Continental - Hydraulic Valves-Electronic Boards PDF
Continental - Hydraulic Valves-Electronic Boards PDF
PowrFlow TM
Electro-hydraulic Proportional
and ServoControl
VALVE ACCESSORIES
P03MSV-RCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61-64
MISCELLANEOUS
NFPA Mounting Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101-104
Fluid Power Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105-106
1
ELECTRO-HYDRAULIC PRODUCTS
FEATURES - “DESIGNED FOR THE WAY YOU WORK”
Proportional Valves
• Fast Response
• Flows to 150 gpm (567 lpm)
• Standard mountings – NFPA & ISO
standard or line mount
• LVDT for closed inner loop applications
• Hysteresis of 1% with LVDT
2
ELECTRO-HYDRAULIC PRODUCTS
Proportional Directional, Proportional Cartridge,
and Pressure Control Valves
VALVES
3
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
4
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
5
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
315
270
AMPLITUDE RATIO (dB)
Amplitude Ratio
0
225
180
135
-3
90
45
Phase Lag
-6 0
1 5 7 10 30 60 100
FREQUENCY (Hz)
6
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
300 300
4000 4000
AC/FC-03
PRESSURE DROP
PRESSURE DROP
100 AC/FC-26
100 AC/FC-21
1000 1000
0 0 0 0
0 2 4 6 8 10 12 gpm 0 2 4 6 8 10 12 14 gpm
0 10 20 30 40 lpm 0 10 20 30 40 50 lpm
FLOW FLOW
300 300
4000 4000
PRESSURE DROP
PRESSURE DROP
AI/FI-05 AI/FI-25
3000 200
3000 200 AI/FI-31
2000
2000
100
100 AI/FI-15 1000
AI/FI-20
1000
0 0
0 2 4 6 8 10 12 14 16 gpm
0 0
0 2 4 6 8 10 12 14 gpm 0 10 20 30 40 50 60 lpm
FLOW
0 10 20 30 40 50 lpm
FLOW
300 300
4000
4000
PRESSURE DROP
PRESSURE DROP
AO/FO-20
3000 200
3000 200 AO/FO-31
AO/FO-15
2000
2000 AO/FO-25
100
100 1000
1000
0 0
0 2 4 6 8 10 12 14 16 18 gpm
0 0
0 2 4 6 8 10 12 14 16 gpm 0 10 20 30 40 50 60 lpm
0 10 20 30 40 50 60 lpm FLOW
FLOW
7
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
FLOW
(21 bar) (21 bar)
0 0 1.0 3.8
0 20 40 60 80 100
COMMAND SIGNAL (%) 0 0
0 20 40 60 80 100
COMMAND SIGNAL (%)
300 psid
6.0 22.7 (21 bar) 6.0 22.7 145 psid
(10 bar)
145 psid 72 psid
4.0 15.1 (10 bar) 4.0 15.1 (5 bar)
72 psid
(5 bar) 7.6
2.0 7.6 2.0
0 0 0 0
0 20 40 60 80 100 0 20 40 60 80 100
COMMAND SIGNAL (%) COMMAND SIGNAL (%)
AC/FC-26 Spool
gpm lpm
14.0 53.0
500 psid
12.0 45.4 (27 bar)
300 psid
10.0 37.8 (21 bar)
8.0 30.3
FLOW
145 psid
(10 bar)
6.0 22.7
72 psid
(5 bar)
4.0 15.1
2.0 7.6
0 0
0 20 40 60 80 100
COMMAND SIGNAL (%)
8
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
FLOW
(21 bar)
2.5 9.5 500 psid 5.0 18.9
(27 bar) 145 psid
4.0 15.1
FLOW
(10 bar)
2.0 7.6
300 psid 3.0 11.3 72 psid
(21 bar) (5 bar)
1.5 5.7 2.0 7.6
145 psid 1.0 3.8
(10 bar)
1.0 3.8 0 0
72 psid 0 20 40 60 80 100
(5 bar)
0.5 1.9 COMMAND SIGNAL (%)
0 0
0 20 40 60 80 100
COMMAND SIGNAL (%)
145 psid
6.0 22.7 145 psid
6.0 22.7 (10 bar)
(10 bar)
72 psid
4.0 15.1 72 psid 4.0 15.1 (5 bar)
(5 bar)
0 0 0 0
0 20 40 60 80 100 0 20 40 60 80 100
COMMAND SIGNAL (%) COMMAND SIGNAL (%)
AO/FO-31 Spool
gpm lpm
14.0 53.0
500 psid
12.0 45.4 (27 bar)
300 psid
10.0 37.8 (21 bar)
8.0 30.3
FLOW
145 psid
(10 bar)
6.0 22.7
72 psid
(5 bar)
4.0 15.1
2.0 7.6
0 0
0 20 40 60 80 100
COMMAND SIGNAL (%)
9
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
FLOW
(21 bar) (21 bar)
0 0 1.0 3.8
0 20 40 60 80 100
COMMAND SIGNAL (%) 0 0
0 20 40 60 80 100
COMMAND SIGNAL (%)
300 psid
6.0 22.7 (21 bar) 6.0 22.7 145 psid
(10 bar)
145 psid 72 psid
4.0 15.1 (10 bar) 4.0 15.1 (5 bar)
72 psid
(5 bar) 7.6
2.0 7.6 2.0
0 0 0 0
0 20 40 60 80 100 0 20 40 60 80 100
COMMAND SIGNAL (%) COMMAND SIGNAL (%)
AC/FC-26 Spool
gpm lpm
14.0 53.0
500 psid
12.0 45.4 (27 bar)
300 psid
10.0 37.8 (21 bar)
8.0 30.3
FLOW
145 psid
(10 bar)
6.0 22.7
72 psid
(5 bar)
4.0 15.1
2.0 7.6
0 0
0 20 40 60 80 100
COMMAND SIGNAL (%)
10
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
11
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
3.76
(95.5) 2.82
(71.6)
3.76
(95.5) 2.82
(71.6)
1
Laptop PC
VEA-3P7P-A
Power
Cable
1
Desktop PC
1
2
PIN
2 Compact Flash
VEA-3P7M-A
Serial I/O
SOCKET Cable
PDA
12
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
2.93
(74.4)
3.36
2.09 (85.3) 2.15
(53.1) 2.26 (54.6)
(57.4)
2.93
(74.4)
3.36
(85.3) 2.09 2.15
2.26 (53.1) (54.6)
(57.4)
13
VED03M
Proportional Directional Control Valves
SOLENOID ACTUATED, DIRECT ACTING W/ON-BOARD ELECTRONICS
ORDERING INFORMATION
SELECT SELECT SELECT SELECT SELECT SELECT DESIGN
ONE ONE ONE IF REQ’D IF REQ’D ONE LETTER
VED03M G L A
P T ON-BOARD
DOUBLE OPERATOR w/OB ELECTRONICS
3 3 POSITION 7 PIN
SPRING CENTERED OB
A B
Sol.
B
Sol.
A CONNECTION
P T
INTERNAL
HALL LOOP SOLENOID
Standard Valve
CODE VOLTAGE
Sol.
A B 12 12 VDC
24 24 VDC
U
b S
P T
SINGLE OPERATOR w/OB
5 2 POSITION
SPRING CENTERED Sol.
A B
P T
Standard Valve
MECHANICAL OPTIONS
CODE DESCRIPTION
STANDARD
DOUBLE
SOLENOID AND
OMIT
SINGLE
SOLENOID
“A” PORT END
SINGLE
R SOLENOID
SPOOL FUNCTION FLOW RATES SEALS “B” PORT END
14
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITHOUT LVDT
Meter-out spools (code "O") meter flow out of the actuator. Continuous @ rated
operating with
These spools are commonly used in applications with "run
DUTY CYCLE 120° F. (49° C.) fluid
away" loads such as over-center loads. Meter-out spools and 100° F. (38° C.)
are also used with high ratio cylinders. ambient temperature
15
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITHOUT LVDT
3000 200
A
PRESSURE DROP
CURVE NO. 1 2 3 4
B
100 SPOOL
F2O F1O
1000 F2I F1I
A
0 0
P
0 5 10 15 20 25 gpm
0 15 30 45 60 75 90 lpm
FLOW
POSITION
POSITION
“A” “B”
CROSS-
CROSS-
CENTER
PORT PORT
OVER
OVER
FLOW
FLOW
END END
2 210
A B
A C Spool AMPLITUDE RATIO
0 180
Combination
P T -2 150
A B
TESTED WITH CHD
A O Spool -4 AMPLIFIER 120
Meter-Out ECM4-L4-P1T1-C
P T
1000 PSI @ RATED
-6 FLOW WITH SPOOL 90
A B
FULLY SHIFTED
A I Spool OIL: 150 VG 32 @ +120° F.
Meter-In -8 60
P T
A B - 10 30
F C Spool PHASE LAG
Combination
Metering
- 12 0
.1 .5 1. 2 4 6 8 10 20 30 40
P T
A B
FREQUENCY (HZ)
F O Spool
Meter-Out
P T
A B
F I Spool
Meter-In
P T
16
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITHOUT LVDT
gpm lpm
28 105
24 90
300 psid (21 bar)
20 75
16 60
FLOW
12 45
72 psid (5 bar)
8 30
4 15
25 50 75 100
INPUT SIGNAL (%)
NOTES:
These curves were run at no load flow condition,
ISO VG32 fluid @ 120° F. (49° C.).
Pressure drop will change with viscosity.
A1C and F1C Spools Curves are full flow ΔP.
Nominal 13 gpm (50 lpm) Conversions: 1 gpm = 3.79 lpm; 1 bar = 14.5 psi.
gpm lpm
28 105
24 90
16 60
8 30
4 15
25 50 75 100
INPUT SIGNAL (%)
17
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITHOUT LVDT
gpm lpm
28 105
24 90
20 75
FLOW
8 30 72 psid (5 bar)
4 15
25 50 75 100
INPUT SIGNAL (%)
NOTES:
These curves were run at no load flow condition,
ISO VG32 fluid @ 120° F. (49° C.).
Pressure drop will change with viscosity.
A2C and F2C Spools Curves are full flow ΔP.
Nominal 9 gpm (34 lpm) Conversions: 1 gpm = 3.79 lpm; 1 bar = 14.5 psi.
gpm lpm
14 52
300 psid (21 bar)
12 45
10 38
145 psid (10 bar)
FLOW
8 30
6 23 72 psid (5 bar)
4 15
2 8
25 50 75 100
INPUT SIGNAL (%)
18
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITHOUT LVDT
1/2-14 NPTF
5-PIN CONNECTOR
OPTION (CODE B5H)
4.92
(125.0) SOLENOID "b" SOLENOID "a"
7 LBS.-FT TORQUE
FOR SOLENOID NUT
1/2 -14 NPTF BOTH SIDES
MANUAL OVERIDE PIN
(SOLENOID ENDS ONLY)
BLACK PLUG GREY PLUG
DIN CONNECTOR
(CODE D)
4.31
(109.4)
3.89 3.25
(98.8) (82.6)
(4) 1.25
(31.8)
SOLENOID "b" SOLENOID "a"
"A" PORT END "B" PORT END
3.56 2.69
(90.4) (68.3)
9.10
(231.1)
14.10
(358.0)
NOTES:
1. Electrical box may be rotated 180° (Codes B, BT, and B5H).
2. 5-pin disconnect meets NFPA recommende standard T3.5.29 R1 - 2003.
3. Two (2) lead wires for each solenoid 6 inches (152.4 mm) long (except
Code D) and ground screw are provided by removing the top cover plate.
4. Four (4) mounting bolts are torqued to 10 - 12 lbs.-ft. (13.5 - 16.3 Nm).
SCHEMATICS
Code 3 Code 5
A B A B
P T P T
19
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITHOUT LVDT
ED05M G L C
MECHANICAL OPTIONS
CODE DESCRIPTION
OMIT NONE
REVERSE ASSEMBLY
R SINGLE SOLENOID
ON “B” PORT END
20
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITH LVDT
Combination metering spools (code "C") meter oil into and DEADBAND 10% nominal
out of the hydraulic actuator. These spools provide excellent of spool travel
control in most applications. Combination metering spools VOLTAGE Code 12 12 VDC
are highly recommended where deceleration control of a (Nominal) Code 24 24 VDC
hydraulic motor is required or in velocity feedback
applications. Combination metering spools can be used with CURRENT Code 12 3.0 Amp
(Maximum) Code 24 1.5 Amp
a pressure-compensated module to provide proportional
pressure compensated flow. WATTAGE (I2 R) Code 12 26
@ 76° F. (24° C.) Code 24 26
Meter-in spools (code "I") meter oil into the actuator. These (Continuous)
spools are commonly used in applications where the
actuator is always working against a positive (resistive) COIL Code 12 2.9 Ohms
RESISTANCE
load. Meter-in spools can also be used with a pressure Code 24 11.4 Ohms
@ 68° F. (20° C.)
compensated module.
Continuous @ rated
Meter-out spools (code "O") meter flow out of the actuator. operating with
These spools are commonly used in applications with "run DUTY CYCLE 120° F. (49° C.) fluid
away" loads such as over-center loads. Meter-out spools and 100° F. (38° C.)
are also used with high ratio cylinders. ambient temperature
psid bar
3500
A
3000 200
PRESSURE DROP
B
CURVE NO. 1 2 3 4
2000
A2C A2O A1C A1O
T or P
0 0
A
0 5 10 15 20 25 30 gpm
0 15 30 45 60 75 90 105 lpm
P
FLOW
POSITION
POSITION
“A” “B”
CROSS-
CROSS-
CENTER
PORT PORT
OVER
OVER
FLOW
FLOW
END END
2 210
A B
A C Spool AMPLITUDE RATIO
Combination 0 180
Metering
P T
-2 150
A B TESTED WITH CHD
AMPLIFIER
A O Spool -4 ECM4-L4-P1T1-C 120
Meter-Out
1000 PSI @ RATED
P T
-6 FLOW WITH SPOOL 90
A B FULLY SHIFTED
OIL: 150 VG 32 @
A I Spool
-8 +120° F. 60
Meter-In
P T
- 10 30
A B
F C Spool
PHASE LAG
Combination - 12 0
Metering .1 .5 1.0 2 3 4 6 8 10 20 30 40
P T
FREQUENCY (HZ)
A B
F O Spool
Meter-Out
P T
A B
F I Spool
Meter-In
P T
22
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITH LVDT
gpm lpm
32 120
550 psid (38 bar)
28 105
24 90
300 psid (21 bar)
20 75
FLOW
12 45 72 psid (5 bar)
8 30
4 15
25 50 75 100
INPUT SIGNAL (%) NOTES:
These curves were run at no load flow condition,
ISO VG32 fluid @ 120° F. (49° C.).
Pressure drop will change with viscosity.
A1C and F1C Spools Curves are full flow ΔP.
Nominal 13 gpm (50 lpm) Conversions: 1 gpm = 3.79 lpm; 1 bar = 14.5 psi.
gpm lpm
28 105
600 psid (41 bar)
24 90
16 60
8 30
4 15
25 50 75 100
INPUT SIGNAL (%)
23
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITH LVDT
gpm lpm
28 105
20 75
FLOW
12 45
145 psid (10 bar)
8 30 72 psid (5 bar)
4 15
25 50 75 100
INPUT SIGNAL (%)
NOTES:
These curves were run at no load flow condition,
ISO VG32 fluid @ 120° F. (49° C.).
Pressure drop will change with viscosity.
A2C and F2C Spools Curves are full flow ΔP.
Nominal 9 gpm (34 lpm) Conversions: 1 gpm = 3.79 lpm; 1 bar = 14.5 psi.
gpm lpm
28 105
24 90
600 psid (41 bar)
20 75
FLOW
16 60
4 15
25 50 75 100
INPUT SIGNAL (%)
24
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITH LVDT
1/2-14 NPTF
5-PIN
CONNECTOR
OPTION (CODE B5H)
4.92
(125.0) SOLENOID "b" SOLENOID "a"
7 LBS.-FT. TORQUE
1/2 -14 NPTF BOTH SIDES FOR SOLENOID NUT
MANUAL OVERIDE PIN
DIN CONNECTOR
(CODE D) BLACK PLUG GREY PLUG (SOLENOID ENDS ONLY)
3.89
(98.8) 3.25
3.18
(80.8) 4.31 (82.6)
1.25 (4) (109.4)
(31.8)
SOLENOID "b" SOLENOID "a"
"A" PORT END "B" PORT END
3.56 2.69
(90.4) (68.3)
11.63
(295.4)
16.63
(422.4)
NOTES:
1. Electrical box may be rotated 180° (Codes B, BT, and B5H).
2. 5-pin disconnect meets NFPA recommende standard T3.5.29 R1 - 2003.
3. Two (2) lead wires for each solenoid 6 inches (152.4 mm) long (except
Code D) and ground screw are provided by removing the top cover plate.
4. Four (4) mounting bolts are torqued to 10 - 12 lbs.-Ft. (13.5 - 16.3 Nm).
SCHEMATICS
Code 3 Code 5
A B A B
LVDT LVDT
P T P T
25
ED05M
Proportional Directional Control Valves
DIRECT OPERATED WITH LVDT
ED05M G L C
MECHANICAL OPTIONS
CODE DESCRIPTION
LVDT ON
L
“A” PORT END
REVERSE ASSEMBLY
LR LVDT ON
“B” PORT END
26
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
Meter-in spools (code "I") meter oil into the actuator. These VOLTAGE Code 12 12 VDC
spools are commonly used in applications where the (Nominal) Code 24 24 VDC
actuator is always working against a positive (resistive) CURRENT Code 12 2.2 Amp
load. Meter-in spools can also be used with a pressure (Maximum) Code 24 1.1 Amp
compensated module.
WATTAGE (I2 R) Code 12 19
Meter-out spools (code "O") meter flow out of the actuator. @ 76° F. (24° C.) Code 24 19
These spools are commonly used in applications with "run (Continuous)
away" loads such as over-center loads. Meter-out spools COIL
are also used with high ratio cylinders. Code 12 3.8 Ohms
RESISTANCE Code 24 15.2 Ohms
@ 68° F. (20° C.)
It is important to properly size a proportional valve to
achieve good resolution. A common mistake when Continuous @ rated
specifying proportional valves is selecting too high a rated operating with
DUTY CYCLE 120° F. (49° C.) fluid
flow. The result may be poor control of the actuator, and 100° F. (38° C.)
particularly with respect to velocity and resolution. Ideal ambient temperature
valve size is usually one that provides just enough
maximum flow capability to achieve the desired velocity. WEIGHT Code 3 32 lbs. 14.5 kg
Code 5 31 lbs. 14.0 kg
Consult with Continental about special metering
characteristics: unequal-metering, step metering, other *NOTE: Data taken with fluid temperature at 120°F. (49°C.) and viscosity
nominal flows and other spool configurations. at 100 SUS (20.6 Cs), inlet pressure @ 1000 psi (69 bar) using
Continental Hydraulics ECM4 electronic controller.
Use caution when applying a separate internally-drained **NOTE: Response times are effected by pressure, viscosity and flow rate.
† NOTE: Drain port (Y) must be connected solely to tank below fluid level.
pressure control valve between the actuator and the
Back pressure or flucuation of pressures in the drain line may
proportional valve. Back pressure created by meter-out or reflect on controlled pressure in the pilot valve and thus the flow
combination metering proportional valves can add to the output of the main valve.
spring load of the pressure control valve, resulting in a
change of the control pressure level.
27
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
400
24 350
20 300
250
16
200
12 RATING
150
8
100
4
50
0 0
gpm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
lpm 0 40 80 120 160 200 240 280 320 360 400440 480 520 560 600 640
FLOW
POSITION
POSITION
“A” “B”
CROSS-
CROSS-
CENTER
OVER
2 210
FLOW
FLOW
END END
A B
A C Spool 0 180
Combination
Metering
P T
A B -2 150
Combination
Metering
-4 120
P T
TESTED WITH CHD
-6 AMPLIFIER 90
ECM4-L4-P1T1-C
1000PSI @ RATED
FLOW WITH SPOOL
-8 FULLY SHIFTED 60
OIL: 150 VG 32 @
+120° F.
-10 30
-12 0
.5 1 2 3 4 5 6 8 10 15 20
FREQUENCY RESPONSE (HZ)
28
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
lpm gpm
600 150 475 psid (33 bar)
500 125 325 psid (22 bar)
400 250 psid (17 bar)
FLOW
100
300 75 145 psid (10 bar)
200 72 psid (5 bar)
50
100 25
0 0
0 20 40 60 80 100
INPUT SIGNAL (%)
A1C and F1C Spools
Rated @ 46 gpm (175 lpm)
lpm gpm
175
600 150
500 125
400
FLOW
120 30
145 psid (10 bar)
80 20 72 psid (5 bar)
40 10
0 0
0 20 40 60 80 100
INPUT SIGNAL (%)
29
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
lpm gpm
120 600 psid (41 bar)
30
100 25 400 psid (27 bar)
80 20 250 psid (17 bar)
FLOW
60 15
145 psid (10 bar)
40 10
72 psid (5 bar)
20 5
0 0
0 20 40 60 80 100
INPUT SIGNAL (%)
A40C Spool
Rated @ 38 gpm (145 lpm)
lpm gpm
240
60 350 psid (24 bar)
200 250 psid (17 bar)
50
160 40 145 psid (10 bar)
FLOW
120 30
72 psid (5 bar)
80 20
40 10
0 0
0 20 40 60 80 100
INPUT SIGNAL (%)
30
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
5.57
(141.5)
2.11
1.53 (53.6)
(39.0)
2.25
A A (57.2)
.25 (6.4) DIA. PIN (2) 2.00
(50.8) 4.50
(114.3)
10.34
(262.6) CODE 5-R
10.34
(262.6) CODE 5
15.00
(381.0) CODE 3
VIEW A - A
SCHEMATICS
Code 3 Code 5 Code 5-R
A B A B A B
P T P T P T
31
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
ELECTRICAL
BOX MAY BE
Codes B and BT Codes B5H ROTATED 180°
1/2-14 NPT
ELECTRICAL A SOLENOID
CONNECTION
25 LBS.-FT.
MAX. TORQUE 7.08
(179.8)
7.82
(198.6)
32
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
ELECTRICAL
BOX MAY BE
Codes B and BT Codes B5H ROTATED 180°
1/2-14 NPT
ELECTRICAL A SOLENOID
CONNECTION
25 LBS.-FT.
MAX. TORQUE 7.08
(179.8)
7.82
(198.6)
32
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITHOUT LVDT
ED08M G L C
33
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITH LVDT
POSITION
POSITION
POSITION
“A” “B”
CROSS-
CROSS-
FULL LOOP: P A B T or P B A T
CENTER
PORT PORT
OVER
OVER
FLOW
FLOW
END END
A3C A2C A1C
bar psid F3C F2C A40C F1C A B
40 A C Spool
550 AC Combination
36 FC Metering
500
P T
32
450 A B
PRESSURE DROP
28 400
F C Spool
Combination
Metering
24 350
P T
20 300
250
16
200
12 RATING
150
8
100
4 50
0 0
gpm 0 10 20 30 40 50 60 70 80 90 100 120 140 160
lpm 0 40 80 120 160 200 240 280 360 440 480 520 560
FLOW
AMPLITUDE RATIO
0 180
AMPLITUDE RATIO (dB)
-2 150
-12 0
.2 .3 .4 .5 1.0 2
3 4 5 10 20 30 40 50 60
FREQUENCY (HZ)
35
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITH LVDT
lpm gpm
600 150 475 psid (33 bar)
500 125 325 psid (22 bar)
400 250 psid (17 bar)
FLOW
100
300 75 145 psid (10 bar)
200 72 psid (5 bar)
50
100 25
0 0
0 20 40 60 80 100
INPUT SIGNAL (%)
A1C and F1C Spools
Rated @ 46 gpm (175 lpm)
lpm gpm
175
600 150
500 125
FLOW
0 0
0 20 40 60 80 100
lpm gpm
120 600 psid (41 bar)
30
100 25 400 psid (27 bar)
80 20
FLOW
A40C Spool
Rated @ 38 gpm (145 lpm)
lpm gpm
240
60 350 psid (24 bar)
200
50 250 psid (17 bar)
160
40
FLOW
37
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITH LVDT
5.57
(141.5)
2.11
1.53 (53.6)
(39.0)
2.25
A A (57.2)
.25 (6.4) DIA. PIN (2) 2.00
(50.8) 4.50
(114.3)
10.34
(262.6) CODE 5-R
10.34
(262.6) CODE 5
15.00
(381.0) CODE 3
SCHEMATICS
Code 3 Code 5 Code 5-R
A B A B A B
LVDT LVDT
LVDT
P T P T P T
38
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITH LVDT
ELECTRICAL
BOX MAY BE
Codes B and BT Codes B5H ROTATED 180°
1/2-14 NPT
ELECTRICAL A SOLENOID
CONNECTION
25 LBS.-FT. 7.82
MAX. TORQUE (198.6)
7.08
(179.8)
39
ED08M
Proportional Directional Control Valves
PILOT OPERATED WITH LVDT
ED08M G L C
40
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
The Continental Hydraulics EF10C is a direct operated, flow THRESHOLD With Dither < 3%
control cartridge valve that exhibits pressure compensation
characteristics. This valve is available for use in existing or REPEATABILITY With Dither < 3%
new applications using meter in, meter out, bleed-off 16% nominal
DEADBAND
priority/bypass control circuit configurations. of spool travel
41
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
Code D16
38 10 38 10
500 psid (34 bar)
30 8 30 8 500 psid (34 bar)
FLOW
FLOW
300 psid (20.4 bar)
23 6 23 6
145 psid (10 bar) 145 psid (10 bar)
15 4 15 4
72 psid (5 bar)
72 psid (5 bar)
7.6 2 7.6 2
0 0 0 0
0 25 50 75 100 0 25 50 75 100
INPUT SIGNAL (%) INPUT SIGNAL (%)
Code D28
38 10 38 10
500 psid (34 bar)
30 8 30 8 500 psid (34 bar)
FLOW
0 0 0 0
0 25 50 75 100 0 25 50 75 100
INPUT SIGNAL (%) INPUT SIGNAL (%)
42
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
Code D16
RATED CURRENT
RATED CURRENT
38 10 38 10
100%
85%
30 8 30 8
FLOW
FLOW
85%
75%
23 6 23 6 75%
64% 64%
15 4 15 4
50% 50%
7.6 2 40% 7.6 2 40%
0 0 0 0
psi 0 500 1000 1500 2000 2500 3000 psi 0 500 1000 1500 2000 2500 3000
bar 0 34 69 103 138 172 207 bar 0 34 69 103 138 172 207
PRESSURE DROP PRESSURE DROP
Code D28
57 15 57 15
100%
RATED CURRENT
RATED CURRENT
45 12 45 12
85% 100%
FLOW
FLOW
9 9 85%
34 34
75%
75%
23 6 64% 23 6
64%
11 3 50% 11 3 50%
40% 40%
0 0 0 0
psi 0 500 1000 1500 2000 2500 3000 psi 0 500 1000 1500 2000 2500 3000
bar 0 34 69 103 138 172 207 bar 0 34 69 103 138 172 207
PRESSURE DROP PRESSURE DROP
43
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
AMPLITUDE RATIO
2
1
0
AMPLITUDE RATIO (dB)
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
0.1 1 10 100
FREQUENCY (Hz)
PHASE LAG
180
150
PHASE LAG (Degrees)
120
90
60
30
0
0.1 1 10 100
FREQUENCY (Hz)
44
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
2.74
(69.5)
3.60
(91.4)
.562
(14.27)Ø
MAX.
.947 .810 .688 .625
1.188 .943 Ø .814 Ø .690 Ø .627 Ø
(30.17)Ø (24.05)Ø (20.57)Ø (17.47)Ø (15.87)Ø
(23.95 (20.67 (17.53) (15.92)
63 63
PORT #1
15° 100
.062
.005 (1.57)R.
45° .010 R.
(1.27) R.
7/8-14UNF-2B (.254)
29°
45
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
PORT #3
1.25
3.00 (31.8)
(76.2)
2.24
(56.9) .50 .63
(13.0) (15.9)
3.97
(100.8)
1.25 PORT #1
(31.8) 2.50
(63.5)
2.00
(50.8)
1.67 .28
(42.4) (7.1) DIA.
7.25
(184.2)
PORT #2
EF10C SCHEMATIC
46
EF10C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
EF10 D G D L B
SOLENOID
CODE VOLTAGE
12 12 VDC
24 24 VDC
FUNCTION SEALS ELECTRICAL
CODE CODE CODE
DIRECT VITON DIN 43650
OPERATED SEALS CONNECTOR
STANDARD STANDARD STANDARD
47
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
The Continental Hydraulics EF12C is a direct operated, flow THRESHOLD With Dither < 5%
control cartridge valve that exhibits pressure compensation
characteristics. This valve is available for use in existing or REPEATABILITY With Dither < 3%
new applications using meter in, meter out, bleed-off 16% nominal
DEADBAND
priority/bypass control circuit configurations. of spool travel
48
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
Code D40
FLOW
300 psid (20.4 bar) 500 psid (34 bar)
57 15 57 15 300 psid (20.4 bar)
145 psid (10 bar) 145 psid (10 bar)
38 10 38 10
72 psid (5 bar) 72 psid (5 bar)
19 5 19 5
0 0 0 0
0 25 50 75 100 0 25 50 75 100
INPUT SIGNAL (%) INPUT SIGNAL (%)
Code D60
114 30 1000 psid (69 bar) 114 30 1000 psid (69 bar)
FLOW
19 5 19 5
0 0 0 0
0 25 50 75 100 0 25 50 75 100
INPUT SIGNAL (%) INPUT SIGNAL (%)
49
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
Code D40
RATED CURRENT
RATED CURRENT
75%
76 20 45 12 100%
FLOW
FLOW
57 15 64% 9
34 75%
50% 64%
38 10 23 6
50%
19 5 40% 11 3
40%
0 0 25% 0 0 25%
psi 0 500 1000 1500 2000 2500 3000 psi 0 500 1000 1500 2000 2500 3000
bar 0 34 69 103 138 172 207 bar 0 34 69 103 138 172 207
PRESSURE DROP PRESSURE DROP
Code D60
RATED CURRENT
RATED CURRENT
95 25 76 20
75%
FLOW
100%
76 20 57 15
FLOW
75%
57 15 50% 38 10
50%
38 10 40% 19 5 40%
25%
19 5 0 0
25% psi 0 500 1000 1500 2000 2500 3000
0 0
psi 0 500 1000 1500 2000 2500 3000 bar 0 34 69 103 138 172 207
PRESSURE DROP
bar 0 34 69 103 138 172 207
PRESSURE DROP
50
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
AMPLITUDE RATIO
2
1
0
AMPLITUDE RATIO (dB)
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
0.1 1 10 100
FREQUENCY (Hz)
PHASE LAG
180
150
PHASE LAG (Degrees)
120
90
60
30
0
0.1 1 10 100
FREQUENCY (Hz)
51
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
7.18
(182.37)
4.292
(109.02)
3.902
(99.11)
2.735
(69.47)
3.597
(91.36)
PORT #3
45° .500 Ø
(12.70)
15° 100
PORT #2
.500 Ø
.005 (12.70)
.062 R.
.010 R. (1.57) 29°
1-1/16-12UN-2B (1.27)R. 2.090
(.254) (53.09) REF.
52
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
PORT #3
1.75
(44.4)
4.00
(101.6) (221.75
2.85 .2)
.75
(72.4) (19.1)
2.00
(50.8) 4.00
(101.6)
4.74
(120.4)
3.62
(91.9)
1.88 .34
(47.8) (8.6) DIA.
8.26 PORT #1
(209.8)
PORT #2
EF12C SCHEMATIC
3
53
EF12C
Proportional Cartridge Valves
DIRECT OPERATED FLOW CONTROL
EF12 D G D L B
SOLENOID
CODE VOLTAGE
12 12 VDC
24 24 VDC
FUNCTION SEALS ELECTRICAL
CODE CODE CODE
DIRECT VITON DIN 43650
OPERATED SEALS CONNECTOR
STANDARD STANDARD STANDARD
54
EP03M-3
Pressure Control Valves
PRESSURE REDUCING/RELIEVING, SUBPLATE MOUNTED
MOUNTING Unrestricted
POSITION (Horizontal preferred)
The single solenoid version, code B, will allow fluid WATTAGE (I2 R) Code 12 19
flow from P port to B port when an electrical signal is @ 68° F. (20° C.) Code 24 19
(Continuous)
applied. If the signal is decreased to zero, P port will
be blocked and B port opened to the tank port. The COIL Code 12 3.8 Ohms
code A version will allow flow from P to A. RESISTANCE Code 24 15.2 Ohms
@ 68° F. (20° C.)
The double solenoid version, code C, will allow flow
INTERNAL 8 in.3/min. typical
from P to A (or P to B) when the signal is applied to LEAKAGE @ 1000 psi (69 bar) ΔP (131.1 ml/min.)
the proper solenoid. A and B ports are used @ 0 VDC
alternately for pressure reduction in the respective Max. 150° F. (65° C.)
FLUID
port. P and T ports are common. TEMPERATURE For safety, over
RANGE 130° F. (54° C.)
is not recommended
*NOTE: Data taken with fluid temperature at 120°F. (49°C.) and viscosity
at 100 SUS (20.6 Cs), using Continental Hydraulics ECM4
electronic controller.
55
EP03M-3
Pressure Control Valves
PRESSURE REDUCING/RELIEVING, SUBPLATE MOUNTED
PRESSURE VS. FLOW CURVES NOTE: When the secondary pressure exceeds the
reduced set pressure, flow reversal will
occur and flow will take place from the
Code 15 controlled port to the tank port.
25
A OR B T (RELIEVING) P A OR B (REDUCING)
20 300
OUTLET PRESSURE P
15
200 Data taken with fluid temperature at 120°F. (49°C.)
and viscosity at 100 SUS (20.6 Cs), system
10 pressure @ 1500 psi (103 bar) using
100 Continental Hydraulics ECM4 electronic controller.
5
0 0
gpm 4 3 2 1 0 1 2 3 4 5
lpm 15 10 5 0 5 10 15 19
FLOW
Code 100
Control Pressure Range - 72 to 1450 psi (5 to 100 bar)
bar psi
2000
A OR B
100 1500
OUTLET PRESSURE P
0 0
gpm 4 3 2 1 0 1 2 3 4 5
lpm 15 10 5 0 5 10 15 19
FLOW
Code 225
Control Pressure Range - 290 to 3265 psi (20 to 225 bar)
bar psi
4000
A OR B
200 3000
OUTLET PRESSURE P
0 0
gpm 4 3 2 1 0 1 2 3 4 5
lpm 15 10 5 0 5 10 15 19
FLOW
56
EP03M-3
Pressure Control Valves
PRESSURE REDUCING/RELIEVING, SUBPLATE MOUNTED
bar psid
500
30
400
25 P A or P B
SPOOL FULLY
PRESSURE DROP
SHIFTED
20 300
A or B T
SPOOL SHIFTED TO
15 CONTROLLED
200
PRESSURE ON
10 P A or P B
PORT
100
5
0 0
0 1 2 3 4 5 6 7 8 9 gpm
0 5 10 15 20 25 30 lpm
FLOW
80
CONTROL PRESSURE IN %
60
40
20
0
0 10 20 30 40 50 60 70 80 90 100
57
EP03M-3
Pressure Control Valves
PRESSURE REDUCING/RELIEVING, SUBPLATE MOUNTED
10 LBS.-FT. TORQUE
FOR SOLENOID NUT
DIN CONNECTOR
(CODE D) BLACK PLUG GREY PLUG MANUAL OVERIDE PIN
3.36
.65 (85.3)
(16.5) 2.94
(74.7) 1.81
(46.0)
EP03M-3 SCHEMATICS
Code A Code B Code C
A B A B
T P P T P T
58
EP03M-3
Pressure Control Valves
PRESSURE REDUCING/RELIEVING, SUBPLATE MOUNTED
EP03M - 3 - G L B
PRESSURE RANGE
PRESSURE MAXIMUM
CODE
RANGE FLOW
2 - 15 bar 4.0 gpm
15
(29 - 217 psi) (15 lpm)
5 - 100 bar 4.0 gpm
100
(72 - 1450 psi) (15 lpm)
20 - 225 bar 3.1 gpm
225
(290 - 3265 psi) (12 lpm)
59
ELECTRO-HYDRAULIC PRODUCTS
Valve Accessories
VALVES
ACCESSORIES
60
P03MSV-RCC
Valve Accessories
PRESSURE CONTROL VALVES
MAXIMUM
OPERATING 3500 psi 241 bar
PRESSURE
COMPENSATION PRESSURE
60- 400 psi 4.1 - 27.6 bar
ADJUSTMENT RANGE
*NOTE: Data taken with fluid temperature at 120°F. (49°C.) and viscosity
at 100 SUS (20.6 Cs), using Continental Hydraulics ECM4
electronic controller.
DESCRIPTION
These pressure compensator valves are used to PLEASE NOTE: For other mounting sizes, consult
create a consistent pressure differential between the the factory for availability.
inlet and the outlet of an orifice. The most commonly
used in Electro-hydraulic circuits are the restrictive
and by-pass types. Care must be taken when
appling these components for they naturally will have
inconsistent pressure drops at various flow rates
through a given valve. However, they will improve
the system performance when widely changing loads
are seen. See flow curve charts.
Continental Hydraulics offers adjustable pressure
compensators to help match the valve to a circuit. To
adjust this valve, it is recommended that the
proportional valve be shifted to approximately 100%
shift. Then, adjust the compensator to achieve the
desired flow.
SCHEMATICS
Restrictive By-Pass
A1 P1 T1 B1 A1 P1 T1 B1
A P T B A P T B
61
P03MSV-RCC
Valve Accessories
PRESSURE CONTROL VALVES
lpm gpm
30 8
7
25 400 psid
6 300 psid
20
5
200 psid
FLOW
15 4 145 psid
3
10 60 psid
5
1
0 0
psid 0 500 1000 1500 2000 2500 3000 3500
PRESSURE DIFFERENTIAL
62
P03MSV-RCC
Valve Accessories
PRESSURE CONTROL VALVES
P03MSV-RCC DIMENSIONS
1.48
(37.6)
.70
(17.8)
PR
SV 2.00
(50.8) SAVAGE, MN 55378
*XXXXXX*
(36.1)
(26.7)
.13
(3.2)
63
P03MSV-RCC
Valve Accessories
PRESSURE CONTROL VALVES
P03MSV - A B
64
ELECTRO-HYDRAULIC PRODUCTS
Electronic Control Boards
ELECTRONIC
CONTROL
BOARDS
65
ECM4, ECM5
Electronic Control Boards
SELECTION CHART
(Single Solenoid
ECM5-R2
ECMP-L1
ECM4-R2
ECM5-L2
ECM4-L4
ECM4-L2
ECM4-L1
Only)
VALVE MODEL
VED03M w/o OB
1 or 2 SOLENOIDS
VED03M w/ OB
1 or 2 SOLENOIDS
EF10C, EF12C
EP03M-3
66
ECMP-L1
Power Plug
PROPORTIONAL DIRECTIONAL CONTROL VALVE OPTION
GENERAL SPECIFICATIONS
SUPPLY 11.5 VDC Min.
VOLTAGE 32.0 VDC Max.
SUPPLY
45 mA Max. (No Load)
CURRENT
0 - 10 VDC
Voltage
(500 k ohms)
0 - 20 mA
Current
(100 W ohms shunt resistor)
Regulation ΔV ± 0.2% / V
INPUT
CONTROL
Regulation ΔT ± 0.1% / C°
SIGNAL
0.1 - 20 sec. Linear
Ramp Time (Up/Down)
(± 0.1% / C°)
-13° F. to 185° F.
GENERAL DESCRIPTION TEMPERATURE RANGE
-25° C. to 85° C.
The Electronic Power Plug is a compact electronic Continuous 3.0 A Max.
circuit built into an environment-resistant miniaturized OUTPUT
enclosure. The circuit features control of proportional CURRENT Peak Pulsed (16 ms) 17.0 A Max.
solenoids and operators. Functions include minimum @ 25° C.
(77° F.) I Minimum (± 20%) 0 - 1.0 A Max.
and maximum current limiting, control signals from 0 -
10 V or 0 - 20mA (with a step function at 0.2 volts or I Maximum (± 20%) I Min. + 2.0 mA Max.
0.4mA included for minimum current), a 0.10 - 20
second linear ramp up/ramp down adjustment and
output current proportional to input command signal. Minimum Current Adjustment - Set both minimum and
maximum current controls maximum
This unit incorporates the Form "A" DIN 43650/ISO
counterclockwise. Apply an input command signal of
4400 connector male and female interface. The unit
approximaiely 0.5 volts or 1.0 mA. Adjust the
is mounted by use of a single mounting screw, DIN
minimum current control for a minimum current or to
connector and two gaskets. Built to meet NEMA 4
a desired system response. Back up adjustment until
environment standards, the Power Plug is made from
system stops responding. Proceed to maximum
engineered polymers for resistance to harsh
current control.
chemicals and ingress of water or foreign substances.
Adjustments are made on the top surface of the unit. Maximum Current Adjustment - Increase the input
command signal to 10 volts or 20 mA. Adjust
FUNCTION maximum current control for a maximum current limit
Minimum Current and Maximum Current - These two or to a desired system response.
adjustments will vary the minimum and maximum
output current limits. The minimum current can be
set between 0 -1.0 A for 3.0 A version. The maximum
current can be set in the range between the minimum
current setting and the minimum current setting plus
2.0 A. The minimum current must be set first as
described below.
67
ECMP-L1
Power Plug
PROPORTIONAL DIRECTIONAL CONTROL VALVE OPTION
Note: To minimize any effect of supply voltage, load values satisfy the equality stated above.
resistance or temperature variation, make setup
The graph below depicts Load Current vs. Supply
adjustments when these parameters are at the
Voltage for various load resistances. Use this graph
midpoint of the expected operating range for a
to aid in determining supply voltage requirements
particlular installation. For example, if the expected
versus load current for the resistance of the device
operating temperature range is 20º C. to 60º C.,
being controlled. For example, if the required load
make final setup adjustments when system is
current is 1 amp and the load resistance is 25 ohms,
approximately 40º C. If the supply voltage has a
then the minimum required supply voltage is 25 volts.
tolerance of 22 to 32 volts, make adjustments when
Alternately, if the load resistance is only 15 ohms,
the supply voltage is approximately 27 VDC.
then the minimum required supply voltage is 15 volts.
Ramp Up/Ramp Down - Adjust to desired ramp The load resistance line must fall within the area
up/ramp down time (0.10 - 20 seconds). Ramp time below the maximum required load current and to the
is linear and is proportional to the step change in the left of the minimum supply voltage. In determining
control signal. For example, maximum resistance, changes due to temperature
must be taken into consideration. The Power Plug
0.2 - 10 VDC change in control signal gives maximum
will limit the output current to the 3.0 amp design limit.
ramp of 20 seconds.
0.2 - 5 VDC change in control signal gives maximum Load Resistance
(Ohms)
ramp of 10 seconds. 15
25
PWM Frequency - The output is pulse-width
35
modulated to control output current within the 45
minimum and maximum current settings. The 55
frequency of the modulation is continuously 2.5
adjustable from 95 - 225 Hz (Standard. Other ranges
available).
2.0
Load Current (Amps)
68
ECMP-L1
Power Plug
PROPORTIONAL DIRECTIONAL CONTROL VALVE OPTION
STATUS STATUS
POWER OUTPUT POWER OUTPUT
I Min I Min
I Max I Max
Ramp Up Ramp Up
CONTROL + CONTROL
VOLTAGE 3 CURRENT 3
0 - 10 VDC – 0 - 20 mA
2 1 2 1 + –
4 4 +
SUPPLY
SUPPLY – VOLTAGE
VOLTAGE – 12 - 30 VDC
12 - 30 VDC +
STATUS
POWER OUTPUT
I Min
I Max
3.05
(77.5)
Ramp Up
Ramp Down
PWM Freq
ECMP-L1-00-CC-A
3.76
(95.5)
SAVAGE, MN 55378
FORM "A"
DIN 43650/
ISO 4400
69
ECMP-L1
Power Plug
PROPORTIONAL DIRECTIONAL CONTROL VALVE OPTION
DESIGN
LETTER
ECMP - L1 - 0 0 CC A
OPTIONS MOUNTING
CODE DESCRIPTION CODE DESCRIPTION
0 NO CORD SET CONTROL VOLTAGE
AND CURRENT
0 INPUT (NO
REFERENCE
VOLTAGE OUTPUT)
70
ECM4-L1
Electronic Control Boards
LINEAR AMPLIFIER - SINGLE SOLENOID
71
ECM4-L1
Electronic Control Boards
LINEAR AMPLIFIER - SINGLE SOLENOID
FUNCTIONAL SCHEMATIC
+ DC PWR OWER
P +5V AUXILIARY
POWER VOLTAGE 5 OUTPUT
DC POWER 3 PROTECTION
SUPPLY REGULATOR +5 VOLTS DC
PWR GND
10-30 VDC 4
COMMAND
INPUT 6 COMMAND
INTERNAL
0-10 VDC, 0-5 VDC + VOLTAGE
4-20 ma, 0-20 ma CMD REGULATOR
INPUT +
P4
CMD AMP
-
P2 PPOWER
ON LED
ON LED
GAIN/
GAIN/
OFFSET
OUTPUT TEST POINT
P5
IOUT
PWM TEST POINT
PWM
PWM PWM CURRENT OUT
RAMP OSC
OS C DRIVE SENSE 1
ACCEL/DECEL
A AND LIMIT
TEST POINT
TP
GND
RAMP RAMP MODE SELECT
.015
015-1.5
. -SEC.
1.5 SEC. GND
2
.3. - 30 SEC.
3-30SEC. GAIN ANDAND
GAIN P7
NULL ADJ.ADJ.
NULL
P8 P9
GAI N
GAIN
LIMIT
LIMIT AMP
AMP
72
ECM4-L1
Electronic Control Boards
LINEAR AMPLIFIER - SINGLE SOLENOID
ECM4-L1-P12P-C-A
Q1
+ +
PWR ON
D13
U5 U6 ENABLED
D14
P1 OUTPUT
1 1 PWM Q2 Q3 TEST
3.94
POINT
2 2 (100.1)
3 3 U1 NULL
GND
4 4 U2 U3 U7
5 5 GAIN
RAMP
3.50
(88.9)
6 6
J1J2 J1
7 7 J2
ACCEL
J3
8 8 J4 J1J2
J1J2 J5
DECEL
TEST
CMD U4 DITHER U8
J1J2
J1J2
P4 P3 P5 P2 P6 P7 P8 P9
73
ECM4-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
Code "E" mounts into a single EURO card cage. All Accel/Decel 30 - 3000 ms .30 - 30 sec.
adjustments, operating lights and test points are
OUTPUT Command
located on a face panel so that the board does not ± 2 VDC ±10 VDC/None
CONTROL Offset
require removal from the cage for set-up adjustments.
Enable Jumper Selected
CAUTION: Do not use radio transmitters or
similar devices that emit radio frequency (RF) Disable Jumper Selected
signals within three (3) feet (91.4 cm) of an
exposed amplifier board. If outer loop feedback Channels Dual
is used, consult the feedback device supplier for
possible RF interference.
ADJUSTMENTS
RAMP This adjustment will vary the rate of
NULL This adjustment, one for each solenoid, is increasing or decreasing the command signal. The
used to reduce or eliminate deadband. LEDs will controlled acceleration and deceleration for both
indicate which solenoid is being energized. forward and reverse will be the same for a specific
ramp control setting.
GAIN This adjustment, one for each solenoid, is
used to set maximum valve current when command OFFSET On-board command potentiometer for use
is at maximum. This will result in full command during set-up. It can also be used as a fine center
resolution from off to maximum valve output. adjustment.
74
ECM4-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
FUNCTIONAL SCHEMATIC
a/c
30
32 28
26
POWER + POWER
SUPPLY 24 PROTECTION B B
10 VDC MIN. 22 PWM CURRENT
30 VDC MAX. DRIVE SENSE
SOL. SOL. 20 PWM & LIMIT
A B CURRENT ± 15V +15V OSC
18
PROPORTIONAL LIMIT AND DC/DC TP-B
VALVE
16 PROTECTION CONVERT -15V DITHER
14 OSC IB
+15V +10V -10V -15V OFFSET
POT A
A/B GAIN A
DC POWER OUT PWM CURRENT
FOR COMMAND & NULL ADJ. SENSE
12 CMD DRIVE
& LIMIT
POTENTIOMETER RAMP
INPUT GAIN
ACEL/DECEL
8 AMP .03 - 3 SEC.
±10V IN 10 A B TP-A
.3 - 30 SEC.
±5V IN IA
REF. 6 NULL
(4 - 20 mA) TP SUM AMP
4 - 20 mA IN GND AND
LIMITER
SIGNAL 4 ENABLE CODE P: P3 - J1
GROUND JUMPER CODE E: P8 - J1
COMMAND INPUTS
+, -, ±10 VDC
±5 VDC ENABLE
4 to 20 mA 2 GND GO
OPEN STOP
a/c
TERMINAL 2 MUST
BE GROUNDED
TO MAKE BOARD
OPERATIONAL
75
ECM4-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
U7
GAIN
TP-A
D18
C46
D14
3.50
NULL
D15
D16
R112
(88.9) C6 R23 R44 J1 J2 R58 R71 R84 C44 C47
U4 4N32 R59 R72
D3 R45 R85 R94
D4 C20 R47 C24 C30 R73 R86 R95
GAIN
R33 R48 D11 C34 C36 C40 R96
+ +
R113
R34 D7 R60 R74 R87 R97
C8 C14 C25 R98
GND
TP-B
R99
LM339
D1 9
FR2
U5 U9 LMC6034 U11 LCM6482
R100
+ +
3.94 C9 C15
R101
NULL
(100.0) R35
R36
R49
R50 C26
R61
C31
R75
R76
C37
R88
C41 D17
R102
R114
R26 C19 C21 D8 R62 R77 C38 R103
C10 J1 J2 R37 D9 R63 R78 R89 R104
R27 R38 R51 R64 RAMP J1 J2 R105
RAMP
C11 P5 R39 R52 C27 C32 C33 P7 C42 R106
R115
R28 R40 R53 R65 R90 R107
R29 R41 R54 R66 R79 R91 R108
OFFSET
C16
U2
C17
R30
PWM
6.05
(153.7)
6.30
(160.0)
76
ECM4-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
ENA
BLE
SIG
GND
2
mA
R3
REF
10
R112
R113
12
4.83 +
R114
OUT
3.94
(100.0)
RF1
(122.7) 5
16 -10V
OUT
C42
+10V
+ + 18 OUT
TP2 D21
D26
R23
GND
R35 +DC
R9 PWR
R36
7
U10 1 T1
8
L1 R102 C39
C2 R103 A
C27 C31 30 OUT
RED D29
A-B
TP3
C44 C45
32 GND
Q1 + Q2 + D30
.46 6.30
(11.7) (160.0)
7.36
(186.9)
ENABLED
GROUND
ECM4-L2-P15E-C-C
5.05
A (128.3)
NULL
GAIN
TEST POINT
1 VOLT/AMP
B
NULL
GAIN
TEST POINT
1 VOLT/AMP
ECM4-L2-P15E-C
1.60
(40.6)
77
ECM4-L4
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
Coil temperature changes will not affect output Input Resistance 100 K nominal
current to the valve because it is a current control
FEEDBACK Position 4 to 20 mA - LVDT Optional
device. Also, it is current limited and protected against
short circuits. Coil return wires may be separate or Voltage 12 VDC 24 VDC
OUTPUT
combined. A pre-set dither improves valve POWER
characteristics over the full range of PWM output. Current 3.0 Amps Max. 2.0 Amps Max.
Command signals may be ±10 VDC bipolar, 0 to +5 PWM Frequency 1400 Hz. Nominal
VDC unipolar, or 4-20 ma current. For maximum Optional
.
performance, the amplifier is designed to work with Dither 120 HZ 0, 60, 90,
an optional LVDT position feedback sensor. OUTPUT 150,180 Hz.
CONTROL
This unit features a built-in DC to DC converter to Accel/Decel 15 - 1500 ms .15 - 15 sec.
provide reference voltages from DC input power
ranging from 10 to 30 volts. A limited amount of Command Dual
regulated DC is available to power sensors and
-40° F. to 176° F.
command controls. TEMPERATURE RANGE
-40° C. to 80° C.
In normal operation, the output ENABLE is connected
± 15 Volts DC @ 50 mA
to ground. The green OK LED will light. The board AUXILIARY OUTPUT
± 10 Volts DC @ 10 mA
can be enabled internally with jumper P2-J1 or
externally by grounding terminal P1-18. When the Terminal block -
18 pin, PC Mtd., .20 centers
ground connection is broken, both outputs are
(Phoenix Header
disabled immediately and the yellow DISABLE LED #MSTBA 1.5/18-G-5.08)
TERMINAL BLOCK
will light. When the ground connection is returned, Connector- 18 pin,
the selected output returns to the commanded value. Right Angle Plug-In
(Phoenix Terminal Block
Safety or panic stop designs should always include
#MSTB 1.5/18-ST-5.08)
redundant shut-off controls.
MOUNTING Panel
The LVDT spool position feedback uses a 4-20 ma
signal. Loss of feedback is sensed if the signal goes
below 2 ma or above 25 ma. This will disable outputs CAUTION: Do not use radio transmitters or
and light the red LVDT FAULT LED. similar devices that emit radio frequency (RF)
The ECM4 amplifier is packaged in a 9.20 by 6.30 signals within three (3) feet (91.4 cm) of an
inch (160.0 by 233.0 mm) printed circuit board. All exposed amplifier board. If outer loop feedback
connections are made via a terminal strip at one end. is used, consult the feedback device supplier for
The circuit board may be mounted with standoffs on a possible RF interference.
panel.
78
ECM4-L4
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
FUNCTIONAL SCHEMATIC
POWER
+DC POWER P1-4 PROTECTION P1-6 +15V
POWER GND P1-5 CURRENT P1-7 +10V AUXILIARY
DC/DC
CONVERT LIMIT AND POWER
CMD 10V P1-10 ACEL. DECL. PROTECTION P1-8 -10V SOURCE
CMD 5V P1-11 - P1-9 -15V
COMMAND CMD
INPUT INV.CMD P1-14 - CMD
- INPUT
AMP RAMP
INPUT ACCEL/DECEL
CMD P1-12 + AMP - .03 - 3 SEC.
.3 - 30 SEC.
A
RAMP A CURRENT
TEST POINT PWM
DRIVE
SENSE AND P1-1 SOL. A OUT
LIMIT
TP-A
OFFSET
CONTROL
OPEN LOOP
IA
TP-C
LOOP ERROR DIFF.
AMPLIFIER
FEEDBACK INV. FEEDBACK P1-16 - FDBK
INPUT
- FDBK
AMP AND
INTEGRATOR BI - A I
INPUT FEEDBACK P1-17 + AMP
AMP
TP-B
PWM
TEST IB
POINT B
PWM B
OSC. + PWM
CURRENT
SENSE AND
P1-3 SOL. B OUT
DRIVE LIMIT
OFFSET
CONTROL
A/B GAIN DITHER TP
AND NULL ADJ. OSC GND
GAIN
DITHER
TEST POINT
P1-2 SOL. A/B GND
SIGNAL GND P1-13 MODE SELECT
OK
(GREEN)
LVDT AMP
NULL AND
LVDT CUR. LIMIT
CENTER LVDT FAULT
LVDT DISABLE (RED)
LVDT LVDT
BUFFER FAULT
LVDT IN P1-15 SENSE
DISABLE
(YELLOW)
ENABLE
ENABLE P1-18 GND = GO
OPEN = STOP OR
79
ECM4-L4
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID W/3 WIRE /LVDT
.47
D1 U5
+
C38
+
C38
(11.9)
D2
C
R48
A C2
OUT 01 R49 L1 U L2
02 T1
D17
U12 TP-A
R163 R186 C101
R121 D18
R122 TP-B
+ +
C34 C39 C102
TP-C
C49
+ + GND
C35 C40
09 C6
PWM R127
4.13
10 (104.7)
GND
11
12 R
R
13
C7
14
15 C8
16
9.20
(233.0)
17
18
C16 C29
R1
FBK
R37 R67
R9 J2
RAMP
J3
R8 C30
J5
U17 J6
J7
J8
R1 J9
J10
J11
R15
J12
J13 4.13
R16 J14
J15
(104.7)
C1 J16
R17
U4 J17
R18 J18
A-CMD
TIME
FAULT D24
GAIN D28
OFFSET OUT
B A
FEEDBACK DECEL
B-OUT
TIME
D6 D13
R24
.82
(20.8)
.50
(12.7)
81
ECM4-R2
Electronic Control Boards
RAMP AMPLIFIER - DOUBLE SOLENOID
FUNCTIONAL SCHEMATIC
+5 VOLT
+ DC POWER 24 a,c POWER REGULATOR 20 a, c +5 VOLTS
SUPPLY PROTECTION AND DC
- DC POWER 22 a,c PROTECTION
SUPPLY 4c
SPEED 4 "A" OPTO-
INPUTS 4a ISOLATOR +15V
DC/DC
SPEED 4A CONVERTER -15V
6c ACEL DECL
SPEED 3 "A" OPTO- RAMP TP
INPUTS 6a ISOLATOR TEST TP-A GND
POINT
SPEED 3A RAMP A
ACEL/DECL CURRENT "A"
8c .01 - 1 SEC. SENSE AND 32 a, c
SPEED 2 "A" OPTO- SOLENOID
8a .3 - 30 SEC. FILTER
INPUTS ISOLATOR
.03 - 3 SEC. GROUND
SPEED 2A P4
10c
SPEED 1 "A" OPTO- A "A"
10a PWM 30 a, c SOLENOID
INPUTS ISOLATOR
SPEED 1A GAIN CONTROL DRIVE OUT
12c
SPEED 4 "B" OPTO-
INPUTS 12a ISOLATOR
SPEED 4B WARNING
FAULT (RED)
14c ACEL DECL LOGIC
SPEED 3 "B" OPTO- RAMP
14a TEST AND
INPUTS ISOLATOR THERMAL DISABLED
POINT
SPEED 3B RAMP OVERLOAD
LATCH (RED)
ACEL/DECL
16c .01 - 1 SEC.
SPEED 2 "B" OPTO-
INPUTS 16a ISOLATOR .3 - 30 SEC.
.03 - 3 SEC.
SPEED 2B P5
18c B "B"
SPEED 1 "B" OPTO- PWM 26 a, c
INPUTS 18a ISOLATOR SOLENOID
DRIVE
SPEED 1B GAIN CONTROL OUT
TP
ENABLE TP-B GND
ENABLE 2c ENABLE
INPUT GND = GO
OPEN = STOP B
CURRENT "B"
ENABLE 2a PWM 28 a, c SOLENOID
PWM TEST POINT SENSE AND
GROUND OSC FILTER GROUND
+
DITHER DITHER TEST POINT
OSC
82
ECM4-R2
Electronic Control Boards
RAMP AMPLIFIER - DOUBLE SOLENOID
ECM4-R2-P15E-24C-A DIMENSIONS
FEMALE MATING CONNECTOR
DIN 41612 - TYPE D
USE WITH BACK-PLANE
MODULE ECMA-BPD32-A
OR USE WITH SINGLE CARD
HOLDER ECMA-CHD32-A
.46 6.30
(11.7) (160.0)
7.36
(186.9)
1.60
(40.6) Inches
Dimensions shown in:
(millimeters)
A B
SPEED 1
SPEED 2
SPEED 3 5.05
(128.3)
SPEED 5 TYPICAL ORDERING CODE:
ACCEL
DECEL ECM4-R2-P15E-24C-A
GAIN
TEST POINT
1 VOLT/AMP
GROUND
WARNING DISABLED
83
ECM4-L4
Electronic Control Boards
DUAL CHANNEL AMPLIFIER
ECM4 - C
84
ECM5-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
85
ECM5-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
FUNCTIONAL SCHEMATIC
INPUT COMMAND
TB2 FUSE = 1A TB 1
1 + 5VDC H 117 VAC HOT
5K OHM
THIS 2 - 5VDC POWER G 117 VAC NEUTRAL
SUPPLY +15 VDC
8
- 15 VDC
±5 VDC
9 + 25 VDC E EARTH GROUND
F NO CONNECTION
OR +
C
DITHER CURRENT
DRIVER SOL. "b"
GND B -
3 RAMP NULL GAIN A
OTHER I I
COMMAND +V
THIS
SOURCES PULSE
±5 VDC -V -V
6 +V +V
WIDTH VALVE
T MODULATOR
-V I I I
+ D
CURRENT
A B A B DRIVER SOL. "a"
4 A - B
NOT USED 5
7
86
ECM5-L2
Electronic Control Boards
LINEAR AMPLIFIER - DOUBLE SOLENOID
+
C44
T2
R1 R2 R3 R4 R5 R103
U9 C49
ASSEMBLY 552150
A-PORT B-P0RT D13
+
C46
D1 D2 R88 C45
R6 R32 R47 D14
R33 D25
C2 RAMP C26 D15 R108
R34 C16
R9 R35 R50 R72 C37
C7 C27
S/N
+
U1 LF347 U5 LF347
C8 C28 C38
R36 R51
+
D7 R52 D12
6.88
MADE IN U.S.A.
(179.6) COMMON PWM R53
R54
C29
R73
C39
+
C19 R74
SAVAGE, MN.
C5 R37 R75
R14 R38 R76 C40
C9
+
C30
ECM5-L2-P1P-24C-B
U2 U6
D16
R15 R39 R57 R77
R16 J1 C10 R78 TP-A
R17 J2 R79
P2
R19 J4 DITHER COMMON C31 TP-B
R20 J5
6.25 D8 R58 C32 C41 C42
FAST ACTING
D21
1 AMP 250V
5 X 20 MM
R25 R42 R62 R86 D17 D22
R26 R43 R63 C35 C36
FUSE
R27 R44 R64 ˇINLET ˇ
R95 D23 MODULE
F
R29 C15 R66 R96
D24
D3 C23 L1 Q3
R97
D4 R45 R67 Q1
R68
TERM. B - NEUTRAL
R69
U8 LMC6482
U4
TERM. A - HOT
R70 D18
D5 R46 C24 L2 C50
AC LINE
+
D6 R71
R30 Q4 C43
COMMON
ENABLE
R31
CMD IN
+5 VDC
SOL B+
SOL A+
R100
-5 VDC
SOL B-
SOL A-
C6
R101
P1 Q2 D19
.31
(7.9) R102 A B
.25 6.25
(6.3) (158.7)
6.75
(171.4)
1.88
(47.8)
.75
(19.1)
87
ECM5-R2
Electronic Control Boards
RAMP AMPLIFIER - DOUBLE SOLENOID
88
ECM5-R2
Electronic Control Boards
RAMP AMPLIFIER - DOUBLE SOLENOID
FUNCTIONAL SCHEMATIC
TB1
C EARTH GROUND
B
SW3B SPEED 3 4 SPEED 3 ACCEL DECEL
B
COMMAND INPUT
3 COMMAND OUT
2 DEFEAT
89
ECM5-R2
Electronic Control Boards
RAMP AMPLIFIER - DOUBLE SOLENOID
B
A
14
13
11
10
2
9 Q1 Q2 U13
6
5
TERM. B - NEUTRAL
D16 D22
B+
A+
TERM. A - HOT
COMMON
COMMON
COMMON
SPD2
SPD3
SPD1
SPD2
SPD3
A-
P1
+10Vref
AC LINE
PORT A PORT B SOLENOIDS L1 + L2 + +
+
C2 C3 C4
PIM1
R142
1 AMP 250V
R98 R129
5 X 20 MM
D23
FUSE
U10
S/N
ASSEMBLY 552068
R145
D24
6.25
(158.7)
MADE IN U.S.A.
R147
CONTINENTAL HYDRAULICS
6.88
(174.8)
ECM5-R2-P12P-24C-B
SPD3
ACCL D31
SPD2 C1
+
SPD1 D32
SPEED
D33
TIME
0
TIME
SPEED
SPD1
R5 SPD2
SPD3
1.94 .38
(49.3) (9.5)
90
ECM5-R2
Electronic Control Boards
RAMP AMPLIFIER - DOUBLE SOLENOID
ECM5 - 24 C B
91
ELECTRO-HYDRAULIC PRODUCTS
Control Board Accessories
CONTROL
BOARD
ACCESSORIES
92
ECMA-P-24C
Electronic Control Boards
24 VOLT POWER SUPPLY
GENERAL SPECIFICATIONS
See AC Connection and
AC INPUT
Fusing Chart on next page.
LINE
±.05% for a 10% change
REGULATION
LOAD
±.05% for a 50% change
REGULATION
OUTPUT
. .02% PK-PK
RIPPLE
TRANSICENT
50µ seconds for 50% load change
RESPONSE
SHORT CIRCUIT
& OVERLOAD Automatic current limit/foldback
PROTECTION
• UL recognized SHOCK
Per Mil-Std-810B, Method 516,
Procedure 5
• CSA certified
REMOTE Capabilities included on remote sense
• Chassis notches for AC input PROGRAMMING models
Remote Sense
Remote sense terminals may be used to compensate losses may affect current limiting, AC line dropout
for output line losses and to provide for remote point point and OVP margin (if applicable).
of regulation. Figure 1 shows the proper termination
Leads should be sized to drop no more than 5.5 V -
for a power supply with remote sensing.
the less the better. Using a twisted pair or shielded
POINT OF REGULATION pair for the sense lines is recommended for noise
+ OUT immunity. In problem applications, using a small AC
RL
+ SENSE CO decoupling capacitor (.1 to 10 Fd) across the sense
- SENSE terminals is highly recommended. In some
- OUT
applications there may be a tendency for the power
supply to oscillate due to additional phase shift
Figure 1. caused by series resistance and inductance in the
Load lines must be sized to prevent an excessive load leads.
voltage drop from the output to the load. Since the
point of regulation is at the load, the power supply Continued Next Page...
must compensate for line losses. Excessive load line
93
ECMA-P-24C
Electronic Control Boards
24 VOLT POWER SUPPLY
Adding a capacitor Co will reduce output impedance Figure 2 shows an improved connection system in
and provide stability. The recommended value of Co which regulation is maintained at all three loads
is 100 Fd per ampere or 50 Fd per foot and can be because wire losses are not cumulative.
the sum of the distributed decoupling capacitors
found in most systems. + OUT
POWER SUPPLY has open sense lead protection GOOD + SENSE
GROUNDING 1 3
toprotect the load from an overvoltage condition if the - SENSE 2
sense leads are removed. There is no need to strap - OUT
the sense terminals to the output terminals in the
local sense mode. Figure 2.
94
ECMA-BPD32
Electronic Control Boards
BACK PLANE CONNECTOR
FEATURES
• Works with all ECM4 Euro style amplifiers.
• Use with card racks in single or multiple board
applications.
• Matches standard Eurocard rack dimensions.
• Foldback current limit
• Screw terminal wire attachment - no soldering.
FRONT
c a
2 2
A2
4 C2 4
A4
5.10 6 C4
(129.5) A6 6
8 C6 8
A8
10 C8 10
A10
12 C10
A12 12
14 C12 14
A14
16 C14 16
A16
4.82 18 C16
(122.4) A18
18
20 C18 20
A20
22 C20 22
A22
24 C22 24
A24
26 C24 26
A26
28 C26 28
A28
30 C28 30
A30
32 C30 32
A32 BACK
C32
EURO BACKPLANE MODULE CONTINENTAL HYDRAULICS
DIN 41612
TYPE D SAVAGE, MN 55378
.14
(3.6)
95
ECMA-CHD32
Electronic Control Boards
CARD HOLDER
FEATURES
• Works with all ECM4 Euro style amplifiers.
• Compatible with 100 by 160 mm (3.94” by
6.30”) cards.
• Screw terminal wire attachment - no soldering.
• Cards are retained with mechanical locks.
ECMA-CHD32 DIMENSIONS
Inches
Dimensions shown in:
(millimeters)
2.48
(63.0)
5.51
(140.0)
96
ECMA SERIES
Electronic Control Boards
OPTIONS
SELECT DESIGN
ONE LETTER
ECMA - A
OPTIONS
CODE DESCRIPTION
POWER SUPPLY
P-24C
24 VOLT - DC
BACK PLANE
CONNECTOR
BPD32
32 PIN - “D” SERIES
DIN - 41612
CARD HOLDER
CHD32 32 PIN - “D” SERIES
DIN - 41612
97
ELECTRO-HYDRAULIC PRODUCTS
Miscellaneous
MISCELLANEOUS
98
NFPA
Mounting Surfaces
DIMENSIONS: Mounting surfaces must be flat within 0.1 mm per NOTES: A = Cylinder Port B = Cylinder Port T = Tank Port
100 mm (.0004 in. per 4.00 in.) and N8 (63AA) finish. P = Pressure Port X = Pilot Port Y = Drain Port
M Min. A Min.
L B
K C
J D
H E
G F
G P(4) THD.
F T
E
C D B H
B
J
A A
MIN. K P
N L B
P MIN.
M A
O(4) DIA.
T MAX.
P(4) THREAD N Q DIA. x R DEEP
O DIA.
(4) MAX.
A MIN.
B
C
D
E
F INCH mm INCH mm INCH mm
G A 6.00 154.4 J 0.44 11.2 R 4.57 116.1
H B 5.13 130.3 K 0.69 17.5 S 1/2-13 UNC
J C 4.44 112.8 L 0.19 4.8 T 0.44 11.2
D 3.97 100.8 M 0.69 17.5 U 0.28 7.1
J K
L E 3.72 94.5 N 0.75 19.0 V 0.38 9.7
F 3.03 77.0 O 2.88 73.2 W 0.92 23.4
N M G 2.09 53.1 P 2.93 74.4
H 1.16 29.5 Q 3.63 92.2
Q O T P Y
R P
MIN. X A B
99
ELECTRO-HYDRAULIC PRODUCTS
TERMINOLOGY
TERMINOLOGY
Backlash. The free play between interacting mechanical Pressure Compensator. Devices used to create a
parts such as a lead screw. Occurs when motion is consistent pressure differential between the inlet and the
reversed. outlet of an orifice. The most commonly used in electro-
hydraulic circuits are the restrictive and by-pass types. Care
Compliance. The springiness of an object. Amount of must be taken when applying these components since they
displacement per unit of force. naturally will have inconsistent pressure drops at various
Deadband. The amount the spool must travel from the flow rates through a given valve. However, they will improve
center condition to the point that flow starts. Caused by the the system performance when widely changing loads are
overlap of the spool lands to the valve body lands. seen.
Dither. Used to reduce the effects of friction of the spool to Pressure Drop. In order to have flow, there must be
the body. A small amount of oscillating power added to the differential in pressure between two points. It will also
output power going to the valve coil. This signals rate require some amount of force (pressure) to push the fluid
and/or amplitude is adjustable so the effect will keep the through an orifice. A pressure drop, unlike in standard
spool in motion, but will not affect the output from the valve. hydraulic systems, is a “good thing” and is required.
Pressure drops create stiffness in the system, stiffness =
Flow Gain. Relationship of control flow to input current, controllability. Although pressure drop results in wasted
typically expressed as GPM/ma. energy through heat, it is the cost of getting in control.
Frequency Response. The measurement of how the Pressure Gain. A measure of the change in control port
output responds to an oscillating input signal of varying pressures as the input current is varied about the zero flow
frequency with fixed amplitude. Measured in terms of point.
decibels and/or phase lag. Decibels (dB) is given at the
–3dB point (the point at which the output is approximately Pulse Width Modulation (PWM). An effective method of
70% of the commanded output). Phase lag is given at the controlling electrical power without creating heat. PWM is
–90° point. Phase shift as compared to the input signal the amount or percent of time that power is ON for one
(the output is at 100% shift when the command is at 0%). cycle. If power is on for 25% and off for 75% of a cycle of a
12 volt supply, the average amount would be 3 volts. The
Gain (Current maximum). Sets maximum amperage to frequency must be significantly higher than the valve
the solenoid. Used to set the maximum flow or pressure response.
from the valve to the system. Do not adjust past the
maximum the system can supply or the system may not Ramp Accel. Limits the rate an increasing command can
respond as desired if long ramp times are used. open or increase the valve output.
Hysteresis. The difference in the input current to produce Ramp Decel. Limits the rate a decreasing command can
the same output when going from center to full shift and close or decrease the valve output.
back to center. Typically measured at 50% signal in both Repeatability. The ability to repeatedly return to the same
directions. output for the same input from the same direction.
Inertia. The property of an object that resists change in Resolution. The smallest amount of input that results in a
motion. The inertia of an object is dependent on the mass change in output.
and shape. Simply put, an object at rest tends to stay at
rest; an object in motion tends to stay in motion. Step Response. The amount of time it takes a spool to
shift for a stepped input signal.
Internal Leakage. There are two sources of internal
leakage. The first is the leakage between the main body Symmetry. The degree of equality between the flow gain
and spool and the second is pilot flow (some proportional of one direction and that of the reversed direction.
and servo components require a small pilot flow through a Threshold. The minimum change in reverse output with
hydraulic amplifier known as “quiescent flow”). the reversal of input signal. Percent of command change
Linearity. The maximum deviation of the control flow from required to show a change in output.
the best straight line of flow gain, expressed as a percent of
rated current.
Null Bias (Current minimum). Sets minimum amperage
to the solenoid. Used for deadband reduction, or will set a
minimum flow or pressure. Always adjust null before
adjusting gain.
100
ELECTRO-HYDRAULIC PRODUCTS
CONCEPTS
CONCEPTS
How Does a Direct Acting Proportional Flow • A smooth acceleration and deceleration is
Control Valve Work desired on the extend stroke.
There are three components or items that are Based on the above information, it will be assumed
required. First, a spool and body assembly that are that a counterbalance valve will be used to prevent
designed to gradually open or close a flow path the cylinder from free falling during the retract mode.
(metering notches or orifice) as it is moved along its A uniform acceleration and deceleration motion profile
distance of travel. The second component is a will be used.
proportional solenoid and spring arrangement that will
Typical Formula and Calculations Required
position the spool to a point, where the
1. Cylinder area for extend for a 2 inch bore =
electromagnetic force developed by the current
(2 x 2) x .7854 = 3.14 sq. in.
applied to the coil is balanced by the resistive force
2. Cylinder effective area for retract a 1 inch rod =
pushing back from the spring. The third component
3.14 - [(1 x 1) x .7854] = 2.36 sq. in.
that makes the proportional valve work is the
3. Average (extend mode) velocity for a uniform
amplifier card. An amplifier card is the component
acceleration and deceleration means that one-
that will convert a low power electrical command
half the time of the extend cycle will be
signal into a higher power controlled current to run
acceleration and half deceleration or .750
the solenoid.
seconds. Therefore, the maximum velocity =
System and Valve Sizing distance/time or 6 inches/.750 seconds = 8
In order to correctly “size” a valve for a given in./sec.
application, you MUST know the application. Start 8 Maximum Velocity
with the load itself and ask the following questions:
• What is the load? Is the load an over running 6
SPEED (in./sec.)
• How fast is the step response of the valve being DISTANCE (inches)
CONCEPTS (Continued...)
To show how time, flow or cylinder size affect each Pressure Drop and Flow Relationships
other in the above example: It must be understood that all proportional and servo
• Change the 1.5 second time to 1 second results control valves are orifices. With that stated, the
in 9.8 gpm and an additional 50 psi. relationship between pressure drop (the difference
• Drop the peak flow available to 3.5 gpm results
between the inlet pressure and the outlet pressure) is
in an increase of pressure at the cylinder as the
expressed by general formula for flow through an
load will need to be accelerated to its peak speed
orifice: Q = K(A) ΔP
quicker. This may result in damage to the product
being moved if the g forces are too great. Q = Flow
• Change the cylinder size will change both the K = Orifice Constant
flow rates and pressures required. A = Area
ΔP = Pressure Drop
Spool Selection
Selecting the correct spool is critical for best control An example of this would be a valve rated for passing
in any application. A valve sized incorrectly can be 10 gpm (37.8 lpm) at a pressure drop of 100 psi (6.9
the difference between correct consistent operation bar) will pass about 14 gpm (53.0 lpm) at a pressure
and poor overall control. Continental Hydraulics offers drop of 200 psi (13.8 bar). As you see if the load
not only a wide variety of flow rates, but also offers a required pressure changes or drops by 100 psi (6.9
variety of metering functions. These metering bar), the flow will automatically change by 40%. Care
functions are designed to match the load, actuator must be taken to watch how the load being controlled
and circuit characteristics for the best possible may change. If wide swings are possible, other
control. components may be required to compensate for the
effect.
When selecting a spool for given application, it is
recommended that the spool’s rated flow be as Open Loop Control Systems
closely matched to the maximum flow required. Size The system responds to a command input signal to
the spool for approximately a 200 - 300 pressure drop vary the output accordingly, but there will not be any
across the valve (see flow curve charts) for best corrections made to the output based on what is
overall performance. This pressure drop and/or back happening at the load.
pressure provide system stiffness that is required for Closed Loop Control Systems
optimum control. The system responds to the command input as in the
The metering characteristics of the spool will be open loop system, but the output will be corrected via
based on the load characteristics an/or circuit design. a comparison of the command input signal to a
Spool metering options available are combination negative feedback signal coming from a source at the
metering, meter-in, meter-out, 2:1 ratio, 1.3:1 ratio load.
and position control. An example of open and closed loops would be a car
The flow control range of a valve should be kept going from a flat surface to an incline without
within a 20:1 ratio for the best results. Do not expect adjusting the gas pedal (command input source). This
to have one valve control 0.5 gpm and 50 gpm is open loop. In closed loop, adding cruise control
accurately at either condition. (feedback input signal) will adjust the system output
closing the loop for the desired control. A true closed
Due to external factors like high oil or ambient
loop control system will sense the system output and
temperature, coil power losses may affect the
automatically correct any difference between the
maximum output from the valve used. In situations
desired system reaction and the actual system
where high temperatures may come into play, size
reaction.
the valve so the maximum flow is achieved prior to
the maximum rated current of the coil is used. Continued Next Page...
102
ELECTRO-HYDRAULIC PRODUCTS
CONCEPTS
CONCEPTS (Continued...)
Closed loop systems for hydraulic applications can be course using only the rear view mirror. You will not
defined by three methods. Each required a certain travel as fast (Proportional) towards the destination
type of logic to achieve the best performance. as by the time you see the road has curved (Phase
• Position Control Lag), you will need to correct your course. As you
• Velocity Control move along (Time), the curve will cause you to turn
• Force or Pressure Control the wheel more as you note that you are further off
target (your brain multiples the error by the time
The basic concept of position control is to move to a
involved (Integration). At some point you will have
point and stop. This requires a logic system that will
over compensated and you will go off target with the
in essence have a command source (analog) of one
opposite error, and the process will start over again.
polarity and value, and a feedback source that will be
You solve this by slowing down (Proportional) so the
the same in value but opposite in polarity. Once in
effectiveness of the corrections (Integration) are more
position, the two signals will cancel each other
substantial; or add a side view (a little Derivative) so
providing the control valve a zero or off command,
the corrections can be made quicker; or add a
and the valve will close. Digital systems will typically
forward view (a lot of Derivative) that will anticipate
be commanded to a position of X pulses, and once
the corrections based on your eyes seeing the
the system has counted out the correct number of
change allowing to start the corrections quicker as
pulses, it will send an off signal to the control valve.
they come up.
The concept of velocity control is to set an actuator
• Proportional Term - (moderate frequencies). As
speed and hold it constant. Unlike position control
the proportional term is increased, the
where the valve must close to hold position when the
effectiveness of Integration is lowered and the
loop error (position error) is zero, the valve in velocity
effectiveness of Derivative will come into effect
control must hold open when the loop error (velocity
later.
error) is zero to maintain desired velocity. The error,
between the feedback and command, is summed with • Integraton Term - (low frequencies, adds phase
the command resulting in an open valve. When the lag). The primary benefit is the reduction of
velocity error goes to zero, the output to the valve steady state error.
holds steady. Any further errors in velocity will adjust
• Derivative Term - (high frequencies, adds phase
output up or down to correct the loop.
lead). Helps improve responsiveness and
Force or pressure control is similar to velocity control. stability.
In pressure control, the valve must remain energized
Adjusting “PID”
(open) when the loop error (pressure error) is zero to
The adjustment procedure is to reduce the “I” and”D”
maintain desired pressure. The error, between the
term values to minimum so the “P” term value can be
feedback and command, is summed with the
set with little or no effect from the “I” and “D” terms.
command resulting in an energized valve. When the
Increase the “P” term until the system instability
pressure error goes to zero, the output to the valve
occurs. Set the “P” term about 30% less than that
holds steady. Any further errors in pressure will adjust
point. Next, raise the “I” term until the system is about
output up or down to correct the loop.
to go unstable, then increase “D” term to improve
These systems will also require other mathematical system stability. Repeat increasing “I” and then “D” as
calculations to help gain speed and accuracy. These needed.
calculations are done in the “P I D” loop closure part Rule of Thumb - Always select a feedback device
of the control circuit. that measures what you want to measure! An
example of this would be to use a load cell on the
• P Proportional
cylinder rather than a pressure transducer. A
• I Integration
pressure transducer is a device that does not take
• D Derivative
into account seal friction, mechanical friction, etc.
“PID” example: You need to move your vehicle from that will be subtracted from the actual force that is
point A to point B, down the road with several curves being exerted.
using only ”P” and “I”. On the first run, drive the
Continued Next Page...
103
ELECTRO-HYDRAULIC PRODUCTS
CONCEPTS
CONCEPTS (Continued...)
Formulas and Reference Material
• Current is measured in Amps (A)
• Voltage is measured in Volts (V)
• Resistance is measured in Ohms (O)
• Inductance is measured in Henries (H)
• Capacitance is measured in Farads (F)
Ohm’s Law: Voltage = Current x Resistance for DC
V=IxR
Power: Power (Watts) = Current x Voltage
W=IxV
Flow through an orifice: Q = K (A) ΔP (see
Pressure Drop and Flow Relationships)
Force due to Acceleration: The force to overcome the
combination of several load and inertia components
can become a large factor in high speed applications.
The following information and mathematical formulas
will be required to calculate the overall
requirements.Force required = load mass +
acceleration + external
force + seal friction.
• Load mass (in pounds) can be total weight or a
percentage (%) of total weight as dictated by
angle of incline and/or coefficient of friction.
• Acceleration Force = load mass x acceleration
• Load Mass = [mass/386.4 (gravity)]
• Acceleration = [Max. velocity (in./sec.)/time
to move (sec.)].
• External Force: Any changes made to the load
due to external sources (example would be an
addition or subtraction of weight due to a box
coming on or off a conveyor).
• Seal Friction: Use 10% of maximum force.
104
ELECTRO-HYDRAULIC PRODUCTS
FLUID POWER FORMULAS
Basic Formulas
Formula for: Word Formula: Letter Formula:
Flow Rate = Force (pounds) F F
Fluid Pressure P= or psig =
Unit Area (sq. inches) A A
(in pounds per square inch)
Velocity through Piping Velocity = 0.3208 x Flow Rate thru I.D. (gpm) V = .3208 (Q)
Internal Area (sq. Inches) A
(in feet per second)
1 1
Compressibility of a Fluid Compressiblity = CB = (See Note 2 Below)
Bulk Modulus of Fluid BM
(For 32 SUS to 100 SUS) Centistokes = 0.2253 x SUS - 194.4 Cs = 0.2253 (SUS) - 194.4
SUS SUS
Viscosity to Centistokes
(For 100 SUS to 240 SUS) Centistokes = 0.2193 x SUS - 134.6 Cs = 0.2193 (SUS) - 134.6
SUS SUS
Pump Formulas
Formula for: Word Formula: Letter Formula:
rpm x Pump Displacement (cu. in./rev) n (d)
Pump Outlet Flow Flow = Q=
231 231
(in gallons per minute)
105
ELECTRO-HYDRAULIC PRODUCTS
FLUID POWER FORMULAS
Actuator Formulas
Formula for: Word Formula: Letter Formula:
Area = π x Radius (inches)
2 A = 3.14 (r2)
Cylinder Area
Area = π x Diameter2 (inches) A = 3.14 (D2)
or A = 0.785 (D2)
(in square inches)
4 4
Cylinder Force Force = Pressure (psig) x Net Area (sq. in.) F = psig x A or F = P (A)
(in pounds, push or pull)
Flow rate (gpm) x Pressure (psig) x 36.77 Q (psig) (36.77) Q (P) (36.77)
Torque = T= T=
rpm n n
(in inch-pounds) (See Note 3 Below)
106
About Continental Hydraulics Continental Hydraulics Distributors are located in
every major industrial region in North America, and
Continental Hydraulics grew from the need for highly throughout the world.. They provide assistance in
reliable fluid power components. Because existing selecting components and developing systems. They
hydraulic components couldn t meet the performance also provide a readily available supply of products,
and reliability standards of DoAll saws, Continental parts, after-sale service and training. If you have
Machines began to manufacture pumps, valves and special design requirements, Continental Hydraulics
power units. As the reputation for these components Regional Managers can recommend special products to
spread, so did the demand. Continental Hydraulics meet your specific design or performance criteria.
Division was formed in 1962 to design, manufacture
and sell reliable hydraulic components around the We believe that Continental Hydraulics products are
world. the finest you can buy. We encourage you to ask your
Continental Distributor for a list of references in your
Today, whenever reliable, precise hydraulic power is area. Check our reputation for performance, reliability,
required, Continental Hydraulics products meet the delivery and service. Find out why people who buy
need. They re found in applications as diverse as Continental stay with Continental.
machine tools, plastic molding machines, marine
auxiliary power controls and deck handling equipment,
heavy construction, oil field and farm equipment and
foundry mold handling equipment.
Continental products are born in an extensive research
and design facility. Every product - every new design
undergoes extensive laboratory evaluation. Then field
testing insures that the product or design meets or
exceeds high standards for performance and service
life.
Reliability also comes from our modern automated
production facilities. Sophisticated in-process quality
control and 100% product testing maintain our rigid
quality standards in each and every product.
Why settle for close enough when you
need hydraulics?
Continental Hydraulics offers a complete line of Distributors who know how to help — Anyone can
products to meet your need for reliable, precise fluid say, “Here’s our catalog, take your pick.” Continental
power. Turn to Continental for vane and piston Distributors work with you to find out what you need,
pumps, a full line of control valves, integrated and with our engineers to make sure you get it.
hydraulic circuits, and hydraulic power units.
Service and support — To provide maximum service
Continental’s products are used in diverse applications and assistance, Continental Hydraulics maintains a
such as plastic molding machinery, machine tools, strong distribution network, with representatives
pulp and paper machines, marine auxiliary power throughout North America and around the world. The
controls and deck handling equipment, and masonry average Continental Distributor has been with us for
product production equipment. 15 years. He’s got repair and replacement parts, and
the skill to solve your hydraulics problem.
Our Distributors work hand-in-hand with our Engineers
to select components and build systems that will meet
your toughest specifications. And they’ll suggest
creative solutions that can help save money or
enhance performance.
Whether you need a complete hydraulic power supply
or a single directional control valve, come to
Continental.
Because Continental Hydraulics is continually improving its products, specifications and appearance
are subject to change without notice.
Form No. 260088 Rev. 9/05 © 2002 Continental Hydraulics Printed in U.S.A.