6 Unit area per person for waiting areas or standing rooms. 0.28 sqm.
10 Minimum spacing of rows of seats from back to back for a public assembly building. 0.83 mtr.
13 Standard width of a seat without dividing arms for places of assembly. 60 cms.
15 Minimum headroom created by any projection from the ceiling. 2.00 mts.
17 Minimum dimension of landings in direction of travel for class A & B stairs. 112 cms.
19 Minimum height of a handrail above the upper surface of the tread. 76 cms.
26 Maximum rise of any floor from the balcony floor to which an access door leads. 20.3 cms
28 Minimum width of a fire escape stair for existing stairs. 55.9 cms.
29 Minimum width of landing for a fire escape stair for existing stairs. 55.9 cms.
30 Minimum tread for a fire escape stair for small buildings. 15.25 cms.
31 Maximum rise of fire escape stair for a small building. 30.5 cms.
1/54
PREPARED BY:
ALEXANDER SAN ANDRES
32 Maximum rise of fire escape stair for existing stairs. 22.9 cms.
33 Maximum height between landings for a fire escape stair for existing stairs. 3.66 mts.
34 Minimum headroom clearance for a fire escape stair for existing stairs. 2.13 mts.
35 Minimum headroom clearance for a fire escape stair for small buildings. 1.98 mts.
56 Rooms where baled, bundled or piled materials segregated into desired sizes or groups. Picking rooms.
58 Buildings or structures used for the storage of explosives, shells, projectile, etc. Explosive magazine
An air compartment or chamber to which 1 or more ducts are connected and which form
59 Plenum
part of an air distribution system.
60 A kind of stable explosive compound which explodes by percussion. Fulminate
61 Descriptive of any substance that ignites spontaneously when exposed to air. Phyrophoric
A material that readily yields oxygen in quantities sufficient to stimulate or support
62 Oxidizing material
combustion.
2/54
PREPARED BY:
ALEXANDER SAN ANDRES
63 A process where a piece of metal is heated prior to changing its shape and dimension. Forging
The process of first raising the temperature to separate the more volatile from the less
64 volatile parts and then cooling and condensing the result vapor so as to produce a Distillation
nearly purified substance.
A finely powdered substance which, when mixed with air in the proper proportion and
65 Dust
ignited will cause an explosion.
66 Temperature rating at flash point. 37.8 oC (100 oF)
68 The temperature at which a liquid is transformed or converted into vapor. Boiling Point
74 Minimum height of fence for a lumber yard for exterior storage of lumbers. 1.80 mts.
75 Maximum width of sumps for the retention of oil and petroleum products. 3.70 mts.
76 For Refineries, distilleries, and chemical plants, the minimum height for a fence. 1.50 mts.
Minimum travel distance from any individual room subject to occupancy by not more 6
77 15.00 mts.
persons.
78 Maximum distance of travel from the high hazard area to an exit. 23.00 mts.
Minimum distance of an incinerator from any structure used other than a single family
79 3.00 mts.
dwelling.
80 Maximum reduction in width of a stair by a handrail. 9 cms.
88 Minimum stair width for a class B stair serving an occupant load of less than 50. 91 cms.
Length of a nosing or effective projection over the level immediately below it for tread
89 25 mm
below 25 cms in dimension.
90 Maximum height of a handrail. 86.5 cms.
91 A combustible liquid is any liquid having a flash point at or above. 37.8 oC (100 oF)
The time duration that a material or construction can withstand the effect of standard
92 Fire resistance rating
fire test is known as.
3/54
PREPARED BY:
ALEXANDER SAN ANDRES
96 Under what classification of occupancy does home for the aged fall. Institutional
102 Minimum clear width of aisles for a Class 'A' store. 1.50 mts.
103 Minimum clear width of an exit access through a covered mall. 3.66 mts.
105 Standard inner radius of a curved stair in business occupancies. 763 cms.
108 Minimum width of stair for Class 'B' stairs serving more than 50 persons. 112 cms.
109 Minimum width of stair for Class 'B' stairs serving 50 persons and below. 91 cms.
111 Minimum width of a stair width for Class 'A' stairs. 25 mm.
112 Maximum height between landings for a Class 'B' stairs. 3.70 mts.
113 Minimum width of landings in direction of travel for Class 'A / B' stairs. 112 cms.
117 Maximum height between landings for Class 'A' ramp. No limit
118 Maximum height between landings for Class 'B' ramp. 3.66 mts.
120 Minimum width for fire escape for existing stairs. 55.9 cms.
Minimum horizontal dimension of any landing of platform for existing stairs for fire
121 55.9 cms.
escape.
122 Maximum rise for a fire escape for very small buildings. 30.5 cms.
123 Maximum height between landings for fire escape for existing stairs. 3.66 mts.
4/54
PREPARED BY:
ALEXANDER SAN ANDRES
124 Minimum distance travel to an exit for storage occupancies of high hazard commodities. 23 mts.
129 A continuous and unobstructed route of exit from any point in a building to a public way. Means of Egress
130 Minimum distance of an incinerator containing kindled fire or rubbish fire or bonfires. 5.00 mts.
132 Under what classification of occupancy does town halls fall? Business
134 Minimum tread for a fire escape stair for existing stairs. 22.9 cms.
135 Maximum spacing of rungs for a fire escape ladder. 30.5 cms.
139 Minimum space from the back of chair to the front of the chair behind. 30 cms.
140 Maximum slope for aisles for public assembly structures. (1:8) 12.5%
141 Size of standpipe provided for each stage for public assembly building. 63.5 mm.
146 Maximum height from the floor for a rescue window for educational occupancies. 82 cms.
147 Minimum width of corridors, aisles, and ramps for exits in hospitals and nursing homes. 2.44 mts.
148 Minimum width of corridors, aisles, and ramps for exits in residential-custodial care. 1.83 mts.
Any room for sleeping in institutional occupancies if subdivided shall have a maximum
149 465 sqm.
area of how many square meters?
Includes buildings or groups of building under the same management in which there are
150 Hotel
more than 15 sleeping accommodations for hire.
Includes buildings containing three or more living units independent cooking and
151 bathroom facilities, whether designed as rowhouse, apartment house, tenement, garden Apartment Buildings
apartment, or by any other name.
5/54
PREPARED BY:
ALEXANDER SAN ANDRES
152 Minimum number of stories of apartment buildings requiring fire alarm system. 3
COMBUSTIBLE
158 Free burning fiber (cotton, oakum, hay, straw, etc.) FIBER
COMBUSTIBLE
159 Liquid w/ flash pt. ^37.8 deg.C (100deg.F) LIQUID
CORROSIVE LIQUID
160 Liquid w/c causes fire when in contact w/ organic matter/chemicals
Extremely hot, luminous bridge formed by the passage of electric current across a
167 Electrical Arc
space between 2 conductors due to the incandescence of the conducting vapor
168 Hot piece or lump partially burned, still oxidizing w/o the manifestation of flames Ember
Design & installation of walls, barriers, windows, vents, means of egress; treatment of FIRE SAFETY
176 building components with flame retardant chemicals; to minimize danger of fire and safe CONSTRUCTIONS
evacuation of people.
6/54
PREPARED BY:
ALEXANDER SAN ANDRES
177 Minimum temperature a material gives off vapor to form ignition Flashpoint
178 Metal is heated prior to changing shape/dimension Forging
179 Stable explosive compund; explodes by percussion Fulminate
HAZARDOUS
manufacturing, fabrication, conversion w/c uses/produces materials that cause fires or OPERATIONS/PROC
180
explosions. ESS
Passageway from one building to another or through or around the wall in HORIZONTAL EXIT
181
approximately same floor level.
182 Box/cabinet where fire hoses, valves and other equipment ware stored. Hose BOX
183 Cylindrical device where fire hose is wound and connected Hose Reel
HYPERGOLIC FUEL
184 Rocket or liquid propellant
INDUSTRIAL BAKING
Industrial process of heating materials to remove solvents/moisture, and fuse certain
185 & DRYING
salts to form uniform glazing on the surface of treated materials
186 Piece of metal or conductor used to bypass a safety in an electrical system JUMPER
OCCUPANCY
187 Intended use/purpose of a building
Any person occupying/using a building (or portions) by virtue of lease
188 OCCUPANT
contract/permission with the owner/administrator
Strong oxidizing organic compound w/c causes fire when in contact w/ combustible
189 Organic Peroxide
material under condition of high temperature.
Use of electrical appliances/devices beyond the designed capacity of existing electrical
190 Overloading
system.
191 Person who holds the legal right of possession or title to a building/property Owner
192 Yields oxygen; stimulates/supports combustion OXIDIZING
PRESSURIZED/FORC
Type of burner where pressurized fuel is discharged to combustion chamber which ED DRAFT BURNING
193
includes fans for introduction of air. EQUIPMENT
PUBLIC ASSEMBLY
194 building/structure; 50 or more people congregate/gather/assemble BUILDING
195 street, alley, strip of land unobstructed from ground to sky intended for public use Public Way
PYROPHORIC
196 Ignites spontaneously when exposed to air
197 partial distillation & electrolysis; removing impurities/deleterious materials from mixture Refining
198 Automatic closing doors; confines smoke & heat; delays spread of fire. SELF-CLOSING
199 Melting/fusing metal ores; separate impurities from pure metals. Smelting
Integrated network of hydraulically designed piping with outlets w/c automatically
200 Sprinkler system
discharges water when activated by heat.
Vertical pipes to which firehoses can be attached on each floor; includes system where STANDPIPE SYSTEM
201
water is made available to outlets as needed.
VESTIBULE
202 Passage hall/antechamber between outlet doors and interior parts of building
VERTICAL SHAFT
203 Vertical space/passage extending from floor to floor, base to top of the building
AUTOMATIC FIRE
Integrated system of underground or overhead piping connected to extinguishing agent SUPPRESSION
204
actuated by automatic detecting device to suppress fire. SYSTEM
7/54
PREPARED BY:
ALEXANDER SAN ANDRES
213 pipes not filled with water; water is introduced thru Fire Service connections Dry Standpipe
EXPLOSIVE
Building, structure or facilities used for the storage of explosives, shells, projectile and
214 MAGAZINE
ammunition
FIRE ALERTING
Fire alarm system transmitted to designated locations instead of sounding a general
215 SYSTEM
alarm to prevent panic
FIRE PROTECTIVE
An assembly incorporated in a structure designed to prevent the spread of fire
216 ASSEMBLY
(dampers, curtain board, fire stoppers)
FIRE RESISTANCE
217 Time duration a material can withstand the effect of hundred fire test RATING
A wall designed to prevent the spread of fire w/ fire resistance rating of not less than 4
218 FireWall
hours and structurally stable.
219 Time w/c flame will spread over the surface of a burning material. Flame Spread Rating
220 Compound/mixture w/c improves fire resistant quality of fabrics and other materials FLAME RETARDANT
HAZARDOUS FIRE
Land covered with dry grass, cogon, reeds, brush and other highly combustible growth
221 AREA
that fires are likely to occur and hard to suppress.
HIGHRISE BUILDING
222 Buildings, structures, facilities 15 meters or more in height.
Continuous unobstructed route of exit from any point in a building, structure or facility to MEANS OF EGRESS
223
a public way.
Maximum number of persons that may occupy a building, structure or facility or portions
224 OccupantLoad
thereof.
Liquid mixture of binders (alkyd, acrylic…) w/c when spread on surface becomes ORGANIC COATING
225
protective and decorative finish.
Mechanical device consisting of linkages and a horizontal bar across a door, which
PANIC HARDWARE
226 when pushed from the inside will cause the door to open and facilitate exit from a
building, structure or facility.
Rooms where baled, bundled or piled materials are segregated into desired sizes or PICKING ROOMS
227
groups.
Air compartment or chamber w/ one or more ducts are connected to form part of an air
228 plenum
distribution system.
SMOKE DEVELOPED
229 density and volume of smoke developed within a certain period of time. RATING
1 HOUR FIRE
230 PROTECTIVE ENCLOSURE OF EXITS - 3 STORIES OR LESS RESISTANCE
RATING
2 HOUR FIRE
231 PROTECTIVE ENCLOSURE OF EXITS - 4 STORIES OR more RESISTANCE
RATING
8/54
PREPARED BY:
ALEXANDER SAN ANDRES
min. horizontal dimension – not less than 2.00m / - inner courts shall be connected to a Size & Dimensions of
234
street or yard, or by a passageway – 1.20m min. Courts
a. Natural Ventilation – min of 2.70m
Artificial Ventilation (min.)
1st storey 2.70m
235 2nd storey 2.40m Ceiling Heights
3rd storey 2.10m
b. Mezzanine – min. of 1.80m
1. Rooms for Human Habitations – 6 sq.m w/ at least dimension of 2m (2x3m)
2. Kitchens – 3 sq.m w/ a least dimension of 1.5 (1.5x2m) Size and Dimension
236
3. Bath & Toilet – 1.20 sq.m w/ at least of 0.90m (0.90x1.3m) of Rooms
1. School Rooms – 3.00 cu.m w/ 1.00 sq.m of floor area per person Air Space
2. Workshops, Factories, Offices – 12.00 cu.m of air space per person; Requirements in
237
3. Habitable rooms – 14.00 cu.m of air space per person. Determining the Size
of Rooms
– eaves over required windows not less than 750mm. minimum over from the side &
238 rear property lines / – sum of areas of openings must not exceed 50 % of sum of areas Location on Property
of walls
239 at least 10% of floor area (not provided w/ artificial ventilation system) Window Openings
a. Ventilation or vent shafts – horizontal cross-sectional area not < 0.10 sq.m per meter
height of shaft
240 Vent Shafts
b. Air Ducts – 0.30 sq.m w/ at least dimension of 300mm
1. Office, Administrative purposes – not < 3 changes of air per hour
2. Bakeries, Hotel, Restaurants, Kitchens – not < 10 changes of air per hour
3. Auditoriums, Assembly purposes – not < 0.30 cu.m of air per minute Minimum Reqt’s in
241
4. Wards, Dormitories of Institutional Bldgs. – not < 0.45 cu.m of air per minute, Air Changes
supplied each person
a. Footings – at least 2.40m below grade along national roads, may project not >
300mm beyond Property line.
Projection into Alleys
242 b. Foundations – not < 600mm below the grade, may encroach 500mm into public
or Streets
sidewalk areas
9/54
PREPARED BY:
ALEXANDER SAN ANDRES
– not less than 2.40m above pavement or GL shall not, when fully opened, project
246 Doors & windows
beyond PL except fire exit doors
a. Public Street or alley less than 3.60m in width shall be truncated at the corner
“Chaflan” Corner Bldgs. with
247
b. If arcaded bldg, no chaflan reqtd notwithstanding the width of public street, 12.00m Chaflans
1. Access – not < 600mm sq. or in diameter, min clear headroom of 800mm
2. Area Separation – enclosed attic space of combustible construction shall be divided
Roof Construction
253 into horizontal area max of 250 sq.m. area, 750 sq.m. in area for attic with Fire-
and Covering
extinguishing system.
10/54
PREPARED BY:
ALEXANDER SAN ANDRES
1. Every storey, basement or cellar w/ 200sq.m or more w/c is used for habitation, etc.
w/c has an occupant load of more than 20.
2. Dressing, rehearsal rms., workshops or factories w/ occupant load of more than 10 or
Fire-Extinguishing
256 assembly halls w/ occupant load of more than 500, if the next doors of rooms are more
Systems
than 30.00m from safe dispersal area.
3. Photographic x-ray, nitrocellulose films and inflammable articles
11/54
PREPARED BY:
ALEXANDER SAN ANDRES
1. Size – Interior wet standpipes deliver 190 liters/water per minute under 2.0 kg per
sq.cm water pressure
2. Outlets – 38mm valve each storey located not < 300mm nor more than 1.20m above
the floor.
258 3. Water Supply – street main not < 100mm in diameter c. Wet Standpipes
4. Pressure and Gravity Tanks – 1500 liters/water per minute for not < 10 minutes
5. Fire pumps – capacity not < 1000 liters per minute w/ pressure not < 2 kg per sq.cm
connected to street main w/ not < 100mm diameter
1. Sheds, greenhouses, and the like not exceeding 6sq.m. in floor area
2. Building Permits
2. Addition of open terrace/patios not exceeding 20sq.m
(Exceptions)
3. Window Grilles
259 a. Minor
4. Garden pools for water plants/aquarium not exceeding 500mm in depth.
Constructions:
5. Erection of garden walls other than walls not exceeding 1.80m
12/54
PREPARED BY:
ALEXANDER SAN ANDRES
1. Width
1.1 Sidewalks of 2m w/ planting strip of 800mm in width separating curb & sidewalk
1.2 Arcades shall be cantilevered from bldg. line, horizontal distance bet the curb line &
the outermost face of bldg not < 500mm
1.3 Combined open & arcaded sidewalks w/ planting strip not < 800mm in width
separating bet arcaded portion and open portion of sidewalk
262 Arcades & Sidewalks
2. Driveways, Entrances and Exits
2.1 Entrances and Exits of Building abutting sidewalks shall be made of either ramps or
steps
2.1.1 Steps shall have treads not < 300mm. Min no. of steps shall be (2), w/ risers not
exceeding 100mm
1.1. Primary Lines – min vertical clearance of 10m from the crown of road pavement, 1. Location of Poles
7.5m from the top of the shoulder/sidewalk and Clearances of
263
1.2. Secondary Lines – min vertical clearance of 7.5m from the crown of road pavement Power Lines along
Public Roads.
2. Clearance of
a. Fire Hydrants – not < 5m Supporting
264 b. Curbs – not < 150mm from curb away from the roadway Structures such as
Poles, Towers and
others
a. Clearances Over Roof – Conductors have clearance not< 2.5m from highest pt. of 3. Clearance of
265
roofs Service Drops
4.1 New Building – load demand 200KVA or above provided w/transformer vault
4.2 Location – ventilated to outside air
4.3 Walls, Roof and Floor. Reinforced concrete not < 150mm, masonry/brick not less
Provisions for
266 than 200mm, 300mm load bearing hollow concrete blocks. Inside wall and roof surface
Transformer Vaults
constructed of HCB shall have a coating of cement/gypsum plaster not < 20mm.
Concrete floor not < 100mm thick.
6.1 Transformers Used w/ Capacitors – KVA rating shall not be < 135% of capacitor
268 Capacitors
rating
1.1 Hoistway pits clearance of not < 600mm remains bet the underside of car & bottom
of pit.
1.2 Min number of hoisting ropes shall be 3 for traction elevators and 2 for drumtype
elevators.
269 1.3 Min diameter of hoisting & counterweight ropes shall be 30mm Elevators
1.4 Elevators w/ over-load relay and reverse polarity relay.
1.5 In high rise apts. or residential condos of more than 5 stories, at least 1 passenger
elevator shall be kept on 24 hour constant service.
2.1 Angle of inclination shall not exceed 35 degrees from the horizontal
2.2 Width bet balustrades shall not be < 558 mm nor more than 1.20m. The width shall
270 not exceed the width of the steps by more than 330mm. Escalators
2.3 Rated speed, not more than 38mpm.
13/54
PREPARED BY:
ALEXANDER SAN ANDRES
3.1 Location
3.1.1 Main Bldg. is not made up of fire resistive materials, boilers shall be located
outside w/ distance not < 3.00m outside the wall of main bldg. & bldg. housing the boiler
3.1.2 No part of the boiler shall be closer than 1m from any wall
3.2 Smokestacks - shall able to withstand a wind load of 175km per hour & shall rise at
least 5m above the eaves of any bldg. w/in a radius of 50m.
3.3 Boilers more than 46sq.m. heating surface shall be provided w/ 2 means of feeding Boilers & pressure
271
water, 1 steam driven and 1 electrically driven, 1 pump and 1 injector. Vessels
3.4 2 check valves shall be provided bet any feed pump and boiler
3.5 Boilers rms. shall have at least 2 separate exits.
3.6 Each boiler shall at least 1 safety valve. Having more than 46.sq.m pressure of
water heating surface/generating capacity exceeding 97kg. per hour, 2 or more safety
valves are required.
4.1 68-74 degrees F temperature and humidity for comfortable cooling, 4.57 to 7.60
MPM temperature at an air movement.
4.2 Not more than 136kgs of refrigerant shall be stored in a machine rm.
4.3 Where ammonia is used into a tank of water at least 1 gallon of water shall be
Refrigeration and Air
272 provided for every .04536kg of ammonia in the system.
Conditioning
4.4 Refrigerant piping crossing a passageway in any bldg. shall not < 2.3m above the
floor.
4.5 Window type AC (Air Con) shall not be < 2.13m from the ground
5.1 To maintain water pressure in all floors of a bldg./structure, the ff. systems may be
used:
5.1.1 Overhead tank supply – may be installed above the roof w/ a vent and an 5. Water pumping for
273
overflow pipe leading to a storm drain and be fully covered. Bldg./Structures
5.1.2 Pneumatic Tank – unfired pressure vessel
6.1 Piping 100mm in diameter and above shall be flanged. Small diameter pipes – may
be screwed
6.2 Color coding of Piping:
Steam Division High Pressure – White
Exhaust System – Buff
Water Division Fresh Water, low pressure - Blue
Fresh Water, high pressure - Blue
Salt water piping – Green
274 Pipings
Oil Division Delivery – Brass or Bronze
Discharge – Yellow
Pneumatic Division All piping Gray
Gas Division All piping – Black
Fuel Oil Division All piping – Black
Refrigerating Division Pipes – Black
Fittings - Black
275 erected @ sidewalks/walkways not < 2.40m in height above curb line. Fence
4.1 Protective canopy - 2.40m above the walkway
4.2 Railings – not < 1m high and solid toe boards not < 300mm placed along the street
and ends of the canopy. Canopy safely sustaining a load of 800kg per sq.m.
276 Canopy
4.3 Underside of canopy properly lighted not < one (1) 100 watt bulb every 6m of its
length
5. Protective
277 G.I wire gauge 16,38mm mesh nylon net; canvas
Nets/Screen
14/54
PREPARED BY:
ALEXANDER SAN ANDRES
6.1 Temporary walkway adjacent to the street line not more than 1.20m wide (for the
use of pedestrians). Where the road right of way is 5m or less, no temporary walkway
shall be allowed
6. Walkways &
278 6.2 Width of walkway shall not < 1.20m but more than 1/3 the width of the sidewalk.
Railings
6.3 Walkways capable of supporting uniform live load of 650kg per sq.m.
6.4 Railings – not < 1m in height
7.1 Every Trench, 1.50m or more in depth, provided w/ means of exit at least 7.50 of its 7. Precautionary
279
length Measures
8.1 No materials piled/stacked higher than 1.8m except in yards/sheds. When Piles 8. Storage of
280
exceed 1.2m height, material be arranged that the sides & ends of the piles taper back. Materials
9.1 All buildings – 1 standpipes outlet @ each floor.
9.2 In every construction – at least 1 approved handpump, tank or portable chemical or
dry fire extinguisher.
281 9. Fire Protection
9.3 No material/construction equipment shall be placed w/in 3m of such
hydrant/connection bet it and the center of the street.
10.1 Where more than 200 workers are employed, a properly first-aid room shall be 10. Sanitation & First
282
provided w/ a physician/nurse. Aid
11.1 Passageways, stairways and corridors – average light intensity not < 2 foot
candles. 11. Temporary Light
283
11.2 Locations where tools & or machinery are used – 5 foot candles. & Power
284 shall be screened/protected on all sides not < 1.80m height 12. Hoist Towers
16.1 Used as hoistways/elevator shaftways be protected all sides, expect the side used
for loading & unloading. Protection shall be in barricades not < 1.20m high near the
288 edges of openings, guard rails not < 910mm high placed not < 600mm. Floor Openings
16.2 Solid barriers not < 910mm high
15/54
PREPARED BY:
ALEXANDER SAN ANDRES
18.1 Chutes for removal of materials & debris shall be provided in demolition operations
w/ are more than 6m above pt. of material to be removed
18.2 Intervals of 7.60m or less w/ substantial stops to prevent descending matl’s
18.3 Chutes w/c at an angle 45 degrees from the horizontal be enclosed on all 4 sides
290 18.4 Chutes w/c at an angle 45 degrees from the horizontal may be left open on the 18. Chutes
upper side
18.5 Openings into matl’s/debris are dumped are dumped at the top of a chute shall be
protect by a substantial guardrail extending @ least 1.90m above the level of the floor
unoccupied space bet bldg. lines & lot lines other than yard: free, open and
unobstructed from the ground upward.
a. Inner court – bounded on all sides/around its periphery by bldg. lines.
b. Open court – bounded by 3 sides by bldg. lines w/ 1 side bounded by another open
space
c. Through court – bounded on 2 opposite sides by bldg. lines w/ the other opposite
sides bounded by other open space.
292 Courts
• Every court shall have a width not < 2.00m for 1 and 2 storey bldgs. This may
reduced to not < 1.50m in cluster living units (quadruplexes, rowhouses) for 1 or 2
storeys in height w/ adjacent courts w/ area not < 3.00m. Irregularly shaped lots like
triangular shall be < 3.00m
• Bldgs more than 2 storeys in height, min width of the court shall be increased at the
rate of 300mm
2.1 Mixed occupancies, parking requirements shall be the sum of 100% dominant use &
2. Parking
50% of each of the non-dominant
294 Requirement
2.2 20% of parking requirements may be provided w/in premises
Computation:
2.40x5.00m
perpendicular or
295 Average automobile parking size
diagonal,
2.00x6.00m for
16/54
PREPARED BY:
ALEXANDER SAN ANDRES
1. Public Buildings
2. Traditional Indigenous Family
Exemptions of Bldg.
299 Dwellings – native materials
Permit
Cost doesn’t exceed P15,000
National Building
301 P.D.. 1096
Code
303 Minimum spacing for seats in a chair type measurement from back to back. 0.85 mtr.
306 In standard seating, the minimum spacing of rows measured from back to back. 0.84 mtr.
17/54
PREPARED BY:
ALEXANDER SAN ANDRES
Minimum number of exit for floors above the first storey having an occupant load of
312 2
more than 10
315 Maximum floor area for an attic made of combustible materials. 250.00 sqm
316 Maximum center to center spacing of a draft curtain sprinkler. 1.80 mts.
317 Maximum floor area for an attic made of incombustible materials. 750.00 sqm.
324 Minimum air space between walls of a masonry chimney above the roof. 2" / 50 mm
326 Maximum rise of one row of seat to the next. 400 mm / 0.40 mtr.
327 Minimum number of exit for stands within a building serving an occupant load of 300. 3
328 Minimum height of a guard rail located in front of the grandstand. 0.90 mtr
18/54
PREPARED BY:
ALEXANDER SAN ANDRES
330 Minimum spacing for seats with backrests measured from back to back. 0.75 mtr.
331 Minimum spacing for seats without backrests measured from back to back. 0.60 mtr.
336 Minimum width of an aisle serving only one side. 800 mm / 0.80 mtr.
337 Open space requirement for an interior lot. 50% of lot area
338 Open space requirement for a corner lot or a through lot. 10% of lot area
339 Bounded on all sides or around its periphery by building lines. Inner court
344 Air space requirement for a school room per person. 3.00 cum.
345 Air space requirement for a habitable room per person. 14.00 cum.
346 Minimum area of opening of an air duct. 300 sqmm / 0.30 sqm
Maximum projection beyond the property line of a footing along the national road and at
347 300 mm
least 2.40 mts. In depth.
348 Minimum clearance of a canopy or a marquee from the sidewalk. 3.00 mts.
349 Minimum stair width for occupant load of less than 50. 0.90 mtr.
19/54
PREPARED BY:
ALEXANDER SAN ANDRES
352 Vacant space left between the building and lot lines less than 2.00 mts in width. Setback
354 Minimum width of a passageway connecting a street and a court. 1.20 mts.
355 Standard air space requirement per person for factories. 12.00 cum.
357 Air supply per person per minute for auditoriums. 0.30 cum
358 Minimum total area of a window or an opening for a room without artificial ventilation. 10% of flr. Area
360 Minimum horizontal clearance of the curb line to the outermost edge of the marquee. 300 mm
361 Minimum clearance of the lowest portion of an awning to the ground. 2.40 mts.
363 Minimum live load bearing capacity of a construction canopy. 600 kgs./sqm.
365 Minimum wind load capacity for roofs for vertical projection. 120 kgs./sqm.
366 Maximum height of a handrail above the stair thread. 0.90 mtr.
367 Minimum ceiling height for naturally ventilated rooms. 2.70 mts.
368 Minimum height of a handrail above the stair thread. 0.80 mtr.
20/54
PREPARED BY:
ALEXANDER SAN ANDRES
375 Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose. 6.00 mts.
377 Minimum extension of a proscenium wall above the roof. 1.20 mts.
385 Minimum distance of a sign from any electrical post or telephone wires. 1.00 mtr.
386 Minimum open space requirement for a corner lot. 10% of lot area
388 Maximum slope for an entrance or exit ramp. One is to ten (1:10)
21/54
PREPARED BY:
ALEXANDER SAN ANDRES
395 Maximum distance of a handicapped parking from the facility being served. 60.00 mts.
1:50 sqm. Of
397 Theaters, cinemas, auditoria, and stadia parking ratio.
spectators' area
Minimum number of wheelchair seating space for 51-300 seating capacity for
398 4
auditoriums.
401 Maximum distance of an accessible elevator from the entrance of a building. 30.00 mts.
402 Minimum height of signs on walls and doors for the disabled to see comfortable. 1.40 mts.
404 Minimum dimensions for an accessible water closet stall. 1.70 X 1.80 mts.
405 Maximum height of signs on walls and doors for the disabled to see comfortably. 1.60 mts.
406 Minimum width of a parking slot for the disabled. 3.70 mts.
408 Minimum ceiling height from 3rd floor to succeeding floors with artificial ventilation. 2.10 mts.
414 Maximum width reduced by handrails and doors fully opened to balconies and corridors 200 mm
415 Minimum width of stairs serving more than 50 occupants. 1.10 mts.
22/54
PREPARED BY:
ALEXANDER SAN ANDRES
417 Maximum reduction in width of a stair due to trims and handrails. 100 mm
423 Maximum number of seats between the wall and the aisle. 7
424 Maximum distance between the back of each seat to the front of the seat behind it. 300 mm
426 Maximum projection of a penthouse or other projections above the roof. 8.40 mts
427 Maximum ratio of a penthouse area to that of the supporting roof. one third (1/3)
429 Minimum thickness of rubble stone masonry chimney for residentials. 300 mm
432 minimum thickness of front and side smoke chamber walls. 200 mm
433 Minimum number of storeys requiring one (1) or more dry standpipes. 4
434 Minimum volume of water a dry standpipe should provide. 900 liters/minute
435 Diameter of a dry standpipe requiring a two-way Siamese connection. 4" (100mm)
436 Diameter of a dry standpipe requiring a three-way Siamese connection. 5" (125mm)
437 Diameter of a dry standpipe requiring a four-way Siamese connection. 6" (150mm)
438 Minimum volume of water an interior wet standpipe should provide. 190 liters/minute
23/54
PREPARED BY:
ALEXANDER SAN ANDRES
442 Maximum distance of a hose nozzle to any portion of a building. 6.00 mts.
444 Maximum projection into a sidewalk of a sign 4.50 mts. above grade. 1.00 mtr.
445 Minimum vertical clearance from the bottom of a signage to an arcaded sidewalk. 5.00 mts.
446 Minimum vertical clearance from the bottom of a signage to non-arcaded sidewalk. 3.00 mts.
447 Number of days of work abandonment of stoppage for a building permit to expire. 120 days
448 Width of planting strip for sidewalks 2.00 mts in width. 0.80 mtr.
449 Minimum horizontal distance of the curb line to the outermost face of an arcade. 500 mm
452 Slope of driveway to sidewalk where the height of curb is 200 mm and above. One is to Eight (1:8)
Minimum vertical clearance of primary lines from the crown of the pavement when
453 10.00 mts.
crossing the highway.
Minimum vertical clearance of primary lines from top of sidewalk when installed along
454 7.5 mts.
the side of the highway.
455 Vertical clearance of secondary lines from sidewalks along or crossing the street. 7.5 mts.
456 Minimum clearance of conductors from the highest point of a roof. 2.50 mts.
Minimum clearance of conductors from any platform or ground or projection from which
459 3.00 mts.
they might be reached.
Minimum vertical clearance of service drop of communication lines above ground at its
460 3.00 mts.
point of attachment to than building or pedestal.
24/54
PREPARED BY:
ALEXANDER SAN ANDRES
461 Vertical clearance of a service drop communication line when crossing a street. 5.50 mts.
466 Unit area per occupant for offices and garages. 9.30 sqm.
467 Unit area per occupant for class rooms. 1.80 sqm.
468 Unit area per occupant for stores - retail sales rooms upper floors. 5.60 sqm.
469 Unit area per occupant for nurseries for children. 3.25 sqm.
470 Unit area for stores -retail sales room for basement and ground floor. 2.80 sqm.
472 Unit area per occupant for aircraft hangars without repairs. 46.50 sqm.
473 Unit area per occupant for warehouses and mechanical equipment room. 28.00 sqm.
474 Unit area per occupant for theaters and the like. 0.65 sqm.
Parking requirement for public assembly buildings such as cinemas, auditoria, theaters, 1 slot/50 sqm. Of
476
and the like. spectators' area
477 Parking requirement for multi family living unit of 50 sqm floor area. 1slot/8 units
478 Parking requirement for multi family living unit above 100 sqm floor area. 1 slot/unit
479 Parking requirement for multi family living unit for 50-100 sqm floor area. 1 slot/4 units
1 slot/100 sqm of
480 Parking requirement for clubhouses, beach houses, and the like.
gross flr.area
1 slot/50 parking
482 Minimum parking requirement for the handicapped.
slots
25/54
PREPARED BY:
ALEXANDER SAN ANDRES
484 Parking requirement for elementary, secondary, and vocational schools. 1 slot/10 classrooms
490 Maximum distance of handicapped parking from the structure served. 60.00 mts.
492 Maximum height of a water closet from the floor. 0.50 mts.
496 Least dimension for a parking slot for the disabled. 3.70 mts.
One or more habitable rooms which are occupied or which are intended or designated
500 Dwelling unit
to be occupied by one family with facilities for cooking , sleeping, living, and eating.
That portion of the foundation of a structure which spreads and transmits loads directly
501 Footing
to the ground or soil.
A room or suite of two or more rooms, designed and intended for , or occupied by one
503 Apartment
family for living, sleeping, eating, and cooking purposes.
A stationary open hearth or brazier, either fuel-fired or electric, used for food
504 Barbecue
preparation.
26/54
PREPARED BY:
ALEXANDER SAN ANDRES
A portion of the seating space of an assembly room, the lowest part of which is raised
505 Balcony
1.20 mts or more above the level of the main floor.
506 The pipe which connects a flue-burning appliance to a chimney. Chimney connector
A hearth and fire chamber or similarly prepared place in which a fire may be made and
507 Fireplace
which is built in conjunction with a chimney.
A horizontal structural piece which supports the end of the floor beams or joists or walls
508 Girder
over opening.
512 A term which may be used synonymously with a partition. Cross wall
513 The unit area per occupant for hotels. 18.60 sqm.
514 The unit area per occupant for dining establishments. 1.40 sqm.
515 The unit area per occupant for theaters. 0.65 sqm.
A building permit shall expire if work authorized is abandoned or suspended at any time
516 120 days / 4 mos.
after commencement for a period of.
Front yards for commercial buildings abutting a road-right-of-way of 25-29 meters shall
517 8.00 mts.
have a minimum width of
518 Offices shall be provided how many cubic meters of air per person? 12.00 cum.
Multiple living units of up to 6 units built on the same lot shall have an access road
519 3.00 mts.
directly connecting said building to a public street a width of.
Sidewalks of 2 mts or more in width shall include on its outer side a planting strip of not
520 800 mm / 0.80 mtr.
less than how many millimeters in width?
Arcades shall be cantilevered from the building line over the sidewalk and the horizontal
521 clearance between the curb line and the outermost face of any part of the arcade shall 500 mm
not be less than.
Business and
522 Printing plants shall be classified under what type of occupancy.
mercantile
523 Power plants shall be classified under what type of occupancy. Industrial
Residentials, hotels
524 Convents shall be classified under what type of occupancy.
and apartments.
Storage and
525 Repair garages shall be classified under what type of occupancy.
hazardous
27/54
PREPARED BY:
ALEXANDER SAN ANDRES
527 Turnabout should also be provided at or whithin how many meters of dead end. 3.50 mts.
529 Under B.P. 344, a level area of not less than how many meters shall be provided at the
1.80 mts.
530 top and bottom of any ramp.
531 Under what classification of occupancy does Mental Hospitals fall? Institutional
Residentials, hotels
532 Under what classification of occupancy does Monasteries fall?
and apartments.
Business and
533 Under what classification of occupancy does Aircraft hagars fall?
mercantile
534 Under what classification of occupancy does cold storage and creameris fall? Industrial
535 Under what classification of occupancy does private garage fall? Accessory
536 Minimum loading slot requirement for Hospitals and hotels. 1 truck loading slot
537 Minimum travel distance from handicapped parking to facility being served. 60 mts.
Percentage required for number of parking if parking garages are available within 200
538 20%
meters of structure.
1/150 sqm of
540 Parking requirement for markets.
shopping flr area
1/100 sqm of
541 Parking requirement for neigborhood shopping centers.
shopping flr area
Parking requirement for multi-family living units of more than 100 sqm of living unit
542 1/living unit
area.
543 Parking requirement for multi-family living units of up to 50 sqm of living unit area. 1/8 living units
1/50 sqm of
544 Parking requirement for places of worhip.
congregation are
Maximum projection of a balcony over a street of over 3 meters but not more than 6
545 0.60 mtr.
mts.
546 Maximum projection of a balcony over a street of 10 mts to less than 11 mts in width. 1.00 mtr.
547 Maximum height of 1st the floor for a 2-story wood structure with a height of 7 mts. 4.50 mts.
548 Maximum spacing of posts for 2-story wooden structure with a height of 8 mts. 4.50 mts.
28/54
PREPARED BY:
ALEXANDER SAN ANDRES
549 Under what classification of occupancy does fences of over 1.80 mts in height fall? Accessory
Storage and
550 Under what classification of occupancy does Aircraft repair hangars fall?
hazardous
Storage and
552 Under what classification of occupancy does wood working establishements fall?
hazardous
Business and
553 Under what classification of occupancy does police and fire stations fall?
mercantile
How many meters above the floor is the comfortable reach of persons confined to a
556 0.70 - 1.20 mts.
wheelchair.
How many meterd is the comfortable clearance for knee and leg space under tables for
557 0.74 mts.
wheelchair users.
Accessibility, reachability, usability, orientation, workability and efficiency, and ___ are
558 Safety
the basic planning requirements of BP344.
562 A raised rim of concrete, stone or metal which forms the edge of street, sidewalk, etc. Curb
The purpose of the NBC is to provide for all buildings and structures, a framework of
563 standards and requirements which is the minimum
564 Under the NBC abutment on lot lines are allowed only in . Fire zones
Under the NBC, every corridor and exterior exit balcony servings as a required exit for
565 an occupant load of more than ten width shall not be less than 1.20 mts
566 Under the NBC, the vertical distance between landings shall not be more than 3.60 mts
567 Under the NBC, open spaces for corners and through lots is a. 10%
569 Under the NBC, space required for interior lots is 50%
Under the NBC, the minimum dimension for court or near yard from the property line
570 to the face of the building is 2.00 mts
29/54
PREPARED BY:
ALEXANDER SAN ANDRES
Under the NBC, clearance between established grade of the street and/ or sidewalk
572 and the lowest under surface of any part of the balcony shall not less than 3.00 mts
573 Under the NBC, the interior lots shall have an access road with a minimum width of 3.00 mts
Under the NBC, gasoline filling and service stations shall classified under what
business &
574 occupancy classification?
mercantile
Under the NBC, display windows or wall signs within how many meters above the
575 sidewalk 3.00 mts
Under the NBC, areas where adequate parking lots/ multi-floor parking garages are
available within 200 mts. of the proposed building / structures only what percent of
576 20%
the parking requirements maybe provided within the premises?
Under the NBC, general units of measurement on consonance with the current
577 worldwide practice follow the System International
578 Under the NBC, the minimum requirements for a parking space is 750 mm
579 Under the NBC, for Group A Dwellings, stairs shall have a clear width of at least 2.50x5.00
Under the NBC, mezzanine floors shall have a clear ceiling height not less than how
580 many? 1.80 mts
581 Under the NBC, hospitals shall have one parking slot for every how many beds? 25
Under the NBC, all inner courts shall be connected to a street or yard either by a pass
582 with a minimum width of 2.00 mts
Under the NBC, a dwelling shall occupy not more than how many percent of an
583 inside non-corner single frontage lot? 80%
584 Under the NBC, prisons shall be classified under what occupancy classification institutional
585 Under the NBC, cold storage shall be classified under what occupancy classification? storage& mercantile
Under the NBC, factories using not highly combustible materials shall be classified
586 under occupancy classification? industrial
Under the NBC, window openings shall equal to at least of what percent of the floor
587 area of room? 10%
Under the NBC, parking areas for the physically handicapped shall be within how
588 many meters in length? 6.00 mts.
Under the NBC, of only two exits are required, they shall be placed a distance apart
589 of not less than what fraction of? 1/5.
Under the NBC, habitable rooms with natural ventilation shall have a minimum air
590 space per person of 14 cu. mts.
591 Under the NBC, the unit area per occupant of offices is 9.3 m2
30/54
PREPARED BY:
ALEXANDER SAN ANDRES
Under the NBC, residential hotels and apartels shall be provided with one parking slot
593 for every how many units? 5 units
594 Under the NBC, for Group A Dwellings, stairs shall have 750 mm
595 Under the NBC, rooms for human habitation shall have a minimum size of 6 m2
business &
596 Under the NBC, reformatories shall be classified under what occupancy classification
mercantile
Under the NBC, repair garages shall be classified under what occupancy
597 classification? storage & hazardous
residential, hotels
598 Under the NBC, convents shall be classified under what occupancy classification?
and apartments
599 Under the NBC, power plants shall be classified under what occupancy classification? storage & hazardous
Under the NBC, printing plants shall be classified under what occupancy
600 classification?
Under the NBC, multiple living units of up to six units built on the same lot shall have an
601 3.00 mts.
access road directly connecting said building to a public street a width of
602 Under the NBC, offices shall provide how many cubic meters of air space per person? 12 cu. mts.
Under the NBC, front yards for commercial buildings abutting a road right-of-width
603 of 25-29 m shall be 8 mts.
Under the NBC, a building permit shall expire if work authorized is abandoned or
604 suspended at any time after commencement or a period of 120 days
605 Under the NBC, the unit area per occupants of theaters is 65 m2
606 Under the NBC, the unit area per occupant of dining establishments is 1.4 m2
607 Under the NBC, the unit area per occupant of hotels is 18.6 m2
Under the NBC, the fire station shall be classified under what occupancy
business &
608 classification?
mercantile
Under the NBC, in mixed occupancies the parking requirements shall be the sum of
611 100% of the dominant use and what percent of the dominant uses? 50%
Under the NBC, habitable rooms provided with artificial ventilation for buildings of
612 more than one-storey shall have a minimum ceiling height of the first storey at 2.40 mts.
Under the NBC, multiple living units of 16 to 25 units built on the same lot shall have
613 an access road directly connecting said buildings to a public street a width of 3.00 mts.
31/54
PREPARED BY:
ALEXANDER SAN ANDRES
Under the NBC, every room intended for any use and not provided with artificial
ventilation system shall be provided with a window with a total free area of opening
615 10%
equal to at least how many percent of the floor area of the room?
616 Under the NBC, for Group A Dwellings, stairs shall have a minimum run of 200 mm.
617 Under the NBC, the unit area per occupant of laboratories is 4.6 m2
618 Under the NBC, the unit area per occupant of apartment is 28 sm.
Under the NBC, the term that shall mean the total number of persons that may occupy a
619 building or a portion thereof at any one time is occupant load
620 Accessible parking should have a minimum width of _________ 3.70 mts.
Perpendicular and diagonal parking for average auto mobile should have a minimum
621 2.50m x 5.00m
_________
622 Parallel parking for average auto mobile should have a minimum __________ 2.15m x 6.00m
623 Jeepney / shuttle parking slot should have a minimum __________ 3.00m x 9.00m
624 Standard truck / bus parking slot must have a minimum __________ 3.60m x 12.00m
625 An articulated truck slot must be computed at a minimum of __________ 3.60m x 18.00m
628 What is the minimum requirement for Total Open Spaces for Through Lot? 10% open space
629 What is the minimum requirement for Total Open Spaces for Corner Lot? 10% open space
Mezzanine floor shall have a clear ceiling height not less than ________ above and
630 1.80m
below it.
632 What is the least dimension for Room (Human Habitations)? 2.00m
633 What is the minimum requirement for Total Open Spaces for Inside Lot? 20% open space
634 What is the minimum requirement for Total Open Spaces for End Lot? 50% open space
32/54
PREPARED BY:
ALEXANDER SAN ANDRES
Habitable rooms provided with artificial ventilation shall have ceiling height not less than
636 2.40m
__________ measured from the floor to ceiling.
637 What is the minimum dimension for Accessible Elevator? 1.10m x 1.40m
Accessible elevator should be located not more than __________ from the entrance and
638 30 m.
should be easy to locate with the aid of signs.
639 Accessible water closet stalls shall have a minimum dimension of __________. 1.70m x 1.80m
640 Passenger train shall have at least __________ designated seats for disabled person. 6
A bar which extends across at least ½ the width of each door leaf, which will open the
642 Panic hardware
door if subjected to pressure.
Who shall be the responsible for carrying out the provision of the Building Code as well
645 Building Officials
as the enforcement of orders?
646 A court bounded on all sides or around its periphery by building lines. Inner court
The physical development within a lot or property that is under-utilized, unfit / unsafe for
647 Redevelopment
habitation / use or within other lots / properties that are similarly situated.
The fully enclosed component of the building / structure situated between the
648 establishment grade and the first of a typical floor of the building / structure’s tower Podium
component.
A portion of a yard for which the permitted limit of paving / hardscaping shall not exceed
652 Courtyard
50% of the area of the yard.
The angle of inclination of an escalator shall not exceed __________ form the
655 30 degree
horizontal.
33/54
PREPARED BY:
ALEXANDER SAN ANDRES
The rate and speed, measured along the angle of inclination, shall be not more than
656 38 m./min.
__________ meters per minute.
Hoistway pit for elevators shall be of such depth that when the car rest on the fully
658 compressed buffers, a clearance of not less than __________ remains between the 600 mm.
underside of the car and the bottom of the pit.
659 How many storey shall a dry stand pipe be equipped with it? 4 Storey
. What is the maximum total projection of balcony if the width of the streets are over
660 1.50m
14.00 meters
662 What is the minimum road right-of-way width to be able to construct a basement? 10.00m
What is the minimum width of planting strip (for glass and shrubs) for each side of the
664 200mm
RROW?
Sidewalks of 2.00 meters or more width shall include on its outer side a planting strip of
665 800mm
not less than _________ in width.
667 Escalators width shall not exceed the width of the steps by more than __________ 330 mm
Firewall with a minimum 2 hour fire-resistive rating constructed with a minimum height
669 400mm
clearance of __________ above the roof.
670 What is the minimum setback for residential-1? 4.50 x 2.00 x 2.00
What is the minimum setback for Commercial buildings if the RROW is 30.00m and
671 8.00 x 5.00 x 5.00m
above?
672 What is the minimum width of planting strip (for trees) for each side of the RROW? 300mm
673 What is the minimum Total Open Space for Corner-through lot? . 5% open space
674 What is the minimum Total Open Space for Interior Lot? 50% open space
675 Roof – The wind load for roof shall be atleast __________ kg/m2 for vertical projection. 120
Footing shall be of sufficient size and strength to support the load of the dwelling and
676 250mm & 600mm
shall be at least __________ thick and __________ below the surface of the ground.
34/54
PREPARED BY:
ALEXANDER SAN ANDRES
What is the required distance of ingress / egress of vehicles for commercial lot near
677 50.00m
major intersections?
A building permit issued under the provision of the Building Code shall expire and
679 become null and void if the building or work authorized therein is not commenced within 12 months
a period of _________
681 What is the Air Space requirement for a Habitable Rooms? 14.00m3
Any portion of building above the first floor projecting over the sidewalk beyond the first-
682 Arcade
storey wall used as protection for pedestrians against rain or sun.
That portion of the foundation of a structure which spreads and transmits loads directly
683 Footing
to the soil or the pile.
All the portions of the building or structure below the footing, the earth upon which the
684 Foundation
structure rests.
A horizontal structural piece which supports the end of the floor beams or joist or walls
685 Girder
over opening.
687 A corridor or passageway used in common by all the occupants within a building. Common Hall
The beam or girder placed over an opening in a wall, which supports the wall
688 Lintel
construction above.
A Lodging House is any building or portion thereof, containing not more than
689 5
__________ guest rooms where rent is paid in money, goods, labor, or otherwise.
690 The wall between the bottom of the window sill and the ground. Masonry Socalo
692 . A wall which supports any load other than its own weight. Bearing Wall
What is the Wheelchair Seating Capacity for an Auditoriums that has 51 -300 seating
694 4
capacity?
35/54
PREPARED BY:
ALEXANDER SAN ANDRES
698 All doors should have a minimum clear width of __________ 0.80 m.
Dropped curbs shall be sloped toward the road with a maximum gradient of
701 1:20
__________ to prevent water from collecting at the walkway.
703 Curb cut-outs should not have a gradient not more than __________ 1:12
704 What is the minimum dimension for Rest Stops on busy or lengthy walkways? 12.00m
Ramps shall be equipped with curbs on both side with a minimum height of
706 0.10 m
__________
The railing should incorporate a tapping rail to assist the blind; this should not be
707 0.35 m
greater than __________ above the adjacent surface.
Blighted Area; Eyesore; An area where the value of real estate tend to deteriorate
708 because of the dilapidated, obsolescent, and insanitary condition of the building within Slum
the area.
Entrance with vestibules shall be provided a level area with at least a __________ depth
710 1.80m
and a 1.50m width.
The length of ramp should not exceed __________ if the gradient is 1:12, and shall
711 6.00m
provided with landing not less than 1.50m
712 What is the incremental setback per storey above the second floor level? 0.30m
713 Arcade pedestrian walkways shall have a clear height of __________ 3.00m
All pipe materials to be used in buildings/ structures shall conform to the standard Bureau of Product
714
specification of the __________ of the Department of Trade and Industry. Standards
715 The live load at first floor shall be at least __________ kg/m2 200 kg/m2
716 The live load for the second floor shall be at least __________ kg/m2 150 kg/m2
Multi-floor parking garages may serve the 20% parking requirements of the building /
717 200
structure within __________ meter radius.
36/54
PREPARED BY:
ALEXANDER SAN ANDRES
What is the minimum required parking slot for offices, commercial or mixed-use
718 1 car : 2 units
condominium buildings / structures if the unit gross area is 18 – 40 m2?
In BP 344, Handrails that required full grip should have a minimum dimension of
719 30 cm.
__________cm – 50 cm
In BP 344, The lowest point of a dropped curb should not exceed _________ height
720 25 mm.
above the road or gutter.
721 Which does the building code regulate and control? Construction
formulate guidelines
Which is not part of the general powers and functions of the secretary of the Public
722 on land-use planning
Works, Transportation and Communication pertinent to the National Building Code?
and zoning
723 Who is responsible in carrying out the provisions of the National Building Code? Building Officials
What are the two cases which invalidates the building permit. I - when construction does
not commence with in one year from the date of its issue; II - when construction is
724 I & IV
suspended for more than one year; III - when construction is suspended for six months;
IV - when construction is suspended or abandoned for a period of 120 days :::
Which is a reason or ground for non-issuance, suspension or revocation of a building errors found in plans
725
permit? and specifications
certificate of
726 What document is necessary in order to legally occupy a building?
occupancy
727 Where is the measurement of site occupancy taken? gross floor area
728 Which is not a determinant in the limitation of maximum site occupancy? Use
729 What is the minimum height of ceilings for spaces that are naturally ventilated 2.7 m.
What is the minimum head room clearance for the third floor that is artificially
730 2.10 m.
ventilated?
731 The minimum window area for a 12 square meter naturally ventilated room. 1.2 m2
733 In order to positively drain a sidewalk, its slope shall be about ___. 1:50
Any new construction which increases the height or area of an existing building or
735 Addition
structure.
37/54
PREPARED BY:
ALEXANDER SAN ANDRES
737 Construction of partitions and roofing on the roof deck in order to make it habitable. Addition
739 What is the minimum access road that is provided by the National building code? 3 m.
Which office issue certificate of height clearance for buildings located within approach
740 Air Trans. Office
and departure zones of airports?
741 Which is not required in applying for a building permit? Bussiness Permit
742 Which is the most important basic need of human settlement? Water
743 What is the minimum slope for accessible ramps for disabled? 1:12
Is a set of rules that specify the minimum acceptable level of safety for constructed
744 objects such as buildings and Building Codes
nonbuilding structures.
Under PD 1096 the executive officer of OBO appointed by the sectary to enforce the
745 provision of the code in the field Building official
as well as the enforcement or orders and decisions made pursuant thereto.
This wall is sometimes constructed over the center of the property line dividing two
terraced flats or row houses so
746 Party Walls
that one half of the wall is on each property. They are sometimes two abutting walls
built at different times.
Usually gives us architect problems, we have to verify with the barangay or homeowner
association for preliminary
747 Local Ordinances
approval to avoid conflict with our design and to avoid delay in our application of
permits.
Minimum Gauge of galvanized sheet used for
748 GA 26
downspouts.
751 Required number of water closets for females for an auditorium serving 16-35. 3
38/54
PREPARED BY:
ALEXANDER SAN ANDRES
770 BP 220: The parking requirement for multi-family dwelling is 1 slot/family dwelling
39/54
PREPARED BY:
ALEXANDER SAN ANDRES
775 Maximum stair rise height for a class A stair. 0.19 mtr.
776 Maximum height between landings for class A stair. 2.75 mts.
778 Unit area per person for waiting areas or standing rooms. 0.28 sqm.
780 Travel distance to an exit without fire sprinkler system. 46.00 mts.
781 Travel distance to an exit with fire sprinkler system. 61.00 mts.
782 Minimum spacing of rows of seats from back to back for a public assembly building. 0.83 mtr.
785 Standard width of a seat without dividing arms for places of assembly. 60 cms.
787 Minimum headroom created by any projection from the ceiling. 2.00 mts.
789 Minimum dimension of landings in direction of travel for class A & B stairs. 112 cms.
791 Minimum height of a handrail above the upper surface of the tread. 76 cms.
798 Maximum rise of any floor from the balcony floor to which an access door leads. 20.3 cms
40/54
PREPARED BY:
ALEXANDER SAN ANDRES
800 Minimum width of a fire escape stair for existing stairs. 55.9 cms.
801 Minimum width of landing for a fire escape stair for existing stairs. 55.9 cms.
802 Minimum tread for a fire escape stair for small buildings. 15.25 cms.
803 Maximum rise of fire escape stair for a small building. 30.5 cms.
804 Maximum rise of fire escape stair for existing stairs. 22.9 cms.
805 Maximum height between landings for a fire escape stair for existing stairs. 3.66 mts.
806 Minimum headroom clearance for a fire escape stair for existing stairs. 2.13 mts.
807 Minimum headroom clearance for a fire escape stair for small buildings. 1.98 mts.
Maximum travel distance between room door intended as exit access and exit with sprinkler
811 30 mts.
system for institutional use.
812 Maximum travel distance from the door of any room to exit for hotels with sprinkler. 30 mts.
813 Maximum travel distance from the main entrance door to exit for apartments with sprinkler. 31 mts.
814 Minimum increase in width for an aisle per linear meter. 2.5 cms.
Minimum width of an aisle serving an occupant of 60 or more serving one side for a public
815 91 cms.
assembly building.
Minimum width of an aisle serving an occupant of 60 or more serving two sides for a public
816 1.00 mtr.
assembly building.
817 Minimum width of an aisle serving an occupant of below 60 for a public assembly building. 76 cms.
818 Minimum width of an aisle for an educational use building. 1.80 mts.
819 Minimum width of an aisle for hospitals or nursing homes. 2.44 mts.
820 Minimum width of an aisle for custodial care institutions. 1.83 mts.
821 Minimum width of an aisle for business use structure. 112 cms.
41/54
PREPARED BY:
ALEXANDER SAN ANDRES
Courtrooms with an occupant load of more than 100 are classified under what classification of
825 Assembly
occupancy.
Armories with an occupant load of more than 100 are classified under what classification of
826 Assembly
occupancy
828 Rooms where baled, bundled or piled materials segregated into desired sizes or groups. Picking rooms.
830 Buildings or structures used for the storage of explosives, shells, projectile, etc. Explosive magazine
An air compartment or chamber to which 1 or more ducts are connected and which form part of
831 Plenum
an air distribution system.
833 Descriptive of any substance that ignites spontaneously when exposed to air. Phyrophoric
834 A material that readily yields oxygen in quantities sufficient to stimulate or support combustion. Oxidizing material
835 A process where a piece of metal is heated prior to changing its shape and dimension. Forging
The process of first raising the temperature to separate the more volatile from the less volatile
836 parts and then cooling and condensing the result vapor so as to produce a nearly purified Distillation
substance.
A finely powdered substance which, when mixed with air in the proper proportion and ignited will
837 Dust
cause an explosion.
840 The temperature at which a liquid is transformed or converted into vapor. Boiling Point
The minimum temperature at which any material gives off vapor in sufficient concentration to form
843 Flash Point
an ignitable mixture with air.
A gas, fume or vapor used for the destruction or control of insects, fungi, vermin, germs, rodents
844 Fumigant
or other pests.
845 Minimum width of any driveway in and around a lumber yard / piles. 4.50 mts.
846 Minimum height of fence for a lumber yard for exterior storage of lumbers. 1.80 mts.
847 Maximum width of sumps for the retention of oil and petroleum products. 3.70 mts.
848 For Refineries, distilleries, and chemical plants, the minimum height for a fence. 1.50 mts.
849 Minimum travel distance from any individual room subject to occupancy by not more 6 persons. 15.00 mts.
42/54
PREPARED BY:
ALEXANDER SAN ANDRES
850 Maximum distance of travel from the high hazard area to an exit. 23.00 mts.
851 Minimum distance of an incinerator from any structure used other than a single family dwelling. 3.00 mts.
Maximum change in elevation between the interior of a door to the outside of it other than a
854 20.5 cms.
balcony.
856 Maximum height required for a panic hardware installation. 112 cms.
858 Maximum number of occupant for a subdivided room or space by a folding partition. 20
859 Minimum width of a door for family day care homes. 61 cms.
860 Minimum stair width for a class B stair serving an occupant load of less than 50. 91 cms.
Length of a nosing or effective projection over the level immediately below it for tread below 25
861 25 mm
cms in dimension.
863 A combustible liquid is any liquid having a flash point at or above. 37.8 oC (100 oF)
The time duration that a material or construction can withstand the effect of standard fire test is
864 Fire resistance rating
known as.
Any material which by its nature or as a result of its reaction with other elements produces a rapid
865 Cryogenic
drop in temperature of the immediate surrounding.
866 Classified as mercantile occupancies, the travel distance from exits shall be. 30.50 mts.
867 Under what classification of occupancy does pool rooms fall. Assembly
868 Under what classification of occupancy does home for the aged fall. Institutional
869 Under what classification of occupancy does court houses fall. Business
874 Minimum clear width of aisles for a Class 'A' store. 1.50 mts.
43/54
PREPARED BY:
ALEXANDER SAN ANDRES
875 Minimum clear width of an exit access through a covered mall. 3.66 mts.
877 Standard inner radius of a curved stair in business occupancies. 763 cms.
880 Minimum width of stair for Class 'B' stairs serving more than 50 persons. 112 cms.
881 Minimum width of stair for Class 'B' stairs serving 50 persons and below. 91 cms.
883 Minimum width of a stair width for Class 'A' stairs. 25 mm.
884 Maximum height between landings for a Class 'B' stairs. 3.70 mts.
885 Minimum width of landings in direction of travel for Class 'A / B' stairs. 112 cms.
889 Maximum height between landings for Class 'A' ramp. No limit
890 Maximum height between landings for Class 'B' ramp. 3.66 mts.
892 Minimum width for fire escape for existing stairs. 55.9 cms.
893 Minimum horizontal dimension of any landing of platform for existing stairs for fire escape. 55.9 cms.
894 Maximum rise for a fire escape for very small buildings. 30.5 cms.
895 Maximum height between landings for fire escape for existing stairs. 3.66 mts.
896 Minimum distance travel to an exit for storage occupancies of high hazard commodities. 23 mts.
Class of fire involving combustible metals, such as magnesium, sodium, potassium, and other
897 Class D
similar materials.
Class of fire involving ordinary combustible materials, such as wood, papers, cloth, rubber, and
898 Class A
plastics.
A tank, vat or container of flammable or combustible liquid in which articles or materials are
899 Dip Tank
immersed for the purpose of coating, finishing, treating or similar processes.
44/54
PREPARED BY:
ALEXANDER SAN ANDRES
901 A continuous and unobstructed route of exit from any point in a building to a public way. Means of Egress
902 Minimum distance of an incinerator containing kindled fire or rubbish fire or bonfires. 5.00 mts.
904 Under what classification of occupancy does town halls fall? Business
906 Minimum tread for a fire escape stair for existing stairs. 22.9 cms.
907 Maximum spacing of rungs for a fire escape ladder. 30.5 cms.
Class III combustible liquids shall mean any liquid having a flash point at how many degrees
909 60 oC
Celsius?
910 In standard seating, the minimum spacing from back to back. 0.83 mtr.
911 Minimum space from the back of chair to the front of the chair behind. 30 cms.
912 Maximum slope for aisles for public assembly structures. (1:8) 12.5%
913 Size of standpipe provided for each stage for public assembly building. 63.5 mm.
Where exterior corridors or balconies are provided as means of exit, they shall open to the outside
915 76.25 mts.
and shall be spaced ___ meters apart. (Educational)
917 Maximum height from the floor for a rescue window for educational occupancies. 82 cms.
918 Minimum width of corridors, aisles, and ramps for exits in hospitals and nursing homes. 2.44 mts.
919 Minimum width of corridors, aisles, and ramps for exits in residential-custodial care. 1.83 mts.
Any room for sleeping in institutional occupancies if subdivided shall have a maximum area of how
920 465 sqm.
many square meters?
Includes buildings or groups of building under the same management in which there are more than
921 Hotel
15 sleeping accommodations for hire.
Includes buildings containing three or more living units independent cooking and bathroom
922 facilities, whether or by any other name.designed as rowhouse, apartment house, tenement, Apartment Buildings
garden apartment,
923 Minimum number of stories of apartment buildings requiring fire alarm system. 3
45/54
PREPARED BY:
ALEXANDER SAN ANDRES
925 An Act to Ordain and Institute the Civil Code of the Philippines RA 0386
926 An Act to Regulate the Practice of Civil Engineering in the Phils. RA 0544
46/54
PREPARED BY:
ALEXANDER SAN ANDRES
CELLULOSE
953 explosive compound produced by the reaction of nitric acid w/ cellulose material
NITRATE
COMBUSTIBLE
955 flash point above 37.8 C or 100 F
LIQUID
956 liquid causes fire when contact with organic matter CORROSIVE LIQUID
958 in air duct system; device to restrict the passage of smoke or fire DAMPER
959 first raising the temperature to separate the more volatile from the less DISTILLATION
963 minimum temperature at which materials give off vapor to form ignitable mixture with air FLASH POINT
964 a piece of metal is heated prior to changing its shapes or dimensions FORGING
966 a rocket or liquid propellant when fuels and oxiders combined HYPERGOLIC FUEL
OXIDIZING
967 materials that readily yields oxygen in quantities sufficient to support combustion
MATERIAL
968 descriptive of any substance that ignites spontaneously when exposed to air PYROPHORIC
969 impurities or deleterious material remove from a mixture to produce pure element REFINING
970 melting or fusing of metallic ores to separate impurities from pure metals SMELTING
47/54
PREPARED BY:
ALEXANDER SAN ANDRES
983 difference between developed and undeveloped area on circulation TYPE OF PAVEMENT
998 floor area requirement for single family dwelling unit 20 sqm
48/54
PREPARED BY:
ALEXANDER SAN ANDRES
1003 minimum door clear height for mezzanine and bathroom 1.80 m
49/54
PREPARED BY:
ALEXANDER SAN ANDRES
1024 minimum distance of roof eaves between two dwelling units 1.5
1025 minimum distance between two dwelling units (3-4 storeys) 6.00 m
1026 minimum roof eaves distance of two dwelling units (3-4 storeys) 2.00 m
1027 minimum distance between two dwelling units (more than 4 storeys) 10.00 m
1028 minimum horizontal distance of two dwelling units (more than 4 storeys) 6.00 m
1029 minimum roof eaves distance of two dwelling units (more than 4 storeys) 1.00 m
1031 minimum floor area for multi family dwellin units 36.00 sqm
1038 maximum allowable slope ramps with 300mm changes in elevation 15%
1045 for 4 or more building storey in height w/ roof slope not greater than 1:3 one stairwell
1048 a public way intended to serve for pedestrians and emergency vehicles ALLEY
50/54
PREPARED BY:
ALEXANDER SAN ANDRES
1049 a parcel of land bounded on the sides by the streets or alleys o pathways BLOCK
1050 a single family attached dwelling containing 3 or more separate living units CLUSTER HOUSING
1051 a wall w/c seperates two abutting living units as to resist the spread of fire FIREBLOCK
1052 a fireblock which extends vertically from the lowest portion of the wall FIREWALL
1053 a wall jointly used by two parties under easements agreement PARTYWALL
50 sqm/10 units 3
1069 parks and playground
sqm/additional unit
1073 required area of playgrounds/parks for every 1,000 sqm 100 sqm
51/54
PREPARED BY:
ALEXANDER SAN ANDRES
1074 features that enable the disable person to make use of the primary function ACCESSIBLE
1077 the degree of inclination of the sloped surface expressed in ratio GRADIENT OF RAMP
1078 a sloped surface connecting two or more surface at different levels RAMP
a strip fastened to the floor usually required to cover the joint where two types of floor
1080 THRESHOLD
materials meet
1092 centerline height of topmost buttons of elevator and floor switches .90 m - 1.20 m
1096 level area at the top and bottom of any ramp 1.80 m
52/54
PREPARED BY:
ALEXANDER SAN ANDRES
1103 height of the rim of the fountain from the floor 0.85 m
a written authorizaton granted by the building official to an applican allowing him to him
1114 BUILDING PERMIT
proceed with the construction
all on site work done from site preparation, excavation, foundation, installation in place
1115 CONSTRUCTION
of components of a building or structure
1116 any new construction which increases the height or the area of an existing bulding ADDITON
53/54
PREPARED BY:
ALEXANDER SAN ANDRES
a secondary building located within the same premises the use of which is incidental to ANCILLARY
1124
that of the main building BUILDING