PRODUCTS 13
CONTENTS
CVS 40 / 60 / 100 Staircase Connectors 13-03
STAIRCASE
PRODUCTS
CVS 40 / 60 / 100 STAIRCASE CONNECTORS
The CVS 40 / 60 / 100 staircase products are used for connecting precast staircases to concrete shear
walls, through the use of a bearing that rests within the shear wall.
The former for the cast in part is re-usable. The former is secured by two screws and can be removed once
the concrete has cured.
The inner bearing part of the connector slids into the pocket in the shear wall on the construction site.
CVS bearers are produced under ISO 9001.
HF HF
HF
HF
M8 M8 H1 H
M8 H11
M8 H1
L1 L B1 B
L11 B11
L1 B1
La max 110
www.cfsfixings.com 13 03
REINFORCEMENT ARRANGEMENT CVS Stair connector System - element thickness, extra reinforcement and distance for fixing
maximum gap between concrete parts for full design capacity for all types is 4cm/ increasing the gap to 5cm =>reduced design capacity 35kN, 55kN/95kN
Bar No 1
C 30/37
C 35/45
C 30/37
C 35/45
C 30/37
C 35/45
C 30/37
C 35/45
C 30/37
C 35/45
C 40/50
C 30/37
C 35/45
C 30/37
C 35/45
Front Shear Bar Concrete
thickness of
mm 150 175 200 175 200 200 250
concrete part
No of units 2 2 1 1 1 1 2 2 2 1 1 2 2 1 1
Diameter - ds mm 12 12 16 16 16 12 12 12 10 16 16 16 16 20 20
Lb,net mm ≥ 60 ≥ 60 ≥ 85 ≥ 85 ≥ 110 ≥ 110 ≥ 85 ≥ 85 ≥ 110 ≥ 110 ≥ 110 ≥ 110 ≥ 110 ≥ 160 ≥ 160
La≥5xds mm ≥ 60 ≥ 60 ≥ 80 ≥ 80 ≥ 70 ≥ 60 ≥ 60 ≥ 60 ≥ 50 ≥ 80 ≥ 80 ≥ 80 ≥ 80 ≥ 100 ≥ 100
Design capacity - VRd,fs kN 38.8 43.9 36.6 41.5 41.5 40.3 54.9 62.3 59.2 53.7 58.5 94.8 107.4 86.2 97.7
• Anchorage of shear bars may
Back shear rebar (2) with bent ends
be bent either perpendicular or
aligned to CVS. No of units 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2
Diameter - ds mm 16 12 12 12 12 12 16 16 16 16 16 12 12 12 12
• Shear bar may be vertical or at an
angle as shown. Lb,net mm 100 100 100 100 100 100 100 100 100 100 100 110 110 110 110
NOTE:
Correct position of
reinforcement rebars
1 and 2. Ensure close
proximity of the rebars to
CVS Staircase Connector.
Reinforcement bar 1
must be in contact
with staircase
connector
13 04 www.cfsfixings.com www.cfsfixings.com 13 05
Connector With Typical Additional Reinforcement
To reduce the noise transmission, an insolating pad can be inserted into the wall pocket underneath the
bearing part.
The staircase connectors, made of material S355 are available in four different load groups. The product
*Fire protection under the CVS staircase connector in the joint must be considered by the designer
Pocket to be formed
or structural engineer. CFS recommends to use mineral wool or CFS fire stop. Please see CFS Site
by contractor Catalogue for further information.
*Designer can consider step and sound reduction. For schools, hospitals, hotels and offices it is
recommended to consider (min 10mm) elastic joint between landing and wall.
EVATION
1:5 @ A3
For more information about progressive collapse staircases please contact CFS.
calculations or technical literature prior to ordering or using our products.
All dimensions are in mm. Do not scale off this drawing, use the dimensions
ELEVATION 1 shown.
Disclaimer
1:3 @ A3 This document has been prepared for the titled project or named part thereof and
should not be relied upon or used for any other project without an independent
13 06 www.cfsfixings.com www.cfsfixings.com 13 07
check being carried out as to its suitability and prior written authority of Construction
Fixing Systems Ltd. (CFS) being obtained. CFS accepts no responsibility or liability
for the consequence of this document being used for a purpose other than the
purposes for which it was commissioned. Any person using or relying on the
document for such other purpose agrees, and will by such use or reliance be taken
to confirm his agreement to indemnify CFS for all loss or damage resulting there
CVS-100-Custom from. CFS accepts no responsibility or liability for this document to any party other
the person for whom it was commissioned. This document has been prepared in
accordance with the CFS Design Protocol V1.1.
13 08 www.cfsfixings.com