WORKPLACE RISK ASSESSMENT

Area/Unit/Department: Confined Space / #001 / Hot Work. Completed by: Nico Fernando J Review date: 18.06.2018

Activity: Welding and Maintenance inside the confined space. Date: 18.03.2018

Hazards Who might be harmed What is already being Are further Additional Actions Priority
and how done to control the risk? controls
needed?
It affects mainly the Workers were regularly Prior permit to work should be
Working inside the confined space without attendant and the trained and competent to issued by the issuing authority
proper gas testing and permit to work. workers (welder, work inside the confined Yes and proper gas testing before 1
helper) might inhale space. starting the work.
toxic gas, fire and
explosion.

The workers (fire Breathing apparatus were Blow air system should be used
Accumulation of fumes while doing hot watcher, welder) provided to the workers and nitrogen purging should be
work inside the confined space. working inside the inside the confined space. Yes done to restrict fumes. 8
confined space are in
risk inhalation of toxic
fumes might result in
respiratory and
breathing problems.

Persons inside the Limited time exposure of Usage of adequate exhaust fans
Working under excessive temperature due to confined space (helper, workers and job rotations to eliminate heat using
poor ventilation inside the confined space. welder) will be affected were induced, hydration Yes mechanical ventilation. 4
by heat burns, heat made available outside
strokes and the confined space. Valid 3rd party certificate must be
asphyxiation. obtained.
Mainly it affects the A worker assigned near Proper proceeding of
Absence of proper isolation of utilities i.e. welder inside the the controls to ensure no Yes Lockout/Tagout should be done
electrical cables and pipes inside the confined space causing one activates it. to isolate electrical pipes & 3
confined space. electrocution, flash cables before starting the work.
burns and nervous Competent workforce must be
breakdown. employed.
Workers inside the Fire rescue team has been The whole watcher should be
Confined space attendant was not deployed confined space (welder, deployed outside the deployed outside the confined
outside the confined space area. fire watcher) are in risk confined space. Yes space and log sheets must 5
of several injuries i.e. maintain the access and egress
fire burns, toxic gases entering the confined space.
inhalation.
The foreman, welder, A robust command and Only the person who’s well
Untrained workers i.e. entrants involved in work-watcher can be safe system of work were trained and competent should
the confined space activity. affected leading to practised, proper Yes enter the confined space. 6
injury, burns on the barricades were installed. Necessary warning signs must be
skin. kept in place.

Mainly it affects the Mechanical lifting The necessary emergency


No emergency arrangements like tripod, welder; fire-watcher systems were deployed in equipment should be provided
breathing apparatus, emergency response working inside the the case of crew rescue. Yes i.e. Safety harness, respiratory
team & fire extinguishers were provided enclosed area and breathing apparatus etc. before 2
near the confined space area. might lead to fatality. entering the confined space.

Persons working inside Proper emergency lights Usage of non-spark tools and
240V were used for lighting arrangements the confined space (i.e. and personal torch lights low voltage equipment of 12V
inside the confined space. welder, fire watcher, were provided. Yes lights should be implemented 7
charge-hand) were inside the confined space.
spark might lead to fire Workers using only
explosion or electric approved electrical Proper training about the dangers
leak may lead to applications. and proper usage of equipment’s
electrocution. must be given.
The welder and helper Permit to work and gas The welding process should be
110V equipment’s were used for welding may be seriously testing had been carried done between 20-100V,
purposes inside the confined space area. injured/fatality if they out and grounding had Yes minimum is 50V inside the
perform work without been maintained. confined space.
proper gas testing and
electrocution of Fire extinguishers are Welding should be inspected and
improper equipments provided within 2feet third party sticker should be
while working inside reach. available.
the confined space
area.
Workers working on Workers were working Proper life line ropes, rescue
Working at height inside the confined space heights might lead to on proper platform; team should be deployed outside
slip, trip, and fall scaffoldings are tied Yes while working inside the
causing bone fracture, properly, maintained and confined space.
several injuries to checked regularly.
welder, foreman and Safety net must be installed.
helper.
Close supervision must be done
by the scaffoldings supervisor
and proper tag should be
maintained often.