DESIGN CALCULATION OF 8.

00 m OCT POLE FOUNDATION


Anmol
1 SOIL BEARING CAPACITY 10 T/m2
2 HEIGHT OF POLE H 8.00 m
3 BASIC WIND SPEED 50 m/s
4 GRADE OF CONCRETE M 25
5 TOTAL WT OF POLE 68.55632844 Kg
6 TOTAL WT OF LUM WITH ARM 32 Kg
7 TOTAL DEAD WT BASE 100.5563284 Kg
986.457582 N
8 DESIGN WIND SPEED Vz 45 m/s
9 DESIGN WIND PRESSURE F 1215 N/Sq.m
10 TOTAL HORRIZONTAL FORCE 1779.654805 N
11 TOTAL MOMENT AT THE BASE "M"= 8634.059409 Nm
12 DEPTH OF FOUNDATION FROM BASE OF POLE D 1.7 m
13 CLEAR COVER OPENING d' 50 mm

THUS VARIOUS FORCE ACTING ON THE FOUNDATION

1 DEAD LOAD OF THE POLE & BRACKET (DOWNWORD/VERTICAL) Fv 986.457582 N


0.100556328 T

2 TOTAL HORIZONTAL SHERE FORCE SF 1779.654805 N


0.181412314 T

3 MOMENT AT THE BASE OF THE FOUNDATION M 8634.059409 Nm


0.88012838 Tm

ASSUME FOUNDATION OF FOLLOWING SIZE

200

1500

600

1 WIDTH OF FOUNDATION COLUMN (L1*l1) L1 0.6 m


2 DEPTH OF FOUNDATION COLUMN FROM BASE H1 1.7 m
3 HEIGHT OF COLUMN ABOVE GROUND h1 0.2 m
6 TOTAL DEPTH OF FOUNDATION GROM GL PD 1.5 m
DESIGN OF COLUMN AS PER EN 40-2 (APPENDIX A)

DEPTH OF FULCRUM FROM GL ABOUT WHICH OVER TURNING MOMENT


TO BE CALCULATED 1/√2*PD 1.060820368 m

DEPTH OF FULCRUM FROM BASE PLATE ABOUT WHICH OVER TURNING


MOMENT TO BE CALCULATED h 1.260820368 m

OVERTURNING MOMENT AT THIS FULCRUM M+SF*h 1.108856721 Tm

FACTOR OF SAFETY 1.25

OVERTURNING MOMENT CONSIDERING FACTOR OF SAFETY 1.386070901 Tm

GROUND RESISTING MOMENT IN kNm Mg= (GDP^3)/10

WHERE G= FACTOR (AS PER TABLE 1 OF APPENDIX A) (FOR AVERAGE SOIL) 390 kN/m2

D= DIA OR ACROSS FLAT OF COLUMN 0.6 m

P= PLANTING DEPTH 1.5 m

GROUND RESISTING MOMENT Mg= 78.975 kNm


8.050458716 Tm
> 1.386070901 Tm
SO, IT IS SAFE

CHECK FOR BEARING PRESSURE DUE TO VERTICAL LOAD

VOLUME OF CONCRETE COLUMN 0.612 m3

SPECIFIC GRAVITY OF CONCRETE 2.5

SELF WEIGHT OF COLUMN 1.53 T

DEAD LOAD OF THE POLE & BRACKET (DOWNWORD/VERTICAL) 0.100556328 T

TOTAL VERTICAL LOAD 1.630556328 T

BEARING PRESSURE 4.529323135 T/m2


< SBC 10 T/m2
SO, IT IS SAFE
DESIGN OF COLUMN REINFORCEMENT

SIZE OF SQUARE PEDESTAL (B=D=) 600 mm


LOAD ON PEDESTAL 1.631 T
MOMENT 1.386070901 Tm
1.386070901 Tm
Pu/(fckBD) 0.001811729
Mu/(fckBD^2) 2.5668E-07
Mu/BD2 6.41699E-06
d'/D 0.083333333
Pt (provide minimum 0.15% steel) 0.15 %

CONSIDER DIAMETER OF BAR FOR LONGITUDINAL REINFORCEMENT 12 mm


CONSIDER DIAMETER OF BAR FOR RING 6 mm
CONSIDER NO OF BAR FOR LONGITUDINAL REINFORCEMENT 8
.@ CC OF 250
CONSIDER NO OF BAR FOR RING 8
.@ CC OF 242.8571429

Pt (act) 0.2512 %
> 0.15 SAFE