Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

 

 
Data Sheet

Applicator Sizing - Condensed (Flow)


 
Project
Project DED PK SOYBEAN EXTRACTION PLANT
C.Project No.
Customer: PT REKAYASA ENGINEERING
TAG FT-04
Timestamp ---
Review number ---
Sales order number
Contact person Elvis Soegianto
eMail: elvis.soegianto@endress.com
Phone 08119528018
Fax
 
General Parameters Operating Conditions
Fluid Steam, superheated minimum nominal maximum
State Steam Superheated Requested Flow 26 250 26 250 26 250 m3/h
Character Clean Pressure 14.5 14.5 14.5 bar_g
Abrasiveness Not abrasive Temperature 205 205 205 °C
Fluid Group (PED) Normal Fluid (Fluid group 2) Density 7.7151 7.7151 7.7151 kg/m3
Fluid type Newtonian Viscosity 0.01594 0.01594 0.01594 cP
Atmospheric Pressure 1.0133 bar_a Design pressure 14.5 15.95 bar_g
Standard ASME (ANSI) (min/max)
Design temp. (min/ 205 235 °C
max)
Sound velocity 508.9 508.9 508.9 m/s

Flowmeter Sizing and Calculated Results


Flowmeter Prowirl F (Generation C) 200 Generation: 3 / minimum nominal maximum
Model: 1 Requested Flow 26 250 26 250 26 250 m3/h
Flow Principle Vortex (Prowirl) Velocity 111.2 111.2 111.2 m/s
Extended Order Code 7F2C3H-*******DA*EABSKA1+LK Velocity Max. 176.6 176.6 176.6 m/s
Meter Size 12" Pressure loss 0.95 0.95 0.95 bar
Operating range min. 509.763   m3/h Measurement error 2.1 2.1 2.1 %
Operating range min. 934.566   m3/h Mass***
(default sensitivity) Reynolds No. 2.E+7 2.E+7 2.E+7
Linear range 509.763   m3/h
Operating range max. 28 318.4   m3/h Warning(s)
Material (sensor) * SS 1.4408 / CF3M
Process connection* Cl 300 Sch.40 ASME B16.5, 316L/1.4404
Notice(s)
PED category ** : The Flowmeter is classified in Category III.
Devices in this category need to be approved
and tested to PED requirements. Message(s)

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -1/7-
Applicator®: 11.06.03 / 16.09.04
*The user is responsible for the selection of process-wetted materials
in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -2/7-
Applicator®: 11.06.03 / 16.09.04
Applicator Sizing - Flow
Project : DED PK SOYBEAN EXTRACTION PLANT
Customer: PT REKAYASA ENGINEERING C.Project No.:
Contact person: Elvis Soegianto Phone: 08119528018 Fax:
eMail: elvis.soegianto@endress.com

TAG : FT-04
Timestamp: --- Review number: ---
Sales order number:

Fluid properties sheet


Fluid
Fluid name Steam, superheated State Steam Superheated
    Calculation standard IAPWS

Fluid description
Medium character Clean
Fluid group (PED) Normal Fluid (Fluid group 2)
Fluid type Newtonian
Fluid stability Stable
Tc (Critical temperature) 374   °C Tm (Melting point) -0.01   °C
Pc (Critical pressure) 221.2   bar Tb (Boiling point) 117.8   °C
Kappa 1.29

Calculated results
Density nom. 7.7151   kg/m3 Pressure nom. 14.5   bar_g
Viscosity nom. 0.01594   cP Temperature nom. 205   °C
Sound velocity nom. 508.9   m/s
Vapor pressure nom. 17.24   bar_a
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0133   bar_a Atmospheric pressure 1.0133   bar_a

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -3/7-
Applicator®: 11.06.03 / 16.09.04
Applicator Sizing - Flow
Project : DED PK SOYBEAN EXTRACTION PLANT
Customer: PT REKAYASA ENGINEERING C.Project No.:
Contact person: Elvis Soegianto Phone: 08119528018 Fax:
eMail: elvis.soegianto@endress.com

TAG : FT-04
Timestamp: --- Review number: ---
Sales order number:

Compare sizes Sheet


General Parameters
Fluid Steam, superheated
State Steam Superheated
Character Clean Atmospheric Pressure 1.0133 bar_a
Abrasiveness Not abrasive Standard ASME (ANSI)
Fluid Group (PED) Normal Fluid (Fluid group 2)
Fluid type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flowmeter Prowirl F (Generation C) 200 Prowirl F (Generation C) 200
Generation/Device model 3/1 3/1
Flow Principle Vortex (Prowirl) Vortex (Prowirl)
Meter Size 10" 12"
Process connection* Cl 300 Sch.40 ASME Cl 300 Sch.40 ASME
B16.5, 316L/1.4404 B16.5, 316L/1.4404
Operating range min. 360.057 509.763 m3/h
Operating range max. 20 001.9 28 318.4 m3/h
Velocity at req. Flow min. 157.5 111.2 m/s
Velocity at req. Flow nom. 157.5 111.2 m/s
Velocity at req. Flow max. 157.5 111.2 m/s
Sensor velocity at req. Flow min. 248.8 176.6 m/s
Sensor velocity at req. Flow nom. 248.8 176.6 m/s
Sensor velocity at req. Flow max. 248.8 176.6 m/s
Pressure loss at req. Flow min. 1.91 0.95 bar
Pressure loss at req. Flow nom. 1.91 0.95 bar
Pressure loss at req. Flow max. 1.91 0.95 bar
Meas. error Mass at req. Flow min.*** n.a. 2.1 %
Meas. error Mass at req. Flow nom.*** n.a. 2.1 %
Meas. error Mass at req. Flow max.*** n.a. 2.1 %
Reynolds No. 2.E+7 2.E+7
Warning(s) 1. Requested max. flow too big
for flowmeter range. Please
adapt the max. flow or select
a bigger size (if available) or
select another flowmeter. 2.
Requested nom. and max.
Flow too big for flowmeter
range. Please select bigger
size (if available) select another
flowmeter. 3. Requested min.,
nom. and max. Flow too big for
flowmeter range. Please select
a bigger size (if available)
or select another flowmeter.
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -4/7-
Applicator®: 11.06.03 / 16.09.04
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -5/7-
Applicator®: 11.06.03 / 16.09.04
Applicator Sizing - Flow
Project : DED PK SOYBEAN EXTRACTION PLANT
Customer: PT REKAYASA ENGINEERING C.Project No.:
Contact person: Elvis Soegianto Phone: 08119528018 Fax:
eMail: elvis.soegianto@endress.com

TAG : FT-04
Timestamp: --- Review number: ---
Sales order number:

Chart sheet (@Nominal process conditions)


Flowmeter: Prowirl F Generation: 3 Device model: 1
(Generation C) 200
Flow Principle Vortex (Prowirl) Fluid Steam, superheated
Meter Size 12" Pressure 14.5 14.5 14.5 bar_g
Operating range min. 509.763   m3/h Operating range min. 934.566   m3/h
(default sensitivity)
Operating range max. 28 318.4   m3/h Density 7.7151   kg/m3
Viscosity 0.01594   cP

Flow rate (%) Flow rate (m3/h) Pressure loss (bar) Measurement error Mass(%)***
10 2 831.84 0.011 1.189
20 5 663.68 0.044 1.189
30 8 495.52 0.1 1.189
40 11 327.36 0.178 1.189
50 14 159.2 0.278 1.189
60 16 991.04 0.4 2.101
70 19 822.88 0.544 2.101
80 22 654.72 0.711 2.101
90 25 486.56 0.9 2.101
100 28 318.4 1.111 2.101

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -6/7-
Applicator®: 11.06.03 / 16.09.04
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 04.11.2019 11:44 PM -7/7-
Applicator®: 11.06.03 / 16.09.04

You might also like