Specification

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

PCRMT1407aprv

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings. Daikin Air Conditioner Made in Japan
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Split Type Air Conditioners
Cautions on product corrosion DC Inverter Power Control Heat Pump [50/60 Hz]
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Specifications, designs and other content appearing in this brochure are current as of February 2014 but subject to change without notice. c All rights reserved
PCRMT1407aprv
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings. Daikin Air Conditioner Made in Japan
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Split Type Air Conditioners
Cautions on product corrosion DC Inverter Power Control Heat Pump [50/60 Hz]
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Specifications, designs and other content appearing in this brochure are current as of February 2014 but subject to change without notice. c All rights reserved
A New Level of Comfort
Urusara 7 offers a unique, total comfort experience for
any lifestyle. Powerful year-round cooling and
dehumidifying is just the beginning.

Urusara 7 puts the latest advances in Japanese


air-conditioning technology at your fingertips. Features
like the new circulation airflow wrap you in a cloud of
effortless comfort while advanced streamer technology
effectively purifies air. This design excellence extends
to the sleek, award-winning indoor unit1.

Urusara 7 is also the world’s first air conditioner to use


next-generation R-32 refrigerant2. Along with its many
energy-saving features, this higher performance
refrigerant gives Urusara 7 unrivaled energy efficiency3.

Daikin Air Conditioner Made in Japan

Notes: 1. Urusara 7 received a prestigious Red Dot Award: Product Design 2013 from the Design Zentrum
Nordrhein Westfalen in Germany.
2. For residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched
Urusara 7 in the Japanese market.
3. In January 2013, the 4.0 to 7.1 kW class models for the Japanese market received the Minister’s
Prize from Japan’s Ministry of Economy, Trade and Industry in the Fiscal 2012 Grand Prizes for
Excellence in Energy Efficiency and Conservation.

1 2
Seven Benefits of Urusara 7 Benefit 2 Benefit 3

Next-Generation Humidity Control


・World's First Use of Humidity Control
Refrigerant
Benefit 1
・World's First Use of R-32

Energy Savings
・Double Air Intake
・High-Density Heat Exchanger
・Sharp-Edged Cross Flow Fan

Benefit 7

Automatic Filter
Contents Cleaning
A New Level of Comfort Page 1 ・Cleaning Filter Operation

Seven Benefits of Urusara 7 Page 3


Lineup Page 5

Energy Savings Page 7


Next-Generation Refrigerant Page 13

Humidity Control Page 15


Airflow Control Page 17
Designed in Japan Page 20
Air Purification Page 21

Automatic Filter Cleaning Page 25


Quiet Operation and Timers Page 26 Benefit 6
Controller Page 29
Functions Page 31 Air Purification
Specifications and Options Page 33 ・Streamer Technology

Benefit 5 Benefit 4
Designed in Japan Airflow Control
・Innovative Design ・Circulation Airflow
・Coanda Mechanism
・Double Air Intake

3 4
Lineup
FTXZ25/35/50NVM RXZ25/35/50NVM
2.5 kW Class
FTXZ25NVM / RXZ25NVM
2.45 (0.6-3.9) kW
Cooling Capacity
Rated (Min.-Max.)
8,400 (2,000-13,300) Btu/h
3.6 (0.6-7.5) kW
Heating Capacity
Rated (Min.-Max.)
12,300 (2,000-25,600) Btu/h
3.5 kW Class
FTXZ35NVM / RXZ35NVM
3.45 (0.6-5.3) kW
Cooling Capacity
Rated (Min.-Max.)
11,800 (2,000-18,100) Btu/h
5.0 (0.6-9.0) kW
Heating Capacity
Rated (Min.-Max.)
17,100 (2,000-30,700) Btu/h
5.0 kW Class
FTXZ50NVM / RXZ50NVM
4.95 (0.6-5.8) kW
Cooling Capacity
Rated (Min.-Max.)
16,900 (2,000-19,800) Btu/h
6.3 (0.6-9.4) kW
Heating Capacity
Rated (Min.-Max.)
21,500 (2,000-32,100) Btu/h
Category: Product Design 2013
5 6
Benefit 1 Energy Savings
A New Era for Energy Efficiency
2012 Grand Prize for Excellence in Energy Efficiency Inverter Advantages Compared to Non-Inverter
and Conservation Inverters are devices which are able to vary their operating capacity by adjusting frequency. Inverter air
conditioners can vary their capacity by adjusting the power supply frequency of their compressors. In
Daikin has always pushed to achieve higher levels of energy efficiency. After reviewing Urusara’s
contrast, non-inverter air conditioners have a fixed capacity and can only control the indoor temperature
performance, Daikin engineers decided to use next-generation R-32 refrigerant due to its superior
by starting or stopping their compressors. Inverter air conditioners are more powerful, energy-efficient
energy efficiency. They also developed a new indoor heat exchanger, double air
and comfortable than non-inverter models.
intake and revised DC Inverter Power Control.
Thanks to these efforts, Urusara 7 delivers greater energy efficiency. In January
2013, Urusara 7’s 4.0 to 7.1 kW class models for the Japanese market received the Comfortable Temperature Control
Minister’s Prize from Japan’s Ministry of Economy, Trade and Industry in the Fiscal
2012 Grand Prizes for Excellence in Energy Efficiency and Conservation. Temp.
Product: Urusara 7 (S40PTRXP, S56PTRXP, S63PTRXP, S71PTRXP), Minister’s Prize, Ministry of Economy, Trade and
Industry, Fiscal 2012 Grand Prize for Excellence in Energy Efficiency and Conservation (Product Category and Business
Inverter type
Model Category), Sponsor: Energy Conservation Center, Japan
Not cool
S40PTRXP,S56PTRXP,
S63PTRXP,S71PTRXP
Comfortable
Too cool
Set temp. Non-inverter type
First 7-Star Rating for Australia Start
Time
Urusara 7 achieves high COPs of 4.30 to 5.70 during cooling operation thanks to Daikin’s combined
energy-saving technologies and DC Inverter Power Control. The 2.5 kW model for the Australian
market is the first split-type air conditioner to receive the country’s top 7-Star Super Efficiency rating.
Electricity Consumption after One Year of Operation 1
No other air conditioner has obtained this rating as of February 2014. The models for Europe have also
received top ratings.
The Urusara 7 models listed below have received Singapore’s 4 Tick Energy Label, which is the country’s
highest energy-efficiency rating for inverter type air conditioners.
58% energy saving
Australia's 7-Star Efficiency rating Singapore’s 4 Tick rating Europe’s A rating
1,132 kWh
A +++
475 kWh
RXZ25N RXZ35N RXZ50N
Non-inverter type Inverter type
Compared to non-inverter models, Urusara 7 cuts power consumption
by up to 58%. This helps to reduce electricity bills for the user and
An air conditioner’s COP (Coefficient of also decreases CO2 emissions caused by power generation.
What Is COP? Performance) indicates how efficiently the Capacity (W)
COP =
unit uses energy. A higher COP means greater energy efficiency. It Power consumption (W)
also means lower electricity consumption, so you save money.
Note: 1. Test method: In-house simulation based on the principles of JIS-C9612B.1.6.5 for inverter models and JIS-C9612B.1.6.4 for non-inverter models
Test inverter model: 3.5 kW class model of Urusara 7 for the Thailand market, rated COP 5.00, COP in the partial load region 6.39
Test non-inverter model: 3.5 kW class Daikin non-inverter model for the Thailand market, COP 3.45
Test location: Bedroom of 24 m2
Test conditions: Annual average outdoor temperature in Bangkok
Test period: 9 hours of operation from 10:00 p.m. to 7:00 a.m.
7 8
Benefit 1 Energy Savings

Advanced Daikin Technologies Made in Japan


DC Inverter Power Control
DC Inverter is Daikin’s term for an inverter air conditioner
Double Air Intake equipped with a DC motor. These motors use the power of
magnets to generate rotation, making
The indoor unit features air intakes on both the top them more efficient than AC motors.
Advanced DC motors for compressors
and bottom. The double intakes maintain a large
and fan motors equipped with
airflow volume by drawing in additional air from the high-power neodymium magnets are
bottom intake. Urusara 7 improves the operational capable of even greater efficiency.
efficiency of the indoor heat exchanger by also utilis- These motors are called Reluctance
DC motors.
ing the back of the device.

Swing Compressor
Conventional Daikin inverter models Urusara 7
Thanks to its smooth rotation, the swing
compressor decreases friction and
vibration. It also prevents the leakage
of refrigerant gas during compression.
These advantages provide quiet and
efficient compression.
Fan Fan
Heat Heat Interleaved PAM Control
exchanger exchanger
PAM (pulse amplitude modulation)
control reduces energy loss by
specifying how often the converter
The back part of the heat exchanger is only Air intake from both the top and bottom allows the switches on and off. Urusara 7 is
partially used. back part of the heat exchanger to be used fully, equipped with twin interleaved PAM
resulting in higher energy efficiency. circuits. This ensures efficiency for
both high and low output.

Sharp-Edged Cross Flow Fan Reluctance DC Motor for Compressors


High-Density Heat Exchanger The new indoor cross flow fan features sharp-edged The compressor is one of an air conditioner’s core components
and its performance is directly linked to the motor. Daikin was
An improved indoor heat exchanger design significantly increases cooling/heating dimples and impellers. This innovative shape
the first to successfully use the Reluctance DC motor with a
performance. The new structure uses thin copper piping densely packed in five layers, increases airflow volume as well as scroll compressor in commercial-use air conditioners1. This
allowing it to exchange heat more effectively. energy efficiency. motor has now been installed in the swing compressors used
for residential-use air conditioners.
Three-dimensional groove
Reluctance DC motor Dysprosium-reduced neodymium magnet

Magnetic power
Dimple
Rapid switching

Electromagnet Repelling power

Embedding a high-strength neodymium magnet in the rotating shaft turns the entire
centre of the motor into a powerful magnet. By rapidly switching the electromagnet
from the N to S-pole, the Reluctance DC motor is able to produce greater speed and
power. Urusara 7 uses a new dysprosium-reduced neodymium magnet.

Note: 1. Daikin’s achievement was recognised by the Institute of Electrical Engineers of


Japan at the 54th Academic Promotion and Technical Development Awards in 1998.

9 10
Benefit 1 Energy Savings

A Variety of Energy-Saving Functions


Econo Mode
This function limits the maximum power consumption to 310 W during cooling operation and 470 W Auto Off Operation
during heating operation for the 2.5 kW model. It is particularly effective if the cooling load is high, for 3-Area Intelligent Eye can be set to automatically stop operation after one or three hours if there is no
example, at startup or during large gatherings and periods of direct sunshine. (Maximum capacity movement in a room. With Auto Off Operation, you never have to worry about forgetting to turn off the
decreases during Econo Mode, requiring more time to reach the set temperature.) air conditioner again.

Normal operation

310 W
Econo Mode

Power consumption
When there is no movement, Intelligent It automatically stops operation after one
Eye automatically adjusts the set or three hours.
temperature by 2˚C.
Time

3-Area Intelligent Eye (Focus)


Intelligent Eye sensors detect an area
where there is a person and adjust the
horizontal airflow to send air directly
Standby Electricity Saving to the person.
Even when the air conditioner is not operating, it requires standby power. However, thanks to the
Standby Electricity Saving function, the required standby power can be reduced.

3-Area Intelligent Eye


3-Area Intelligent Eye (Comfort)
3-Area Intelligent Eye prevents energy wastage by using its infrared sensors to detect human move-
Intelligent Eye sensors detect an area
ment in a room. It has two infrared sensors and detects the location of a person in an area divided into
where there is a person and adjust the
left, right and centre zones.
horizontal airflow to avoid blowing air
When there is no movement, Intelligent Eye automati-
directly onto the person.
cally adjusts the set temperature by 2˚C to achieve energy
savings. It can also be set to automatically stop operation. Left Right
Airflow can either be directed toward or away from people
to increase comfort. Centre

11 12
Benefit 2 Next-Generation Refrigerant

R-32 Refrigerant: A Better Choice for Climate Change


One Million Units in Cumulative Sales Lower Global Warming Potential
Daikin is the sole manufacturer to produce both air conditioning The Kyoto Protocol was adopted in 1997 to reduce greenhouse gases
1,000,000 Units equipment and refrigerants around the world. As a refrigerant which cause climate change. Greenhouse gases include carbon dioxide
manufacturer, Daikin believes it has a responsibility to expand the (CO2), hydrofluorocarbons (HFCs), hydrochlorofluorocarbons (HCFCs),
in Cumulative Sales
use of substances with zero ozone-layer depletion and to reduce chlorofluorocarbons (CFCs) and various other substances.
For R-32 residential-use split-type air
conditioners in the Japanese market greenhouse gas emissions. To reduce greenhouse gases, manufacturers of air conditioning
As an equipment manufacturer, Daikin believes it must work to equipment are urgently required to find refrigerants with a lower global Greenhouse gases trap heat (infrared
reduce these greenhouse emissions throughout the entire product lifecycle. By combining R-32 refrigerant warming potential than R-410A (HFC). At the same time, they must also wavelengths) in sunlight which enters the
Earth’s atmosphere from space. This thermal
and Urusara 7’s operational efficiency, Daikin has taken the next step in reducing environmental impact. reduce energy consumption, enabling CO2 emissions to be decreased. energy warms the atmosphere.
Daikin has adopted R-32 for all models of its residential-use wall-mounted split-type air condition-
ers in the Japanese market. These systems achieved one million units in cumulative sales as of Novem-
ber 20131. 100 Year Global Warming Potential of Different Refrigerants2

No Impact on Ozone-Layer Depletion Approx. 30%


14,800
The Montreal Protocol was adopted in 1987 to specify substances which are potentially harmful to the 10,900

ozone layer and to restrict the production, consumption and trade of relevant substances. Based on the 4,750
adoption of this protocol, industrialised countries are required to eliminate alternative fluorocarbons 1,810 2,090
including R-22 (HCFC) by 2020, 1 675
1987 1997 Around 2000
while developing countries are CO2 R-32 R-22 R-410A R-11 R-12 R-23
obliged to gradually reduce their CFC refrigerant R-12 HCFC refrigerant R-22 HFC refrigerant R-410A
Ozone depletion 1.0 0.05 0
use from 2013, and to eliminate potential value
them by 2030. In industrialised countries, the changeover from R-22 (HCFC) to R-410A (HFC) is well underway.
Through replacement with R-410A, ozone depletion potential has been reduced to zero. However,
R-410A still has a high global warming potential. Energy Efficiency
Air conditioners are major consumers of electricity but about half of the energy 3 they use is still
Schedule of Reduction for HCFC Consumption Volumes generated by fossil fuel power plants. The CO2 discharged in this process is a known greenhouse gas.
Industrialised countries
Air conditioning manufacturers must be responsible for providing energy efficient equipment.
Developing countries
(%) Daikin has redesigned its residential-use air conditioners to use R-32. This enables its systems to
100% 100%
100 achieve new levels of energy efficiency while reducing environmental impact.
90%

80
65% 65%
60
Refrigerant is changed from gas to
Refrigerant liquid in the outdoor unit, after which
40 32.5%
25% it is evaporated in the indoor unit. During cooling operation,
cool air is discharged from the indoor unit while heat is
20
10% removed from the air taken in from inside the room. This heat
0.5% 0.5% 2.5%
0 is delivered to the outdoor unit and released.
1996 2000 2004 2010 2013 2015 2020 2025 2030 2040 (year)

Notes: 1. This value is based on in-house research.


2. Source: Values for 100 year global warming potential (GWP) from IPCC Fourth Assessment Report. Comparative 100 year GWP: HFC410A, 2,090; HFC32, 675.
3. Global energy production in 2008. Source: IEA, World Energy Outlook 2010

13 14
Benefit 3 Humidity Control

Dehumidifying: A New Level in Comfort


Two Dehumidifying Choices Sarara Dry Operation
Daikin launched the world’s first1
residential-use air conditioner to control both humidity and tempera- Urusara 7 lets you adjust the dehumidifying volume from low to high to achieve consistent comfort.
ture in 1999. By controlling humidity as well as temperature, Urusara 7 provides dehumidifying At night on rainy days, the humidity can leave you feeling hot even though the temperature is relatively
choices like you have never experienced before. low. However, using the air conditioner with conventional dry mode leads to overcooling.
Even at a relatively high set Urusara 7 maintains comfort levels by premixing the dehumidified air with room air to stabilise
temperature, selecting dehumidify- the temperature. This prevents overcooling, even for people who are sensitive to cold such as children,
ing allows you to feel cool, helping older people and women.
to save power. With Urusara 7,
you can control the indoor humidi- Conventional dry mode of Daikin models Electricity Consumption Compared with
ty directly from the wireless Conventional Daikin Dehumidifying 2
remote controller.
Two dehumidifying functions Feels too cool
are available: Sarara Dry Operation
and Dry Cooling Operation. Sarara
Dry prevents any decrease in indoor 200 W
temperature while Dry Cooling Conventional dehumidifying with heaters
activates both cooling and dehumidi- of Daikin models 105 W
fying functions at the same time.
Uses too much
electricity Conventional Sarara Dry
dehumidifying
with heaters
Operation

Room air

Even if the indoor temperature is the same,


Control of Both Humidity and Temperature you usually feel cooler with lower humidity.
This is because people release body heat by evaporating sweat on their skin. When the air is relatively dry,
sweat evaporates quickly, releasing a large amount of heat. Adjusts cooling capacity by steplessly changing the
However, when the air is humid, heat is not released and 30 activated area of the heat exchanger based on the
Airflow with a temperature
people feel hot and uncomfortable. With this in mind, Daikin has similar to the room dehumidifying volume.
28
developed technologies that create a more comfortable balance
26 Comfortable
between indoor temperature and humidity.
24
Temp.: 25˚C Temp.: 25˚C 22 3
Humidity: 80% Humidity: 50% Dry Cooling Operation

Indoor temperature ˚C
20
Selecting this function starts dehumidifying operation during cooling operation. It dehumidifies
30 40 50 60 70 80 by cooling at a low airflow rate, resulting in a lower room temperature.
Humidity %

You can experience the same comfort with an


indoor humidity of 40 to 60% even at 2˚C above
the set temperature.
Hot and humid Comfortable
Notes: 1. As of 1999, when Daikin launched Ururu Sarara in the Japanese market.
2. This is is an in-house test using models for the Japanese market.
Test conditions: Continuous operation with discharged airflow temp. 26˚C, dehumidifying volume 300
cc/h in a thermostatic chamber with indoor temp. 28˚C, indoor humidity 60%, outdoor temp. 28˚C.
3. To lower the humidity, Dry Cooling uses a lower airflow rate than standard cooling.

15 16
Benefit 4 Airflow Control

Guides the airflow along the ceiling


to avoid people and furniture. Discharges a large air volume
with the Coanda mechanism.

Delivers airflow far


from the indoor unit.

Circulation Airflow Rapidly Cools a Large Room


Urusara 7 circulates airflow and prevents temperature fluctuations even in large spaces. Daikin’s original
Coanda mechanism and Double Air Intake rapidly make even the corners of a large room feel comfortable. Circulates airflow by taking
in air from the bottom as
well as the top.
Conventional airflow of Daikin models1 Circulation Airflow 1

Airflow discharged from the unit

Airflow discharged
from the unit

It takes a long time to achieve a similar temperature in all Circulation Airflow rapidly achieves a uniform temperature in
corners of the room. each corner of the room.

Circulation Airflow Coanda Mechanism Double Air Intake


A new air discharge pattern using the Coanda effect provides a longer Cooling 4 This natural phenomenon was discovered by Henri The indoor unit features air intakes on both the top and
airflow, rapidly achieving the set temperature throughout a room. The Coanda, developer of the jet engine. The mechanism bottom. The double intakes maintain a large airflow
double air intakes and sharp-edged cross flow fan also increase airflow causes the airflow direction to alter along the surface Coanda effect volume by drawing in additional air from the bottom
The airflow direction alters
volume. This helps to circulate air around a room, preventing of an object. Daikin has used it in Urusara 7 to along the surface of an intake. The Coanda
Delivers airflow Circulates cool object.
temperature fluctuations. provide greater airflow along the ceiling. mechanism also directs
further along the air with a large
ceiling. airflow volume. increased airflow toward
Temperature distribution when cooling for seven minutes the ceiling. This helps air
to circulate fully, even if
the unit is installed near
Heating 5 the ceiling.

Without the Coanda mechanism With the Coanda mechanism


Warms with a Circulates
l tes warm air
downward airflow Notes: 1. Temperature distribution after seven minutes of Circulation Airflow operation 3. It takes seven minutes with Circulation Airflow and 15 minutes without Circulation Airflow to reach 26°C at a
with a large airflow [Temperature distribution measurement conditions] position six metres from the unit during cooling operation.
For the 5.0 kW model, the airflow distance is 12 metres 2. to the floor level. volume. Test models: 4.0 kW class model of Urusara 7 for the Japanese market [Temperature distribution measurement conditions]
The time required to reach the set temperature is only half of that for a conventional Daikin 4.0 kW class Daikin inverter model for the Japanese market withoutCirculation Airflow Test models: 4.0 kW class model of Urusara 7 for the Japanese market
inverter model 3 for the Japanese market. Test location: Daikin laboratory (room of approx. 23 m2) 4.0 kW class Daikin inverter model for the Japanese market without Circulation Airflow
Test conditions: Preset temperature 26°C, fan speed H, room temperature 35°C, outdoor temperature 35°C Test location: Daikin laboratory
2. [Measurement conditions] Test conditions: Preset temperature 26°C, fan speed H, room temperature 35°C, outdoortemperature 35°C
Test model: 4.0 kW class model of Urusara 7 for the Japanese market 4. It indicates when setting Circulation Airflow during Dry Cooling or dehumidifying. It also includes when setting
Test location: Daikin laboratory Automatic for vertical airflow direction during cooling, Dry Cooling or dehumidifying.
17 Test condition: Airflow of wind speed 0.4 m/s at a position of 12 metres from the unit and 30 millimetres 18
5. It includes when setting Automatic for vertical airflow direction during heating.
from the ceiling when setting Automatic for vertical airflow direction during cooling
Benefit 4 Airflow Control Benefit 5 Designed in Japan

Innovative Design Wins Red Dot

Breeze Airflow
Natural pattern of a gentle breeze
Urusara 7 recreates the natural pattern of a gentle breeze,
providing a cool airflow without direct draft. Based on (2) Rapidly switching wave

research by Daikin and the Prefectural University of


Kumamoto in Japan, natural breeze actually has three
(1) Large wave
components: large waves, rapidly switching waves and

Speed of airflow
precisely fluctuating waves1. Daikin has recreated this (3) Precisely
variable rhythm using its advanced airflow control fluctuating wave

technology and coanda air direction system. Time

3-D Airflow
Vertical Auto-Swing automatically moves the flaps up and down and Horizontal Auto-Swing automatically
moves the louvers to the left and right. 3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate
air to every part of a room for uniform cooling/heating of even large spaces.

4 2
Inspired by Japanese “Ogi”
3 In 2013, Urusara 7 received a prestigious Red Dot Award:
Product Design 2013 from the Design Zentrum Nordrhein
Westfalen in Essen, Germany. The internationally recognised
Red Dot has been awarded to products of outstanding quality
The flaps and louvers swing in turn, expanding the comfort zone.
since 1954.
Urusara 7 was praised for its innovative design, inspired by the Japanese “ogi” folding
fan. This is exemplified by the Coanda flap mechanism, which modifies the airflow to create
Installation Position Setting a pleasant indoor environment. Daikin’s use of R-32 refrigerant and other advanced
A pattern for the room shape and installation position can be selected with the wireless remote control- technologies also reduces energy consumption and environ-
ler. This enables control of the horizontal airflow direction to be optimised. mental impact.
Daikin believes with Urusara 7 it has created a leading air
conditioner integrating a new shape and cutting-edge technolo-
gies developed in Japan.

Six patterns can bbe selected.


l d Category: Product Design 2013

Note: 1. Based on a report issued by the Prefectural University of Kumamoto on August 31, 2012.
Test model: 4.0 kW class Daikin inverter model for the Japanese market
Test conditions: In an environment with a temperature of 27°C and relative humidity of 50%, subjects evaluated their comfort levels while seated at rest in a chair
2 m in front of the air conditioner and 850 mm above the floor. Valid responses were gathered from 16 Japanese male and female subjects in their twenties. The
evaluations of comfort/discomfort levels and airflow patterns were made over an extended period.  

19 20
Benefit 6 Air Purification

Better Indoor Air Quality Using


Streamer Technology

Prefilter Streamer discharge unit

Photocatalytic Air-Purifying
and Deodorising Filter

Mould-proof heat exchanger

Decomposition Processes with Streamer Discharge


Step 1 Generates Decomposition Elements

Streamer Technology
Streamer discharge decomposes bacteria and mould adsorbed on the filter by irradiating
them with an advanced plasma electric discharge. It provides highly effective oxidative
decomposition. Streamer discharge is one of the methods of plasma electric discharge. The streamer discharge generates The high-speed electrons hit and combine This generates high-strength
high-speed electrons. with nitrogen and oxygen in the air. decomposition elements.
With the same electrical power, the oxidative decomposition speed is over 1,000 times
faster than ordinary plasma electric discharge (glow discharge).
To achieve this performance, Daikin developed original Step 2 Decomposes Allergic Substances
technologies which successfully stabilise the flow of electrons.

Oxygen radical
Area of electron
discharge OH radical
Excited nitrogen
Primary decomposition Excited oxygen Secondary decomposition
(decomposes surface) (decomposes centre)

21 22
Benefit 5 Air Purification

Streamer Discharge Air Purifying Mould-Proof Operation


Mould and pollen are trapped and adsorbed on the Photocatalytic Air-Purifying and The streamer discharge irradiates and dries the inside of the indoor
Deodorising Filter. The streamer discharge then irradiates and decomposes the unit, heat exchanger and airflow routes. Conventional Mould-Proof
trapped particles1. It powerfully removes mould, viruses, allergic substances and Photocatalytic Air-Purifying and Operation prevents the growth of mould, but it still cannot eliminate
harmful chemical substances. The following tests are individual simulations which Deodorising Filter odour-causing bacteria. The new Mould-Proof Operation can do both
use Daikin’s streamer device2. thanks to streamer discharge and a higher operation frequency.

Virus Decomposition Mould Decomposition and Removal


Mould and Viruses3 Odour-Causing Bacteria Mould inside Indoor Unit
100 100
The streamer discharge has a powerful effect on Not irradiated Not irradiated Removal of Odour-Causing Bacteria Mould-Proof Operation prevents the growth of mould. The pictures
80 80
particles captured by the filter. below show the mould growth after three days of cooling operation.
60 60 100
Before irradiation After 15 minutes of irradiation Natural decrease
40 40 80 Without Mould-Proof Operation With Mould-Proof Operation
20 20
Irradiated Irradiated 60

Survival ratio of virus (%)


Survival ratio of virus (%)
0 1 2 3 hours 0 1 2 3 24 hours 40
Test virus: Influenza virus (type A, H1N1) Test mould: Cladosporium
Test method: Virus inactivation test Test method: Antibacterial test, mould removal test 20
Test organisation: Japan Food Research Laboratories Test organisation: Japan Food Research Laboratories
Result certificate: 10029107001-01 Result certificate: 204041635-001 Irradiated

Survival ratio of bacteria (%)


Results: The streamer unit removed 99% of the virus Results: The streamer unit removed 99% of the
in one hour. A single type of virus was used in the bacteria and mould. It has a powerful effect on 0 1 2 4 hours Mould continued to grow Mould was prevented
Cladosporium was placed on an electrode of the streamer discharge unit simulation. The test showed the unit has a powerful particles captured by the filter.
and a picture was taken using an electron microscope after 15 minutes of effect on virus particles captured by the filter. Test room: Chamber of approx. 10 m2 in a laboratory at the Institute of Environmental Biology in Japan
Test method: Filters were compared on a testing device with and without the streamer
discharge. discharge to check their ability to adsorb mould and odour-causing bacteria. Test method: Two indoor units were fitted with mould sensors owned by the Institute of
Test organisation: Japan Food Research Laboratories Environmental Biology. One unit was run using Mould-Proof Operation during cooling operation
Test location: Japan while the other was run using only cooling operation. After two weeks of use (8 hours per day),
Result certificate: 10072482001-01 the lengths of hyphae on the sensors were compared.
Allergic Substances Odour Results: The streamer discharge decomposed and removed 99.9% of mould in 24 hours Test conditions: Temperature: 27˚C, humidity: 70%, mould attached to the sensors: Eurotium
and 99.7% of odour-causing bacteria in one hour. The test was conducted using only one herbariorum J-183
type of bacterium. Test organisation: Institute of Environmental Biology
The streamer discharge decomposes the centre of Odour-causing particles are adsorbed by the filter Result certificate: 100805, 100806, 100807
pollen and dead mites. and decomposed by the streamer. There is little loss Test machine: Model for the Japanese market similar to the 2.5 kW class Urusara 7 model
of deodorising effect due to the automatic regenera-
Before irradiation After 15 minutes of irradiation
tion of adsorption power.

Rubbish Pets Toilets Mould-Proof Heat Exchanger


Cause of
odour Mould Cooking Tobacco
Surface stains are washed off the indoor heat exchanger using water generated by the
cooling or dry operations. The surface is protected with a mould-proof coating.
Ceadar pollen was placed on an electrode of the streamer discharge unit and a
picture was taken using an electron microscope after 15 minutes of discharge.
Removable allergic substances Mould-proof
Mould: Alternaria, aspergillus, eurotium, cladosporium, fusarium, heat exchanger 4
penicillium Coating Removed
Pollen: Cedar, alder, birch, Japanese cypress, pencil cedar, bald with water
Exhaust Gas and Diesel Particles cypress, mugwort, orchard grass, ragweed, sweet vernal grass, Surface
timothy grass, plantain, beech tree stains Water
The streamer discharge decomposes exhaust gas Biological: House dust mite (dermatophagoides pteronyssinus)
(droppings and dead mites), house dust mite (dermatophagoides
and diesel particles. farunae) (droppings and dead mites), American cockroach Fin of heat
(droppings), German cockroach (droppings), dog epitherium exchanger
Before irradiation After 15 minutes of irradiation (dander), cat epitherium (dander), flea (droppings), hamster
epitherium (dander) Cleaning of the heat exchanger may be required if the indoor unit is installed in a kitchen where
Other: Wheat flour dust 30 allergic substances in total oil is used, or a hair salon where dyes and chemicals are used.

Removable harmful chemical substances


Diesel particles (DEP)
VOC (volatile organic compound)-type harmful chemical
substances: Acetone, 2-propanol, dichloromethane, ethyl
acetate, hexane, 2,4-dimethylpentane, benzene, Notes: 1. The decomposition is effective only for substances adsorbed on the Photocatalytic Air-Purifying and Deodorising Filter. This product is not designed as a medical
1,2-dichloropropane, trichloroethylene, methyl isobutyl ketone, device and should not be used for medical applications.
Diesel particles were placed on an electrode of the streamer discharge unit and 2. The results may differ slightly from actual conditions as they are based on simulations using a testing device equipped with a streamer unit. They do not use an actual
butyl acetate, octane 12 substances in total
a picture was taken using an electron microscope after 15 minutes of discharge. air conditioner.
3. Virus particles with the same characteristics as those adsorbed on a filter were irradiated in a testing device. The test used both the same type of discharge unit and
same action as those in an actual product. The distance and installation position were also the same. This in-house simulation was conducted in Japan.
4. Testing method: Harrow method based on the standards of the Home Electric Appliances Fair Trade Conference; Testing organisation: Kyoto Biseibutu Kenkyusho;
Result certificate: 09217433-1

23 24
Benefit 7 Automatic Filter Cleaning

Quiet Operation and Timers

Clean Air, Every Day Quiet Operating Sound of 19 dB (A)


Indoor Unit Quiet Operation
This series gives you a choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting
selects Indoor Unit Quiet Operation, which decreases the sound pressure level by 7 to 10 dB (A) below
the Low setting.
This wide range of settings allows you to precisely control the fan speed according to your needs.
For example, the Quiet function will help you to sleep comfortably at night. The sound pressure level for
the FTXZ25N and FTXZ35N is 19 dB (A).

FTXZ35N during cooling operation


Fan speeds Sound pressure levels

High (H) 42 dB (A)

Low (L) 27 dB (A)


8 dB (A)
Quiet (SL) 19 dB (A)

Auto SL L M H

Cleaning Filter Operation Fan speed Low High

You no longer have to clean the prefilter. After operation stops, this function automatically brushes dust Each decrease in airflow volume reduces the
Sound pressure level
sound pressure level.
off the prefilter and collects it in the installed dust box. Cleaning automatically starts after 18 hours or
more of cumulative operation. The cleaning lasts
a maximum of 11 minutes and once the Mould- Electricity Consumption after One Year of Operation
Proof/Cleaning Filter lamp starts blinking, you only Without Cleaning
125%
Filter Operation
need to discard the dust collected in the box. This Outdoor Unit Quiet Operation
With Cleaning
helps to maintain filter performance and prevent Filter Operation 100%
energy loss. This function decreases the sound pressure level from the rated operation (H). It can be started easily
This function prevents reduced operational performance caused
by dust collecting on the prefilter. It decreases annual electricity from the wireless remote controller. (Capacity may decrease during Outdoor Unit Quiet Operation.)
consumption by 25%1.

How Is the Filter Cleaned?

19 dB (A) Is So Quiet You Can Even Hear Whispers1


Indoor unit Outdoor unit

19 20 30 40 43 50
(dB (A))

The prefilter is automatically moved The brush removes dust attached to The removed dust is collected in the Rustling of leaves Library
downwards. the prefilter. dust box.
Pendulum of a wall clock Normal office

Note: 1. Test method: In-house simulation based on JRA4046-2004


Test conditions: Approx. 2 g of material was attached to the filter to represent one year of use.
Test model: Model for the Japanese market similar to Urusara 7
Annual electricity consumption: 1,145 kWh when the Cleaning Filter Operation was used; 1,432 Note: 1. Based on “Examples of Sound Pressure Levels”, Ministry of the Environment, Japan, November 12, 2002
kWh when the Cleaning Filter Operation was not used.
25 26
Quiet Operation and Timers

Promising You a Good Night’s Sleep


Comfort Sleep Timer
More than 50% of people claim to have disturbed sleep1. Daikin
This function controls the indoor temperature while Mechanism of Good Sleep has developed the new Comfort Sleep Timer specifically to
you are asleep, helping to produce body temperature address this problem. The timer utilises the core body tempera-
patterns which promote restful sleep. The programme ture concept, in which a lower temperature is thought to deepen Increase in Deep Sleep
controls the temperature using a V-shaped pattern sleep while a higher temperature makes it easier to wake up. 100
Restful sleep is achieved by gradually changing the body tempera- 35% increase
which is similar to the human body’s normal tempera-
ture during the night. 80
ture fluctuation pattern. You only need to set your
wakeup time. 88
High 60
Deep sleep (min.)

65
Body temperature fluctuation pattern V-shaped pattern programme 40
Constant temperature V-shaped pattern
Body temperature Set temperature control programme
Low
Core body temperature

On The increase in deep sleep was tested by Daikin


Normal core body During the night, you In the morning, you gradually Environmental Laboratory, Ltd. The V-shaped
38˚C You awake feeling temperature before feel sleepier as your core wake up as your core body
refreshed pattern programme increased deep sleep by
sleep body temperature falls. temperature rises. 35% 2 (Data for 5 hours of sleep).
–1˚C
37˚C
Awakening
–2˚C Accelerates onset
of deep sleep
36˚C Total Time Spent in Deep Sleep (Experiment Results)
3 hours 2 hours 1 hour

Time 9:00 6:00 Sleep 0:00 3:00 6:00 Wakeup Sleep time 0 1 2 3 4 5 6 Constant temperature control V-shaped pattern programme
a.m. p.m. a.m. a.m. a.m.
Accelerates onset of deep sleep 120
Body temperatures drop slowly as people begin to sleep and rise
as their wakeup time approaches. The room temperature drops slowly as you begin to sleep, lowering your
body temperature while you are asleep.
100
You awake feeling refreshed
The room temperature rises as your wakeup time approaches, causing your
body temperature to rise just before you awake.
80
Required deep sleep

Daily On/Off Timer 60

3 hours difference
Both the operation start and stop time can be preset. With this timer, the air conditioner starts and stops 40
at the same time every day. Using the Daily On Timer ensures your living room and bedroom are cool
Total time spent in deep sleep (min.)

when you come home and go to sleep. 20

Time (min.)
0 60 120 180 240 300 360 420
Countdown Off Timer
The operation stop time can be set with the touch of a single button and preset for a period of 0.5 to 9.5 V-shaped pattern programme Constant temp. control
hours in 30 minute increments. Set 4 and the unit will stop after four hours. This is convenient if you want
90 minutes of 90 minutes of
to maintain cooling or dry operation during the night even if you do not use the Daily Off Timer. deep sleep deep sleep
3 hours of sleep 6 hours of sleep

Daily On/Off Timer Starts and/or stops daily operation at the same time. To experience satisfying sleep, you need 90 minutes of deep sleep. Three hours of sleep is necessary
with the V-shaped pattern programme and six with the constant temperature control.

Countdown Off Timer Stops operation in 30 minute increments.

Notes: 1. Japanese Society of Sleep Research, “Comfort Sleep Experiment Research 2002”
2. This result was obtained through research. There are wide differences between individuals.

27 28
Controller

Easy to See during the Night


Humidity and Energy Indications
Frequently used functions are located on the front of the wireless remote controller for quick
access. A large liquid crystal display and backlit buttons also allow easy operation in the
dark. The LCD provides a range of information, including indoor and outdoor temperatures,
humidity and power consumption.
Remote controller
holder Starts operation.
Automatic Operation

Off switch

Starts dehumidifying operation.


Starts cooling operation. Sarara Dry Operation
Projection
Hole
Starts heating operation. Inverter Powerful Operation

Selects dehumidifying power:


Continuous, High, Standard, Low, Off.
Sets room temperature. Dry Cooling Operation
Backlit buttons are easy to see The rounded controller is easy to operate The remote controller holder is a
in the dark. even for elderly people. standard accessory.

Selects fan speed.


Streamer Discharge Air Purifying Indoor Unit Quiet Operation
Pushing the Information Display button allows you to check the humidity
and power consumption. Countdown Off Timer

Sets vertical airflow direction.


Circulation Airflow, Breeze Airflow,
Vertical Auto-Swing and
Sets horizontal airflow direction.
3-D Airflow
Horizontal Auto-Swing and
3-Area Intelligent Eye 3-D Airflow
(Focus and Comfort) and Econo Mode and
Auto Off Operation Outdoor Unit Quiet Operation
Indoor Indoor Outdoor
temperature humidity temperature
Starts fan only operation. Mould-Proof Operation

Child-Proof Lock Cleaning Filter Operation


Installation Position Setting
Information Display
Indoor Unit Lamp Brightness Setting
Completes controller setting.
Sets timers.
Cancels timers.
Resets dust box and
streamer unit cleaning indicators. Sets clock.

Buttons for detailed settings such as timers and airflow


Current power Total power
consumption consumption direction are gathered under the cover.

29 30
Functions
Comfortable Airflow Lifestyle Convenience Comfort Control Cleanliness
3-Area Intelligent Eye (Focus) Auto Off Operation Sarara Dry Operation Streamer Discharge Air Purifying
Intelligent Eye has infrared sensors which detect human movement Auto Off Operation uses 3-Area Intelligent Eye to This dehumidifying function stabilises the room temperature The streamer discharge decomposes bacteria and mould
in left, right and centre zones. Intelligent Eye Focus automatically automatically stop operation if no movement is detected in a and prevents overcooling, even for people who are particularly adsorbed by the indoor unit’s photocatalytic filter. After the
adjusts horizontal airflow to send air directly to a person. room. A detection period of one or three hours can be set. sensitive to cold. particles are trapped, they are irradiated by the streamer device.
See page 11 See page 12 See page 16 See pages 21 to 23
3-Area Intelligent Eye (Comfort) Standby Electricity Saving Dry Cooling Operation Mould-Proof Operation
Intelligent Eye has infrared sensors which detect human movement Even when an air conditioner is not operating, it requires This combined dehumidifying and cooling operation The streamer discharge dries the inside of the indoor unit,
in left, right and centre zones. Intelligent Eye Comfort automatically standby power. However, thanks to this function, the required dehumidifies by cooling at a low airflow rate, resulting in a heat exchanger and airflow routes. It effectively prevents the
adjusts horizontal airflow to avoid blowing air onto a person. standby power can be reduced. lower room temperature. growth of both mould and odour-causing bacteria.
See page 11 See page 11 See page 16 See page 24
Cleaning Filter Operation
Circulation Airflow Econo Mode Indoor Unit Quiet Operation
After operation stops, this function automatically brushes
This function uses the Coanda effect to rapidly achieve the set This mode limits maximum running current and power Indoor unit operating sound pressure levels are decreased by dust off the prefilter and collects it in a box. This helps to
temperature. The double air intakes and cross flow fan consumption. This improves operating efficiency and also 7 to 10 dB (A) from the Low setting fan speed using the maintain filter performance and energy efficiency.
increase airflow to circulate air around a room. prevents circuit breakers from being overloaded. wireless remote controller. See page 25
See page 11 See page 26
See page 17
Outdoor Unit Quiet Operation Photocatalytic Air-Purifying and
Breeze Airflow Inverter Powerful Operation Deodorising Filter
This function recreates the natural rhythm of a gentle breeze. This function is convenient for boosting cooling/heating Outdoor unit operating sound pressure levels are decreased from
the rated operation sound using the wireless remote controller. While the filter’s micron-level fibres are able to effectively
With this airflow pattern, even people who are sensitive to performance for a 20 minute period both when the air trap dust, its photocatalyst has the ability to adsorb odours.
conditioner is first turned on or it is necessary to change the See page 26
drafts feel comfortable when air is directed towards them. See page 23
See page 19 room temperature quickly.
Automatic Operation Wipe-Clean Flat Panel
Power-Airflow Flap This function automatically selects cooling or heating The flat panel design can be cleaned with only the single
The Power-Airflow Flap can flatten out during cooling operation mode based on the room temperature at start-up. pass of a cloth across its smooth surface. The flat panel can
operation to deliver cool air to the corners of a room. The also be easily removed for more thorough cleaning.
flap can direct warm air straight down to the floor during
heating operation. Auto Fan Speed
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature. Worry Free
Wide-Angle Louvers
The smoothly curved Wide-Angle Louvers provide wide Child-Proof Lock
airflow coverage for effective operation no matter where the Information Display Hot-Start Function
indoor unit is placed in a room. The LCD provides various details on current operation, After defrosting or when starting heating operation, air is pre- This function allows users to lock operation using the
including temperature and humidity. It also displays heated before discharge to prevent uncomfortable cold drafts. wireless remote controller. It is useful for preventing setting
information such as total energy use over several days. changes if children play with the controller.
See page 29
Auto-Restart after Power Failure
Wireless Remote Controller with Backlight Timers The air conditioner memorises the settings for mode, airflow,
The large LCD and backlit buttons allow easy operation in the temperature, etc., and automatically returns to them when
From a corner Covers even dark. Frequently used functions are conveniently located on power is restored after a power failure.
to the centre a spacious room the front of the controller. Comfort Sleep Timer
See page 29 This function controls the indoor temperature using a Self-Diagnosis with Digital Display
V-shaped pattern based on sleep science, helping to promote Malfunction codes are shown on the digital display panel of
Installation Position Setting Indoor Unit Lamp Brightness Setting restful sleep. It is only necessary to set a wakeup time. the wireless remote controller for fast and easy maintenance.
The room shape and installation position can be set on the The indoor unit is equipped with an operation lamp, timer See page 27
wireless remote controller. This enables optimal control of lamp and various other indicators. The brightness of these Anticorrosion Treatment of Outdoor
the horizontal airflow direction. lamps can be adjusted to High, Low or Off. Daily On/Off Timer Heat Exchanger Fins
See page 19 This timer allows users to set the operation start and stop times
so the air conditioner turns on and off at the same time every day. The outdoor unit’s heat exchanger fins are processed using a
special anticorrosion treatment. The surface is covered with
Vertical Auto-Swing (up and down) See page 27
a thin acrylic resin layer to enhance the fins’ resistance to
This function automatically moves the flaps up and down to acid rain and salt corrosion.
distribute air across a room. Countdown Off Timer Cross section of anticorrosion-treated fin
The operation stop time can be preset for a period of 0.5 to Hydrophilic film
9.5 hours in 30 minute increments. Aluminium
Horizontal Auto-Swing (left and right) See page 27 Corrosion-resistant
acrylic resin
Horizontal Auto-Swing automatically moves the louvers to the
left and right to cover a room with cool/warm air. Indoor Unit On/Off Switch 24-Hour On/Off Timer
The unit can be conveniently started manually in the event the This timer can start or stop the air conditioner within a 24-hour
wireless remote controller is misplaced or the wireless remote period. It can be preset in 10-minute steps by pressing the
3-D Airflow controller batteries are not charged. On/Off timer button on the wireless remote controller. The On
Heat exchanger fin
This function combines Vertical and Horizontal Auto-Swing to timer and Off timer can be used in combination.
circulate a cloud of cool/warm air right to the corners of even
large spaces. The flaps and louvers swing in turn. Quick Heating Timer
See page 19 Heating operation can be preset to turn on one minute after Automatic Defrosting
the set wakeup time. Warm airflow starts just one minute later. Before starting heating operation, a sensor checks for frost in
the outdoor unit and performs automatic defrosting if
necessary so that only warm air is discharged.
31 32
Specifications Options
Indoor Unit
Indoor unit FTXZ25NVM FTXZ35NVM FTXZ50NVM No. Item FTXZ25/35/50N
Model name
Outdoor unit RXZ25NVM RXZ35NVM RXZ50NVM 1 5-room centralised controller *1 KRC72A
kW 2.45 (0.6-3.9) 3.45 (0.6-5.3) 4.95 (0.6-5.8) Wiring adaptor for time clock/remote controller *2
Cooling Rated 2 KRP413AB1S
(Min.-Max.) Btu/h 8,400 (2,000-13,300) 11,800 (2,000-18,100) 16,900 (2,000-19,800) (Normal open pulse contact/normal open contact)
Capacity
Rated kW 3.6 (0.6-7.5) 5.0 (0.6-9.0) 6.3 (0.6-9.4) 3 Photocatalytic air-purifying and deodorising filter set *3 KAF046A41
Heating
(Min.-Max.) Btu/h 12,300 (2,000-25,600) 17,100 (2,000-30,700) 21,500 (2,000-32,100) 4 Remote controller loss prevention with chain KKF936A4
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. The time clock and other devices should be obtained locally.
Running current Cooling 2.1-2.0-2.0/2.1-2.0 3.2-3.0-2.9/3.2-3.0 5.3-5.1-4.8/5.3-5.1 *3. The filter is a standard accessory.
(220-230-240 V, 50 Hz/ Rated A
220-230 V, 60 Hz) Heating 2.9-2.8-2.7/2.9-2.8 4.6-4.4-4.3/4.6-4.4 6.5-6.2-6.0/6.5-6.2
Cooling Rated 430 (110-880) 680 (110-1,330) 1,150 (110-1,600)
Power consumption W
Heating (Min.-Max.) 620 (100-2,010) 1,000 (100-2,530) 1,410 (100-2,640)
Cooling Rated 5.70 (5.45-4.43) 5.07 (5.45-3.98) 4.30 (5.45-3.63)
COP W/W
Heating (Min.-Max.) 5.81 (6.00-3.73) 5.00 (6.00-3.56) 4.47 (6.00-3.56)
5-room centralised controller Photocatalytic air-purifying and Remote controller loss
Indoor unit FTXZ25NVM FTXZ35NVM FTXZ50NVM KRC72A deodorising filter prevention with chain
Front panel colour White KAF046A41 KKF936A4
Cooling m3/min 10.7 (379) 12.1 (428) 15.0 (545)
Airflow rate (H)
Heating (cfm) 11.7 (415) 13.3 (469) 14.4 (517) Outdoor Unit
Fan speed 5 steps, quiet and automatic No. Item RXZ25/35/50N
Sound pressure levels Cooling 38/26/19 42/27/19 47/30/23 1 Air direction adjustment grille KPW937D4
dB (A)
(H/L/SL) Heating 39/28/19 42/29/19 44/31/24 Drain plug *1
2 KKP937A4
Dimensions (H x W x D) mm 295 x 798 x 370 Note: *1. One set includes 5 pieces for 5 units.
Machine weight kg 15
Outdoor unit RXZ25NVM RXZ35NVM RXZ50NVM
Casing colour Ivory white
Compressor type Hermetically sealed swing type
Air direction adjustment grille Drain plug
Refrigerant charge (R-32) kg 1.34 KPW937D4 KKP937A4
Sound pressure levels Cooling dB (A)
46 48 49
(H) Heating 46 48 50 Control System
Dimensions (H x W x D) mm 595 x 795 x 300
No. Item FTXZ25/35/50N
Machine weight kg 43 *1
1 Central remote controller DCS302CA61
Cooling CDB –10 to 43 *1
Operation range 2 Unified On/Off controller DCS301BA61
Heating CWB –20 to 18
3 Schedule timer *1 DST301BA61
Liquid 6.4
4 Interface adaptor for DIII-NET use KRP928BB2S
Piping Gas 9.5
mm Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
connection Indoor unit: I.D. 16.0, O.D. 18.0
Drain
Outdoor unit: I.D. 15.9
Max. piping length 30
m
Max. height difference 12
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. Central remote controller Unified On/Off controller Schedule timer
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound pressure levels are based on the temperature conditions 1 and 2 above. These are anechoic conversion values. These values are normally somewhat higher during DCS302CA61 DCS301BA61 DST301BA61
actual operation as a result of ambient conditions.
33 34

You might also like