them when
From a corner Covers even dark. Frequently used functions are conveniently located on power is restored after a power failure.
to the centre a spacious room the front of the controller. Comfort Sleep Timer
See page 29 This function controls the indoor temperature using a Self-Diagnosis with Digital Display
V-shaped pattern based on sleep science, helping to promote Malfunction codes are shown on the digital display panel of
Installation Position Setting Indoor Unit Lamp Brightness Setting restful sleep. It is only necessary to set a wakeup time. the wireless remote controller for fast and easy maintenance.
The room shape and installation position can be set on the The indoor unit is equipped with an operation lamp, timer See page 27
wireless remote controller. This enables optimal control of lamp and various other indicators. The brightness of these Anticorrosion Treatment of Outdoor
the horizontal airflow direction. lamps can be adjusted to High, Low or Off. Daily On/Off Timer Heat Exchanger Fins
See page 19 This timer allows users to set the operation start and stop times
so the air conditioner turns on and off at the same time every day. The outdoor unit’s heat exchanger fins are processed using a
special anticorrosion treatment. The surface is covered with
Vertical Auto-Swing (up and down) See page 27
a thin acrylic resin layer to enhance the fins’ resistance to
This function automatically moves the flaps up and down to acid rain and salt corrosion.
distribute air across a room. Countdown Off Timer Cross section of anticorrosion-treated fin
The operation stop time can be preset for a period of 0.5 to Hydrophilic film
9.5 hours in 30 minute increments. Aluminium
Horizontal Auto-Swing (left and right) See page 27 Corrosion-resistant
acrylic resin
Horizontal Auto-Swing automatically moves the louvers to the
left and right to cover a room with cool/warm air. Indoor Unit On/Off Switch 24-Hour On/Off Timer
The unit can be conveniently started manually in the event the This timer can start or stop the air conditioner within a 24-hour
wireless remote controller is misplaced or the wireless remote period. It can be preset in 10-minute steps by pressing the
3-D Airflow controller batteries are not charged. On/Off timer button on the wireless remote controller. The On
Heat exchanger fin
This function combines Vertical and Horizontal Auto-Swing to timer and Off timer can be used in combination.
circulate a cloud of cool/warm air right to the corners of even
large spaces. The flaps and louvers swing in turn. Quick Heating Timer
See page 19 Heating operation can be preset to turn on one minute after Automatic Defrosting
the set wakeup time. Warm airflow starts just one minute later. Before starting heating operation, a sensor checks for frost in
the outdoor unit and performs automatic defrosting if
necessary so that only warm air is discharged.
31 32
Specifications Options
Indoor Unit
Indoor unit FTXZ25NVM FTXZ35NVM FTXZ50NVM No. Item FTXZ25/35/50N
Model name
Outdoor unit RXZ25NVM RXZ35NVM RXZ50NVM 1 5-room centralised controller *1 KRC72A
kW 2.45 (0.6-3.9) 3.45 (0.6-5.3) 4.95 (0.6-5.8) Wiring adaptor for time clock/remote controller *2
Cooling Rated 2 KRP413AB1S
(Min.-Max.) Btu/h 8,400 (2,000-13,300) 11,800 (2,000-18,100) 16,900 (2,000-19,800) (Normal open pulse contact/normal open contact)
Capacity
Rated kW 3.6 (0.6-7.5) 5.0 (0.6-9.0) 6.3 (0.6-9.4) 3 Photocatalytic air-purifying and deodorising filter set *3 KAF046A41
Heating
(Min.-Max.) Btu/h 12,300 (2,000-25,600) 17,100 (2,000-30,700) 21,500 (2,000-32,100) 4 Remote controller loss prevention with chain KKF936A4
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. The time clock and other devices should be obtained locally.
Running current Cooling 2.1-2.0-2.0/2.1-2.0 3.2-3.0-2.9/3.2-3.0 5.3-5.1-4.8/5.3-5.1 *3. The filter is a standard accessory.
(220-230-240 V, 50 Hz/ Rated A
220-230 V, 60 Hz) Heating 2.9-2.8-2.7/2.9-2.8 4.6-4.4-4.3/4.6-4.4 6.5-6.2-6.0/6.5-6.2
Cooling Rated 430 (110-880) 680 (110-1,330) 1,150 (110-1,600)
Power consumption W
Heating (Min.-Max.) 620 (100-2,010) 1,000 (100-2,530) 1,410 (100-2,640)
Cooling Rated 5.70 (5.45-4.43) 5.07 (5.45-3.98) 4.30 (5.45-3.63)
COP W/W
Heating (Min.-Max.) 5.81 (6.00-3.73) 5.00 (6.00-3.56) 4.47 (6.00-3.56)
5-room centralised controller Photocatalytic air-purifying and Remote controller loss
Indoor unit FTXZ25NVM FTXZ35NVM FTXZ50NVM KRC72A deodorising filter prevention with chain
Front panel colour White KAF046A41 KKF936A4
Cooling m3/min 10.7 (379) 12.1 (428) 15.0 (545)
Airflow rate (H)
Heating (cfm) 11.7 (415) 13.3 (469) 14.4 (517) Outdoor Unit
Fan speed 5 steps, quiet and automatic No. Item RXZ25/35/50N
Sound pressure levels Cooling 38/26/19 42/27/19 47/30/23 1 Air direction adjustment grille KPW937D4
dB (A)
(H/L/SL) Heating 39/28/19 42/29/19 44/31/24 Drain plug *1
2 KKP937A4
Dimensions (H x W x D) mm 295 x 798 x 370 Note: *1. One set includes 5 pieces for 5 units.
Machine weight kg 15
Outdoor unit RXZ25NVM RXZ35NVM RXZ50NVM
Casing colour Ivory white
Compressor type Hermetically sealed swing type
Air direction adjustment grille Drain plug
Refrigerant charge (R-32) kg 1.34 KPW937D4 KKP937A4
Sound pressure levels Cooling dB (A)
46 48 49
(H) Heating 46 48 50 Control System
Dimensions (H x W x D) mm 595 x 795 x 300
No. Item FTXZ25/35/50N
Machine weight kg 43 *1
1 Central remote controller DCS302CA61
Cooling CDB –10 to 43 *1
Operation range 2 Unified On/Off controller DCS301BA61
Heating CWB –20 to 18
3 Schedule timer *1 DST301BA61
Liquid 6.4
4 Interface adaptor for DIII-NET use KRP928BB2S
Piping Gas 9.5
mm Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
connection Indoor unit: I.D. 16.0, O.D. 18.0
Drain
Outdoor unit: I.D. 15.9
Max. piping length 30
m
Max. height difference 12
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. Central remote controller Unified On/Off controller Schedule timer
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound pressure levels are based on the temperature conditions 1 and 2 above. These are anechoic conversion values. These values are normally somewhat higher during DCS302CA61 DCS301BA61 DST301BA61
actual operation as a result of ambient conditions.