Test Observations :
Winding Resistance : 55.7887 Ohms Per Phase at 30ºC
Insulation resistance (Before and After HV Test) : Above 30 Mega Ohms.
H.V Test at 2 KV for 1 min : OK
Reduced voltage running up test at 239 volts in both directions : OK
No Load Test :
Volts : 415 Amps : 1.2 Watts : 158
Freq : 50HZ
Locked Rotor Test :
Volts : 215 Amps : 1.43 Watts : 359
Direction of rotation when facing the D-end : Clockwise
Earthing and Terminal marking : OK
Special Remarks :
This is to certify that the motor has been tested in accordance with IS/IEC 60034-1 and has been found to be
electrically & mechanically sound.