SP02

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

SABS Project Name

Job Ref.
Steel Advanced Buildings' Systems JQ-426
Bldg. 08, St. No. 264, New Maadi Calc. By Date Checked By Date Rev. 0
Phone : (+202) 2516 49 06 - (+202) 2517 58 56 MFA 8/12/2015 Sheet No. 0
CONNECTION ID :- SP01 referance
ECP
1)- APPLIED FORCES : case a/b St. 52 Fy = 3.45 t/cm2
M = 8.00 mt a
Q = 1.60 t B
Text = 0.00 t w
e
h
2)- BOLTS USED ARE : p
M 22 Q 8.8
A = 3.80 cm2
AS = 2.66 cm2
H
qall = 2.00 t/cm2 Y1
Y2
fall = 2.64 t/cm 2
N.A
3)- DIMS. OF HEAD PLATE USED ARE : X
H = 72.2 cm
Y4 Y3
B = 20.0 cm

4)- NO. OF BOLTS REQUIRED :


n = 8 bolts e = 4.00 cm
No of bolts ber row 2 p = 9.00 cm

5)- ARRANGEMENT OF BOLTS :


y1 = 68.20 cm y8 = 0.00 cm
y2 = 59.20 cm y9 = 0.00 cm
y3 = 13.00 cm y10 = 0.00 cm
y4 = 4.00 cm y11 = 0.00 cm
y5 = 0.00 cm y12 = 0.00 cm
y6 = 0.00 cm y13 = 0.00 cm
y7 = 0.00 cm y14 = 0.00 cm
after the previous input click on Data--->Solver----->Solve :to get the value of X
6)- CHECK FORCES ON BOLTS :
X = 7.881 cm
In.v. = 36769.828 cm4
Rt.a. = 3.491 t
Rsh.a = 0.200 t
Rt = 7.022 t
Rs.s = 7.600 t
2 2
Rsh.a Rt.a.
Rs.s
+
Rt
= 0.248 <1 SAFE

7)- CHECK HEAD PLATE THICKNESS :


h = 83 mm
w = 45 mm
Mplate = Text,b,m x w = 15.709 cmt

tp = √(6Mplate/(FbXh)) = 2.138 cm 22.00 mm

8)- CHECK COMPRESSION ON HEAD PLATE :

fc = (M x X)/In.v = 0.171 t/cm2 < 2.01 t/cm2 SAFE

9)- CHECK CONNECTION LOCAL STRESSES :


Column Dimensions Beam Dimensions Column Section is : B.U.S
hwc = 450.0 mm h wb
= 550.0 mm * doubler plate is not recommended to use
twc = 5.0 mm twb = 5.0 mm
bfc = 175.0 mm bfb = 175.0 mm
tfc = 6.0 mm tfb = 6.0 mm

a) Check on bending on column flange in tension:


tfc < 0.4 bfb tfb = 12.9614813968157 mm
use Doubler Plate , Flange Stiffeners or increase column flange thick.
doubler plate thick. = 8 mm
flange stiffeners thick. = 8 mm ,width of stiffener = 70 mm
req. col. Flange thick. = 13 mm

b) Check on crippling of column flange in compression:


twc < tfb*bfb / tfb*2tp*5K = 10 mm
use Doubler Plate or Flange Stiffeners
doubler plate thick. = 6 mm
flange stiffeners thick. = 8 mm

c) Check on distortion of column flange in compression:


twc > (M/db) / 0.35*fy*hwc = 3 mm
O.K. distortion of column web is prevented
doubler plate thick. = 6 mm
diagonal stiffeners thick. = 6 mm ,width of stiffener = 50 mm

You might also like