Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

MEDICAL REFRIGERATORS

Rev. 00 - 11. 2017


technical and stylistic characteristics are subject to be changed without manufactures’s
Should it be necessary of useful without undermining any model essential features,

previous notice. Pictures don’t necessarily show product in standard version.


LABORATORY AND PHARMACY
REFRIGERATOR
BLOOD BANK
REFRIGERATOR
LABORATORY FREEZER
DEEP FREEZER
Fri.med. Srl
Via Riva, 26/19 COMBINED
14021 Buttigliera d’Asti (AT) Italy
Tel. +39 011 9921161 REFRIGERATOR
Fax +39 011 9921160
AND FREEZER
info@frimed.it
www.frimed.it

made in
w
refrigeration field.
as established in 1997,
as result of twenty year experience of its owners in medical

Constant research and development, along with professional


and serious attitude have enabled frimed to design and
manufacture highly reliable refrigerators and freezers to be
used in hospital, laboratory, biomedical and pharmaceutical
fields as well as scientific field in general.
In few years our appliances have become well known and are
now appreciated and chosen in many countries all over the world.
frimed has always been oriented to a constant improvement
of the business process in order to satisfy the client, to involve
its staff and to have a relationship of mutual satisfaction with
suppliers. The commitment undertaken in this direction has enabled
the company to achieve an important goal the certification
of Quality Management System ISO 9001 which is a guarantee
of reliability and professional attitude
Member of CISQ Federation

ISO 9001
Certified Quality System

Further Quality Management System ISO 14001: certification


confirms frimed serious commitment to minimize the environmental
impact of procedures, products and services and attests the
reliability of the Environmental Management System applied.
Member of CISQ Federation

ISO 14001
Certified Environmental System

In 2010 frimed also achieved the certification of Quality


Management System according to ISO 13485 (Medical Devices)
and, at the same time, the CE certification according to Medical
Device Directives 93/42/EEC for the marking of Blood Bank
refrigerators (class IIa) for hospital use.
Member of CISQ Federation

ISO 13485
Medical Devices
Certified Quality System

International
Organization for Medical Device
Directive 93/42/EEC
Standardization
index
product 6
lab and pharmacy refrigerator 14
blood bank refrigerator 20
laboratory freezer 24
laboratory deep freezer 28
plasma freezer 30
combined refrigerator and freezer 34
combined refrigerator 38

made in
energy saving
and enviroment protection technology
LED lighting
All our cabinets with positive temperature are internally equipped with LED lights.
LED lighting is the solution for reducing energy use, because it allows saving energy up to
70% compared with fluorescent lamps. LED lights have high performance, bright colour and
provide beneficial environmental impact with longer life and therefore less landfill waste.

low emissivity glass


This technology applied to all models with glass door significantly improves performance of
insulation allowing energy saving.

CFC-free thermo insulation


Insulation of all cabinets is done by means of ecological CFC-free polyurethane foam.
Thickness of 60mm for all refrigerator models and 80,100 mm for freezer models grants
highly insulating performance.

enviroment friendly refrigerant gasnatural gas R290


CFC- free R404a gas is used in all compressors of frimed models. In addiction we also offer
compressors with natural gas R290 on all our models.

energy saving defrost cycle


In all ventilated refrigerators, defrosting cycles are performed only when necessary.

hot gas defrosting


for ventilated freezer AF70B and AF140B with a very short cycle with no need of electric resistance.

high performance motor


fan granting energy saving thanks to new technology.
Besides, frimed mainboard makes condenser fan work only when necessary.

06 07
technical highlights
structure
External structure in hot-dip galvanised steel, anti-corrosion treated and whte PVC film coated.
Stainless steel internal structure.

insulation
Insulation of 60mm, 80mm, 100mm obtained by injection of high density ecological polyurethane
CFC-free foam for excellent product preservation and best energy saving.

door
Self-closing door with removable magnetic gasket on four sides for perfect closing.
Right hand opening or left hand on request.

lock with key


To use the appliance under supervision. Optional electric digital key lock.

led lighting
LED light with automatic switch at door opening. Manual switch on control panel.

shelves
In Scotch-Brite stainless steel. Adjustable in height.

drawers
Sliding drawers in Scotch-Brite stainless steel. Plexiglas frontal side. Optional plexiglas dividers.

refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air condenser.
Internal ventilated or static evaporator. CFC-free refrigerant.

defrosting
Fully automatic defrosting cycle with auto-evaporation of condensed water,
or manual defrosting cycle.

temperature chart recorder


Weekly temperature recording system working with 1,5V battery.
It is equipped with 52 disks and an ink pen.

castors with frontal brakes

test hole
ø 25 mm sidewall test hole for custom probe.

08 09
control panel
Microprocessor control panel with colour 4.3” LCD touch screen and keys

Setting and visualization with 0.1 resolution

Display showing cabinet temperature, set point, date, hour, equipment model
and electronic accessories

Continuous temperature monitoring temperature


digital display

Real time temperature graph (to be activated by user)

Password protected power switch and settings power control


with password

Digital humidity sensor (optional)

RS232/RS485 ports
visual and acoustic
alarms

Digital calibration of probes

In/out 4-20 mA converter module


back-up battery

Safety thermostat

Two independent PT1000 probes, the first one to set and detect temperature, the other
one to manage the alarm system and display temperature
remote contact
for alarm

Visual and audible alarms through buzzer sound, general alarm warning light and specific
alarm warning icon on display.
Alarms of high and low temperature, open door, condenser efficiency, damaged probes,
power failure at electricity recovery, power failure with recording of data and alarms generated gsm alarm

by back-up battery (standard only on blood bank refrigerator and plasma freezer),
damaged or flat battery
Memory of latest alarms shown on display

Back-up Battery to show temperature on display and to manage the alarm system in case lan port

of power failure

Remote contact (dry, volt-free) to connect the equipment to an external alarm


usb port

GSM module to send SMS alarms messages to mobile phones showing date, time, cabinet
temperature and type of alarm. Possibility to send SMS messages from mobile phone to
check correct functioning of equipment

LAN port to connect one or more appliances via Ethernet on PC to monitor working state
data logger

USB port to download temperature data and alarms and to upgrade or reset the appliance

Data logger to record temperatures and alarms. Download data on USB pen drive

10 11
SHU air purifier
A revolution in air sanitization and purification of your refrigerator.
The technology used by SHU quickly and effectively attacks and destroys micro-organisms which
are harmful to humans (mould, bacteria, viruses, odours and volatile organic compounds) by taking
advantage of extraordinary biochemical processes.
Shu air purifier is the only one currently on the market using “state-of-the-art” technology.This is the
latest and most advanced technology which is used in NASA aerospace stations.
This system, active 24 hours a day, is capable already in the first 90 minutes of use, of eliminating more
than 95% of viruses, bacteria and mould in the environment.

how shu works

The germicidal UV lamp destroys germs that pass through the UVC light rays.
The rays of light from the UV lamp react with the nano Nickel HCT ™ catalyst producing catalytic
molecules. The catalytic molecules detect and destroy the carbon-based molecules by converting
them into harmless carbon dioxide and water.
Unlike other purification systems on the market, SHU is not limited to purifying the air that passes
through the catalyst, but also emits a thick layer of molecules into the air (ROS Reactive Oxygen Species)
that purifies the air throughout the whole environment.

shu, via ahpco technology,produces a layer of hydroxide ions, radicals, radical peroxides, hydro peroxides
which through the action of light and air humidity, triggers a reaction of decomposition of organic and
inorganic substances: only the oxygen and hydrogen molecules remain in the air. It is an absolutely
natural phenomenon similar to what occurs during a storm: the air is purified.

shu eliminates in real time...

Salmonella enterica
Staphylococcus aureus
Resistant strains of Staphylococcus aureus:
Methicillin resistant (MRSA) and CA-MRSA /
PVL-MRSA
Vancomycin resistant Enterococcus (VRE)
Listeria monocytogenes
Escherichia coli (E. coli O157: H7)
Campylobacter jejuni
Acinetobacter baumannii
HIV 1
Influenza A
Avian Influenza
H1N1 (Human and Swine)
Herpes Simplex Type 1
Polio Type 2
Norovirus and Murine Norovirus
Rhinovirus

12 13
REFRIGERATOR
LABORATORY AND PHARMACY
+2°+12°C from 100 to 1400 lt.

SB-FS-PN-AF models
structure
External structure in hot-dip galvanised steel, anti-corrosion treated and PVC
film coated. Stainless steel internal structure.
insulation
60 mm of insulation obtained by injection of high density ecological polyurethane CFC-free
foam for excellent product preservation and energy saving.
door
Self-closing solid or glass door (double insulating - low emissivity glass) with folding
magnetic gasket (easy to replace) on four sides for perfect closing.
Right hand opening or left hand on request. Lock with key.
shelves
Scotch-Brite stainless steel shelves, removable and adjustable in height.
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening.
Manual switch on control panel.
temperature range
Between +2°C and +12°C. Factory preset to +4°C.
Digital adjustable with an increment of 0.1°C
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser (suitable also for tropical countries). Forced-air cooling system conceived
to achieve maximum temperature uniformity and stability inside the refrigerator even
in case of frequent door openings. Evaporator fan shuts off during door opening.
CFC-free refrigerant R404a or CFC/HCFC-free natural refrigerant R290 on request.
defrosting standard optional accessories
Fully automatic defrosting cycle and auto-evaporation of condensed water. • Shelves • Scotch-Brite stainless steel sliding drawers with
• Four one-way wheels with stabilizing adjustable feet telescopic ball-bearing slides. Plexiglas frontal side
control panel and alarms
Microprocessor control panel with colour 4.3” LCD touch screen and keys. • Power cord with Schüko type plug or British type plug • Kit of dividers for drawer
• Protection fuses (on power switch and electronic mainboard) • Additional shelf
Display with 0.1°C resolution. Temperature monitoring detected by two independent • RFI filter • Smooth shelf with borders
PT1000 probes. Real time temperature graph (to be activated by user). • Password protected power switch and settings • Castors with frontal brakes
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. • Electronic control panel with alarm system • Weekly temperature chart recorder
Visual and audible alarms of high and low temperature (by means of independent probe), • Remote contact (dry, volt-free) for alarm • Back-up battery
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Data Logger with USB port • GSM alarm to send SMS alarm messages
• Memory of latest alarms visible on screen to mobile phones
power failure with recording of data and alarms (by means of optional back-up battery), • Power failure at electricity recovery • LAN port to connect the appliance via ethernet on PC
damaged or flat battery. Memory of latest alarms visible on display. • Safety thermostat
data logger • Digital humidity sensor
To record temperatures and alarms. Download data on USB pen drive. Medical Device • Test hole (Ø 25 mm)
Directive 93/42/EEC
• DIN 58345 conformity
• Electric digital key lock
• Power supply 115V/60Hz

14 15
MODEL SB10
MODEL SB10V
SB10 FS15
SB10V FS15V
FS15 FS20
FS15V FS20V
FS20 FS25
FS20V FS25V
FS25 FS30
FS25V FS30V
FS30 FS30V
TECHNICAL DATA TECHNICAL DATA

Capacity (LT) Capacity


100(LT) 100100 150100 150150 200 150 200200 250 200 250 250 300
250 300300 300
Temp. range (°C) Temp.
+2range
/ +12 (°C) +2 /+2
+12/ +12 +2 /+2
+12
/ +12 +2 / +2
+12/ +12 +2 /+2
+12
/ +12 +2 /+2
+12
/ +12 +2 /+2
+12
/ +12 +2 / +2
+12/ +12 +2 +2
/ +12
/ +12 +2 /+2
+12
/ +12 +2 / +12
Cooling type Cooling
Forced air
type
cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air coolingForced
Forced
air cooling
air coolingForced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air coolingForced
Forced
air cooling
air cooling Forced
Forced
air air
cooling
cooling Forced air cooling
Defrost Defrost
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
CFC-Free Refrigerant gas CFC-
R404a
Free or R290 gas
Refrigerant R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or or
R290
R290 R404a or R290
Noise level (db) Noise level
<45 (db) <45<45 <45<45 <45<45 <45<45 <45<45 <49<45 <49 <49 <49<49 <49<49 <49

LCD TOUCH 4.3'' LCD TOUCH 4.3'' 4.3''


LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''
CONTROL PANEL CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR

VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS

specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS

Password protected use Password


√ protected use √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Remote alarm Remote√alarm √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Data logger Data logger
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Humidity probe Humidity
optional
probe optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
RS232-RS485 serial port RS232-RS485
√ serial port √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
4-20 mA converter module 4-20 mA√converter module √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Safety thermostat Safety
optional
thermostat optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
ELECTRICAL DATA ELECTRICAL DATA

Supply voltage (V/Hz) Supply


230/50-230/60
voltage (V/Hz) 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
Max absorbed current (W) Max absorbed
245 current (W) 245245 245 245 245245 245245 245245 360245 360360 360360 360360 360
INTERNAL EQUIPMENT INTERNAL EQUIPMENT

Shelves Shelves2 2 2 2 2 2 2 3 2 3 3 4 3 4 4 5 4 5 5 5
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES

Drawer Drawer
max 2 max
max
2 2 maxmax
3 2 max
max
3 3 max
max
4 3 maxmax
4 4 max max
5 4 maxmax
5 5 max
max6 5 max
max
6 6 max 6
Kit of dividers for drawer Kit of dividers
√ for drawer √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Additional shelf Additional
√ shelf √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Shelf with border Shelf with
√ border √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Temp.chart recorder Temp.chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up √battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

GSM module GSM module


√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
LAN Port LAN Port√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Port hole Port hole√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Electric Digital key lock Electric Digital
√ key lock √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power supply 115V/60Hz Power supply
√ 115V/60Hz √ √ √ √ √ √ √ √ √ √ √ √ √ √ v √ v v v
CERTIFICATION CERTIFICATIONCE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE

DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG

External Dimensions/weight 600x600x860-57


External Dimensions/weight 600x600x860-60
600x600x860-57 600x600x1360-73
600x600x860-60 600x600x1360-78
600x600x1360-73600x600x1560-82
600x600x1360-78600x600x1560-86
600x600x1560-82 600x600x1760-88
600x600x1560-86600x600x1560-93
600x600x1760-88600x600x1960-97
600x600x1560-93600x600x1960-102
600x600x1960-97 600x600x1960-102
Packing Dimensions/weight Packing Dimensions/weight
(carton box) 700x700x1030-63
(carton box) 700x700x1030-66
700x700x1030-63700x700x1570-80
700x700x1030-66700x700x1570-85
700x700x1570-80700x700x1770-89
700x700x1570-85700x700x1770-93
700x700x1770-89700x700x1890-98
700x700x1770-93700x700x1890-103
700x700x1890-98700x700x2170-107
700x700x1890-103
700x700x2170-112
700x700x2170-107 700x700x2170-112

16 17
MODEL PN45
MODEL PN45V
PN45 PN52
PN45V PN52V
PN52 AF70
PN52V AF70V
AF70 AF140
AF70V AF140V
AF140 AF140V
TECHNICAL DATA TECHNICAL DATA

Capacity (LT) Capacity


450(LT) 450450 520450 520520 700 520 700700 1400
700 14001400 1400
Temp. range (°C) Temp.
+2range
/ +12 (°C) +2 /+2
+12/ +12 +2 /+2
+12
/ +12 +2 / +2
+12/ +12 +2 /+2
+12
/ +12 +2 /+2
+12
/ +12 +2 /+2
+12
/ +12 +2 / +2
+12/ +12 +2 / +12
Cooling type Cooling
Forced air
type
cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air coolingForced
Forced
air cooling
air coolingForced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced air cooling
Defrost Defrost
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
CFC-Free Refrigerant gas CFC-
R404a
Free or R290 gas
Refrigerant R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a or R290
Noise level (db) Noise level
<49 (db) <49<49 <49<49 <49<49 <49<49 <49<49 <50<49 <50 <50 <50

LCD TOUCH 4.3'' LCD TOUCH 4.3'' 4.3''


LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''
CONTROL PANEL CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR

VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS

specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS

Password protected use Password


√ protected use √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Remote alarm Remote√alarm √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Data logger Data logger
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Humidity probe Humidity
optional
probe optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
RS232-RS485 serial port RS232-RS485
√ serial port √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
4-20 mA converter module 4-20 mA√converter module √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Safety thermostat Safety
optional
thermostat optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
ELECTRICAL DATA ELECTRICAL DATA

Supply voltage (V/Hz) Supply


230/50-230/60
voltage (V/Hz) 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
Max absorbed current (W) Max absorbed
336 current (W) 336
336 336 336 336336 260336 260260 490 260 490490 490
INTERNAL EQUIPMENT INTERNAL EQUIPMENT

Shelves Shelves3 3 3 4 3 4 4 4 4 4 4 8 4 8 8 8
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES

Drawer Drawer
max 5 max
max
5 5 maxmax
6 5 max
max
6 6 max
max
7 6 maxmax
7 7 maxmax
14 7 maxmax
14 14 max 14
Kit of dividers for drawer Kit of dividers
√ for drawer √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Additional shelf Additional
√ shelf √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Shelf with border Shelf with
√ border √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Temp.chart recorder Temp.chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up √battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

GSM module GSM module


√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
LAN Port LAN Port√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Port hole Port hole√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Electric Digital key lock Electric Digital
√ key lock √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power supply 115V/60Hz Power supply
√ 115V/60Hz √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
CERTIFICATION CERTIFICATIONCE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE

DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG

External Dimensions/weight 700x800x1840-120


External Dimensions/weight700x800x1840-124
700x800x1840-120
700x800x2040-134
700x800x1840-124700x800x2040-138
700x800x2040-134700x800x1990-137
700x800x2040-138
700x800x1990-142
700x800x1990-137
1400x800x1990-216
700x800x1990-142
1400x800x1990-226
1400x800x1990-216 1400x800x1990-226
Packing Dimensions/weight Packing Dimensions/weight
(carton box) 750x850x1980-130
(carton box) 750x850x1980-134
750x850x1980-130
750x850x2180-144
750x850x1980-134750x850x2150-148
750x850x2180-144750x850x2150-152
750x850x2150-148
750x850x2150-167
750x850x2150-152
1500x900x2170-236
750x850x2150-167
1500x900x2170-246
1500x900x2170-236 1500x900x2170-246

18 19
BLOOD BANK REFRIGERATOR
FROM 64 TO 770 BLOOD BAGS (450 ml/each)
+2°+6°C from 100 to 1400 lt.

SB-FS-PN-AF models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation obtained by injection of high density ecological polyurethane CFC-free
foam for excellent product preservation and energy saving.
door
Self-closing glass door (double insulating – low emissivity glass) with folding magnetic gasket
(easy to replace) on four sides for perfect closing. Right hand opening or left hand on request.
Lock with key.
drawers
Scotch-Brite stainless steel drawers with telescopic ball-bearing slides and plexiglas
frontal side. Optional plexiglas internal dividers.
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening.
Manual switch on control panel.
temperature range
Between +2°C and +6°C. Factory preset to +4°C. Digital adjustable with an increment of 0.1°C
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air condenser
(suitable also for tropical countries). Forced-air cooling system conceived to achieve maximum
temperature uniformity and stability inside the refrigerator even in case of frequent door
openings. Evaporator fan shuts off during door opening. CFC-free refrigerant R404a
or CFC/HCFC-free natural refrigerant R290 on request.
defrosting certification
Fully automatic defrosting cycle and auto-evaporation of condensed water. Certified in accordance with Medical Device Directive 93/42/EEC
control panel and alarms class IIa for storage and preservation of blood.
Microprocessor control panel with colour 4.3” LCD touch screen and keys.
Display with 0.1°C resolution. Temperature monitoring detected by two independent PT1000 0476
probes. Real time temperature graph (to be activated by user). Optional humidity sensor.
RS232/RS 485 port. Digital calibration of probe.
standard optional accessories
Visual and audible alarms of high and low temperature (by means of independent probe),
open door, condenser efficiency, damaged probes, power failure with recording of data and • Drawers • Kit of dividers for drawer
• Four one-way wheels with stabilizing adjustable feet • Castors with frontal brakes
alarms (by means of back-up battery), damaged or flat battery. Memory of latest alarms • Power cord with Schüko type plug or British type plug • GSM alarm to send SMS alarm messages
visible on display • Protection fuses (on power switch and electronic mainboard) to mobile phones
data logger • RFI filter • LAN port
To record temperatures and alarms. Download data on USB pen drive. • Password protected power switch and settings to connect the appliance via ethernet on PC
back-up battery
• Electronic control panel with alarm system • Digital humidity sensor
• Safety thermostat • Test hole (Ø 25 mm)
Self-powered back-up battery supplying electric power to control panel in order to • Weekly temperature chart recorder • Electric digital key lock
generate alarms in case of power failure. • Back-up battery • Power supply 115V/60Hz
temperature chart recorder • Remote contact (dry, volt-free) for alarm
Weekly temperature recording system working with 1,5V battery. It is equipped with 52 • Data Logger with USB port
paper disks and an ink pen. • Memory of latest alarms visible on screen
• DIN 58371 conformity
20 21
MODEL SB10E
MODEL FS15E
SB10E FS20E
FS15E FS25E
FS20E FS30E
FS25E PN45E
FS30E PN52E
PN45E AF70E
PN52E AF140E
AF70E AF140E
TECHNICAL DATA TECHNICAL DATA

Capacity (LT) Capacity


100
(LT) 150100 200150 250200 300250 450300 520450 700 520 1400
700 1400
Blood bags (450 ml/each) Blood bags
64 (450 ml/each) 96 64 128 96 160128 192160 275192 330275 385 330 770
385 770
Temp. range (°C) Temp.
+2range
/ +6 (°C) +2 +2
/ +6/ +6 +2 /+2
+6/ +6 +2 +2
/ +6/ +6 +2 /+2
+6/ +6 +2 +2
/ +6/ +6 +2 /+2
+6/ +6 2 / +2
+6 / +6 2 / 2+6/ +6 2 / +6
Cooling type Cooling
Forced air
type
cooling Forced
Forced
air cooling
air cooling Forced
Forced
air air
cooling
cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced
Forced
air air
cooling
cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air cooling Forced air cooling
Defrost Defrost
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
CFC-Free Refrigerant gas CFC-
R404a or R290 gas
Free Refrigerant R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a or R290
Noise level (db) Noise level
<45 (db) <45<45 <45<45 <49<45 <49
<49 <49<49 <49<49 <49 <49 <50<49 <50

LCD TOUCH 4.3'' LCD TOUCH 4.3''4.3''


LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD LCD
TOUCH 4.3''4.3''
TOUCH LCD TOUCH 4.3''
CONTROL PANEL CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR

VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS

specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power failure Power failure
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS

Password protected use Password√ protected use √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √


Remote alarm Remote √alarm √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Data logger Data logger
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Humidity probe Humidity
optional
probe optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
RS232-RS485 serial port RS232-RS485
√ serial port √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
4-20 mA converter module 4-20 mA√converter module √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Safety thermostat Safety thermostat
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
ELECTRICAL DATA ELECTRICAL DATA

Supply voltage (V/Hz) Supply


230/50-230/60
voltage (V/Hz) 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
Max absorbed current (W) Max absorbed
245 current (W) 245245 245245 360245 360360 336360 336336 260336 490260 490
INTERNAL EQUIPMENT INTERNAL EQUIPMENT

Drawers Drawers2 3 2 4 3 5 4 6 5 5 6 6 5 7 6 14 7 14
Temp. chart recorder Temp. chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up√battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES

Kit of dividers for drawer Kit of dividers


√ for drawer √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
GSM module GSM module
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
LAN Port LAN Port√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Port hole Port hole√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Electric Digital key lock Electric Digital
√ key lock √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power supply 115V/60Hz Power supply
√ 115V/60Hz √ √ √ √ √ √ √ √ √ √ √ √ √ √ v √ v

CERTIFICATION CERTIFICATION
MEDICAL DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL DEVICE
93/42 CLASS IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42 CLASS IIA
DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG

External Dimensions/weight 600x600x860-68


External Dimensions/weight 600x600x1360-89
600x600x860-68 600x600x1560-94
600x600x1360-89600x600x1760-106
600x600x1560-94600x600x1960-118
600x600x1760-106700x800x1840-133
600x600x1960-118
700x800x2040-142
700x800x1840-133700x800x1990-146
700x800x2040-142
1400x800x1990-194
700x800x1990-146 1400x800x1990-194
Packing Dimensions/weigh Packing Dimensions/weigh
(carton box) 680x680x1030-75
(carton box) 700x700x1570-97
680x680x1030-75700x700x1770-105
700x700x1570-97700x700x1890-119
700x700x1770-105700x700x2130-131
700x700x1890-119750x850x1980-163
700x700x2130-131
750x850x2180-9182
750x850x1980-163750x850x2150-205
750x850x2180-9182
1500x900x2170-340
750x850x2150-205 1500x900x2170-340

22 23
FREEZER
LABORATORY
-25°-30° from 100 to 1400 lt.

SB-CV -AF models


structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation on SB-AF models and 80 mm insulation on CV models obtained by
injection of high density ecological polyurethane CFC-free foam for excellent product
preservation and energy saving.
door
Self-closing solid door with folding magnetic gasket (easy to replace) on four sides for
perfect closing. Right hand opening or left hand on request. Lock with key.
shelves/drawers
SB-CV models standard equipped with either Scotch-Brite stainless steel shelves, removable
and adjustable in height or Scotch-Brite stainless steel drawers with telescopic ball-bearing
slides and plexiglas frontal side. AF models standard equipped with Scotch-Brite stainless
steel shelves, removable and adjustable in height.
temperature range
Between -10°C and -25°C. Factory preset to -22°C (SB-AF models).
Between -10°C and -32°C. Factory preset to -30°C (CV and AF-SB special models).
Digital adjustable temperature with an increment of 0.1°C.
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser. Static evaporator for SB-CV models. Forced-air cooling system for AF models
conceived to achieve maximum temperature uniformity and stability inside the refrigerator
even in case of frequent door openings. Evaporator fan shuts off during door opening.
CFC-free refrigerant R404a or CFC/HCFC-free natural refrigerant R290 on request.
defrosting
Manual defrost on SB-CV models. Fully automatic defrosting cycle and auto-evaporation standard optional accessories
of condensed water on AF models • Shelves or drawers (SB-CV models). • Scotch-Brite stainless steel sliding drawers with telescopic
Shelves on AF models. ball-bearing slides and plexiglas frontal side(AF models).
control panel and alarms
• Four one-way wheels with stabilizing adjustable feet • Kit of dividers for drawer
Microprocessor control panel with colour 4.3” LCD touch screen and keys. Display with • Power cord with Schüko type plug or British type plug • Additional shelf
0.1°C resolution. Temperature monitoring detected by two independent PT1000 probes. • Protection fuses • Smooth shelf with borders
Real time temperature graph (to be activated by user). Optional humidity sensor. (on power switch and electronic mainboard) • Castors with frontal brakes
RS232/RS 485 port. Digital calibration of probe. • RFI filter • Weekly temperature chart recorder
Visual and audible alarms of high and low temperature (by means of independent probe), • Password protected power switch and settings • Back-up battery
• Electronic control panel with alarm system • GSM alarm to send SMS alarm messages to mobile phones
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Remote contact (dry, volt-free) for alarm • LAN port to connect the appliance via ethernet on PC
power failure with recording of data and alarms (by means of optional back-up battery), • Data Logger with USB port • Safety thermostat
damaged or flat battery. Memory of latest alarms visible on display. • Memory of latest alarms visible on screen • Digital humidity sensor
data logger • Test hole (Ø 25 mm)
To record temperatures and alarms. Download data on USB pen drive. • Electric digital key lock
Medical Device
Directive 93/42/EEC • Power supply 115V/60Hz

24 25
MODEL SB10B
MODEL SB10B
SB10B
special CV3
SB10Bspecial CV4
CV3 CV5
CV4 CV6
CV5 AF70B
CV6 AF70B
AF70B
special AF140B
AF70Bspecial AF140B
AF140B
special AF140Bspecial
TECHNICAL DATA TECHNICAL DATA

Capacity (LT) Capacity


100(LT) 100100 160100 220160 250220 320250 700320 700700 1400700 14001400 1400
Factory set (°C) Factory -22
set (°C) -30-22 -30 -30 -30 -30 -30 -30 -30-30 -22 -30 -30-22 -22 -30 -30-22 -30
Temp. range (°C) Temp.
-10range
/ -25 (°C) -10-10
/ -32
/ -25 -10 -10
/ -32/ -32 -10 -10
/ -32/ -32 -10 -10
/ -32/ -32 -10-10
/ -32
/ -32 -10 -10
/ -25/ -32 -10-10
/ -32
/ -25 -10 -10
/ -25/ -32 -10 /-10
-32/ -25 -10 / -32
Cooling type Cooling
Static evaporator
type Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Forced
Static
airevaporator
cooling Forced
Forced
air cooling
air cooling Forced
Forced
air cooling
air coolingForced
Forced
air cooling
air cooling Forced air cooling
Defrost Defrost
Manual Manual
Manual Manual
Manual Manual
Manual Manual
Manual Manual
Manual Automatic
Manual Automatic
Automatic Automatic
Automatic Automatic
Automatic Automatic
CFC-Free Refrigerant gas CFC-
R404a or R290 gas
Free Refrigerant R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a or R290
Noise level (db) Noise level
<45 (db) <45<45 <45<45 <45<45 <45<45 <45<45 <50<45 <50 <50 <60<50 <60<60 <60

LCD TOUCH 4.3'' LCD TOUCH 4.3''4.3''


LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3''4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD LCD
TOUCH 4.3''4.3''
TOUCH LCD TOUCH 4.3'' 4.3''
LCD TOUCH LCD TOUCH 4.3''
CONTROL PANEL CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR

VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS

specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ v √ v
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS

Password protected use Password


√ protected use √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Remote alarm Remote √alarm √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Data logger Data logger
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Humidity probe Humidity
optional
probe optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
RS232-RS485 serial port RS232-RS485
√ serial port √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
4-20 mA converter module 4-20 mA√converter module √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Safety thermostat Safety
optional
thermostat optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
ELECTRICAL DATA ELECTRICAL DATA

Supply voltage (V/Hz) Supply


230/50-230/60
voltage (V/Hz) 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
Max absorbed current (W) Max absorbed
345 current (W) 345345 450 345 450450 450450 450450 530450 887530 614887 1084614 1084
INTERNAL EQUIPMENT INTERNAL EQUIPMENT

Drawers Drawers2 2 2 3 2 4 3 5 4 6 5 optional6 optional


optional optional
optional optional
optional optional
in alternative in alternative
Shelves Shelves 2 2 2 3 2 4 3 5 4 6 5 4 6 4 4 8 4 8 8 8
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES

Kit of dividers for drawer Kit of dividers


√ for drawer √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Temp. chart recorder Temp. chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up √
battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
GSM module GSM module
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
LAN Port LAN Port√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Port hole Port hole√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Electric Digital key lock Electric Digital
√ key lock √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power supply 115V/60Hz Power supply
√ 115V/60Hz √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
CERTIFICATION CERTIFICATIONCE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE

DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG

External Dimensions/weight 600x600x860-66


External Dimensions/weight 600x600x860-66
600x600x860-66 640x620x1400-95
600x600x860-66 640x620x1600-111
640x620x1400-95640x620x1800-125
640x620x1600-111
640x620x2000-136
640x620x1800-125
700x800x1990-141
640x620x2000-136
700x800x1990-141
700x800x1990-141
1400x800x1990-229
700x800x1990-141
1400x800x1990-229
1400x800x1990-229 1400x800x1990-229
Packing Dimensions/weight Packing Dimensions/weight
(carton box) 700x700x1030-73
(carton box) 700x700x1030-73
700x700x1030-73700x700x1530-105
700x700x1030-73700x700x1780-121
700x700x1530-105700x700x1930-135
700x700x1780-121700x700x2130-146
700x700x1930-135
750x850x2150-151
700x700x2130-146
750x850x2150-151
750x850x2150-151
1500x900x2170-249
750x850x2150-151
1500x900x2170-249
1500x900x2170-249 1500x900x2170-249

26 27
DEEP FREEZER
LABORATORY
-40° from 300 to 600 lt.

CL models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
100mm insulation obtained by injection of high density ecological polyurethane CFC-
free foam for excellent product preservation and energy saving.
door
Self-closing solid door with two folding magnetic gaskets (easy to replace) on four sides for
perfect closing. Right hand opening or left hand on request. Optional electric digital key lock.
shelves/drawers
Standard equipped with either Scotch-Brite stainless steel shelves, removable and
adjustable in height or Scotch-Brite stainless steel drawers with telescopic ball-bearing
slides and plexiglas frontal side.
temperature range
Between -10°C and -42°C. Factory preset to -40°C. Digital adjustable temperature
with an increment of 0.1°C.
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser. Static evaporator. CFC-free refrigerant R404a or CFC/HCFC-free natural
refrigerant R290 on request.
defrosting
Manual defrosting cycle.
control panel and alarms
Microprocessor control panel with colour 4.3” LCD touch screen and keys. Display with
0.1°C resolution. Temperature monitoring detected by two independent PT1000 probes.
Real time temperature graph (to be activated by user).
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. standard optional accessories
Visual and audible alarms of high and low temperature (by means of independent probe), • Shelves or drawers • Kit of dividers for drawer
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Four one-way wheels with stabilizing adjustable feet • Additional shelf
power failure with recording of data and alarms (by means of optional back-up battery), • Power cord with Schüko type plug or British type plug • Smooth shelf with borders
damaged or flat battery. Memory of latest alarms visible on display • Protection fuses • Castors with frontal brakes
(on power switch and electronic mainboard) • Weekly temperature chart recorder
data logger
• RFI filter • Back-up battery
To record temperatures and alarms. Download data on USB pen drive. • Password protected power switch and settings • GSM alarm to send SMS alarm messages to mobile phones
• Electronic control panel with alarm system • LAN port to connect the appliance via ethernet on PC
• Remote contact (dry, volt-free) for alarm • Safety thermostat
• Data Logger with USB port • Digital humidity sensor
• Memory of latest alarms visible on screen • Test hole (Ø 25 mm)
• Power failure at electricity recovery • Electric digital key lock
• Power supply 115V/60Hz
Medical Device
Directive 93/42/EEC

28 29
PLASMA FREEZER
-40° 600 lt.

CL60B/PF model
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
100mm insulation obtained by injection of high density ecological polyurethane CFC-
free foam for excellent product preservation and energy saving.
door
Self-closing solid door with two folding magnetic gaskets (easy to replace) on four sides for
perfect closing. Right hand opening or left hand on request. Optional electric digital
key lock.
drawers
Standard equipped with 6 Scotch-Brite stainless steel drawers with telescopic ball-
bearing slides and plexiglas frontal side. Optional kit of Plexiglas dividers for drawer.
temperature range
Between -30°C and -42°C. Factory preset to -40°C. Digital adjustable temperature
with an increment of 0.1°C.
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser. Static evaporator. CFC-free refrigerant R404a or CFC/HCFC-free natural
refrigerant R290 on request.
defrosting
Manual defrosting cycle. certification
control panel and alarms Certified in accordance with Medical Device Directive 93/42/EEC
Microprocessor control panel with colour 4.3” LCD touch screen and keys. class IIa for storage and preservation of plasma.
Display with 0.1°C resolution. Temperature monitoring detected by two independent
PT1000 probes. Real time temperature graph (to be activated by user). 0476
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe.
Visual and audible alarms of high and low temperature (by means of independent probe),
open door, condenser efficiency, damaged probes, power failure with recording of data
standard optional accessories
and alarms (by means of back-up battery), damaged or flat battery. Memory of latest • Drawers • Kit of dividers for drawer
• Four one-way wheels with stabilizing adjustable feet • Castors with frontal brakes
alarms visible on display. • Power cord with Schüko type plug or British type plug • GSM alarm to send SMS alarm messages to mobile phones
data logger • Protection fuses • LAN port to connect the appliance via ethernet on PC
To record temperatures and alarms of last 30 days. Download data on USB pen drive. (on power switch and electronic mainboard) • Digital humidity sensor
back-up battery • RFI filter • Test hole (Ø 25 mm)
Self-powered back-up battery supplying electric power to control panel in order to • Password protected power switch and settings • Electric digital key lock
• Electronic control panel with alarm system • Power supply 115V/60Hz
generate alarms in case of power failure. • Remote contact (dry, volt-free) for alarm
temperature chart recorder • Weekly temperature chart recorder
Weekly temperature recording system working with 1,5V battery. It is equipped with 52 • Back-up battery
paper disks and an ink pen. • Remote contact (dry, volt-free) for alarm
• Data Logger with USB port
• Memory of latest alarms visible on screen
• DIN 58375 conformity
30 31
MODEL CL30B
MODEL CL60B
CL30B CL60B/PF
CL60B CL60B/PF
CL60B/2
MODEL CL60B/2
CL30B CL60B
MODEL CL60B/PF
CL30B CL60B/2
CL60B CL60B/PF CL60B/2
TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA

Capacity (LT) Capacity (LT)


300 300
600 600
600 Capacity
300/300
600 (LT) 300/300300 Capacity (LT)
600 300
600 300/300
600 600 300/300
Factory set Factory set-40 -40
-40 -40
-40 Factory
-40
-40
/ -40
set -40 / -40-40 Factory set -40 -40 -40
-40
/ -40 -40 -40 / -40
Temp. range (°C) Temp. range
-15 / -42
(°C) -15 / -42 -15 / -42 Temp.
-15 range (°C)
-15//-42
-42 -15 / -42
-15 / -42 -15 / -42
Temp. range (°C) -15
-15/ /-42
-42 -15
-15 // -42
-42 -15 / -42 -15 / -42
Cooling type Cooling
Statictype
evaporator Static
Static evaporator
evaporator Static
Staticevaporator
evaporator Cooling
Static
Static type
evaporator
evaporator StaticStatic evaporator Cooling
evaporator Static evaporator
type Static evaporator
Static evaporator Staticevaporator
Static evaporator Static evaporator Static evaporator
Defrost Defrost Manual Manual Manual
Manual Defrost
Manual Manual
Manual Defrost Manual Manual
Manual Manual
Manual Manual Manual
CFC-Free Refrigerant gas CFC-R404a or R290
Free Refrigerant gas R404a or R290 R404a
R404aor
orR290
R290 CFC-Free
R404a
R404a or
or R290
R290
Refrigerant gas R404aR404a
or R290
or R290 CFC-Free
R404a or R290
Refrigerant gas R404a
R404a or
or R290
R290 R404a
R404aor
orR290
R290 R404a or R290 R404a or R290
Noise level (db) Noise level<52
(db) <52
<52 <52
<52 Noise
<52
<52level (db) <52 <52 Noise level<52
(db) <52 <52
<52 <52 <52

TOUCH 4.3'' TOUCH 4.3''


4.3'' TOUCH4.3''
4.3'' TOUCH4.3''
4.3'' LCD4.3''
TOUCH 4.3'' LCD TOUCH 4.3'' LCD TOUCH 4.3'' TOUCH4.3''
4.3'' LCD TOUCH 4.3'' LCD TOUCH 4.3''
CONTROL PANEL CONTROL LCD
PANEL
MICROPROCESSOR
LCD
LCD TOUCH
MICROPROCESSOR
MICROPROCESSOR
LCD
LCDTOUCH
MICROPROCESSOR
MICROPROCESSOR
LCD
LCDTOUCH
CONTROL PANEL
MICROPROCESSOR
LCD TOUCH
MICROPROCESSOR
MICROPROCESSOR
CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
LCD
LCDTOUCH
MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR MICROPROCESSOR

VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS

specifications
High/Low temperature High/Low temperature
√ √ √√ High/Low
√ temperature √ √ High/Low temperature
√ √√ √ √ √
Open door Open door√ √ √√ Open√ door √ √ Open door √ √√ √ √ √
Condenser efficiency Condenser efficiency
√ √ √√ Condenser
√ efficiency √ √ √
Condenser efficiency √√ √ √ √
Damaged sensor Damaged sensor
√ √ √√ Damaged
√ sensor √ √ √
Damaged sensor √√ √ √ √
Power failure Power failure
optional optional
optional optional
√ Power√ failure
optional optional
optional optional
Power failure optional
√ optional
optional √ optional
Full recording memory Full recording √
memory √ √√ Full recording
√ memory √ √ Full recording memory
√ √√ √ √ √
SMS alarm message SMS alarm
optional
message optional
optional optional SMS
optional
optional
alarm message optional
optional SMS alarm
optional
message optional
optional optional
optional optional optional
FUNCTIONS FUNCTIONS FUNCTIONS FUNCTIONS

Password protected use Password protected


√ use √ √√ Password
√ protected use √ √ Password protected
√ use √√ √ √ √
Remote alarm Remote alarm
√ √ √√ Remote
√ alarm √ √ √
Remote alarm √√ √ √ √
Data logger Data logger√ √ √√ Data√logger √ √ Data logger √ √√ √ √ √
Humidity probe Humidity
optional
probe optional optional
optional Humidity
optionalprobe optional
optional Humidityoptional
probe optional
optional optional
optional optional optional
RS232-RS485 serial port RS232-RS485
√ serial port √ √√ RS232-RS485
√ serial port √ √ RS232-RS485
√ serial port √√ √ √ √
4-20 mA converter module4-20 mA converter
√ module √ √√ 4-20 √mA converter module √ √ 4-20 mA converter
√ module √√ √ √ √
Safety thermostat Safety thermostat
optional optional
optional optional
√ Safety
optional
√ thermostat optional
optional Safety thermostat
optional optional
√ optional
optional √ optional
ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA

Supply voltage (V/Hz) Supply


230/50-230/60
voltage (V/Hz) 230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60
Supply voltage (V/Hz)
230/50-230/60
230/50-230/60 Supply230/50-230/60
voltage (V/Hz) 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60 230/50-230/60
Max absorbed current (W) Max absorbed
520
current (W) 580
520 580
580 Max
450/450
580
absorbed current (W) 450/450 520 Max absorbed
580
current (W) 580
520 450/450
580 580 450/450
INTERNAL EQUIPMENT INTERNAL EQUIPMENT INTERNAL EQUIPMENT INTERNAL EQUIPMENT

Drawers Drawers 6 6 66 Drawers


3/3
6 3/3 6 Drawers 6 6 3/3
6 6 3/3
in alternative in alternative in alternative in alternative
Shelves Shelves 6 6 66 Shelves
3/3
6 3/3 6 Shelves 6 6 3/3
6 6 3/3
Temp.chart recorder Temp.chart
optional
recorder optional
optional optional
√ Temp.
optional
√ chart recorder optional
optional Temp.chart
optional
recorder optional
√ optional
optional √ optional
Back-up battery Back-upoptional
battery optional
optional optional
√ Back-up
optional
√ battery optional
optional Back-up optional
battery optional
√ optional
optional √ optional
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES

Kit of dividers for drawerKit of dividers


√ for drawer √√ √√ Kit√of√dividers for drawer √ √ Kit of dividers
√ for drawer √ √√ √ √
Castors with frontal brakesCastors with√frontal brakes √ √√ Castors
√ √ with frontal brakes √ √ Castors with frontal
√ brakes √ √√ √ √
Temp.chart recorder Temp.chart recorder
√ √√ standard
√ Temp.
standard
√ chart recorder √ √ Temp.chart recorder
√ standard
√ √√ standard √
Back-up battery Back-up battery
√ √ standard
√ Back-up battery
standard
√ √ √ √
Back-up battery standard
√ √√ standard √
GSM module GSM module
√ √ √√ √ √module
GSM √ √ GSM module
√ √√ √√ √ √
LAN Port LAN Port √ √ √√ LAN
√ Port
√ √ √ LAN Port √ √√ √√ √ √
Port hole Port hole √ √ √√ Port
√ hole
√ √ √ Port hole √ √√ √√ √ √
Electric Digital key lock Electric Digital
√ key lock √ √√ Electric
√ √ Digital key lock √ √ Electric Digital√key lock √√ √√ √ √
Power supply 115V/60HzPower supply
√ 115V/60Hz √ √√ Power
√ √ supply 115V/60Hz √ √ Power supply
√ 115V/60Hz √√ √√ √ √
CERTIFICATION CERTIFICATION CE CE
CE MEDICAL
CE DEVICE CERTIFICATION
MEDICAL
CE DEVICE CE CE CERTIFICATION CE MEDICAL
CE DEVICE CE CE MEDICAL DEVICE CE
CLASS IIA CLASS IIA CLASS IIA CLASS IIA
DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG

680x660x2040-145
External Dimensions/weight External Dimensions/weight 780x840x1930-204
680x660x2040-145 780x840x1930-204
780x840x1930-204 780x840x1930-224
780x840x1930-204 780x840x1930-224
External Dimensions/weight 680x660x2040-145External
780x840x1930-204
Dimensions/weight 780x840x1930-204
680x660x2040-145 780x840x1930-224
780x840x1930-204 780x840x1930-204 780x840x1930-224
Packing Dimensions/weight Packing Dimensions/weight Packing Dimensions/weight Packing Dimensions/weight
(carton box) 700x700x2130-160
(carton box) 860x900x2080-216
700x700x2130-160 860x900x2080-216
860x900x2080-216 860x900x2080-240
860x900x2080-216
(carton box) 860x900x2080-240
700x700x2130-160(carton
860x900x2080-216
box) 860x900x2080-216
700x700x2130-160 860x900x2080-240
860x900x2080-216 860x900x2080-216 860x900x2080-240

32 33
COMBINED REFRIGERATOR AND FREEZER
LABORATORY AND PHARMACY
+2°+12°/-10°-30°C from 200/100 to 700/700 lt.

FC/2-AF/2 models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation obtained by injection of high density ecological polyurethane CFC-
free foam for excellent product preservation and energy saving.
door
Self-closing solid or glass door (double insulating – low emissivity glass) for refrigerator
compartment and self-closing solid door for freezer compartment. Folding magnetic
gasket (easy to replace) on four sides for perfect closing. Right hand opening or left
hand on request. Lock with key.
shelves/drawers
Scotch-Brite stainless steel shelves, removable and adjustable in height in refrigerator
compartment. Scotch-Brite stainless steel drawers with telescopic ball-bearing slides
and plexiglas frontal side in freezer compartment (shelves on AF/2 models).
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening
in refrigerator compartment. Manual switch on control panel.
temperature range
Refrigerator compartment: between +2°C and +12°C. Factory preset to +4°C.
Freezer compartment: between -10°C and -30°C. Factory preset to -25°C.
Digital adjustable temperatures with an increment of 0.1°C.
refrigeration system
Two separate completely sealed, silent and highly efficient hermetic compressors
and ventilated air condensers (suitable also for tropical countries). Forced-air cooling
system in refrigerator compartment conceived to achieve maximum temperature
uniformity and stability inside the refrigerator even in case of frequent door openings.
Evaporator fan shuts off during door openings. Static evaporator in freezer compartment.
CFC-free refrigerant R404a or CFC/HCFC-free natural refrigerant R290 on request.
defrosting
Fully automatic defrosting cycle in refrigerator compartment.
Manual defrost in freezer compartment. standard optional accessories
control panel and alarms • Shelves in refrigerator compartment • Scotch-Brite stainless steel sliding drawers (see table)
Microprocessor control panel with colour 4.3” LCD touch screen and keys. • Drawers in freezer compartment (shelves on AF/2 models) • Kit of dividers for drawer
Display with 0.1°C resolution. Temperature monitoring detected by two independent • Castors with frontal brakes • Additional shelf
• Two power cords with Schüko type plug or British type plug • Smooth shelf with borders
PT1000 probes. Real time temperature graph (to be activated by user). • Protection fuses • Weekly temperature chart recorder
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. (on power switch and electronic mainboard) • Back-up battery
Visual and audible alarms of high and low temperature (by means of independent probe), • RFI filter • GSM alarm to send SMS alarm messages to mobile phones
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Password protected power switch and settings • LAN port to connect the appliance via ethernet on PC
power failure with recording of data and alarms (by means of optional back-up battery), • Two microprocessors to monitor temperatures • Digital humidity sensor
• Remote contacts (dry, volt-free) for alarm • Test hole (Ø 25 mm)
damaged or flat battery. Memory of latest alarms visible on display. • Two data loggers with USB port • Electric digital key lock
data logger • Memory of latest alarms visible on screen • Power supply 115V/60Hz
Data logger to record temperatures and alarms in refrigerator and freezer • Power failure at electricity recovery
compartments. Download data on USB pen drive.
Medical Device
Directive 93/42/EEC
34 35
MODEL FC39/2
MODEL FC39V/2
FC39/2 AF70/2
FC39V/2 AF70V/2
AF70/2 AF140/2
AF70V/2 AF140V/2
AF140/2 AF140V/2
TECHNICAL DATA TECHNICAL DATA

Capacity Refrigerator (LT) Capacity


200
Refrigerator (LT) 200 200 350 200 350 350 700 350 700700 700
Capacity Freezer (LT) Capacity
100
Freezer (LT) 100 100 350 100 350 350 700 350 700700 700
Factory set (°C) Factory
+4 set
/ -25
(°C) +4 /+4
-25
/ -25 +4 /+4
-25/ -25 +4 /+4
-25/ -25 +4 /+4
-25/ -25 +4 / +4
-25/ -25 +4 / -25
Temp. range (°C) +2
Temp.
/ +12range
-10 /(°C)
-30 +2 /+2
+12
/ +12
-10 -10
/ -30
/ -30 +2 /+2
+12/ +12
-10 /-10
-30/ -30 +2 /+2
+12
/ +12
-10 -10
/ -30/ -30 +2 /+2
+12/ +12
-10 /-10
-30/ -30+2 /+2
+12/ +12
-10 /-10
-30/ -30 +2 / +12 -10 / -30
Cooling type Refrigerator Forced
Coolingair
type
cooling Forced
Refrigerator Forced
air cooling
air cooling Forced
Forced
air air
cooling
cooling Forced
Forced
air cooling
air coolingForced
Forced
air cooling
air coolingForced
Forced
air cooling
air cooling Forced air cooling
Cooling type Freezer Cooling
Static evaporator
type Freezer Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static
Static
evaporator
evaporator Static evaporator
Refrigerator Automatic Refrigerator
Refrigerator
Automatic
Automatic Refrigerator
Refrigerator
Automatic
Automatic Refrigerator
Refrigerator
Automatic
Automatic Refrigerator
Refrigerator
Automatic
AutomaticRefrigerator
Refrigerator
Automatic
Automatic Refrigerator Automatic
Defrost Defrost
Freezer Manual FreezerFreezer
ManualManual Freezer Manual
Freezer Manual Freezer
Freezer
Manual
Manual Freezer
Freezer
Manual
Manual Freezer
Freezer
Manual
Manual Freezer Manual
CFC-Free Refrigerant gas CFC-
R404a
Free or R290 gas
Refrigerant R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a
R404a
or R290
or R290 R404a or R290
Noise level (db) Noise level
<50 (db) <50 <50 <50 <50 <50 <50 <52<50 <52 <52 <52

specifications
LCD TOUCH 4,3'' LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3''
CONTROL PANEL CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR

VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS

High/Low temperature High/Low


√ temperature √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMSoptional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS

Password protected use Password


√ protected use √ √ √ √ √ √ √ √ √ √ √
Remote alarm Remote√alarm √ √ √ √ √ √ √ √ √ √ √
Data logger Data logger
√ √ √ √ √ √ √ √ √ √ √ √
Humidity probe Humidity
optional
probe optional
optional optional
optional optional
optional optional
optional optional
optional optional
RS232-RS485 serial port RS232-RS485
√ serial port √ √ √ √ √ √ √ √ √ √ √
4-20 mA converter module 4-20 mA√ converter module √ √ √ √ √ √ √ √ √ √ √
Safety thermostat Safety
optional
thermostat optional
optional optional
optional optional
optional optional
optional optional
optional optional
ELECTRICAL DATA ELECTRICAL DATA

Supply voltage (V/Hz) Supply


230/50-230/60
voltage (V/Hz) 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
230/50-230/60 230/50-230/60
Max absorbed current (W) Max absorbed
427 current (W) 427 427 350/480
427 350/480
350/480 1100
350/480 1100
1100 1100
INTERNAL EQUIPMENT INTERNAL EQUIPMENT

Refrigerator compartment 3 shelves


Refrigerator compartment 3 shelves
3 shelves 2 shelves
3 shelves 2 shelves
2 shelves 4 shelves
2 shelves 4 shelves
4 shelves 4 shelves
Freezers compartment 2 drawers
Freezers compartment 2 drawers
2 drawers 3 drawers
2 drawers 3 drawers
3 drawers 4 shelves
3 drawers 4 shelves
4 shelves 4 shelves
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES

Drawer in refrig. compartment Drawer max 3 compartment


in refrig. maxmax
3 3 maxmax
3 3 maxmax
3 3 max 7+max7max 3
in freeze max max
7+max7
7+max7
in freezer
in freeze max 7+max7 in freezer

Kit of dividers for drawer Kit of dividers


√ for drawer √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √
Temp. chart recorder Temp. chart
√ recorder √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up √battery √ √ √ √ √ √ √ √ √ √ √
GSM module GSM module
√ √ √ √ √ √ √ √ √ √ √ √
LAN Port LAN Port√ √ √ √ √ √ √ √ √ √ √ √
Port hole Port hole√ √ √ √ √ √ √ √ √ √ √ √
Electric Digital key lock Electric Digital
√ key lock √ √ √ √ √ √ √ √ √ √ √
Power supply 115V/60Hz Power supply
√ 115V/60Hz √ √ √ √ √ √ √ √ √ √ √
CERTIFICATION CERTIFICATIONCE CE CE CE CE CE CE CE CE CE CE CE

DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG

External Dimensions/weight 600x600x1960-127


External Dimensions/weight600x600x1960-131
600x600x1960-127
700x800x1990-180
600x600x1960-131
700x800x1990-183
700x800x1990-180
1400x800x1990-201
700x800x1990-183
1400x800x1990-223
1400x800x1990-201 1400x800x1990-223
Packing Dimensions/weigh Packing Dimensions/weigh
(carton box) 700x700x2150-137
(carton box) 700x700x2150-141
700x700x2150-137
750x850x2180-193
700x700x2150-141
750x850x2180-198
750x850x2180-193
1500x900x2170-221
750x850x2180-198
1500x900x2170-243
1500x900x2170-221 1500x900x2170-243

36 37
COMBINED REFRIGERATOR
PHARMACY
+2°+15°/+2°+15°C from 150/150 to 700/700 lt.

FP/2 models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation obtained by injection of high density ecological polyurethane CFC-free
foam for excellent product preservation and energy saving.
door
Two self-closing glass doors (double insulating – low emissivity glass) for both refrigerator
compartments. Folding magnetic gasket (easy to replace) on four sides for perfect
closing. Right hand opening or left hand on request. Lock with key.
shelves
Scotch-Brite stainless steel shelves, removable and adjustable in height in both compartments.
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening
in both compartments. Manual switch on control panel.
temperature range
Upper compartment: between +2°C and +15°C. Factory preset to +4°C.
Lower compartment: between +2°C and +15°C. Factory preset to +4°C.
Digital adjustable temperatures with an increment of 0.1°C.
refrigeration system
Two separate completely sealed, silent and highly efficient hermetic compressors and
ventilated air condensers (suitable also for tropical countries). Forced-air cooling system
in both compartments conceived to achieve maximum temperature uniformity and
stability inside the refrigerator even in case of frequent door openings.
Evaporator fan shuts off during door openings. CFC-free refrigerant R404a or CFC/
HCFC-free natural refrigerant R290 on request.
defrosting
standard optional accessories
Fully automatic defrosting cycle in both compartments.
• Shelves • Scotch-Brite stainless steel sliding drawers (see table)
control panel and alarms
• Castors with frontal brakes • Kit of dividers for drawer
Microprocessor control panel with colour 4.3” LCD touch screen and keys. • Two power cords with Schüko type plug or British type plug • Additional shelf
Display with 0.1°C resolution. Temperature monitoring detected by two independent • Protection fuses • Smooth shelf with borders
PT1000 probes. Real time temperature graph (to be activated by user). (on power switch and electronic mainboard) • Weekly temperature chart recorder
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. • RFI filter • Back-up battery
• Password protected power switch and settings • GSM alarm to send SMS alarm messages to mobile phones
Visual and audible alarms of high and low temperature (by means of independent probe),
• Two microprocessors to monitor temperatures • LAN port to connect the appliance via ethernet on PC
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Remote contacts (dry, volt-free) for alarm • Digital humidity sensor
power failure with recording of data and alarms (by means of optional back-up battery), • Two data loggers with USB port • Test hole (Ø 25 mm)
damaged or flat battery. Memory of latest alarms visible on display. • Memory of latest alarms visible on screen • DIN 58345 conformity
data logger • Electric digital key lock
Two data loggers to record temperatures and alarms in both compartments. Medical Device
• Power supply 115V/60Hz
Download data on USB pen drive. Directive 93/42/EEC

38 39
frimed equipment is used in
Afghanistan
Algeria
Australia
Austria
MODEL FP30V/2 FP70V/2 FP60V/2 FP140V/2 Bahrain
Bangladesh
TECHNICAL DATA
Belgium
Capacity (LT) Upper comp. 150 350 300 700 Benin
Capacity (LT) Lower comp. 150 350 300 700 Bosnia-Herzegovina
Cyprus
Factory set +4 / +4 +4 / +4 +4 / +4 +4 / +4
Colombia
Temp. range (°C) +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 Costa Rica
Cooling type Forced air cooling Forced air cooling Forced air cooling Forced air cooling Croatia
Defrost Automatic Automatic Automatic Automatic Czech Republic
CFC-Free Refrigerant gas R404a or R290 R404a or R290 R404a or R290 R404a or R290 Egypt
France
Noise level (db) <50 <50 <52 <52
Georgia
LCD TOUCH 4.3'' LCD TOUCH 4.3'' LCD TOUCH 4.3'' LCD TOUCH 4.3'' Germany
CONTROL PANEL MICROPROCESSOR MICROPROCESSOR MICROPROCESSOR MICROPROCESSOR
Gran Canary
VISUAL AND AUDIBLE ALARMS Great Britain
High/Low temperature √ √ √ √ Greece
Guyana
Open door √ √ √ √
Hong Kong
Condenser efficiency √ √ √ √ India
Damaged sensor √ √ √ √ Indonesia
Power failure optional optional optional optional
Iran
Iraq
Full recording memory √ √ √ √
Israel
SMS alarm message optional optional optional optional Jordan
FUNCTIONS Kenya
Kuwait
Password protected use √ √ √ √
Latvia
Remote alarm √ √ √ √ Lebanon
Data logger √ √ √ √ Malaysia
Humidity probe optional optional optional optiona Malta
Mauritius
RS232-RS485 serial port √ √ √ √
Mexico
4-20 mA converter module √ √ √ √ Moldova
Safety thermostat optional optional optional optional Morocco
Mozambique
ELECTRICAL DATA
Oman
Supply voltage (V/Hz) 230/50-230/60 230/50-230/60 230/50-230/60 230/50-230/60 Pakistan
Max absorbed current (W) 245/245 245/245 245/245 260/260 Peru
Philippines
INTERNAL EQUIPMENT
Poland
Upper compartment 3 shelves 3 shelves 4 shelves 4 shelves Portugal
Lower compartment 3 shelves 3 shelves 4 shelves 4 shelves Qatar
OPTIONAL ACCESSORIES Romania
Saudi Arabia
Drawer max 3/3 max 3/3 max 6/6 max 7/7
Serbia
Kit of dividers for drawer √ √ √ √ Singapore
Additional shelf √ √ √ √ Slovenia
Castors with frontal brakes √ √ √ √ Sri Lanka
Temp.chart recorder √ √ √ √ Sudan
Syria
Back-up battery √ √ √ √
Switzerland
GSM module √ √ √ √ Taiwan
LAN Port √ √ √ √ Thailand
The Netherlands
Port hole √ √ √ √
Tunisia
Electric Digital key lock √ √ √ √ Uganda
Power supply 115V/60Hz √ √ √ √ United Arab Emirates
CERTIFICATION CE CE CE CE
Vietnam
Yemen
DIMENSIONS (WXDXH - MM)/KG
Zambia
External Dimensions/weight 600x600x2040-125 700x800x2040-168 1200x600x1830-198 1400x800x1990-220
Packing Dimensions/weight
(carton box) 700x700x2200-139 750x850x2180-176 1400x700x2200-220 1500x900x2170-240

40