Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

LOOP-E

FE1-10/100BASE-T
Interface Converter
USER’S MANUAL

TIANJIN LOOP ELECTRON TECHNOLOGY CO.,LTD

Keyuan Science&Trade Building No.240 Baidi Road Nankai District Tianjin

Tel:(022)87894027 87894033

Fax:(022)87890344

Web-site:www.loopworld.com.cn

24 Tel:(022)89881024

Version:V2.0
Catalogue

1 Product Description

2 Product Features

3 Panel Illustration

1. Front Panel (Stand-alone)


2. Rear Panel (Stand-alone)
3. Front Panel (Rack-cards)

4 Product Illustration

1. LEDS Indication

2. U11 Switch Illustration

3. E1 Interface Bandwidth Settings U12 (Frame Stand-alone/ Rack-cards)

4. E1 Interface Settings U6 (Stand-alone/Rack-cards)

5. Sub-cards E1 Interface Choice (Rack-cards)

6. E1 120ohm/RJ-45 Interface Definition


1. Description

LOOP-E product series provide an economic solution to E1 network access cost, and
support FE1-to-10/100Base-T Bridge. The FE1-to-10/100Base-T Bridge supports fractional
or clear channel (32 DS0 channel) E1 WAN port transmission with HDB3 (High Density
Bipolar 3) coding.
LOOP-E series also can provide stand-alone and rack-cards. The rack cards version is for
LOOP-C 5400 Integral Access Shelf use. The Parameters and loop-back settings via DIP
Switches are available. The Multicolor LED indicators are on the front panel.

2 Product Features
E1 Interface
Line rate 2.048 Mbps ± 50 ppm
Line code HDB3
Input signal ITU G.703
Jitter ITU G.823
Framing ITU G.704
Connector 75ΩBNC/120Ω RJ45C (optional)

Bridge Interface
Data port Single Ethernet port
Physical port 802.3 10BaseT, 802.3u 100BaseTX
Self-adaptive
Connector RJ45
Bridge Function

Physical/Electrical Features
Dimensions Stand-alone:20x14x4.2cm
Power AC:165-240V DC: -48V
Temperature 0-50ºc
Humidity 0-95% (non-condensing)

3 Panel Illustration
1.Front Panel (Stand-alone)
2.Rear Panel (Stand-alone)

3.Front Panel (Rack-cards)

4. Product Illustration
1.LEDS Indication
LED Colors Illustration Indicator
POWER Green Power Bright
LOF Red Loss of E1Frame Dark
LOS Red Loss of E1Signal Dark
RAI Yellow E1 Remote Alarm Dark
CRC Red Redundancy Dark
Check-out Indicator
AIS Yellow E1 Alarm Dark
LINK Green Ethernet Indicator Bright
RxD Green Receive Data Flashing
TxD Green Transmit Data Flashing
FDX Green Full-Duplex Indicator Bright
COL Yellow Data Collision Dark

2.U11 Switch Illustration


Switch ON OFF
SW1 E1Clock Internal clock
SW2 Framing Transparent
Transmission
(2048K)
SW3 PCM31 PCM30
SW4 CRC ON CRC OFF
SW5 FDX Self-adaptive
SW6 E1Loop-back OFF
SW7 Not Use
SW8 Not Use

3.E1 Interface Bandwidth Settings U12 (Frame Stand-alone/ Rack-cards)


From 1 to 5 are binary system(from low to high),the Settings of TS are continuous.
Rates SW1 SW2 SW3 SW4 SW5
64K on off off off off
128K off on off off off
192K on on off off off
256K off off on off off
320K on off on off off
384K off on on off off
448K on on on off off
512K off off off on off
576K on off off on off
640K off on off on off
704K on on off on off
768K off off on on off
832K on off on on off
896K off on on on off
960K on on on on off
1024K off off off off on
1088K on off off off on
1152K off on off off on
1216K on on off off on
1280K off off on off on
1344K on off on off on
1408K off on on off on
1472K on on on off on
1536K off off off on on
1600K on off off on on
1664K off on off on on
1728K on on off on on
1792K off off on on on
1856K on off on on on
1920K off on on on on
1984K on on on on on

4 E1 Interface Settings U6 (Stand-alone/Rack-cards)


BNC or RJ-45 Interface (Optional)
Position BNC (Default) RJ-45
1 OFF ON
2 ON OFF
3 ON OFF
4 ON OFF

5. Sub-cards E1 Interface Choice (Rack-cards)


BNC or RJ-45 Interface (Optional)
Position BNC (Default) RJ-45
JUM3 1,2 2,3
JUM4 1,2 2,3
JUM5 1,2 2,3
JUM6 1,2 2,3

6.E1 120ohm/ RJ-45 Interface Definition


Pin Signal
1 Receive data
2 Receive data
4 Transmit data
5 Transmit data

You might also like