FMX-PWM™ Sampler

Power Mixing & Sampling Systems


For sampling Hydrocarbons automatically
Features  Highest Accuracy with lowest uncertainty
 Fluimix has developed zero pressure drop mixing measurement of 0.025%.
technology which fully homogenizes Hydrocarbons
so that a representative sample can be taken for  Ideal for Fiscal Transfer points in
analysis. refineries and on Pipelines.

 Fully Homogenizes fluids from 0.4cSt to 8000 cSt.  Homogenises fluids at flow rates, enabling
Refined Products to Heavy Crudes. sampling at all flow rates.

 Options for full Analytical Loop with


BS&W, Densitometer, WIOM meters for
real time analysis

 System shown is Single pump with


Sampling Cabinet. Options for fully
redundant, pumps, motors, Samplers and
analysers.

 Pneumatic or Electrically Operated Cell


Sampler and Switch over valves.

 Full Automatic, can be controlled locally or


via DCS.

 Sampling technology uses the Fluimix API


Sampler and either Atmospheric Receivers or
Constant Pressure Receiver’s (CPC’s) to
produce representative samples for fiscal
transfer.

 Meets ISO 3171, API 8.2 ASTM D 4177.

 Mixing Technology validated at the Cranfield


University In the UK.

FluiMix Ltd, Calverley House, 55 Calverley Road, Tunbridge Wells, TN1 1XP, UK, T: +44 1892 704 058 E: info@fluimix.com
www.fluimix.com
Description
The Fluimix® FMX-PWM™ Hydrocarbon Sampler operation. The short distance travelled by the sample minimises
Flow is extracted from the main pipeline, pressurized and the risk of cross- contamination between batches.
re-injected back into the main pipeline in such a way that it
homogenises the fluid in the main pipeline to such an The enclosure, which can be heated to maintain an even
extent a representative sample can be removed which has temperature to avoid solid or wax formation, also houses the
a representative accuracy of 0.025% of the main pipeline sample receivers. These can be fixed volume 5 liters, 10 liters,
fluid. This is for all flow rates. 18 liters or constant pressure sample receivers (CPC) with manual
or automatic changeover.
Flow is then extracted into the sampling loop which is Dynamic performance measurement can be achieved by fitting
designed to have no water traps and sufficient fluid velocity a Can Weigh system for receivers or a level-sensor system for
to maintain sample representivity and homogeneity CPC receivers. A sampler controller can be installed providing
through the system. The loop passes through a sample configuration, monitoring and control functions with DCS
receiver cabinet which can be located in a convenient integration capability.
position for the operator. The enclosure can be fully Optional withdrawable nozzle and quill can be installed by
isolated so that any maintenance work can be carried out 'hot-tap' into either the top or the bottom of the pipeline.
with no impact on the main process. On-line analysers such as water-in- oil monitors and
densitometers can be integrated as part of the sampling loop
The enclosure contains a flow- through cell sampler which ensuring optimum representivity, accuracy and direct
discharges 1cc samples directly into a sample receiver. comparison of results.

FMX-PWM™ TYPICAL P&ID

It is solely the responsibility of the end-user, through its own analysis and testing, to select products and materials suitable for their specific
application requirements, ensure they are properly installed, safely applied, properly maintained, and limit their use to their intended purpose.
Improper selection, installation, or use may result in personal injury or property damage.

TECH DATA SHEET API-CE 17.04.24 Rev 02

FluiMix Ltd, Calverley House, 55 Calverley Road, Tunbridge Wells, TN1 1XP, UK, T: +44 1892 704 058 E: info@fluimix.com