INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 

Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

Analysis and Design of Underpass RCC Bridge 
Mohankar.R.H 1 , Ronghe.G.N 2 
1­ Lecturer, Civil Engineering Dept., G.H Raisoni College of Engineering, Nagpur, India. 
2­ Professor, Applied Mechanics Dept., Visvesvaraya National Institute of Technology, 
Nagpur, India 
roshanmohankar@gmail.com 

ABSTRACT 

The Underpass RCC Bridge is very rarely adopted in bridge construction but recently the 
Underpass RCC Bridge is being used for traffic movement. In this paper, the analysis of 
the  underpass  RCC  bridge  is  carried  out. The  analysis  of  this  underpass  RCC  bridge  is 
done  by  considering  fixed  end  condition.  Finite  Element  Method  (FEM)  analysis  is 
performed and results are presented. Comparison of different forces between 2D and 3D 
models  for  fixed  end  condition  is  provided.  In  this  study  we  show  a  2D  model  can  be 
effectively  used  for  analysis  purpose  for  all  the  loading  condition  mentioned  in  IRC:  6, 
“Standard  Specifications  and  Code  of  Practice  Road  Bridges”  The  Indian  Roads 
Congress and Directorate of bridges & structures (2004), “Code of practice for the design 
of substructures and foundations of bridges” Indian Railway Standard. 

Keywords: RCC Underpass bridge, FEM analysis. 

1.  Introduction 

The Underpass RCC Bridge is very rarely adopted in bridge construction but recently the 
Underpass RCC Bridge is being used for traffic movement. This underpass RCC bridge is 
pushed  inside the embankment by  means of hydraulic  jack system Since the availability 
of  land  in  the  city  is  less,  such  type  of  bridge  utilizes  less  space  for  its  construction. 
Hence  constructing  Underpass  Bridge  is  a  better  option  where  there  is  a  constraint  of 
space or land. Detailed analysis and design of underpass RCC bridge has not been carried 
out till date. Ronghe G. N. and Gatfane Y. M (2004­2005) have worked on the analysis 
and design of 2D underpass RCC bridge model. 
In  this  paper  2D  along  with  3D  analysis  of  underpass  RCC  bridge  is  carried  out 
considering  six  different  loading  conditions  and  eight  different  loading  combinations 
which are considering from IRC: 6­2000, “Standard Specifications And Code Of Practice 
Road  Bridges”  The  Indian  Roads  Congress  and  Directorate  of  bridges  &  structures 
(2004),  “Code  of  practice  for  the  design  of  substructures  and  foundations  of  bridges” 
Indian Railway Standard. The end condition is considered to be fixed for both 2D and 3D 
underpass RCC bridge model. 

1.1 Modeling of system 

For the study of Underpass RCC bridge, earth pressure acting on side walls of underpass 
RCC bridge because structure embedded as well as vertical loading due to imposed load

558 
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 
Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

and  live  load  from  Bridge  rules,  “Rules  specifying  the  loads  for  designing  the  super­ 
structure and sub­structure of bridges and  for assessing the strength of existing bridges” 
(Indian  Railway  Standard  code)  on  the  top  of  underpass  RCC  bridge  is  considered.  As 
there  is  a  top  loading,  there  is  reaction  at  bottom  also.  This  underpass  RCC  bridge  is 
provided  for  city  traffic  also.  For  that  purpose  live  load  from  IRC:  6­2000  inside  the 
underpass RCC bridge is considered. 
Vertical 

Earth  Earth 
Pressure due  Pressure due 
to backfill  to backfill 

Reaction at bottom

Figure 1:  2D Model of RCC Underpass Bridge 

2D underpass RCC bridge model shown in Figure 1 is analyzed considering without soil 
structure interaction. 

Figure 2: 3D Model of RCC Underpass Bridge 
3D underpass RCC bridge model shown in figure 2 is analyzed considering without soil 
structure interaction. 

559 
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 
Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

2. Formulation 

2.1 Loads on the top of slab 

Total  load  for  bending  moment  and  shear  force  is  considered  from  IRS  code  rules 
specifying the loads for designing the super­structure and sub­structure of bridges and for 
assessing the strength of existing bridges. For span of 8m total load for bending moment 
981kN and total load for shear force is 1154kN is considered. 
Dead load of earth fill over the box = Area x depth x density  ­­ 1.1 
Total vertical pressure on top slab = Imposed load + Dead load + Live load  ­­ 1.2 

2.2 Loads on sidewalls 

The  coefficient  of  active  earth  pressure  of  the  soil  is  given  by  the  equation
cos 2  (f  - a )
Ka =  2 
æ sin  (f + d ) - sin  (f - i ) ö
cos  a ´ cos  (a + d ) ´ çç 1 +

÷
è cos  (a - d ) - cos  (a - i ) ÷ø
­­ 1.3 
where, 
γ = Density of soil, ф = Angle of internal friction, d  = angle of friction between wall and 
earth fill 
Where value of d  is not determined by actual tests, the following values may be assumed. 
(i) d  = 1/3 ø for concrete structures. 
(ii) d  = 2/3 ø for masonry structures. 
i  =  Angle  which  the  earth  surface  makes  with  the  horizontal  behind  the  earth  retaining 
structure 
( i =0 0 for embedded structure). 
Since  this  concrete  structure  is  embedded  in  soil,  the  value  of d  is  considered  as  1/3  ø 
(for concrete structures) considered for calculation of coefficient of active earth pressure 
of the soil. 

2.3 Earth pressure acting on the sidewalls: 

2.3. a) Earth pressure due to backfill 

Earth pressure center of top slab =  Ka ´ g  ´ H  ­­ 1.4 
Earth pressure center of bottom slab =  Ka ´ g  ´ H  ­­ 1.5 

2.3. b) Earth pressure due to dead load surcharge 

Earth pressure acting on sidewalls: 
At Top = Imposed load of track + Earth pressure on the top of slab + Live load  ­­ 1.6 
AT Bottom = Horizontal effect of surcharge + Earth pressure center of bottom slab  ­­1.7

560 
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 
Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

2.4 Reaction at the bottom of box 

Self weight of box = Weight of top slab + Weight of bottom slab 
+ Weight of side walls  ­­ 1.8 
Total reaction at bottom=Self weight of box +Weight of imposed load 
+Weight of live load  ­­ 1.9 
The boundary condition considered is fixed. 

3. Analysis of 2D underpass RCC bridge model 

A  2D  underpass  RCC  bridge  (Figure  1)  is  modeled  considering  1m  length  for  the 
following  details  shown  below.  Box  dimensions:  1mx7.5mx4.1m  (LxWxH)  (Center  to 
center).  In  addition  to  the  dimensions  mentioned  in  Figure  3,  following  parameters  are 
considered  for the 2D analysis.  Keeping all the parameters same, the analysis  is carried 
out  using  two  methods  viz.  conventional  slope  deflection  method  (manual  calculations) 
and  other  by  using  SAP2000  (programming  software).  The  manually  calculated  values 
for the bending moment at corner A is 205kN­m and corner C is 302kN­m for dead load 
case. For the same corners A & C, the SAP results are found to be 203kN­m and 298kN­ 
m respectively. 

7.5 m 

0. 
A  B 

4.1 
4.7 3.5 

C  D 

0.6 

7 m 
0.5  0. 
(a)                                                                          (b) 
m  5 

Figure 3: (a) Center to center Dimensions of RCC Underpass Bridge 
(b) Dimensions of RCC Underpass Bridge 

Dimensions of underpass RCC bridge 
Clear horizontal opening  7 m 
Clear vertical opening  3.5 m 
Slab thickness  0.6 m 
Wall thickness  0.5 m 
Outer to outer horizontal width  8 m 
Outer to outer vertical height  4.7 m 
Length underpass RCC bridge      1 m 
Angle of internal friction (ф)  25 o 
Density of soil (γ)                          19 kN/m 3 
Grade of concrete  M40 

561 
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 
Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

Grade of steel  Fe415 
The max BM and SF obtained for 2D underpass RCC bridge model considering without 
soil  stiffness  are  shown  in  Table  1.  Shear  force  and  bending  moment  diagram  after 
analysis is shown in Figure 4 (a) & (b) 

(a)  (b) 

Figure 4: (a) SF diagram for 2D Analysis  (b) BMD For 2D Analysis 

3.1 Validation of results 

The bending moment results obtained by slope deflection method and SAP2000 program 
for  2  dimensional  model  of  underpass  RCC  bridge  are  approximately  same.  The  slight 
variation of results may be due to the variation of moment of inertia values. Based on this 
validity of results further analysis of same 2D model for various combinations of loading 
cases was carried out. Also  it was observed that was the same corners of the 3D  model 
the bending  moment results obtained were same  and  hence 3D analysis was carried out 
using SAP2000. 

Table 1: Max BM and Max SF of 2D 

Max BM & Max SF of 2D model 
Member  Results 
without soil stiffness (kN­m) 
Max SF  456.33 
Top 
BM ­ Mid Span  572.72 
Slab 
BM ­ Corner  339.94 
Max SF  259.92 
Bottom 
BM ­ Mid Span  372.73 
Slab 
BM ­ Corner  147.11 
Max SF  79.68 
Side 
BM ­ Mid Span  204.67 
Walls 
BM ­ Corner  339.94

562 
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 
Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

3.2 Analysis of 3D underpass RCC bridge model 
A 3D underpass RCC bridge is modeled considering total length 13m with details shown 
above and there is no change in details except length. Box dimensions: 13mx7.5mx4.1m 
(LxWxH) (Center to center).The max BM and SF obtained for 3D underpass RCC bridge 
model considering without soil stiffness are shown in Table 2. 

Table 2: Max BM and Max SF of 3D 

Max BM & Max SF of 3D model 
Member  Results 
without soil stiffness(kN­m) 
Max SF  458.85 
Top Slab  BM ­Mid Span  530.49 
BM ­Corner  413.63 
Max SF  282.49 
Bottom 
BM ­ Mid Span  377.87 
Slab 
BM ­ Corner  154.14 
Max SF  78.93 
Side 
BM ­ Mid Span  220.74 
Walls 
BM ­Corner  413.63 

4. Comparison of Result of 2d & 3d Underpass Rcc Bridge Model 


The  comparison  of  the  maximum  bending  moment  and  shear  force  values  obtained  for 
2D and 3D underpass RCC bridge models which are considered without soil stiffness are 
compared. The comparison between these two results (Table 3) shows that the values of 
bending  moment and shear  force for 2D and 3D  model  for all  loading cases considered 
for  the  analysis  purpose  from  IRC:  6­2000,  “Standard  Specifications  and  Code  of 
Practice Road Bridges” The Indian Roads Congress and combinations, are approximately 
same. 

Table 3: Comparison of Max BM and Max SF of 2D model and 3D model of the box 

Comparison of Max BM of 2D & 3D model without soil stiffness 
Max BM of 2D  Max BM of 3D 

Member  Results  model without soil  model without soil 
Difference 
stiffness (kN­m)  stiffness (kN­m) 
Max SF  456.33  458.85  0.55 
Top Slab  BM ­Mid Span  572.72  530.49  ­7.96 
BM ­ Corner  339.94  413.63  17.82

563 
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING 
Volume 1, No 3, 2010 
© Copyright 2010 All rights reserved Integrated Publishing services 
Research article  ISSN   0976 – 4399 

Max SF  259.92  282.49  7.99 


Bottom 
BM ­Mid Span  372.73  377.87  1.36 
Slab 
BM ­Corner  147.11  154.14  4.56 
Max SF  79.68  78.93  ­0.95 
Side 
BM ­Mid Span  204.67  220.74  7.28 
Walls 
BM ­ Corner  339.94  413.63  17.82 

5. Conclusions 
From the analysis  it can  be observed that bending  moment and shear  force obtained  for 
2D  and  3D  model  are  approximately  same.  A  2D  model  can  be  effectively  used  for 
analysis  purpose  for  all  the  loading  condition  mentioned  in  IRC:  6  and  Directorate  of 
bridges  &  structures  (2004),“Code  of  practice  for  the  design  of  substructures  and 
foundations of bridges” Indian Railway Standard. Further research is needed to verify the 
use  of  2D  model  for  different  parameters  such  as  dynamic  analysis,  soil  structure 
interaction etc. 

6. REFERENCES 
1. Ronghe G.N. And Gatfane Y.M. "Analysis And Design Of A Bridge By A Push Back 
System.” A Dissertation of M.tech In structural Engineering. 2004­2005. 

2. Directorate of bridges & structures (2004), “Code of practice for the design of 
substructures and foundations of bridges” Indian Railway Standard. 

3. IRC: 21­2000, “Standard Specifications And Code Of Practice Road Bridges” The 
Indian Road Congress. 

4. IS 456:2000, “Plain and Reinforced concrete code for practice” Bureau of Indian 
Standards. 

5. IRC: 6­2000, “Standard Specifications And Code Of Practice Road Bridges” The 
Indian Road Congress. 

6. IRC: 8­2000, “Design criteria for pre­stressed concrete road bridges (Post­Tension 
concrete)” The Indian Roads Congress.

564 