Manual de Instalación para El Kit de Controlador Con Cable WK-A

You might also like

Download as pdf
Download as pdf
You are on page 1of 5
This wired controller kit WK-A is required when wall mount type indoor unit needs a installation with wired remote controller YR-E17 or YR-E16B WK-A is current compatible with the following models * AWO9ES2VHA, AW12ES2VHA, AW18ES2VHA, AW24ES2VHA 4.Installation Installation diagram review = Pg ———————_] Ved emote Step 1: This package include the following accessories, 1) Base 2) front cover 3) PCB Board 4) wire cable 3ft Picture 1.1 Paget Haier ‘Step 2: Choose a proper location for installing the kit. Examples are below ( top of The unit or on side of the unit) Picture 1.2 ‘Step3: Open the box cover by sliding the box front cover up. Insert the wires into the bottom hole as shown in picture 1.3. Screw the base to the wall using 3 screws holes on the back plate shown in picture 1.4. Use anchors also to insure that the plate will stay secure to the wall a: Picture 1.3 Picture 1.4 Picture 1.5 Step 4: Using the cable provide connect terminal CN2 of the wall mount unit PCB board and terminal CNS of WK-A Controller Kit. Step 5: Connect the terminals between wired remote (YR-E17 or YR-E16B) and the controller kit. Use the wire that was included with the wired controller. Connect the wire to CN1 on controller kit to CN1 on the back of the wired controller. Attached is the picture 1.6 of YR-E17 for reference. Page? Picture 1.6 ‘Step 6: Please slide the cover to down fo complete the installation 2. Maintenance Part Now the kit is only available for single zone 23SEER advanced series (high wall) to connect with wired remote controller YR-E16B and YR-E17. 2.4 Wire Diagram for Single Zone R: Red G: Green LEDIR LEDAIG [mewrrco ne | WK-A mis LED2IS LeDIRS ono we CNS GNT ON? (ELE Ga ise) Wired controler Picture 2.4 Romark: (1) SW1 Defaut DIP switch: OFF/OFFIOFFIOFF (2) There is a jumper for both torminal CN3 and CNA. 2.2 Wire Diagram for Multi Zone (Master and Slave) The wired remote can connect upto16 indoor units at the same time, but each high wall indoor will need (1) WK-A controller kit. Pages Haier rich wat Cuneo wad cats i ' om mm if @ |e & fe eh Wha (master unit) . yy CN2CNSCN. CNICN2 CN3CN: ICNICN2 CN3CN i ies Be BD Wired controler Picture 2.2 Remark: (1) The first high wall indoor unit to connect with WK-A is considered as master unit 0. (2)There is a jumper between terminal CN3 and CN4 for the master unit, while cut off the terminal forthe slave unit, (3) The terminal CN1 of WK-A for master unit (unit 0) must connect the wired remote (4)Tho terminal CN2 of WK-A for master unit(unit 0) must connect th CN1 of WK-A for slave. ‘nit(unit 1), while there is no limited between the terminal CN2 and CN1 of WK-A forthe next, Ex. the CN2 of WK-A for slave unit 2 can connect the terminal CN2 or CN1 of WK-A for slave unit 3. (®)Please see the attached list for Master/slave DIP switch setting of WK-A. AG Indoor Addross (SW1): 1 234 off off off off :0 (Master defauttP 0000) off off off on : (Stave 1P 0001) and se on fon on on on: 15(Siave IP 1111) UnitNe. | DIP Switch position | Unit No. DIP Switch position (1234) (1234) 0 off off aff off e on off off off 1 ‘of off aff on @ on of aff 2 off off on off 10 ‘on off on off a fff an an 1" ‘on offen on. 4 ff on aff off 2 (non aff off 3 (off on aff on 8 on on etfon. Paget Haier ‘fon on off 1% ‘on 08 an oft ‘aff on an an 6 2.3.Indicator Light ‘The indicator light for single zone and multi zone is same. 2.3.4 LED1 (fed) light,LED2 (green) light is the communication indicator light. It the wired remote and WK-A works in normal, the two lights keep flashing. After installation, the 2 lights will be hidden in the box. 2.3.2 LEDS (red) light is failure indicator, and no lighting in normal operation flash 4 time: communication failure between indoor unit and WK-A. flash 2 times: communication failure between wired remote and WK-A. 2.3.3 LED4 (green) light is operation indicator. LED4 on means the unit works normally. Page 5

You might also like