VITZRO TECH Air Circuit Breaker is a circuit breaker that passed new
premium circuit breaker that is convenient to use with a design that enables
Performance
It provides a stable image and an excellent
breaking performance.
The front part and mechanism part of the product
are molded using an insulator to increase the safety of
operators.
The reliability of the product is enhanced based on a
precise configuration and an excellent breaking
capacity.
It is easy to perform maintenance using an overheat
alarm function that detects the temperature of Busbar
(R, S, T, N).
It has a superior switch performance and an excellent
durability.
A1-03
Air Circuit Breakers
Easy Compact
It is easy to perform maintenance and the parts It ensures a sufficient space for customers using
are compatible. a compact and lightweight device.
The mechanism part and auxiliary device are It is a compact product that is optimized for package
modularized for easy maintenance. panel system.
An overheat burn prevention function is built-in An external size is reduced to 80% of the existing
through a Shunt Coil. product which allows loading of 3 LV boards.
The parts are closely connected which enables a
convenient maintenance of users.
Product Guide
Item Specification
Rated Current 630 ~ 4000A
Breaking Capacity 65 ~ 100kA
Operation Method Motor operation, Manual operation
Voltage AC400V, AC690V
Installing Method Draw-out Type, Fixed Type
Trip Method Multifunction Trip Under-voltage Trip, Shunt Trip
Number of Poles 3P, 4P
Standard IEC60947-2, KSC4620
A1-04
maintain various systems and compatibility that more than meets the
protective function that provides the best convenience for users since it can
Intelligent Convenience
It is designed in a safe and convenient It enhanced the users’ convenience and safety.
configuration by applying an Intelligent Trip Device.
The terminal box of the control circuit is attached to
It is easy to distinguish a trip state using a LED of the the front part.
Intelligent Trip Device. A draw-out rail guide is tremendously improved for
an easy draw-out.
It satisfies the requirements of an intelligent control
center and automation system such as a remote It is equipped with an intelligent protection function,
measurement, a remote control and so forth since it a function to select the high-precision setting and a
has a standard RS485 communication interface of the reliable power supply.
Intelligent Trip Device. Its reliability is improved using the meter and
applying the highly-precise current detecting circuit.
It enhanced the reliability and convenience through
digitalization(conversational setting) and Korean
language support of over-current protective device.
9
2
3
10 11
5 4
8 12 7 6
10 11 12 13
5
14
15
6
16
8
Air Circuit Breaker is equipped with the following functions to safely use the
Basic Operation
CB wires so as to not only protect the loading part equipments, but also to
prevent accidents including fire and human damages.
Circuit Closing
A closing operation of mechanism provides the current to the load. When the current is
applied through the closing operation, some loads generate far larger inrush current
than the rated current (In). (That is, a motor becomes 7~8In for several seconds)
The closing should be operated promptly in order to prevent any damages (damages
due to Arc) due to this inrush current which is dangerous at the contact. If the circuit
breaker meets the standard, it should endure the current that is 15~20 times bigger
than the rated current and it should be opened quickly when failures occur during
closing or after closing.
Current Conducting
A current conducting within the rated current should not exceed the allowable
temperature and during an over-current conducting, the conducting should be safely
performed till the breaking time. Furthermore, if the circuit breaker is used for a
selective breaking, the downstream circuit breaker should be designed to endure a
high electromagnetic repulsion force so that it can allow a short circuit current during
the breaking time.
Circuit Opening, Current Breaking
A current breaking can be generated through an optional operation of mechanism
(through manual and remote control).
With the current conducting, the circuit breaker will be operated automatically using an
auxiliary trip device (under voltage trip device, ground trip device and etc) to open the
circuit safely.
Although the circuit breaker maintains the closing Position based on OCR when the
over-current is generated, it shall be automatically operated to open the circuit safely.
Isolation
When the circuit breaker is opened, it requires a Specific Isolation Level between the
Charge part and Discharge part.
Maximum Leakage Current Test between Input and Output under the rated voltage
(Max, Ue)
Impulse Voltage
CE Certification Mark
Certification
CE Mark represents that all duties are met for the products manufactured according to
the EU instructions. CE Mark shows the decision of the manufacturer or the authorized
representative who complied with the suitable preparations including the product
evaluation process.
A1-10
Rating
690V/600V/550V kA 50
Rated Ultimate Short Circuit
500V/480V/460V kA 65
Breaking Capacity Icu
415V/380V/230V/220V kA 65
Fixed Type mm 41 / 53 41 / 53 41 / 53 43 / 55
Weight (3P/4P)
Draw-out Type mm 65 / 84 65 / 84 65 / 84 68 / 84
A1-11
Air Circuit Breakers
690V/600V/550V kA 65 85
Fixed Type mm 43 / 55 45 / 58 48 / 62 59 / 77 65 / 83
Weight (3P/4P)
Draw-out Type mm 68 / 88 70 / 92 75 / 95 90 / 117 98 / 125
A1-12
Trip Relays
Appearance
•L / S / I / G
Current Relay •L / S / I / G
•ZSI(Selective Breaking)
Additional Relay - •Leakage(Selectable)
Measurement Function - •Current(R/S/T/N)
•Self Power
- Power runs when 20% of the load
•Self Power current is In
Power - Power runs when 20% of - External power used during the
the load current is In communication
•AC/DC 110~220V
•DC24~48V
LED
Displays the trip data and overload
status
TRIP
When the current load is over 113%,
it flickers; when CB trips, it is turned
ON and when turned OFF, it is switched
off.
A1-14
Trip Relays
❶ LED
Indicator Trip data and Overload status
1 PTA(Pre Trip Alarm) : Overload Protective Relay DO Output
LTD(Long Time Delay) : Indicators Long Time Delay Relay Operation
STD/INST(Short Time Delay/Instant) : Indicators Short Time Delay &
2 Instantaneous Delay Operation
GFT/ELT: Indicators Ground Fault Operation
Alarm : Overload warning alarm (Turned On when 90% or more,
Flickering The full note cannot be seen)
❷ LED
3 Indicator measurement and data of each RSTN phase
4 ❸ Reset Key
5 Reset after OCR relay operation, Reset after Battery Check
❹ S/I
6
Isd : Short Time Delay Current Setting,
7
Tsd : Short Time Delay Time Setting,
8 li : Instantaneous Time Current Setting
❺ LTD
Ir : Long Time Delay Current Setting,
Tr : Long Time Delay Time Setting
❻ MENU
Initial screen, Move between setting menus
❼ Move Cursor
Move to Menu or Reset : Left/Right Move of screen cursor or setting
❽ Enter
Move to Lower Menu or Input Setting
A1-15
Air Circuit Breakers
Operating Characteristics
Long Time Delay Protection
Time delay(s) Tr@(1.5xIr) 12.5 25 50 100 200 300 400 500 600 750
Accuracy. ±15% Tr@(6xIr) 0.5 1 2 4 8 12 16 20 24 30
or below 100ms Tr@(7.2xIr) 0.34 0.69 1.38 2.7 5.5 8.3 11 13.8 16.6 21
Time delay (s) Settings I2t off 0.5 0.1 0.2 0.3 0.4
@10xIr I2t on 0.1 0.2 0.3 0.4
Time delay(ms)at10xIr Tsd(max resettable time) 20 80 160 255 340
(I2t OffI2tOn) Tsd(max break time) 80 140 240 345 460
Time delay (s) I2t off 0.05 0.1 0.2 0.3 0.4
@1xIn I2t on 0.1 0.2 0.3 0.4
Tg(max resettable time) 20 80 160 255 340
Tg(max break time) 80 140 240 345 460
Leakage Protection (option)
Current Setting (A) Ig 0.5 1 2 3 5 10 20 30 OFF
Leakage (GFT)
OCR
Characteristics •A function to protect leakage; optional function
•When the leakage current is above the set value, it shall be broken after the time delay
Standard Current Setting Knop : Ig
- Setting Range: 0.5-1-2-3-4-5-10-20-30-Off(A)
Leakage (GFT)
- Trip Time : 140-230-350-800ms
- Alarm Time : 140-230-350-800-950 ms
External CT used and exclusive for ZCT
Necessity of using external CT
- Internal CT Type (Basic Type): Ground Fault Protection Protect 20%~100%
of the ACB rated current
- In case of a large-capacity ACB, the ground fault operating current will also
increase, which requires no ground fault] protection function. For example,
in case of 4000A ACB, the minimum ground fault relay current is
4000A x 20% = 800A.
- Thus, an external CT shall be installed to control the ground sensitivity
current, and it is optional to protect the ground fault (leakage).
ZSI (Zone elective A Zone Selective Interlocking function is intended to protect the load
Interlocking) equipments when the fault current is generated. It minimizes the delay time
and reduces damages to the air circuit breaker and load equipments for the
safety.
An ACB that executes the ZSI outputs the ZSI signal in order for the lower level
equipment to delay the operation of the upper level equipment under a short-time
delay or a ground fault.
The OCR (Over-Current Relay) of the ACB located at the fault spot performs an
instantaneous trip without time delay to remove the fault.
The upper level ACB that received the ZSI fault signal performs an operation based
on theshort-time delay or groundfault delay time setting in the system set for
protection. However, the upper level ACB that did not receive the ZSI fault signal from
the lower level ACB will carry out an instantaneous trip without time relay.
For the ZSI to operate normally, the operating time for protection should be properly
set so that the lower level ACB precedes the upper level ACB when the over-
current/short-time/ground fault load signal is input.
ZSI Input
①
② ZSI Input
ZSI Output
In case of a Fault A
- ACB① independently performs the instantaneous trip.
In case of a Fault B
- ACB② performs the instantaneous trip and ACB① delays till the set time,
then perform the instantaneous trip.
- If ACB② cannot break the fault current (ZSI signal not output), ACB① performs
the instantaneous trip to protect the system.
A1-19
Air Circuit Breakers
Set Current
A1-20
OCR Trip Characteristic Curve
Set Current
A1-21
Air Circuit Breakers
Rated Current
A1-22
OCR Trip Characteristic Curve / Control Circuit Diagram
Set Current
Control Circuit
Wiring Diagram
57<7: +TW[QVO
5IQVKQZK]Q\ ,QOQ\IT\ZQXZMTIa )]`QTQIZaKWV\IK\[ +WUU]VQKI\QWV
+PIZOM +WQT
=><
<ZQX+WQT
Air Circuit Breakers
A1-23
A1-24
Accessories
Wire Specification
•Power consumption of about 200VA, rated voltage (Vn) DC 24~30(V), DC/AC 48(V) trip coil used
•Recommended maximum wire length
Rated Voltage(Vn)
Wire Type DC 24~30(V) DC/AC 48(V)
#16AWG(1.31㎟) #18AWG(0.823㎟) #16AWG(1.31㎟) #18AWG(0.823㎟)
Operating 100% 80m 45m 330m 200m
Voltage 85% 45m 27m 210m 120m
Closing coil(CC)
•Controller closed externally
•When the voltage is supplied to A1, A2 of both coil ends with voltage input at 200ms instanta
neous time
•CB closing is completed when the coil operates
Closing Coil Rated Voltage & Characteristics
Rated Voltage(Vn) Operating Voltage Range(V) Power Consumption(VA or W) Trip
DC(V) AC(V) Pick up Drop out lnrush) Steady-state Time(ms)
24~30 -
48~60 48
50ms or
100~130 100~130 0.65~0.85Vn 0.4~0.6Vn 200 5
under
200~250 200~250
- 380~480
* Note The operating voltage range is the minimum rating range of each rated voltage (Vn)
Wire Specification
•Power consumption of about 200VA, rated voltage (Vn) DC 24~30(V), DC/AC 48(V) trip coil used
•Recommended maximum wire length
Rated Voltage(Vn)
Wire Type DC 24~30(V) DC/AC 48(V)
#16AWG(1.31㎟) #18AWG(0.823㎟) #16AWG(1.31㎟) #18AWG(0.823㎟)
Operating 100% 30.5m 18m 155m 95m
Voltage 85% 25m 15m 135m 80m
A1-25
Air Circuit Breakers
Accessories Motor(M)
•External operating power is used to charge the CB closing spring
•Manual charging, if there is no external power
•Operating Voltage Range: Voltage 85%~110%
Input Power(V) DC 24~30V AC/DC 48~60V AC/DC 100~130V AC/DC 200~250V AC 380~480V
Motor Load Current 5A 3A 1A 0.5A 0.3A
Motor Rotation(RPM) 16,000~19,000 rpm
Insulated Withstand Voltage 2kV/min
Start Load Current(max.) Less than 5 times of the load current
Insulated Withstand Voltage 2kV/min
Operating Temperature Range -20℃~60℃
Durability 20,000 cycles (Load Continuous Operating Times : 2times/mi
Charge Time 5sec or more
Charge End Contact 15A at 250V AC
Accessories
3P 4P
3P 4P
3P 4P
3P 4P
3P 4P
LOAD
3P 4P
LOAD
VITZRO TECH Air Circuit Breaker Class 1E for Nuclear Power Plants is produced through a
nuclear power quality certification system and development tests were conducted
based on KEPI END 1000~3000. In addition, it was recognized for its superior quality via
passing development tests based on ANSI C37, 13(1990) and KEPIC EED 1200.
Utility
Its performance was certified through a nuclear
power test based on an international standard
certification.
international standard certification.
It was internationally recognized for its performance
by obtaining major domestic and overseas standard
certifications including a local nuclear power test
(KERI) and an overseas KEMA certificate
(IEC60947-2 Test).
Nuclear Power Performance Verification
(KEPIC END 1000 - 3000)
- Aging analysis - Operation Cycling Test
- Seismic Test
A1-31
Air Circuit Breakers
Safety Reliability
ACB for nuclear power plants can be used within It is enhanced with the reliability by adopting a high-
the range of 3 poles and 800AF~3200AF and it functional microprocessor over-current trip device.
provides various options.
Number of Poles(P) 3
Rated Frequency 60 Hz
30kArms(Sym.)
Instantaneous Operation
Rated Short Circuit 35.1kArms(Asym.)
Breaking Current
Short Time Operation 30kArms(Sym.)
Seismic Performance Ⅰ
Weight 98kg
Number of Poles(P) 3
Rated Frequency 60 Hz
50kArms(Sym.) 65kArms(Sym.)
Instantaneous Operation
Rated Short Circuit 58.5kArms(Asym.) 76.1kArms(Asym.)
Breaking Current
Short Time Operation 50kArms(Sym.) 65kArms(Sym.)
Seismic Performance Ⅰ
Rated Operation Times (Under Rated Load) 2,000 times 1,000 times
9 Test
Terminal
3 Short Time
7 Reset Button 1 Indicator Lamp 2 Long Time
External Configuration
❻
❶ Charging handle
❷ Close/Open indicator ❶
❸ Key-lock
❹ Position indicator ❷ ❼
❺ Open button
❻ Counter ❸ ❽
❼ Spring charged indicator
❹ ❾
❽ Key-lock
❾ Racking screw & shutter ❺ ❿
❿ Close button
Internal Configuration
❶ Upper Cover
❷ Control Terminal
❸ Auxiliary Switch
❹ Closing/Trip Coil
❺ Charge handle
❻ Mechanism
❼ Charge gear
❽ Front Mold cover
❾ Draw in/out Device
❿ Arc Chamber
Moving Contact
Fixed Contact
Cradle
Clip
CB Connecting Conductor
Load Part Conductor
A1-37
Air Circuit Breakers
Draw-Out Location
Test Connected
A main circuit is disconnected, a control A main circuit and a control circuit are
circuit is connected and an operation test connected.
on a circuit breaker is possible.
Instantaneous It is used at
Lock in open type
a trip during
Type (Open impossible)
a power
(≤ 0.15sec) Applied to OCR OCR
failure or
draw-out type Alarm Contact External Contact
used as a
Delay Type Lock in close type
rectifier (for
(≥ 0.5sec) (Open impossible)
DC power).
Under Voltage Trip (UVT) automatically trips the ACB when the control power is
Under Voltage Trip
dropped below the working voltage. When the voltage is recovered up to the pick-
up voltage, The re-closing of ACB is possible. UVT consists of a trip device and a
under voltage trip controller. A coil is built inside the ACB and UVT Controller is
installed in the body (fixed type) or in the left side of the draw-out type.
There are an instantaneous-type and a delay-type to be used based on its purpose.
Rating
Rating Voltage Working Voltage Operating
Type Remarks
50-60Hz Drop Voltage Pick-up Voltage Time
Circuit Diagram
Trip Coil
Driving
Power
AC Power
Power
Control
Comparator
* Note) 1. Combined use of under voltage trip and voltage trip is possible.
2. * marked AUX.SW is not installed and do use the 1a contact of AUX.SW.
3. A1 and A2 are Test contacts and a-contact at pick-up state.
800/2000A
For Nuclear Power
Plant
Rating A B C D E
800A 330 15 85 330 275
2000A 465 25 130 465 410
Terminal Dimension
3200A
Terminal Dimension
A1-42
Certification
A1-43
Air Circuit Breakers