Professional Documents
Culture Documents
Catalogo General FRIMED Refrigeracion 2019
Catalogo General FRIMED Refrigeracion 2019
made in
w
refrigeration field.
as established in 1997,
as result of twenty year experience of its owners in medical
ISO 9001
Certified Quality System
ISO 14001
Certified Environmental System
ISO 13485
Medical Devices
Certified Quality System
International
Organization for Medical Device
Directive 93/42/EEC
Standardization
index
product 6
lab and pharmacy refrigerator 14
blood bank refrigerator 20
laboratory freezer 24
laboratory deep freezer 28
plasma freezer 30
combined refrigerator and freezer 34
combined refrigerator 38
made in
energy saving
and enviroment protection technology
LED lighting
All our cabinets with positive temperature are internally equipped with LED lights.
LED lighting is the solution for reducing energy use, because it allows saving energy up to
70% compared with fluorescent lamps. LED lights have high performance, bright colour and
provide beneficial environmental impact with longer life and therefore less landfill waste.
06 07
technical highlights
structure
External structure in hot-dip galvanised steel, anti-corrosion treated and whte PVC film coated.
Stainless steel internal structure.
insulation
Insulation of 60mm, 80mm, 100mm obtained by injection of high density ecological polyurethane
CFC-free foam for excellent product preservation and best energy saving.
door
Self-closing door with removable magnetic gasket on four sides for perfect closing.
Right hand opening or left hand on request.
led lighting
LED light with automatic switch at door opening. Manual switch on control panel.
shelves
In Scotch-Brite stainless steel. Adjustable in height.
drawers
Sliding drawers in Scotch-Brite stainless steel. Plexiglas frontal side. Optional plexiglas dividers.
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air condenser.
Internal ventilated or static evaporator. CFC-free refrigerant.
defrosting
Fully automatic defrosting cycle with auto-evaporation of condensed water,
or manual defrosting cycle.
test hole
ø 25 mm sidewall test hole for custom probe.
08 09
control panel
Microprocessor control panel with colour 4.3” LCD touch screen and keys
Display showing cabinet temperature, set point, date, hour, equipment model
and electronic accessories
RS232/RS485 ports
visual and acoustic
alarms
Safety thermostat
Two independent PT1000 probes, the first one to set and detect temperature, the other
one to manage the alarm system and display temperature
remote contact
for alarm
Visual and audible alarms through buzzer sound, general alarm warning light and specific
alarm warning icon on display.
Alarms of high and low temperature, open door, condenser efficiency, damaged probes,
power failure at electricity recovery, power failure with recording of data and alarms generated gsm alarm
by back-up battery (standard only on blood bank refrigerator and plasma freezer),
damaged or flat battery
Memory of latest alarms shown on display
Back-up Battery to show temperature on display and to manage the alarm system in case lan port
of power failure
GSM module to send SMS alarms messages to mobile phones showing date, time, cabinet
temperature and type of alarm. Possibility to send SMS messages from mobile phone to
check correct functioning of equipment
LAN port to connect one or more appliances via Ethernet on PC to monitor working state
data logger
USB port to download temperature data and alarms and to upgrade or reset the appliance
Data logger to record temperatures and alarms. Download data on USB pen drive
10 11
SHU air purifier
A revolution in air sanitization and purification of your refrigerator.
The technology used by SHU quickly and effectively attacks and destroys micro-organisms which
are harmful to humans (mould, bacteria, viruses, odours and volatile organic compounds) by taking
advantage of extraordinary biochemical processes.
Shu air purifier is the only one currently on the market using “state-of-the-art” technology.This is the
latest and most advanced technology which is used in NASA aerospace stations.
This system, active 24 hours a day, is capable already in the first 90 minutes of use, of eliminating more
than 95% of viruses, bacteria and mould in the environment.
The germicidal UV lamp destroys germs that pass through the UVC light rays.
The rays of light from the UV lamp react with the nano Nickel HCT ™ catalyst producing catalytic
molecules. The catalytic molecules detect and destroy the carbon-based molecules by converting
them into harmless carbon dioxide and water.
Unlike other purification systems on the market, SHU is not limited to purifying the air that passes
through the catalyst, but also emits a thick layer of molecules into the air (ROS Reactive Oxygen Species)
that purifies the air throughout the whole environment.
shu, via ahpco technology,produces a layer of hydroxide ions, radicals, radical peroxides, hydro peroxides
which through the action of light and air humidity, triggers a reaction of decomposition of organic and
inorganic substances: only the oxygen and hydrogen molecules remain in the air. It is an absolutely
natural phenomenon similar to what occurs during a storm: the air is purified.
Salmonella enterica
Staphylococcus aureus
Resistant strains of Staphylococcus aureus:
Methicillin resistant (MRSA) and CA-MRSA /
PVL-MRSA
Vancomycin resistant Enterococcus (VRE)
Listeria monocytogenes
Escherichia coli (E. coli O157: H7)
Campylobacter jejuni
Acinetobacter baumannii
HIV 1
Influenza A
Avian Influenza
H1N1 (Human and Swine)
Herpes Simplex Type 1
Polio Type 2
Norovirus and Murine Norovirus
Rhinovirus
12 13
REFRIGERATOR
LABORATORY AND PHARMACY
+2°+12°C from 100 to 1400 lt.
SB-FS-PN-AF models
structure
External structure in hot-dip galvanised steel, anti-corrosion treated and PVC
film coated. Stainless steel internal structure.
insulation
60 mm of insulation obtained by injection of high density ecological polyurethane CFC-free
foam for excellent product preservation and energy saving.
door
Self-closing solid or glass door (double insulating - low emissivity glass) with folding
magnetic gasket (easy to replace) on four sides for perfect closing.
Right hand opening or left hand on request. Lock with key.
shelves
Scotch-Brite stainless steel shelves, removable and adjustable in height.
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening.
Manual switch on control panel.
temperature range
Between +2°C and +12°C. Factory preset to +4°C.
Digital adjustable with an increment of 0.1°C
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser (suitable also for tropical countries). Forced-air cooling system conceived
to achieve maximum temperature uniformity and stability inside the refrigerator even
in case of frequent door openings. Evaporator fan shuts off during door opening.
CFC-free refrigerant R404a or CFC/HCFC-free natural refrigerant R290 on request.
defrosting standard optional accessories
Fully automatic defrosting cycle and auto-evaporation of condensed water. • Shelves • Scotch-Brite stainless steel sliding drawers with
• Four one-way wheels with stabilizing adjustable feet telescopic ball-bearing slides. Plexiglas frontal side
control panel and alarms
Microprocessor control panel with colour 4.3” LCD touch screen and keys. • Power cord with Schüko type plug or British type plug • Kit of dividers for drawer
• Protection fuses (on power switch and electronic mainboard) • Additional shelf
Display with 0.1°C resolution. Temperature monitoring detected by two independent • RFI filter • Smooth shelf with borders
PT1000 probes. Real time temperature graph (to be activated by user). • Password protected power switch and settings • Castors with frontal brakes
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. • Electronic control panel with alarm system • Weekly temperature chart recorder
Visual and audible alarms of high and low temperature (by means of independent probe), • Remote contact (dry, volt-free) for alarm • Back-up battery
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Data Logger with USB port • GSM alarm to send SMS alarm messages
• Memory of latest alarms visible on screen to mobile phones
power failure with recording of data and alarms (by means of optional back-up battery), • Power failure at electricity recovery • LAN port to connect the appliance via ethernet on PC
damaged or flat battery. Memory of latest alarms visible on display. • Safety thermostat
data logger • Digital humidity sensor
To record temperatures and alarms. Download data on USB pen drive. Medical Device • Test hole (Ø 25 mm)
Directive 93/42/EEC
• DIN 58345 conformity
• Electric digital key lock
• Power supply 115V/60Hz
14 15
MODEL SB10
MODEL SB10V
SB10 FS15
SB10V FS15V
FS15 FS20
FS15V FS20V
FS20 FS25
FS20V FS25V
FS25 FS30
FS25V FS30V
FS30 FS30V
TECHNICAL DATA TECHNICAL DATA
specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS
Shelves Shelves2 2 2 2 2 2 2 3 2 3 3 4 3 4 4 5 4 5 5 5
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
Drawer Drawer
max 2 max
max
2 2 maxmax
3 2 max
max
3 3 max
max
4 3 maxmax
4 4 max max
5 4 maxmax
5 5 max
max6 5 max
max
6 6 max 6
Kit of dividers for drawer Kit of dividers
√ for drawer √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Additional shelf Additional
√ shelf √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Shelf with border Shelf with
√ border √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Temp.chart recorder Temp.chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up √battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
16 17
MODEL PN45
MODEL PN45V
PN45 PN52
PN45V PN52V
PN52 AF70
PN52V AF70V
AF70 AF140
AF70V AF140V
AF140 AF140V
TECHNICAL DATA TECHNICAL DATA
specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS
Shelves Shelves3 3 3 4 3 4 4 4 4 4 4 8 4 8 8 8
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
Drawer Drawer
max 5 max
max
5 5 maxmax
6 5 max
max
6 6 max
max
7 6 maxmax
7 7 maxmax
14 7 maxmax
14 14 max 14
Kit of dividers for drawer Kit of dividers
√ for drawer √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Additional shelf Additional
√ shelf √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Shelf with border Shelf with
√ border √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Castors with frontal brakes Castors with
√ frontal brakes √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Temp.chart recorder Temp.chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up √battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
18 19
BLOOD BANK REFRIGERATOR
FROM 64 TO 770 BLOOD BAGS (450 ml/each)
+2°+6°C from 100 to 1400 lt.
SB-FS-PN-AF models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation obtained by injection of high density ecological polyurethane CFC-free
foam for excellent product preservation and energy saving.
door
Self-closing glass door (double insulating – low emissivity glass) with folding magnetic gasket
(easy to replace) on four sides for perfect closing. Right hand opening or left hand on request.
Lock with key.
drawers
Scotch-Brite stainless steel drawers with telescopic ball-bearing slides and plexiglas
frontal side. Optional plexiglas internal dividers.
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening.
Manual switch on control panel.
temperature range
Between +2°C and +6°C. Factory preset to +4°C. Digital adjustable with an increment of 0.1°C
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air condenser
(suitable also for tropical countries). Forced-air cooling system conceived to achieve maximum
temperature uniformity and stability inside the refrigerator even in case of frequent door
openings. Evaporator fan shuts off during door opening. CFC-free refrigerant R404a
or CFC/HCFC-free natural refrigerant R290 on request.
defrosting certification
Fully automatic defrosting cycle and auto-evaporation of condensed water. Certified in accordance with Medical Device Directive 93/42/EEC
control panel and alarms class IIa for storage and preservation of blood.
Microprocessor control panel with colour 4.3” LCD touch screen and keys.
Display with 0.1°C resolution. Temperature monitoring detected by two independent PT1000 0476
probes. Real time temperature graph (to be activated by user). Optional humidity sensor.
RS232/RS 485 port. Digital calibration of probe.
standard optional accessories
Visual and audible alarms of high and low temperature (by means of independent probe),
open door, condenser efficiency, damaged probes, power failure with recording of data and • Drawers • Kit of dividers for drawer
• Four one-way wheels with stabilizing adjustable feet • Castors with frontal brakes
alarms (by means of back-up battery), damaged or flat battery. Memory of latest alarms • Power cord with Schüko type plug or British type plug • GSM alarm to send SMS alarm messages
visible on display • Protection fuses (on power switch and electronic mainboard) to mobile phones
data logger • RFI filter • LAN port
To record temperatures and alarms. Download data on USB pen drive. • Password protected power switch and settings to connect the appliance via ethernet on PC
back-up battery
• Electronic control panel with alarm system • Digital humidity sensor
• Safety thermostat • Test hole (Ø 25 mm)
Self-powered back-up battery supplying electric power to control panel in order to • Weekly temperature chart recorder • Electric digital key lock
generate alarms in case of power failure. • Back-up battery • Power supply 115V/60Hz
temperature chart recorder • Remote contact (dry, volt-free) for alarm
Weekly temperature recording system working with 1,5V battery. It is equipped with 52 • Data Logger with USB port
paper disks and an ink pen. • Memory of latest alarms visible on screen
• DIN 58371 conformity
20 21
MODEL SB10E
MODEL FS15E
SB10E FS20E
FS15E FS25E
FS20E FS30E
FS25E PN45E
FS30E PN52E
PN45E AF70E
PN52E AF140E
AF70E AF140E
TECHNICAL DATA TECHNICAL DATA
specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Power failure Power failure
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS
Drawers Drawers2 3 2 4 3 5 4 6 5 5 6 6 5 7 6 14 7 14
Temp. chart recorder Temp. chart
√ recorder √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Back-up battery Back-up√battery √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
CERTIFICATION CERTIFICATION
MEDICAL DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL
MEDICAL
DEVICE
DEVICE MEDICAL DEVICE
93/42 CLASS IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASS
CLASS
IIA IIA 93/42
93/42
CLASSCLASS
IIA IIA 93/42 CLASS IIA
DIMENSIONS (WXDXH - MM)/KG DIMENSIONS (WXDXH - MM)/KG
22 23
FREEZER
LABORATORY
-25°-30° from 100 to 1400 lt.
24 25
MODEL SB10B
MODEL SB10B
SB10B
special CV3
SB10Bspecial CV4
CV3 CV5
CV4 CV6
CV5 AF70B
CV6 AF70B
AF70B
special AF140B
AF70Bspecial AF140B
AF140B
special AF140Bspecial
TECHNICAL DATA TECHNICAL DATA
specifications
High/Low temperature High/Low
√ temperature √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Open door Open door
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Condenser efficiency Condenser
√ efficiency √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Damaged sensor Damaged
√ sensor √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ v √ v
Power failure Power
optional
failure optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
Full recording memory Full recording
√ memory √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
SMS alarm message SMS optional
alarm message optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
optional optional
FUNCTIONS FUNCTIONS
26 27
DEEP FREEZER
LABORATORY
-40° from 300 to 600 lt.
CL models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
100mm insulation obtained by injection of high density ecological polyurethane CFC-
free foam for excellent product preservation and energy saving.
door
Self-closing solid door with two folding magnetic gaskets (easy to replace) on four sides for
perfect closing. Right hand opening or left hand on request. Optional electric digital key lock.
shelves/drawers
Standard equipped with either Scotch-Brite stainless steel shelves, removable and
adjustable in height or Scotch-Brite stainless steel drawers with telescopic ball-bearing
slides and plexiglas frontal side.
temperature range
Between -10°C and -42°C. Factory preset to -40°C. Digital adjustable temperature
with an increment of 0.1°C.
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser. Static evaporator. CFC-free refrigerant R404a or CFC/HCFC-free natural
refrigerant R290 on request.
defrosting
Manual defrosting cycle.
control panel and alarms
Microprocessor control panel with colour 4.3” LCD touch screen and keys. Display with
0.1°C resolution. Temperature monitoring detected by two independent PT1000 probes.
Real time temperature graph (to be activated by user).
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. standard optional accessories
Visual and audible alarms of high and low temperature (by means of independent probe), • Shelves or drawers • Kit of dividers for drawer
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Four one-way wheels with stabilizing adjustable feet • Additional shelf
power failure with recording of data and alarms (by means of optional back-up battery), • Power cord with Schüko type plug or British type plug • Smooth shelf with borders
damaged or flat battery. Memory of latest alarms visible on display • Protection fuses • Castors with frontal brakes
(on power switch and electronic mainboard) • Weekly temperature chart recorder
data logger
• RFI filter • Back-up battery
To record temperatures and alarms. Download data on USB pen drive. • Password protected power switch and settings • GSM alarm to send SMS alarm messages to mobile phones
• Electronic control panel with alarm system • LAN port to connect the appliance via ethernet on PC
• Remote contact (dry, volt-free) for alarm • Safety thermostat
• Data Logger with USB port • Digital humidity sensor
• Memory of latest alarms visible on screen • Test hole (Ø 25 mm)
• Power failure at electricity recovery • Electric digital key lock
• Power supply 115V/60Hz
Medical Device
Directive 93/42/EEC
28 29
PLASMA FREEZER
-40° 600 lt.
CL60B/PF model
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
100mm insulation obtained by injection of high density ecological polyurethane CFC-
free foam for excellent product preservation and energy saving.
door
Self-closing solid door with two folding magnetic gaskets (easy to replace) on four sides for
perfect closing. Right hand opening or left hand on request. Optional electric digital
key lock.
drawers
Standard equipped with 6 Scotch-Brite stainless steel drawers with telescopic ball-
bearing slides and plexiglas frontal side. Optional kit of Plexiglas dividers for drawer.
temperature range
Between -30°C and -42°C. Factory preset to -40°C. Digital adjustable temperature
with an increment of 0.1°C.
refrigeration system
Completely sealed, silent and highly efficient hermetic compressor and ventilated air
condenser. Static evaporator. CFC-free refrigerant R404a or CFC/HCFC-free natural
refrigerant R290 on request.
defrosting
Manual defrosting cycle. certification
control panel and alarms Certified in accordance with Medical Device Directive 93/42/EEC
Microprocessor control panel with colour 4.3” LCD touch screen and keys. class IIa for storage and preservation of plasma.
Display with 0.1°C resolution. Temperature monitoring detected by two independent
PT1000 probes. Real time temperature graph (to be activated by user). 0476
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe.
Visual and audible alarms of high and low temperature (by means of independent probe),
open door, condenser efficiency, damaged probes, power failure with recording of data
standard optional accessories
and alarms (by means of back-up battery), damaged or flat battery. Memory of latest • Drawers • Kit of dividers for drawer
• Four one-way wheels with stabilizing adjustable feet • Castors with frontal brakes
alarms visible on display. • Power cord with Schüko type plug or British type plug • GSM alarm to send SMS alarm messages to mobile phones
data logger • Protection fuses • LAN port to connect the appliance via ethernet on PC
To record temperatures and alarms of last 30 days. Download data on USB pen drive. (on power switch and electronic mainboard) • Digital humidity sensor
back-up battery • RFI filter • Test hole (Ø 25 mm)
Self-powered back-up battery supplying electric power to control panel in order to • Password protected power switch and settings • Electric digital key lock
• Electronic control panel with alarm system • Power supply 115V/60Hz
generate alarms in case of power failure. • Remote contact (dry, volt-free) for alarm
temperature chart recorder • Weekly temperature chart recorder
Weekly temperature recording system working with 1,5V battery. It is equipped with 52 • Back-up battery
paper disks and an ink pen. • Remote contact (dry, volt-free) for alarm
• Data Logger with USB port
• Memory of latest alarms visible on screen
• DIN 58375 conformity
30 31
MODEL CL30B
MODEL CL60B
CL30B CL60B/PF
CL60B CL60B/PF
CL60B/2
MODEL CL60B/2
CL30B CL60B
MODEL CL60B/PF
CL30B CL60B/2
CL60B CL60B/PF CL60B/2
TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA TECHNICAL DATA
VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS VISUAL AND AUDIBLE ALARMS
specifications
High/Low temperature High/Low temperature
√ √ √√ High/Low
√ temperature √ √ High/Low temperature
√ √√ √ √ √
Open door Open door√ √ √√ Open√ door √ √ Open door √ √√ √ √ √
Condenser efficiency Condenser efficiency
√ √ √√ Condenser
√ efficiency √ √ √
Condenser efficiency √√ √ √ √
Damaged sensor Damaged sensor
√ √ √√ Damaged
√ sensor √ √ √
Damaged sensor √√ √ √ √
Power failure Power failure
optional optional
optional optional
√ Power√ failure
optional optional
optional optional
Power failure optional
√ optional
optional √ optional
Full recording memory Full recording √
memory √ √√ Full recording
√ memory √ √ Full recording memory
√ √√ √ √ √
SMS alarm message SMS alarm
optional
message optional
optional optional SMS
optional
optional
alarm message optional
optional SMS alarm
optional
message optional
optional optional
optional optional optional
FUNCTIONS FUNCTIONS FUNCTIONS FUNCTIONS
680x660x2040-145
External Dimensions/weight External Dimensions/weight 780x840x1930-204
680x660x2040-145 780x840x1930-204
780x840x1930-204 780x840x1930-224
780x840x1930-204 780x840x1930-224
External Dimensions/weight 680x660x2040-145External
780x840x1930-204
Dimensions/weight 780x840x1930-204
680x660x2040-145 780x840x1930-224
780x840x1930-204 780x840x1930-204 780x840x1930-224
Packing Dimensions/weight Packing Dimensions/weight Packing Dimensions/weight Packing Dimensions/weight
(carton box) 700x700x2130-160
(carton box) 860x900x2080-216
700x700x2130-160 860x900x2080-216
860x900x2080-216 860x900x2080-240
860x900x2080-216
(carton box) 860x900x2080-240
700x700x2130-160(carton
860x900x2080-216
box) 860x900x2080-216
700x700x2130-160 860x900x2080-240
860x900x2080-216 860x900x2080-216 860x900x2080-240
32 33
COMBINED REFRIGERATOR AND FREEZER
LABORATORY AND PHARMACY
+2°+12°/-10°-30°C from 200/100 to 700/700 lt.
FC/2-AF/2 models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation obtained by injection of high density ecological polyurethane CFC-
free foam for excellent product preservation and energy saving.
door
Self-closing solid or glass door (double insulating – low emissivity glass) for refrigerator
compartment and self-closing solid door for freezer compartment. Folding magnetic
gasket (easy to replace) on four sides for perfect closing. Right hand opening or left
hand on request. Lock with key.
shelves/drawers
Scotch-Brite stainless steel shelves, removable and adjustable in height in refrigerator
compartment. Scotch-Brite stainless steel drawers with telescopic ball-bearing slides
and plexiglas frontal side in freezer compartment (shelves on AF/2 models).
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening
in refrigerator compartment. Manual switch on control panel.
temperature range
Refrigerator compartment: between +2°C and +12°C. Factory preset to +4°C.
Freezer compartment: between -10°C and -30°C. Factory preset to -25°C.
Digital adjustable temperatures with an increment of 0.1°C.
refrigeration system
Two separate completely sealed, silent and highly efficient hermetic compressors
and ventilated air condensers (suitable also for tropical countries). Forced-air cooling
system in refrigerator compartment conceived to achieve maximum temperature
uniformity and stability inside the refrigerator even in case of frequent door openings.
Evaporator fan shuts off during door openings. Static evaporator in freezer compartment.
CFC-free refrigerant R404a or CFC/HCFC-free natural refrigerant R290 on request.
defrosting
Fully automatic defrosting cycle in refrigerator compartment.
Manual defrost in freezer compartment. standard optional accessories
control panel and alarms • Shelves in refrigerator compartment • Scotch-Brite stainless steel sliding drawers (see table)
Microprocessor control panel with colour 4.3” LCD touch screen and keys. • Drawers in freezer compartment (shelves on AF/2 models) • Kit of dividers for drawer
Display with 0.1°C resolution. Temperature monitoring detected by two independent • Castors with frontal brakes • Additional shelf
• Two power cords with Schüko type plug or British type plug • Smooth shelf with borders
PT1000 probes. Real time temperature graph (to be activated by user). • Protection fuses • Weekly temperature chart recorder
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. (on power switch and electronic mainboard) • Back-up battery
Visual and audible alarms of high and low temperature (by means of independent probe), • RFI filter • GSM alarm to send SMS alarm messages to mobile phones
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Password protected power switch and settings • LAN port to connect the appliance via ethernet on PC
power failure with recording of data and alarms (by means of optional back-up battery), • Two microprocessors to monitor temperatures • Digital humidity sensor
• Remote contacts (dry, volt-free) for alarm • Test hole (Ø 25 mm)
damaged or flat battery. Memory of latest alarms visible on display. • Two data loggers with USB port • Electric digital key lock
data logger • Memory of latest alarms visible on screen • Power supply 115V/60Hz
Data logger to record temperatures and alarms in refrigerator and freezer • Power failure at electricity recovery
compartments. Download data on USB pen drive.
Medical Device
Directive 93/42/EEC
34 35
MODEL FC39/2
MODEL FC39V/2
FC39/2 AF70/2
FC39V/2 AF70V/2
AF70/2 AF140/2
AF70V/2 AF140V/2
AF140/2 AF140V/2
TECHNICAL DATA TECHNICAL DATA
specifications
LCD TOUCH 4,3'' LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3'' 4,3''
LCD TOUCH LCD TOUCH 4,3''
CONTROL PANEL CONTROL PANEL
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
MICROPROCESSOR MICROPROCESSOR
36 37
COMBINED REFRIGERATOR
PHARMACY
+2°+15°/+2°+15°C from 150/150 to 700/700 lt.
FP/2 models
structure
External structure in hot-dip galvanized steel, anti-corrosion treated and PVC film coated.
Scotch-Brite stainless steel internal structure.
insulation
60mm insulation obtained by injection of high density ecological polyurethane CFC-free
foam for excellent product preservation and energy saving.
door
Two self-closing glass doors (double insulating – low emissivity glass) for both refrigerator
compartments. Folding magnetic gasket (easy to replace) on four sides for perfect
closing. Right hand opening or left hand on request. Lock with key.
shelves
Scotch-Brite stainless steel shelves, removable and adjustable in height in both compartments.
light
LED light (energy saving up to 70%, ecological) with automatic switch at door opening
in both compartments. Manual switch on control panel.
temperature range
Upper compartment: between +2°C and +15°C. Factory preset to +4°C.
Lower compartment: between +2°C and +15°C. Factory preset to +4°C.
Digital adjustable temperatures with an increment of 0.1°C.
refrigeration system
Two separate completely sealed, silent and highly efficient hermetic compressors and
ventilated air condensers (suitable also for tropical countries). Forced-air cooling system
in both compartments conceived to achieve maximum temperature uniformity and
stability inside the refrigerator even in case of frequent door openings.
Evaporator fan shuts off during door openings. CFC-free refrigerant R404a or CFC/
HCFC-free natural refrigerant R290 on request.
defrosting
standard optional accessories
Fully automatic defrosting cycle in both compartments.
• Shelves • Scotch-Brite stainless steel sliding drawers (see table)
control panel and alarms
• Castors with frontal brakes • Kit of dividers for drawer
Microprocessor control panel with colour 4.3” LCD touch screen and keys. • Two power cords with Schüko type plug or British type plug • Additional shelf
Display with 0.1°C resolution. Temperature monitoring detected by two independent • Protection fuses • Smooth shelf with borders
PT1000 probes. Real time temperature graph (to be activated by user). (on power switch and electronic mainboard) • Weekly temperature chart recorder
Optional humidity sensor. RS232/RS 485 port. Digital calibration of probe. • RFI filter • Back-up battery
• Password protected power switch and settings • GSM alarm to send SMS alarm messages to mobile phones
Visual and audible alarms of high and low temperature (by means of independent probe),
• Two microprocessors to monitor temperatures • LAN port to connect the appliance via ethernet on PC
open door, condenser efficiency, damaged probes, power failure at electricity recovery, • Remote contacts (dry, volt-free) for alarm • Digital humidity sensor
power failure with recording of data and alarms (by means of optional back-up battery), • Two data loggers with USB port • Test hole (Ø 25 mm)
damaged or flat battery. Memory of latest alarms visible on display. • Memory of latest alarms visible on screen • DIN 58345 conformity
data logger • Electric digital key lock
Two data loggers to record temperatures and alarms in both compartments. Medical Device
• Power supply 115V/60Hz
Download data on USB pen drive. Directive 93/42/EEC
38 39
frimed equipment is used in
Afghanistan
Algeria
Australia
Austria
MODEL FP30V/2 FP70V/2 FP60V/2 FP140V/2 Bahrain
Bangladesh
TECHNICAL DATA
Belgium
Capacity (LT) Upper comp. 150 350 300 700 Benin
Capacity (LT) Lower comp. 150 350 300 700 Bosnia-Herzegovina
Cyprus
Factory set +4 / +4 +4 / +4 +4 / +4 +4 / +4
Colombia
Temp. range (°C) +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 +2 / +15 Costa Rica
Cooling type Forced air cooling Forced air cooling Forced air cooling Forced air cooling Croatia
Defrost Automatic Automatic Automatic Automatic Czech Republic
CFC-Free Refrigerant gas R404a or R290 R404a or R290 R404a or R290 R404a or R290 Egypt
France
Noise level (db) <50 <50 <52 <52
Georgia
LCD TOUCH 4.3'' LCD TOUCH 4.3'' LCD TOUCH 4.3'' LCD TOUCH 4.3'' Germany
CONTROL PANEL MICROPROCESSOR MICROPROCESSOR MICROPROCESSOR MICROPROCESSOR
Gran Canary
VISUAL AND AUDIBLE ALARMS Great Britain
High/Low temperature √ √ √ √ Greece
Guyana
Open door √ √ √ √
Hong Kong
Condenser efficiency √ √ √ √ India
Damaged sensor √ √ √ √ Indonesia
Power failure optional optional optional optional
Iran
Iraq
Full recording memory √ √ √ √
Israel
SMS alarm message optional optional optional optional Jordan
FUNCTIONS Kenya
Kuwait
Password protected use √ √ √ √
Latvia
Remote alarm √ √ √ √ Lebanon
Data logger √ √ √ √ Malaysia
Humidity probe optional optional optional optiona Malta
Mauritius
RS232-RS485 serial port √ √ √ √
Mexico
4-20 mA converter module √ √ √ √ Moldova
Safety thermostat optional optional optional optional Morocco
Mozambique
ELECTRICAL DATA
Oman
Supply voltage (V/Hz) 230/50-230/60 230/50-230/60 230/50-230/60 230/50-230/60 Pakistan
Max absorbed current (W) 245/245 245/245 245/245 260/260 Peru
Philippines
INTERNAL EQUIPMENT
Poland
Upper compartment 3 shelves 3 shelves 4 shelves 4 shelves Portugal
Lower compartment 3 shelves 3 shelves 4 shelves 4 shelves Qatar
OPTIONAL ACCESSORIES Romania
Saudi Arabia
Drawer max 3/3 max 3/3 max 6/6 max 7/7
Serbia
Kit of dividers for drawer √ √ √ √ Singapore
Additional shelf √ √ √ √ Slovenia
Castors with frontal brakes √ √ √ √ Sri Lanka
Temp.chart recorder √ √ √ √ Sudan
Syria
Back-up battery √ √ √ √
Switzerland
GSM module √ √ √ √ Taiwan
LAN Port √ √ √ √ Thailand
The Netherlands
Port hole √ √ √ √
Tunisia
Electric Digital key lock √ √ √ √ Uganda
Power supply 115V/60Hz √ √ √ √ United Arab Emirates
CERTIFICATION CE CE CE CE
Vietnam
Yemen
DIMENSIONS (WXDXH - MM)/KG
Zambia
External Dimensions/weight 600x600x2040-125 700x800x2040-168 1200x600x1830-198 1400x800x1990-220
Packing Dimensions/weight
(carton box) 700x700x2200-139 750x850x2180-176 1400x700x2200-220 1500x900x2170-240
40