Declaratii Conf Pompe 1

You might also like

Download as pdf
Download as pdf
You are on page 1of 6
SALVATORE ROBUSCHI & C. s. Via Segré, T1/A - 43122 PARMA (ITAL! Teletono + +39 0821 606285 ra Telefax + +39 0521 606278 mall sr@ealvatorerobuschi.com PEC. : salvatorerobuschi@pecwise.t ‘Web! httpl/www.satvatorerobuschi.com SALVATORE ROBUSCHE POMPE PARMA DICHIARAZIONE DI CONFORMITA' CE EC DECLARATION OF CONFORMITY Pompa centrifuga / Centrifugal Pump Sezione 1 - Dati caratteristici / Technical data Cliente / Customer: SC TAPFLO ROM SRL Matricola n° / Serial number : 2010018094 Pompa tipo / Pump's type : RDV 32-20CR 2B55 A 170 3 Sezione 2 / Section 2 - Direttive e norme applicabili / Directives Direttiva Macchine / Machine directive 2006/42/EC Direttiva EMC / EMC directive 2014/30/UE Direttiva bassa tensione / low tension 2014/35/UE Direttiva sicurezza macchinario/ pump's security EN 809:1998 Direttiva sicurezza macchinario/ pump's security EN 12100:2010 Direttiva sicurezza macchinario/ pump's security EN 13857:2008 Sezione 3 / Section 3 - Dichiarazione / Declaration Noi Salvatore Robuschi & C, dichiariamo sotto la nostra esclusiva xesponsabilita che la pompa di cui alla Sezione 1 @ conforme alle Direttive e alle Norme richiamate nella Sezione 2, quando utilizzata in osservanza alle prescrizioni contenute nel "Manuale di uso e manutenzione" We, Salvatore Robuschi & C, declare that the pump specified in Section 1 is contructed in accordance with the normatives listed in Section 2 and must be used observing the operated handbook. PARMA 27.06.2018 L'amministratore Michele Robuschi Hichle Cobuoel Page 1 of SALVATORE ROBUSCH! & C. s.r.1. Via Segre, 11/8 - 43122 PARMA (ITALIA) Telefono + +99.0521 608285 ra, Toletex + + 39:0821 608278 ee Email : sr@salvatorerobuschi.com Directive 2014/34/UE (ATEX) PEC” : salvatororobuschi@pecwize.t Web: hrtp:/iwww salvatororabuschi.com SALVATORE & vi Doeraraates DECLARATION OF CONFORMITY jection 1 - Technical data Pump's type RDV 32-20CR 2B55 A 170 3 Serial number 2010018094 ATEX number IT 3G ¢ Tx F1000 ITEM 57-P-001 Max room temperature Other data: see the enclosed document (Conformity declaration component) Section 2 - Directives Machine directive 2006/42/EC EMC directive 2014/30/UE ATEX directive 2014/34/UB Norma UNI EN 13463-1:2008 Non-elettrical equipment for potentially explosive atmospheres. Basic method and requirements Rule EN 13463-5:2008 Non-elettrical equipment for potentially explosive atmospheres. Protection by constructional safety Rule UNI EN 809:1998 Pumps and pumping groups for liquids. General safety requirements Rule UNI EN 12100:2010 Safety of machinery. General principles for design Risk assessment and risk reduction. Rule UNE EN 13857:2008 Safety of machinery. Safety distances to prevent hazard zones being by upper and lower limbs. Section 3 - Declaration We, Salvatore Robuschi & C., declare on cur own responsibility, that our pump specified in the Section 1 and annex is constructed in accordance with the directives and rules in the Section 2, when operating according to the working conditions described in the "Conformity Declaration Complement" and prescriptions written in the "Operating and instruction manual" and its relevant addendum Ex ©.8.0 Michele Robuschi Haehle Pabwoel Page 1 of 2 SALVATORE ROBUSCHI & C. s.r Via Segre, 11/8 - 43122 PARMA (ITALIA) Teletono + 439 0821 606285 ra, jlofex + +39 0521 606278 Email: sr@salvatorerobuschi.com PEC: salvatorerobuschi@pecwise.it ‘Web! httpifwwnw salvatorerobuschi.com Directive 2014/34/UE (ATEX) SALVATORE ROBUSCHE POMPE PARIA CONFORMITY DECLARATION COMPLEMENT order no.: 2000018544 dd 17.05.2018 Your reference: 001/Robuschi/2018 Ref. 000030 DV 32-20CR 2855 A 170 3 Item: 57-P-001 Serial number: 2010018094 Pump Configuration Installation area Liquid Liquid Kinematic Viscosity Density Min working temperature Liquid Temperature 9 _NPSHr (Required from the pump) 10 Working Capacity 11 Working Head (m) 12 Working Absorbed Power 13. Transmission Type 14 Coupling supply 15 Coupling Spacer 16 Impeller Type 17° Impeller Diameter 18 Solids Free Passage [mm] 19 Suction Port Diameter 20 Vertical Pump Execution 21 Seals Supply 22 Pump Required (La) Lenght 23 Pump Final Extim. Lenght (La) 24 Column Quantity 25 Plate Supply 26 Plate Type 27 Plate Shape 28 ‘A! dimen. /Diam. (Round Plate) 29 ‘BY dimen. /Diam. (Round Plate) 30 Plate Thickness 31 Airtight Plate Required 32 Note on auxiliary pipes 33. Note on auxiliary pipes 34 Note on auxiliary pipes 35 Note on auxiliary pipes 36 Discharge Pipe supply 37 Discharge Pipe type 38 Discharge Port Diameter 39 Discharge Flange Norm 40 Discharge Flange Face 41 Suction Strainer Supply 42 Suction Strainer Material IE 3G ¢ Tx F1000 Vertical Gr. ITB Zone 2 (Gas) 73 DRAIN (CRUDE/OTLY/WATER) , MAX 0,01% SAND, 5-10MICRON 20,6 mm2/s 2,10 kg/am3 -40 °c 80 0,70 m 20,1 m3/h 42,6 2,53 KW Flex Coupling Coupling Included Coupling without Spacer Closea 285 mm NAA. 50 A(lubr. with pumped liquid) NA. 2.700,0 mm 1.695,5 mm 1 Included Acc. to Customer Specification Round Plate 600,0 mm 600,0 mm 20,0 mm No Included Standard 40 EN 1092 PNI¢ FF - Flat Face Not Included Not Present SALVATORE ROBUSCH! & C. 5.11 Via Segré, 11/8 - 43122 PARMA (TALIA) Telefono + +39 0521 608285 ra, Telefax > +99 0821 606278 mall: sr@salvatorerobuschi.com PEC: salvatorerobuschi@peowise.t Web: hutp:wa.salvatorerobuschi.com SALVATORE Fuse bacis CONFORMITY DECLARATION COMPLEMENT order no.: 2000018544 dd 17.05.2018 Your reference: 001/Robuschi/2018 43 Suction Pipe supply 44° Suction Pipe Material 45° Pump Main Material 46 Impeller Material 47° Pump Without Bronze Component 48 Bottom Bearing Bush Material 49 Interm. Bearing Bush Material 50 Column Material 51 Shaft Material 52 Bearing Housing Material 53 Support Plate Material 54 Lubricant Level Control 55 Level Probe Supply 56 Electric Motor supply 57 Motor Category 58 Std. Electric Motor Brand 59 Electric Motor Brand(on spec.) 60 Motor Power 61 1. Motor Poles 62 Motor Shape 63 Motor Size 64 Operating motor voltage 65 Nominal Motor Frequency 65 Motor Protection 67 Motor Efficiency Class 68 Pre 69 Painting cycle 70 Pump RAL 71 Included Certificates 72 Included Certificates 73° Included Certificates Note: PUMP MUST NOT RUN DRY. Page 1 of 1 Directive 2014/34/UE (ATEX) Not Included Not Included EN1.4408-A351 CFAM-AISI 316 EN1.4408-A352 CFOM-AIST 316 No Rulon J On SS Support Not Present Aisi 316L Aisi 316u, Aisi 316L carbon steel Not Nedeed Not Included included Exd Motor NA. cemp 5,50 KW 2 BS 1328 500-50 50 Hz Iss NAL NA. STD-RALS 5010 CB conformity Cert. ATEX Conformity Certificate Certificate of Quality -Poliacr.cat. “PUMP HAS NOT TO RUN WITH CLOSED DISCHARGE PORT -PUMP MUST NOT VIBRATE. -THE INSTALLER/USER HAS TO install a minimum sensor in the tank to ensure the minimum level suspension depth of the pump, according to the technical specifications written in the "Operating instruction manual".

You might also like