Abstract: The purpose of this study is to determine wall Preserving the water quality throughout the distribution
decay coefficient (Kw) for water distribution system of system is, therefore, one of the most challenging
Dhule city using EPANET software. Dhule Municipal technological issues for suppliers. Therefore, source
Corporation has provided hydraulic data which is used in concentration must be large enough to maintain adequate
the present work. For finding out the on-site free residual residual free chlorine as minimum 0.2 mg/L (Drinking Water
chlorine in the system, chloroscope is used. Total 540 Specification IS: 10500, 2012). Chlorine disinfection
observed readings are taken on-field using chloroscope. By presents the advantages of efficiency and durability. To
comparing the observed readings with predicted values guarantee the water supply system’s disinfection, we need a
from EPANET by trial and error method, the chlorine decay residual concentration of disinfectant to prevent
coefficients are found. This type of study is useful in recontamination by pathogenic or indicator micro-
understanding the movement of foreign particles in the organisms, which can originate in the biofilm formed inside
water distribution system, to optimize the chlorine dosage the system, as well as in negative pressure areas. There is a
at the water treatment plant and water storing problem when water distribution systems have considerable
facilities, to maintain limiting 0.2 mg/L of residual chlorine proportions of chlorine residual concentration disappearing
throughout the system. along the system. Knowing the aspects behind chlorine
decay is in order if we are to develop a strategy capable of
INTRODUCTION disinfecting a water supply system and, at the same time,
Water quality is a prime concern in the world. Many preserving water quality until the point of use, without using
transmittable diseases are waterborne. Water distribution more disinfectant than necessary.
networks serve many purposes in addition to the provision Typically, chlorine is added near the final stages of drinking
of water for human consumption, which often accounts for water treatment plants to disinfect. A certain residual
less than 2% of the total volume supplied. amount is added to disinfect against any pathogens found
the inside the walls of the distribution system piping. This
People in rural areas obtain water from unprotected ponds
residual chlorine is consumed on its journey through the
or tanks, wells, cisterns and sometimes streams and rivers.
piping system and the chlorine concentration should be at
Mostly this water is unsafe for consumption. Consequently,
low concentrations at the point of consumption. Computer-
the populations suffer from frequent epidemics.
based mathematical models that are able to predict the time
The objective of any water distribution system is to make
history and the spatial distribution of constituents in water
water available to the consumer in proper quantity and
distribution networks are useful in network design and
pressure, with acceptable quality in terms of flavour, odour,
operation. Chlorine disinfectants interact with the natural
appearance and sanitary security.
organic matter in treated water to form disinfection by-
© 2017, IRJET | Impact Factor value: 5.181 | ISO 9001:2008 Certified Journal | Page 1199
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056
Volume: 04 Issue: 03 | Mar -2017 www.irjet.net p-ISSN: 2395-0072
products (DBP). Raising the pH of treated water may assist Orthotolidine solution is used in the analysis. For this, 10 ml
in controlling the corrosion but will increase the formation water sample is taken in clean glass tube. 1-2 drops of
of trihalomethanes (by products of chlorine disinfectant). orthotolidine solution is mixed in the sample. The yellow
Since the THMs are carcinogenic, this is not desirable. There colour would form if residual chlorine is present. Then, this
is a trade-off between providing enough residual to ensure tube colour is compared with the comparator tubes in the
the micro-biological safety of the water supplied, and adding chloroscope and the reading is noted down. Two sets of
too much disinfectant, which can lead to taste, odour, or by- readings are collected on each day of analysis of which one
product problems (Jea et al., 2012). Long retention times are set contains 10 readings starting from ESR to the 10th
very significant with regard to the concentrations of various selected node of the study area zone. After collection of 1st
contaminates and substances as they propagate through the set of readings which takes 1 to 1.5 hour, 2nd set of readings
system. is taken from ESR to 10th selected node.
supply (on every 4th day), taken at 10 random locations Zone, (2) Zone 5A- Nehru Nagar ESR Zone, (3) Zone 15-
where chlorine concentration is to be analyzed on-site with Kumar Nagar ESR Zone, (4) Zone 2- Mohadi ESR Zone & (5)
chloroscope. Zone 10A- Police Parade Ground ESR Zone of Dhule city are
studied and analyzed for the prediction of residual chlorine
in the water distribution system. The residual chlorine is
Analysis of Residual Chlorine
found out on site using Chloroscope instrument. The results
First the system hydraulic model (EPANET) is set up with all
obtained from the field tests and that of EPANET software
the pipe, reservoir and junction data. All the data is obtained
are calibrated and the coefficient of wall decay is obtained
from Municipal Corporation, while bulk chlorine decay
for all these zones along with the minimum initial required
coefficient is obtained from literature and some model runs.
chlorine dosage in the ESR.
Details of the network layout and hydraulics are fed to the
software. Network of the selected zone is prepared. Value of
The data obtained from observed values and that of EPANET
the bulk decay coefficient -1.0 per day is selected from the
software is calibrated to find the Kw value. This Kw value is
literatures [(Mohammed et al., 2009), (Rossman 2000)]. The
then validated by applying it to the other four zones and
wall decay coefficient is found out by trial and error method
satisfactory results are obtained.
by analyzing the residual chlorine values in the system (Toru
et al., 2008). It is done by computing least square error From literatures it is found that in most cases, the ideal
between the data obtained from observed values and calibration is to be done by comparing the predicted and
software predicted values. These coefficients are applied for observed data by use of Root Mean Square Error Method
the other zones also for their validation purpose and (RMSE).
satisfactory results are obtained. Water samples are
The predicted values for all zones are obtained by varying
periodically collected on the day of water supply, taken at 10
the value of Kw as -0.45/day, -0.50/day, -0.55/day, -
random locations of the zone where chlorine concentration
0.60/day and Kb= -1/day is kept same for all zones.
is to be analyzed on-site with chloroscope.
© 2017, IRJET | Impact Factor value: 5.181 | ISO 9001:2008 Certified Journal | Page 1200
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056
Volume: 04 Issue: 03 | Mar -2017 www.irjet.net p-ISSN: 2395-0072
,
Table 5: RMSE obtained for Zone 2
where n= number of readings in a set,
Kw, Kb -0.44, -1 -0.51, -1 -0.54, -1 -0.60, -1
y = observed reading
% RMSE 5.42 5.22 5.23 5.21
y^ = predicted reading
Table 1: RMSE obtained for Zone 14 Thus, from the above data, the value of coefficient of wall
decay Kw= -0.55/day is determined for the Dhule City.
Kw, Kb -0.44, -1 -0.51, -1 -0.54, -1 -0.60, -1
Kw, Kb -0.44, -1 -0.51, -1 -0.54, -1 -0.60, -1 understanding for movement of water within
distribution system.
% RMSE 3.46 3.12 2.94 3.0 EPANET incorporated first order model is found to
be satisfactory in terms of prediction of residual
chlorine.
Once the hydraulic and water quality model set up
and properly calibrated, we can rely on EPANET
predictions.
© 2017, IRJET | Impact Factor value: 5.181 | ISO 9001:2008 Certified Journal | Page 1201
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056
Volume: 04 Issue: 03 | Mar -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 5.181 | ISO 9001:2008 Certified Journal | Page 1202
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056
Volume: 04 Issue: 03 | Mar -2017 www.irjet.net p-ISSN: 2395-0072
10. Grayman, W.M., Clark, R.M. and Males, R.M., 1988, Journal Water Resources Planning and
Modeling Distribution System Water Quality: Management, ASCE, 114(2).
Dyanamic Approach, Water Resources Planning and 20. Mohammed, S.S., Abdullah, I.A. and Mayada, H.M.,
Management, ASCE, 114(3), 295-311. 2009, Simulation of Chlorine Concentrations in Mosul
11. Hallam, N.B., West, J.R., Forster, C.F., Powell, J.C. and University's Distribution Network Using EPANET
Spencer, I., 2002, “The Decay of Chlorine Associated Program, Al-Rafidain Engineering, Vol.17, No.6.
with the Pipe Wall in Water Distribution Systems,” 21. Monteiro, L., Fugueiredo, D., Dias S., Freitas, R.,
Water Research, Vol. 36, No. 14, pp. 3479-3488. Covas, D., Menaia, J. and Coelho, S.T., 2013, Modeling
12. Hossein, S., Jaafar, O. and Basri, N.E., 2013, of Chlorine Decay in Drinking Water Supply Systems
Disadvantage of Pressure Changes on Decline of using EPANET MSX, 12th International Conference
Water Quality in Water Distribution Systems, Journal on Computing and Control for the Water Industry,
of Scientific Research, Vol. 5, 97-105. 1192 – 1200.
13. Indian Standard Drinking Water Specification, 2012, 22. Ozdemir, O.N., Sevuk, S. and Ger, A.M., 2000, A
2nd Revision IS: 10500. Chlorine Decay Simulator in Water Supply Networks,
14. Ingeduld, P., Pradhan, A., Svitak, Z. and Terrai, A., Turk Journal of Engineering Environmental Science
2006, Modeling Intermittent Water Supply Systems Vol. 24, 401-412.
with EPANET, 8th Annual Water Distribution 23. Ozdemir, O.N. and Ger, A.M., 1998, Realistic
Systems Analysis Symposium. Numerical Simulation of Chlorine Decay in Pipes,
15. Islam, M.R., 1997, Inverse Modeling of Residual Water Research Journal, Vol. 32, No. 11, pp. 3307-
Chlorine Concentration in Pipe Network under 3312.
Dynamic Conditions, Journal of Environmental 24. Pedro, C. and Neves, M., 2003, Application of first-
Engineering, ASCE 123(10), 1033-1040. order kinetics to model chlorine decay, using EPANET
16. Islam, M.R., 1998, Modeling of Constituent Transport software on a real network, for calibration,
in Unsteady Flows in Pipe Networks, Journal of Environmental 2010: Situation and Perspectives for
Environmental Engineering ASCE 124(11), 1115- the European Union, Porto, Portugal.
1124. 25. Rossman, L.A., 2000, EPANET 2 User’s Manual, U.S.
17. Jae, C.A., Lee, S.W., Choi, K.Y. and Koo, J.Y., 2012, Environmental Protection Agency, Water Supply
Application of EPANET for the determination of and Water Resources Division National Risk
chlorine dose and prediction of THMs in a water Management Research Laboratory, EPA-600/R-
distribution system, Sustainable Environment 00/057.
Resources, 221, 31-38. 26. Rossman, L.A., 1994, Modeling Chlorine Residual in
18. Kowalska, B., Kowalski, D. and Musz, A., 2006, Drinking Water Distribution System, Journal of
Chlorine Decay in Water Distribution System, Journal Environmental Engineering ASCE 120(4), 803-821.
of Environment Protection Engineering, Vol. 32, No. 27. Sadiq, R. and Rodriguez, M.J., 2004, Disinfection by-
3. products (DBPs) in drinking water and predictive
19. Males, R.M., Grayman, W.M. and Clark, R.M., 1988, models for their occurrence: a review, Science of the
Modeling Water Quality in Distribution Systems, Total Environment, Vol. 321, No. 1-3, pp. 21-46.