4 GEW (INDIA) PRIVATE LIMITED Non Conformance Report 7 | Process Q ‘Cause of NOR Buppter [16 [comataint [1 | internat va | Processibepi Production o7/t272019 [ Norioot Cent L&T, MHPS ean ee jt Frame Assembly GAP No. GAP/GHATAMPURISECONDARY STRUCTURE/O1, R-00 Did. 23.02.17 Drawing No. & | 3873-110-FO1,Rev-0 & 3873-510-F01,Rev-0 DUT 101083873110F01 & Mark / DU No. | p44 101083873510F01 TI Non-conformity | F) Maior miner 1 Observation In Frame Assly. welded mark nos. 28 & 29 orientation not found as per drawing no. 3873-110-FO1,Rev-0 & 3873- 510-F01,Rev-0. Qty-01 set each. Be [Root Cate Hinvestigation Analysis: Drawing interpretation not done property. 4 Pon )B- ay Proper training is gi ned production supervisor regardi 1.) These mark nos. 28 & 29 need to cut first with suitable means grindingifiame cutting. 2.) After cutting weld edge preparation should be checked. 3.) Get the inspection clearance of these mark nos. at tack condition 4.) Use WPS no. GEW-WPS-FCAW.-008 for welding. A val 8 Sion | TEE loypla MONITORING Follow-up Remarks: Action Taken _[_] Partial Action O No Action: Reet hie on per The proprsat- (wor Checlead 4 tburd OK, Form No: GEW-GEN-09| 00