1. The document is a datasheet for an internal floating roof for a storage tank at the Nghi Son petroleum depot in Vietnam.
2. It provides specifications for an aluminum internal floating roof for a 15.29m diameter steel dome roof tank used to store M92/M95 gasoline and diesel.
3. The floating roof contractor will be responsible for designing, supplying, fabricating, installing and testing the internal floating roof system according to API 650 Appendix H standards.
1. The document is a datasheet for an internal floating roof for a storage tank at the Nghi Son petroleum depot in Vietnam.
2. It provides specifications for an aluminum internal floating roof for a 15.29m diameter steel dome roof tank used to store M92/M95 gasoline and diesel.
3. The floating roof contractor will be responsible for designing, supplying, fabricating, installing and testing the internal floating roof system according to API 650 Appendix H standards.
1. The document is a datasheet for an internal floating roof for a storage tank at the Nghi Son petroleum depot in Vietnam.
2. It provides specifications for an aluminum internal floating roof for a 15.29m diameter steel dome roof tank used to store M92/M95 gasoline and diesel.
3. The floating roof contractor will be responsible for designing, supplying, fabricating, installing and testing the internal floating roof system according to API 650 Appendix H standards.
1. The document is a datasheet for an internal floating roof for a storage tank at the Nghi Son petroleum depot in Vietnam.
2. It provides specifications for an aluminum internal floating roof for a 15.29m diameter steel dome roof tank used to store M92/M95 gasoline and diesel.
3. The floating roof contractor will be responsible for designing, supplying, fabricating, installing and testing the internal floating roof system according to API 650 Appendix H standards.
THIẾT KẾ, CUNG CẤP THIẾT BN VÀ THI CÔNG XÂY LẮP CÔNG TRÌNH
MỞ RỘNG KHO XĂNG DẦU NGHI SƠN GIAI ĐOẠN 1
Tài liệu số.: 305026-PVE-DD-ME-DAS-003 LXB.: A Tờ: 2/ 3
KIỂM SOÁT THAY ĐỔI
LXB Ngày Mục Mô tả thay đổi
A 1/10/19 0 04/10/2019 THIẾT KẾ, CUNG CẤP THIẾT BN VÀ THI CÔNG XÂY LẮP CÔNG TRÌNH Tài liệu số.: MỞ RỘNG KHO XĂNG DẦU NGHI LXB.: 305026-PVE-DD-ME-DAS-006 SƠN A GIAI ĐOẠNTờ: 1 3/ 3 DATASHEET FOR INTERNAL FLOATING ROOF 1 Indicates Information completed by Purchaser Manufacturer Purchaser or Manufacturer 2 Applicable to Proposal Purchase As built 3 For PV OIL Unit 4 Site NGHI SON Service M92/M95 5 No. Required 1 Set Size Type 6 Manufacturer Model Standard 7 P & ID No. 305026-PVE-DD-PR-PID-002 Serial No. 8 TANK INFORMATION 9 Tag. No. TK-202 10 Location of tank Above Ground 11 Type of tank Steel Dome Roof Tank (w. aluminium internal floating roof) 12 Tank Inside Diameter/ Height ID 15.29m / 13.5m o 13 Tank design pressure/Temperature -25/75mm H2O/70 C 14 Product M92/M95 3 15 Product SG 840 kg/m 3 16 Filling rate 90 m /h 17 Filling/Out nozzle size 6"/6" 18 Floating suction arm/ Inlet diffuser No 19 CA (Shell/Bottom/Roof) 2mm 20 TANK ROOF 21 Roof type/Roof construction Doom Roof/Structure Steel Profile 22 Manhole No./ Size 2 / 24" API STD 23 TANK SHELL 24 Type Butt welded 25 Clips inside/Reinforcing Ring No 26 Manhole No./ Size 2 / 24" API STD 27 Fire fighting equipment Yes (Water & Foam system) 28 TANK BOTTOM 29 Type CONE 30 Coating Bottom plate and shell up to 2m 31 INTERNAL FLOATING ROOF CONSTRUCTION 32 Design standard API STD 650 Appendix H 33 Type Float tube, non-contact (VTC) 34 Seal type Double wiper seal (VTC) 35 Anti rotation/ Anti static cable Yes 36 Manhole Yes 37 Pressure/ Vacuum vent Yes 38 Adjustable legs Yes 39 INTERNAL FLOATING ROOF MATERIAL (Note 2) 40 Deck plate/Float tube Alu./Alu. (VTC) 41 Seal VTA 42 Bolts & Nuts A193-B7/A194-2H/A307Gr.B/SS304 Alu. 43 Structure/Support Alu.(VTC) 44 WEIGHTS 45 Empty weight/Operation weight VTA 46 NOTES 47 1. VTA = Vendor To Advise, VTC = Vendor To Confirm 48 2. Vendor to verify that specified materials are suitable for the proposed service and design condition. 49 3. Vendor scope: 50 - Design, supply material, fabrication, packing, transportation, installation internal floating roof as per API 650 Annex H 51 - Perimeter primary/ secondary seal joint, seal joint for penetration willing piping 52 - Design Design, supply of auto bleeder valve valve, emergency hatch hatch, vacuum relief device (If any) 53 - All nozzle, manway, ground cable,support legs 54 4. All shell nozzles will be API low type 55 5. Size & quantity of venting devices to be determined by vendor/manufacturer.