Professional Documents
Culture Documents
Coating Peel Off
Coating Peel Off
Figure 1 Winding Technology for Three Layer Steel Pipe Coating. Figure 2 Hose-Stretch Technology for Three Layer Steel
Source: Dow Pipe Coating. Source: Dow
1. DURABILITY The specific product design When comparing extruder output
AND IMROVED of DOW™ HDPE 12110G for the same materials
PROCESSING – makes it possible to combine DOW™ HDPE 12110G shows
BLACK TOPCOAT excellent ESCR and excellent a very good output
MATERIAL DOW™ flow behavior for exceptional characteristics, comparable to
HDPE 12110G processing on high output best competitive HDPE resins,
extruders. In figure 3 rheology as shown in figure 4.
results for DOW™ HDPE 12110G
Traditionally polyethylene are compared with competitive
materials for the three layer HDPE resins.
pipeline coating have been based
on low density polyethylene,
LDPE. Some are still used today
but during the last 10 years the
industry moved towards medium
density MDPE or high density
HDPE. Main reasons for the Log
Viscosity
change include higher operating (Pa s)
4
temperatures for the pipelines
and better understanding of
the needs in crack and impact
resistance at high and low
DOW™ HDPE 12110G
temperatures, e.g. under Competitive HDPE 1
3
extreme climatic conditions. Competitive HDPE 2
Output 6
(kg/h)
DOW™ HDPE 12110G
Competitive HDPE 1
5
Competitive HDPE 2
Troester Extruder 45 mm
2
Figure 4 Extruder Output for DOW™ HDPE 12 14 16 18
12110G and Competitive HDPE´s at 220 °C. RPM
Source: Dow
2. Durability Polyethylene based adhesives the control points at 1 year for
and Adhesion for three layer steel pipe 110 °C and 3 years at 100 °C
– Grafted coating have been in the focus with elongation at break higher
Adhesive for the last 10 years. Based than the 25 % minimum.
Amplify™ Gr 320 on a good understanding of Lifetime extrapolation was
fundamental market needs based on ISO 21003, part 2,
Dow has introduced high annex D, with extrapolation time
Dow has a long history in performance adhesives that can limits and factors according to
the development of grafted provide excellent peel strength EN ISO 9080, table 2.
polyolefin adhesives that performance at temperatures For lifetime extrapolation two
can help provide excellent up to 80 °C. The higher service calculations could be made.
performance in multilayer temperature of pipelines defined At 110 °C, 40 °C above
systems with polar substrates the need for specific maleic permanent service temperature,
like polyamide or EVOH but also anhydride grafted formulations a factor of 50 can be applied,
metals, e.g aluminum. Dow’s that are able to combine high > 8760 h corresponds to
portfolio of Functional Polymers peel strength at elevated minimum 50 years lifetime at
includes AMPLIFY EA ethylene- temperatures with good 70 °C. At 100 °C, 30 °C above
acrylate copolymers, AMPLIFY processing characteristics, but permanent service temperature,
IO ionomers and AMPLIFY GR also exhibit excellent long-term a factor of 18 can be applied,
grafted polyolefin resins that thermal stability. > 26304 h corresponds to
are used in a wide range of minimum 54 years lifetime at
applications from packaging Based on oven ageing testing of 70 °C.
and automotive compounds to AMPLIFY™ GR 320 at elevated
multilayer pipes. temperatures of 100 °C and
110 °C, a lifetime expectation
of minimum 50 years can be
calculated and predicted for
this adhesive. As shown in
figure 5, the material passes
%εB 1000
800
600
110°C
100°C
400 25%*
200
0
0 48 96 312 768 1536 6144 8760 12288 17520 24576 26304
* Minimum 25 % of initial elongation at break εB (t0) Figure 5 Oven Ageing Results on AMPLIFY™ GR 320.
Source: Dow
3. DEVELOPMENT AMPLIFY™ GR 320 but also winding, and water cooling.
OF A HIGH for testing its compatibility Peel strength performance
PERFORMANCE with a number of epoxy resins was tested in a tensile testing
3LPE COATING that are used in the global machine on 5 cm wide pipe
SYSTEM steel pipe coating industry. segments, figure 7. Cohesive
During the process all the steps failure in the adhesive layer is
were followed that are used achieved.
The lab coating line, as shown in a large scale coating plant: A typical result for a 80 °C peel
in figure 6, allows the coating Blasting, heating, powder epoxy strength test on the system
of 170 mm pipes. It was used application, adhesive application epoxy / DOW™ HDPE 12110G /
to help optimize processing and via extrusion or powder AMPLIFY™ GR 320 is illustrated
peel strength performance of spraying, toplayer extrusion and in figure 8.
Figure 6 Lab Coating Line for Coating of 170 mm Pipes. Figure 7 Peel Strength Testing on 50 mm Pipe Segments.
Source: Dow Source: Dow
1400 Test 1
1200
Force kN
1000
800
600
400
200
216 N/cm
0
Figure 8 Peel Strength Result for Epoxy / 10 20 30 40 50 60 70
DOW™ HDPE 12110G / AMPLIFY™ GR 320
Length mm
at 80 °C. Source: Dow
4. MEETING Typical peel strength values
STANDARDS WITH measured for combinations of
SYSTEM DOW™ different fusion bonded epoxy
HDPE 12110G / materials with DOW™ HDPE
AMPLIFY™ GR 320 12110G and AMPLIFY™ GR 320
are given in table 1.
North America NOTICE: Any photographs of end-use applications in this document represent potential end-use
U.S. & Canada 1-800-441-4369 applications but do not necessarily represent current commercial applications, nor do they represent an
1-989-832-1426 endorsement by Dow of the actual products. Further, these photographs are for illustration purposes
Mexico +1-800-441-4369 only and do not reflect either an endorsement or sponsorship of any other manufacturer for a specific
potential end-use product or application, or for Dow, or for specific products manufactured by Dow.
Latin America
NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred.
Argentina +54-11-4319-0100 Because use conditions and applicable laws may differ from one location to another and may change
Brazil +55-11-5188-9000 with time, the Customer is responsible for determining whether products and the information in this
Colombia +57-1-219-6000 document are appropriate for the Customer’s use and for ensuring that the Customer’s workplace
Mexico +52-55-5201-4700 and disposal practices are in compliance with applicable laws and other governmental enactments.
Dow assumes no obligation or liability for the information in this document. NO WARRANTIES ARE
GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
Europe/Middle East +800-3694-6367 PURPOSE ARE EXPRESSLY EXCLUDED.
+32-3-450-2240
Italy +800-783-825 NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications
may not be fully determined; (2) analysis of hazards and caution in handling and use are required;
(3) there is greater potential for Dow to change specifications and/or discontinue production; and
South Africa +800-99-5078
(4) although Dow may from time to time provide samples of such products, Dow is not obligated to
supply or otherwise commercialize such products for any use or application whatsoever.
Asia Pacific +800-7776-7776
+603-7965-5392 NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or
sample any product or service (“Product”) into any commercial or developmental application that is
intended for:
a. long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact
which exceeds 72 continuous hours;
b. use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic
devices” include, but are not limited to, pacemaker leads and devices, artificial hearts, heart
valves, intra-aortic balloons and control systems, and ventricular bypass-assisted devices);
c. use as a critical component in medical devices that support or sustain human life; or
d. use specifically by pregnant women or in applications designed specifically to promote or
interfere with human reproduction.
Dow requests that customers considering use of Dow products in medical applications notify Dow
so that appropriate assessments may be conducted.
Dow does not endorse or claim suitability of its products for specific medical applications.
It is the responsibility of the medical device or pharmaceutical manufacturer to determine that
the Dow product is safe, lawful, and technically suitable for the intended use. DOW MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW
PRODUCT FOR USE IN MEDICAL APPLICATIONS.
This document is intended for use within Euope, India, Middle East and Africa.
Published January, 2010. Printed in Switzerland.
© 2010 The Dow Chemical Company