Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A A' B B' C D E

7000 3300 2100 6700 4800


A A' B B' C D E
1800 5200 1400
F5 F1 F1
GB1 (300x500)
1
1400

C5 C1 C4
1550

1802 5198 3300 2100 6700 4799


GB17 (250x400)

PB (250x400) 650
A0 1
2900
6000

825
2200
PB
6000

GB18 (250x400) F3 F2
1550
825

GB2 (300x500)
2
2200

850
1450 C1 C7 C4 C3
F8c/c200 both
F1 F8c/c200 both F1 directions
directions
2
5050

2600
2200
GB9' (250x400)

F3
5053

F1 F2 F2 F1
GB3 (300x500)
3
2600

2200

C1 C8 C1 C8 C5
GB10 (300x500)

GB11 (300x500)

GB12 (300x500)
GB9 (300x500)

3
5050

5050
PB

4997
F1 F2 F2 F2 F1
GB4 (300x500)
4 C1 C5 C7 C1 C5
2800

F8c/c200 both 4
GB13 (300x500)

F1 F1 F1 directions
GB5 (250x400)
4'

2848
C7 C5 C4'
7000
GB19 (300x500)

4'
4200

±0.00 +2.04
F3 F4
F1 F1
7200

4302
GB6 (300x500)
5 C5 C4' C3 C8
2575
3000

5
F1 F1
GB5' (300x500)
5'

2900
C8 C5
845300 300
5'
5000

GB15 (250x400)

F4 F4
5900

F3

5000
GB7 (300x500)
6
2900

3300

C4 C4 C3
2900 3300
6

GB14 (250x400)
F8c/c200 both
directions
8000

F3 F3 F3
GB7 (300x500)
7 C2 C2 C2
GENERAL NOTES
-All dimensions are in mm except elevations.
-Use concrete quality for: date revision sign app.
project no
- lean concrete - C-5.
- foundations, columns, beams & suspended & roof slab - C-25. CDSWC
Ethiopian Construction Design
& Supervision Works Corporation
D10-001/2011
drawing no.
-Use concrete cover for : Building & Urban Design &
- slabs, staircase and wall - 20 mm.
Supervision Works Sector
ST-01/20
- columns -30mm & beams - 25mm.
- foundations - 50 mm. WOLLEGA UNIVERSITY
8000

- Reinforcement steel quality:

PROJECT
S-300 for Ø12 & below reinforcement bars. ICT COMPLEX
S-400 for Ø14 and above reinforcement bars.
- Use ordinary Portland cement ( OPC ).
- Whenever required, use distribution bar Ø 8 c/c 200 mm.

LOCATION
SHAMBU & GIMBI

PROJECT
- Provide beams under partition wall at ±0.00

SITE
F1 F1 F1 - Provide surface drainage ditch to drain water away from the structure.
GB8 (300x500)
8 C6 C6 C6
-Soilinvestigation shall be conducted befor site handover
-Assumed Allowable bearing capacity of soil for foundation design is 250kpa FOUNDATION & TRUSS LAYOUT

TITLE
2225

2225
- Remove a minimum of 500mm thick of the top soil & replace it with well compacted
compacted.
- The back fill shall be compacted to 95% of standard proctor density. DRN BY DSN BY
GB8' (250x400)
8' MUHAMMED ASRAR A. Yassin A.
SCALE DATE
For Design Team Use Only
1:100 May 2019
Type of discipline AR ST EL SN MC
2225 5400 6700 2225 CHK
Name of QCS Munir Mohammed Milkyas M/Tebeb
Signature APP
Kirub Gebreyesus
A'' D'
Date

You might also like