RELEASE NOTES for INSITE™ 7.

Note: If it is difficult to read this document with Microsoft notepad, click

on "Word Wrap" under the "Format" menu item or 'maximize' the Notepad

window. To print this and have the tables in a valid format set the

page margins to 0.25.

CAUTION: Please verify that the Calibration you select to download to an ECM

is appropriate for that specific ECM. Permanent damage could occur if

incorrect calibrations are downloaded.

Contents

A. Issues with INSITE™ 7.4

B. Issues with ECM Applications

C. Datalink Adapters INLINE, INLINE I and INLINE II, RP1210A

D. Datalink Adapter Compatibility Matrix

E. Version Compatibility

F. Special Issues

G. Suggestions and Tips

H. Saving Data from previous versions of INSITE™

A. Issues with INSITE™ 7.4

PCID's

- It is becoming common for INSITE™ to be installed and registered with an

Administrator account, and then used with a Limited User account. On some
computers, INSITE™ does not have access to the same security settings on

Limited User accounts as it would on Administrator accounts. This causes

a different PCID to be displayed for the Limited User account after INSITE™

has been registered with the PCID displayed for an Administrator account.

It is recommended after installation to register the INSITE™ PCID displayed when

logging into the Limited User account.

- For Calibration Authorization passwords contact your Distributor with the

INSITE™ 7.4 PCID.

- New users can enter both the Basic and Functional Password when first opening

INSITE™. If the Basic is entered on the "New Functionality Password" window,

INSITE™ will open in Read Only. The Functionality Password will have to be

entered under the Tools > Options > Security window. (DB_G00149670)

Help and Fault Information System (FIS) Files

- Some Fault Information System (FIS) files may display a "Script Error" window when

opening the Fault Code troubleshooting steps. This has been seen on Windows 7

and Internet Explorer 8.

Work around: Click Yes or No on the Script Error window to open the

troubleshooting steps. (DB_G00152716)

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Installation

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- When installing Chinese version of INSITE™ on Windows XP, East Asian Languages
Option in the Regional Settings must be selected in order for the Characters

to appear correctly.

- INSITE™ 7.4 does not support Windows 95, 98, 98SE, ME, NT and 2000.

- Windows XP, Vista or 7 must have full administrative privileges to install.

After installation, INSITE™ can be run with User privileges.

- Refer to the following table for the hard drive space required for the

installation of INSITE™ 7.4. This is based on the assumption of "C" drive

being the drive on which the Operating System is installed.

+----------------------------+----------------------------+

|Installing on the "C" drive |Installing on the "D" drive |

| | |

+------------------+----------------------------+----------------------------+

| | | |

| | | |

| Space required | C:2 GB | C:930 MB |

| at the time of | | |

| installation | D:N/A | D:2 GB |

| | | |

| | | |

+------------------+----------------------------+----------------------------+

| | | |

| Space required | C:750 MB | C:200 MB |


| after the | | |

| installation | D:N/A | D:650 MB |

| | | |

+------------------+----------------------------+----------------------------+

- It is recommended that you always reboot your PC after installing software.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Connections

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- Error Messages for communication failures:

- Error 5200: Indicates communication loss between computer and the datalink

adapter.

- Error 5201: Indicates communication loss between the datalink adapter and

the ECM.

- Error 5202: Indicates no communication could be established between the

datalink adapter and the computer.

- Error 5204: Indicates no communication could be established between the

datalink adapter and the ECM.

- Verify that the infrared port is disabled so the serial port is only being used

for ECM communications.

- If you have the Palm Pilot Hot Sync Manager on a PC that only has one serial port,

you must disable the Hot Sync Manager before connecting to an ECM.
- An Internet connection is required before selecting the "http://www.cummins.com"

or "http://insite.cummins.com" link from the Help > About INSITE™ dialog.

- Auto Configure and "Datalink Adapter Connection Test" does not find the adapter

when connected to a multi-module system.

Work Around: Manually configure the Datalink adapter connection. (DB_G001514410)

Advanced ECM Data

- To print Advanced ECM Data Views, select the parameter, right click and

click on Print.

- If the display becomes distorted or cannot be completely viewed, close the

Advanced ECM Data View and then reopen it. Resizing can cause the views to

become distorted.

Calibrations

- Automotive applications will have a default setting of "ON" for the Save and

Restore option in the Calibration Download dialog.

- Industrial applications will have a Default Setting of "OFF" for the Save and

Restore option in the Calibration Download dialog.

- When performing a Calibration Download, the "Save and Restore" option may be

grayed out for some applications.

- To decrease calibration download times please make sure all applications other

than INSITE™ are closed. Always use the J1939 protocol and engine connector
when available.

- Computers with less than the minimum recommended hardware requirements will have

an extended Calibration Download time. Make sure that screen savers and suspend

modes are disabled.

Display & Graphics

- Features and Parameters columns will be narrow which will widen the rows if the

screen resolution of the display is above 1280 by 1024. (DB_G00152772)

Work Around: Manually adjust the width of the first column or change the screen

resolution to:

800x600

1024x768

1280xAny

1152x864

- Data Monitor/Logger columns will be narrow which will widen the rows if the

screen resolution of the display is above 1280 by 1024.

Work Around: Change the screen resolution to 1280 X 1024 or lower or manually

adjust the width of the first column. (DB_G00118518)

- The use of Large Toolbar buttons will not display all icons on the toolbar.

Work Around: Under Tools > Options > General, select Small Buttons in the

Display Options. (DB_G00150835)

- Use of Extended Desktop feature in Windows XP or Vista is not supported by INSITE™ 7.4.

- To Disable the "Display Feature Names" option for the view bar, the checkbox
in Tools/Options/General/Viewbar/Display Feature Names must be unchecked.

- If your PC monitor display is set to "Large Fonts", not all information in INSITE™

may be displayed. It is recommended to use small fonts.

ECM Diagnostic Tests

- When operating an ECM Test, make sure the Key switch remains in the ON position

until the Stop button is selected in the ECM test.

- If the display becomes distorted or cannot be completely viewed, close the

ECM Diagnostic Tests View and then reopen it. Resizing may cause the view to

become distorted.

- When running the Lift Pump Override Test, the test will run for 60 seconds

and then INSITE™ will shut off the lift pump. The user needs to listen for the

lift pump to shut down and then close or restart the test.

Fault Codes

- Some Fault Information System (FIS) files may display a "Script Error" window when

opening the Fault Code troubleshooting steps. This has been seen on Windows 7

and Internet Explorer 8.

Work around: Click Yes or No on the Script Error window to open the

troubleshooting steps. (DB_G00152716)

- If the Fault Codes window displays "No ECM Connected" while communicating, close
and reopen INSITE™.

Printing

- When using print preview use the tool bar magnifying glass to display the

text in a larger view.

- The Print options will be disabled when no printers are available. This

includes the Page Setup, Print and Print Preview options.

Work around: Setup/install a printer on the PC and retry the INSITE™ print

selection.

Simulators

- Values shown in simulator do not reflect real values that would be seen by a user

when connected to an engine.

- When creating a Work Order on the QSK19G/45G/60G, QSV81/91 simulator, Error 10411

is displayed and a work order is not completed. (DB_G00151367)

- The Aftertreatment High NOx Reset Test on the ISL8.9 CM2150 SN(Euro 4.5) and

ISX 11.9/15 CM2250 simulators does not run. After clicking the Start button,

"Error Number 40203 An internal error has occurred in the INSITE™ program" is

displayed. (DB_G00148885)

- The Power Generation Tunning Test on QSK38 CM850/CM2150 and QSK50/60 CM850/CM2150

Power Gen Simulators does not run. After clicking the Start button,
"Error Number 40508 An internal error has occurred in the INSITE™ program" is

displayed. (DB_G001513680)

Trip Information

- When resetting Trip Information be sure to key off for 30 seconds before

continuing. The ECM may have an invalid foot print if the key is not

switched off for the required amount of time.

Work Orders/ECM Images/Templates

- Double clicking on an image file (.eif format) will open INSITE™, import the image

and automatically connect to this image.

- Double clicking on the converted image files (.csv format) will not open them

with the correct format in Microsoft Excel.

Work around:

Follow the steps below to open a converted (.csv format) image file in Excel:

- Open Microsoft Excel

- Click on File -> Open

- Change the Files of type field to "All Files(*.*)" or "Text Files (*.csv)

- Select C:\Intelect\INSITE\Export\desiredimage.csv

- The "Text Import Wizard" will open

- In Step 1 of the wizard, make sure the "Delimited" option is selected and

click "Next"
- In step 2 of the wizard, uncheck the "Tab" box and check the "Comma" box

and click "Next"

- In step 3 of the wizard, click on "Finish"

- Format columns as desired

- When upgrading to INSITE™ 7.4 from any version of INSITE™, the following files

need to be backed up:

- C:\Intelect\INSITE\WorkOrders

- C:\Intelect\INSITE\UserSettings\data.wo

- When using templates it is advised to verify the first template sent to the target

vehicle. This helps ensure the template configuration is correct for subsequent

vehicles.

- When using templates verify that the ECM code is compatible or the same.

- When naming images and templates, special characters cannot be used

(i.e. & ^, etc).

B. Issues with ECM Applications

- User Activated Data Logger (UADL) is not supported.

CELECT

- When calibrating a CELECT, you will need the ECM serial number and the SC option

that is displayed in INSITE™ to receive calibration authorization password(s)

from QuickServe Online. INSITE™ only displays the SC option and to get a valid
password the SC Option and ECM Serial Number needs to be entered into the website.

ISBe4 (4 and 6 cylinder) CM850

ISLe4 (6 cylinder) CM850

ISX/ISZ13 CM2150 SN

ISF2.8 CM2220 AN

ISF3.8 CM2220 AN

ISB

ISL

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- High NOx Reset test

This test cannot be run more than once on a single key cycle.

Work Around. If this test needs to be performed more than once, key off before

restarting the test.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Signature/ISX - CM570

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- Features and Parameters

- J1939 Multiplexing

If the "J1939 Multiplexing" feature and its sub-features are enabled,

they cannot all be disabled at the same time and sent to the ECM,

INSITE™ displays an error dialog stating that "The write to ECM failed

for the requested parameters."


- Engine Brake Control

If a phase 8 calibration is currently in the ECM, the Engine Brake

Delay Time value might be set to zero regardless of the actual value

entered for this parameter in the Features and Parameters.

Work around:

Check the value for the Calibration Software Phase in INSITE™ (can be found

in Features & Parameters/System ID & Dataplate/Calibration Information).

If it starts with 08, then download the latest version of the ECM Code to

resolve this issue.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

ISX - CM870

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- The "Injector Check Valve Diagnostics Test" might not run for some earlier ECM

code phases on the ISX - CM870 ECMs. Please refer to the table below

for more details.

+----------------------------+------------------------------+

+----------------------------+------------------------------+

| ECM Code Phase | Test Status in INSITE™ 7.4 |

+----------------------------+------------------------------+

+----------------------------+------------------------------+

| | |

| Phase 5.4.6.02 and prior | Test will not run |

| | |
+----------------------------+------------------------------+

| | |

| Phase 5.4.7.11 and post | Test will run |

| | |

+----------------------------+------------------------------+

| | |

| Phase 6.5.1.01 and prior | Test will not run |

| | |

+----------------------------+------------------------------+

| | |

| Phase 6.5.2.0x and post | Test will run |

| | |

+----------------------------+------------------------------+

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

CELECT Plus

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- INSITE™ ReCon ECM Procedure:

CAUTION:

To Calibrate this ECM, use the following steps:

1. Hook up battery power

2. Turn key switch ON for 10 seconds

3. Turn key switch OFF

4. Launch INSITE™

5. Connect

6. Click “OK” to ROM boot message

7. Select “Calibration Selection”


8. Choose the appropriate calibration code and transfer to ECM

9. Turn key switch ON when INSITE™ prompts

(E03016)

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

QST 30

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- Inquire Data Extraction

CSV file created during Inquire data extraction on QST30 ph5 ECM, contains

only left bank fault code data and not of right bank's.

(DB_G00054295)

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

QSK19/45/60-CM500

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- When calibrating a QSK19/45/60-CM500 ECM using an INLINE II, 4 or 5, avoid using a

connection with "Auto Detect" as the calibration might fail.

Work around:

Use an INLINE II, 4 or 5 connection that uses J1587/J1708 instead of Auto Detect.

QSK19G/45G/60G, QSV81/91

- Work Orders

Images in a QSK19G/45G/60G, QSV81/91 Work Order can only be connected to as

individual images and not as a system

(DB_G00052563)
- When connected to a work order image, the AEM feature will cause errors to

occur. The tool displays error 35054 when connected to either child ECM

and selecting AEM Enhanced Fault snapshot log or AEM Trend Log.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

QSM 11

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- Calibration Selection

When calibrating QSM11 engines utilizing Multiple Unit Synchronization,

J1708 protocol must be used. The calibration will not download to the ECM

successfully if J1939 protocol is used. If both J1708 and J1939 protocols

are available on the Datalink, an INLINE or INLINE I must be used to access

the J1708 protocol or use an INLINE II, 4 or 5 connection that uses J1587/J1708

instead of Auto Detect.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

C. Datalink Adapters INLINE, INLINE I, INLINE II and RP1210A

- The INLINE II Adapter must contain Version 9.28 or greater firmware to be

compatible with INSITE™ 7.4. You must use the Reflash program that was

installed with INSITE™ "INLINE Reflash".

- For instructions on how to Reflash your INLINE II Adapter refer to the help

button in the INLINE Reflash program.

- INSITE™ 7.4 supports all the Cummins® Service Products INLINE, INLINE I,

INLINE II and RP1210A (INLINE 4/5) Adapters.


The INLINE and INLINE I Adapters support the J1587/J1708 protocol and

INLINE II and RP1210A (INLINE 4/5) Adapters currently supports J1587/J1708

and J1939 protocol for most ECM applications.

- The latest Inline 4/5 drivers will automatically be installed/upgraded with

the installation of INSITE™ 7.4. The drivers can also be downloaded from

http://inline.cummins.com

After installing the latest drivers, be sure to reflash the adapter to the

latest firmware.

D. Datalink Adapter Compatibility Matrix

+----------------------------------------------+

| INSITE™ 7.4 |

+-------+---------+-------------+--------------+

|INLINE |INLINE I | INLINE II | INLINE 4/5 |

| | | | (RP1210A) |

+---------------+-------+---------+-------------+--------------+

| Program | J1587 | J1587 |J1587 |J1939 | J1587| J1939 |

| | J1708 | J1708 |J1708 | | J1708| |

+---------------+-------+---------+-------------+--------------+

|480 C-E | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|B5.9 Gas | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|L10G/C8.3G | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+
|C Gas Plus / | | | | | | |

|B Gas Plus | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|L Gas Plus | | | | | | |

| | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISB5.9 G CM2180| | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISL G CM2180 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|CELECT | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|CELECT Plus | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|CELECT PlusInd | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|CENTINEL | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|CENTRY | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|Gas Compression| | | | | | |

|GTA/KTA | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|Gas CENSE | | | | | | |

|QSV81/91 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|B3.9/5.9/C8.3 | | | | | | |

|CM2150 | | | X | | X |

+---------------+-------+---------+------+------+------+-------+
|ISB | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------|

|ISB Chrysler | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISBe/ISBe4 | | | | | | |

|4 & 6 Cylinder | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISBe4.5/ISBe5 | | | | | | |

|- CM2150 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISC/ISL | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISC/Transit | | | | | | |

|Bus ISL8.3- | | | | | | |

|CM850 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISB6.7 CM2250 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISC8.3 CM2250 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISB/L-CM850 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISL8.9 CM2150 SN | | | | | |

| (Euro 4.5/5) | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISL9 CM2250 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISF2.8CM2220/AN| | | | X | | X |

+---------------+-------+---------+------+------+------+-------+
|ISF3.8CM2220/AN| | | | X | | X |

|---------------+-------+---------+------+------+------+-------+

|ISLe4.5/ISLe5 | | | | | | |

|- CM2150 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISM | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISM-CM870/875 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|ISM-CM876 | | | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|ISM11-CM876 SN | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISX-CM871 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISX/ISZ13 | | | | | | |

|- CM2150 SN | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|ISX-CM2250 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|Signature/ISX | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|Signature/ISX | | | | | | |

| - CM870 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|PIM | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|QSB | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+
|QSC8.3/QSL9 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|QSK19/45/60/78 | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|QSK19/23-CM500 | X | X | X | | X | |

+---------------+-------+---------+------+------+------+-------+

|QSM11 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|QST30 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSK19G/45G/60G | | | | | | |

|QSV81/91 | X | X | X | X | X | X |

+---------------+-------+---------+------+------+------+-------+

|QSK19/23/38/50 | | | | | | |

|/60/78-CM850 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSB/C/L-CM850 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSB5/7-CM850 PG| | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSB3.3-CM2150 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSB4.5/6.7 | | | | | | |

|CM2250 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSL 9 CM2250 | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSK23/60/78 | | | | | | |

|CM850 PG | | | | X | | X |
+---------------+-------+---------+------+------+------+-------+

|QSL9-CM850 PG | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QSM11-CM876 PG | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

|QST30-CM850 PG | | | | X | | X |

+---------------+-------+---------+------+------+------+-------+

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Datalink Adapter Issues

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- Do not substitute cables, except as indicated in the INLINE II Product

Announcement Bulletin.

- Do not use an extension cable on the Datalink side of the INLINE II adapter.

- Incompatible cables may damage the INLINE, INLINE I INLINE II and/or INLINE 4/5

adapter or personal computer and will void warranty.

- Incompatible cables may cause communication issues with INSITE™.

- INLINE II or INLINE 4/5 adapter may intermittently lose communication. If your

Datalink adapter has communication problems, disconnect power from the adapter

for 5 seconds and then reconnect. The INSITE™ program does not need to be shutdown.

- There is a Reset Adapter feature under the Tools - Datalink menu that will

correct some software communication errors with the INLINE II and INLINE 4/5.
- The main harness (backbone) has a maximum overall length of 40 meters.

- A J1939 stub, which can be a connection point for ECM's and/or the

INLINE II or INLINE 4/5 Datalink adapter, cannot exceed a maximum length of 1

meter.

- At each end of the backbone harness is a terminating resistor with a

nominal resistance of 120 Ohms, it will measure 60 Ohms when you measure

across the Datalink.

- The INLINE II and INLINE 4/5 Adapters should be connected to a continuous

battery power supply. When making adjustments with INSITE™, including calibration

download, the operator will be asked to switch the key off for 30 seconds.

If the adapter is getting its power from a power source dependent on the key

switch status, such as the lighter adapter inside the cab, the Adapter will lose

power, which will result in INSITE™ losing connection to the ECM. This will

require the operator to reconnect to the ECM and the adjustments might not

have been saved.

E. Version Compatibility

INSITE™ Software and Operating System Compatibility:

- INSITE™ 7.4 is compatible with the following operating systems:

Windows XP SP3, Windows Vista, and Windows 7. Both 32-bit and 64-bit

versions are supported.

- Contact the local Cummins® Distributor to register your new INSITE™

Service Tool and receive a password.


F. Special Issues

Power Savers

- Turn off any power saver features when communicating with an ECM,

especially when downloading a calibration to an ECM. These commands

require the computer to communicate with the ECM, but do not require

you to interact with the computer. As a result, the power saver does

not recognize that a command is in progress and automatically turns

off the computer. This may disable the COM port, hard drive and other

hardware required for the calibration download process.

G. Suggestions and Tips

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- Do not turn off the PC while INSITE™ is running. Exit INSITE™ before

turning off the computer. Disk and database corruption can occur

if you do not exit INSITE™ before turning off the computer.

- If the PC CMOS battery is not working, please make sure you reset

the PC date and time before you attempt to open INSITE™.

- To back up all Work Orders and Images with INSITE™ 7.4, select the

"Export All" from the right click menu while highlighting any Image.

H. Saving Data From Previous Versions of INSITE™


- ECM Templates from earlier versions of INSITE™ 6.3A, 6.4, and 6.5 cannot

be used with INSITE™ 7.4. They can be printed.

- ECM Templates from INSITE™ 6.5.1, 6.5.2, 7.0 and 7.0 FP1/FP2 for the ISB CM2150,

ISC CM2150 and ISL CM2150 cannot be used with INSITE™ 7.4. They can be printed.

All other engine's templates can be used with INSITE™ 7.4.

JRE Created: INSITE™ 7.4 - March 2010

Document 6733-RLNO-07 Version 1.0.1