Professional Documents
Culture Documents
HUAWEI GSM-R BTS3900 Hardware Structure PDF
HUAWEI GSM-R BTS3900 Hardware Structure PDF
ISSUE4.0
www.huawei.com
HUAWEI Confidential
The BTS3900 developed by Huawei is an indoor macro BTS.
The BTS3900 mainly consists of the BBU and MRFUd.
Compared with traditional BTSs, the BTS3900 features simpler
structure and higher integration.
In this slide, we’ll mainly introduce the hardware system
structure, basic functions of modules and networking mode of
the BTS3900.
PSTN
MS TUP,ISUP ISDN
BTS3900 PSPDN
BSC
A Interface
MS MSC/VLR
MAP
BTS3900
BTS HLR/AUC/EIR
SMC/VM
MS
BTS3900 OMC
MS: Mobile Station BTS: Base Transceiver Station BSC: Base Station Controller
HLR: Home Location Register AUC: Authentication Center EIR: Equipment Identity Register
MSC: Mobile Switching Center VLR: Visitor Location Register SMC: Short Message Center
VM: Voice Mailbox OMC: Operation and Maintenance Center DBS:Distributed Base Station
Page 10
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
BTS3900 Logical Structure
BBU
DRFU
DCDU
PMU
PSU
FAN BOX
1 2
SW1 ON ON The E1 impedance is set to 75 Ω.
ON OFF ON OFF The E1 link of the Level 2 cascaded BTS can be bypassed.
OFF OFF ON OFF The E1 link of the Level 3 cascaded BTS can be bypassed.
ON ON OFF OFF The E1 link of the Level 4 cascaded BTS can be bypassed.
OFF ON OFF OFF The E1 link of the Level 5 cascaded BTS can be bypassed.
UPEA UPEB
EXT-ALM0 RJ45
MON0 RJ45
EXT- RJ45
ALM0
Page29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
MRFUd Board
LEDs on the Board
Power SPARE2, SPARE1, BBU, Power ports supplying the 10 outputs of power
output port FAN, and RFU5-RFU0 to the BBU, MRFUd, and fan box
Power SPARE2, SPARE1, BBU, Power switch controlling the 10 outputs for the
switch FAN, and RFU5-RFU0 BBU, MRFUd, and fan box
Ports Function
RS232/RS422 Used in communication with the central processing unit.
port
Battery switch The battery switch has two control ports ON and OFF, which are used for
switching on and switching off the battery.
Press and hold the port ON for 5-10 seconds to switch on the battery.
Press and hold the port OFF for 5-10 seconds to switch off the battery.
Power supply Two power supply test holes -48V and 0V are available for measurement
test port through an ordinary multi-meter.
COM port Used in connection to the external signal transfer board.
MRFUd Topology
The BBU and MRFUd support multiple network topologies such as star, chain, and
ring topologies.
Only optical fiber can be used between MRFUd and BBU.