JT.1 ACC.
JT.2 NO INDICATION FOUND ACC.
JT.3 DURING INSPECTION TIME ACC.
SIGNATURE : SIGNATURE :
DYE PENETRANT INSPECTION & MAGNETIC PARTICLE INSPECTION REPORT
PROJECT T4MS REPORT NO: STSEDAC/DPI/PCP/20/001
CLIENT PETRONAS
REFINERY AND PETROCHEMICAL
CORPORATION SDN BHD (PRPC) DATE: 1/19/2020
SPEC
ASME Section V Nondestructive Examination LOCATION: PCP UNIT 12
MATERIALSTAINLESS STEEL WELDING PROCESS GTAW
CONDITIONCLEAN MATERIAL THICKNESS 4.78mm
PWHT N/A DRAWING NO: MY1008-12LDH05-&MTC030-480214
MAGNETIC PARTICLE INSPECTION DYE PENETRANT TEST
BACKGROUND: NA REMOVER SKC-S Magnaflux
MAGNETIC INK: NA DYE PENETRANT SKL-SP2 Magnaflux
APPARATUS NA DEVELOPER: SKD-S2 Magnaflux
CURRENT: NA METHOD: Colour Contrast
METHOD: NA CURRENT: NA
SUMMARY OF RESULT
IDENTIFICATION INSPECTION FINDING ACCEPT/REJECT REMARKS
JT FW4 ACCEPT
JT FW5 NO INDICATION FOUND ACCEPT
JT SW5A DURING INSPECTION TIME ACCEPT
JT FW1 ACCEPT
DATE DATE
SIGNATURE SIGNATURE
DYE PENETRANT INSPECTION & MAGNETIC PARTICLE INSPECTION REPORT
PROJECT T4MS REPORT NO: STSEDAC/DPI/PCP/20/001
CLIENT PETRONAS
REFINERY AND PETROCHEMICAL
CORPORATION SDN BHD (PRPC) DATE: 1/19/2020
SPEC
ASME Section V Nondestructive Examination LOCATION: PCP UNIT 12
MATERIALSTAINLESS STEEL WELDING PROCESS GTAW
CONDITIONCLEAN MATERIAL THICKNESS 4.78mm
PWHT N/A DRAWING NO: MY1008-12LDH05-&MTC030-480214
MAGNETIC PARTICLE INSPECTION DYE PENETRANT TEST
BACKGROUND: NA REMOVER SKC-S Magnaflux
MAGNETIC INK: NA DYE PENETRANT SKL-SP2 Magnaflux
APPARATUS NA DEVELOPER: SKD-S2 Magnaflux
CURRENT: NA METHOD: Colour Contrast
METHOD: NA CURRENT: NA
SUMMARY OF RESULT
IDENTIFICATION INSPECTION FINDING ACCEPT/REJECT REMARKS
JT FW4 ACCEPT
JT FW5 NO INDICATION FOUND ACCEPT
JT SW5A DURING INSPECTION TIME ACCEPT
JT FW1 ACCEPT
DATE DATE
SIGNATURE SIGNATURE