Download as pdf or txt
Download as pdf or txt
You are on page 1of 47

Directional Control Valves

Photo Type Series Description Main Specifications

Solenoid
SS Solenoid Valve 26.4 - 42.3gpm, 5000psi
Valves

Solenoid Solenoid Valve (DIN


SA 26.4 - 42.3gpm, 5000psi
Valves Connector Type)

Solenoid Valve (Low


Solenoid 7.9 - 26.4gpm
SE Current & Low Power
Valves 1428 - 3000psi
Consumption Type)

Solenoid DSS Solenoid Controlled


158.5gpm, 4571psi
Valves (DSA) Pilot Operated Valve

Fine
Fine Solenoid Valve
Solenoid SF 2.6 - 10.6gpm, 3000psi
(High-Low Valve)
Valves

Solenoid Solenoid Valve with


SAW 42.2gpm, 5076psi
Valves Monitoring Switch

Manual Manually Operated


DMA 10.6 - 19.8gpm, 3571psi
Valves Directional Valve
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 1

WET TYPE SOLENOID OPERATED


DIRECTIONAL CONTROL VALVE
SS Series(Wiring System: Central Terminal Box) 26.4 to 42.3gpm
Wet Type Solenoid Valve 5000psi

Features
qVery long life sation and low pressure compensation con- replacement.
The movable iron core of the wet type sole- struction provide large capacity and low yWide-ranging backward compatibility makes
noid is immersed in oil, which keeps it lubri- pressure loss. it simple to replace previous valve models
cated and cushions it from impact and vibra- G01 : 35MPa{357kgf/cm2}100r/min with this one. Combining this valve with a
tion, ensuring very long life. G03 : 35MPa{357kgf/cm2}160r/min modular valve contributes to the compact
wLow switching noise rEasy connections configuration of the overall device.
The wet-type solenoid valve provides very A special wiring box provides a COM port uGlobal support (G01 size)
low core switching noise, for quiet operation. and indicator light as standard for simple Meets overseas safety standards (CE, UL,
eHigh pressure, large capacity, with minimal wiring and maintenance. and CSA). It can be safely used anywhere in
pressure loss tEasy coil replacement the world. Contact your agent for certified
Comprehensive fluid reaction force compen- A plug-in type coil enables one-touch coil products.

Specifications
SS-G01 SS-G03
Standard Type
Model No.
Standard Type Shockless Type DC Solenoid Type Shockless Type
AC Solenoid Type
(With built-in rectifier)
Operation Maximum Maximum Working Maximum Maximum Working Maximum Maximum Working Maximum Maximum Working Maximum Maximum Working
JIS Symbol Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure
Symbol r/min MPa{kgf/cm2} r/min MPa{kgf/cm2} r/min MPa{kgf/cm2} r/min MPa{kgf/cm2} r/min MPa{kgf/cm2}

-A2X- (gpm) (psi) (gpm) (psi) (gpm) (psi) (gpm) (psi) (gpm) (psi)
40
-H2X- 30 30 (10.6) 85 85
(7.9) (7.9) 85 (22.4) (22.4)
-E2X-
(22.4)
-A3X-
80
(21.1)
-H3X-
100
-E3X-
(26.4)
-A3Z-
65
-H3Z-
(17.1)
-E3Z-

-A4-
50
(13.2) 35{357} 35{357}
-H4-
(5000) (5000)
35 25{255} 25{255}
-A5-
(5000) 50 (3571) 130 160 130 (35.71)
(13.2) (34.3) (42.2) (34.3)
-H5-

-C2-
100
-C5-
(26.4)
-C9-

-C1S-

-C6S-

-C1- AC Solenoid
65 (17.1)
DC Solenoid
-C6- 80 (21.1)

-C4-
50
-C7Y-
(13.2) 40 70 25{255} 100 25{255} 85
(10.6) (18.5) (3571) (26.4) (3571) (22.4)
-C8-

Note) The maximum flow rate of each valve depends on the pressure. For details, see pages S-9 and S-10.

S-1
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 2

SS-G01 SS-G03
DC Solenoid DC Solenoid
AC Solenoid AC Solenoid
Built-in Rectifier Built-in Rectifier
C* E* D* C* E* D*
Maximum
Working P, A, B ports 35(25)MPa{357(255)kgf/cm2}(Note1) (5000psi)
Pressure
Maximum
Allowable T port 21MPa{214kgf/cm2} (3000psi) 16MPa{163kgf/cm2} (2285psi)
Backpressure
Standard Type 300 300 300 240
Switches/min. 120 120
Shockless Type − 120 − 120
Standard Indicator light R R
Shockless − F − F
− −
Option

Surgeless G G G G
With manual push-button N N
Quick Return − Q − − Q −
Weight Double Solenoid 1.8 2.0 4.2 5.5
(kg) Single Solenoid 1.4 1.5 3.5 4.1
Dust Resistance/Water Resistance Rank JIS C 0920 IP64 (Dust-tight, Splash-proof)
Environment

Ambient Temperature − 20 to 50°C


Operating

Temperature Range − 20 to 70°C


Operating
Fluid

Viscosity Range 15 to 300mm2/s


Filtration 25 microns or less
M6 × 70 (Four)
M5 × 45 (Four)
Size × Length
Mounting bolt

(M8 × 70 (Four))
10–24 × 1 3/4
1/4–20 × 2 3/4
M6 10 to 13N.m{102 to 133kgf.cm}
M5 5 to 7N.m{51 to 71kgf.cm}
Tightening Torque (M8 20 to 25N.m{204 to 255kgf.cm})
10–24 3.6–5.1Lbs.ft.
1/4–20 7.2–9.4Lbf.ft.

Note) 1. Maximum operating pressure depends on the valve type. For details, see page S-1.
2. For mounting bolts, use 12T or equivalent.

Notes
zPipe system so that tank line is nDo not supply electric power to the uous in order that the changeover
always filled with oil. AC solenoid unless the coil is position may be firmly maintained.
xSurge pressure should be kept mounted to the valve. ⁄0Resistance force against the manu-
below maximum tank line back mProvide drain piping from the T al override pin changes, depending
pressure rating. port, when valve spool types are on the back pressure of the tank
cWhen using a 4-way valve as a 2- A2X, H2X, E2X. line.
way or 3-way and blocking unused ,If the changeover position is kept ⁄1Solenoid coil could be hot by con-
ports lowers the maximum flow. under high pressure for an extend- tinuous operation. Do not touch the
vKeep hydraulic oil clean. (Degree of ed period, malfunctions may occur coil directly by hand.
contamination: NAS grade 12 or due to hydraulic lock. Please con- ⁄2Gasket dimension
better). When petroleum hydaulic sult us when you have such appli- SA/SS-G01 = ISO 4401-03-02-0-94
oil is used, it should conform to ISO cation. SA/SS-G03 = ISO 4401-05-04-0-94
VG32, 46. .When the detent-type (E2X, E3X,
bDo not exceed permissible voltage E3Z) is used, we recommend that
range of the coil used. the electric power supply be contin-

S-2
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 3

¡Solenoid Assembly Specifications


Power

Solenoid
Voltage Frequency For SS-G01 For SS-G03

Type
Supply
(V) (Hz) Solenoid Coil Drive Current Holding Current Holding Power Allowable
Voltage Range
Solenoid Coil Drive Current Holding Current Holding Power Allowable
Voltage Range
Type Type (A) (A) (W) (V) Type (A) (A) (W) (V)

50 2.2 0.52 25 80 to 110 5.4 0.92 36.0 80 to 110


AC100
C1 60 EDC64-C1 2.0 0.38 22 ECB64-C1 4.6 0.62 34.0
90 to 120 90 to 120
AC110 60 2.2 0.46 28 5.0 0.78 42.0

50 2.0 0.47 25 90 to 120 5.0 0.85 36.0 90 to 120


AC110
C115 60 EDC64-C115 1.8 0.35 22 ECB64-C115 4.2 0.57 34.0
100 to 130 100 to 130
AC115 60 2.0 0.42 28 4.6 0.72 42.0
AC

50 1.1 0.26 25 160 to 220 2.7 0.46 36.0 160 to 220


AC200
C2 60 EDC64-C2 1.0 0.19 22 ECB64-C2 2.3 0.31 34.0
180 to 240 180 to 240
AC220 60 1.1 0.23 28 2.5 0.39 42.0

50 1.0 0.24 25 180 to 240 2.5 0.42 36.0 180 to 240


AC220
C230 60 EDC64-C230 0.91 0.17 22 ECB64-C230 2.1 0.29 34.0
200 to 260 200 to 260
AC230 60 1.0 0.21 28 2.3 0.36 42.0

E1 AC100 50/60 EDC64-E1-1A 0.37 27 90 to 110 ECB64-E1 0.40 34.0 90 to 110


DC with Built-in Rectifier

AC110 0.26 25 0.33 31.0


E115 50/60 EDC64-E115-1A 100 to 125 ECB64-E115 100 to 125
AC115 0.27 27 0.34 34.0

E2 AC200 50/60 EDC64-E2-1A 0.15 26 180 to 220 ECB64-E2 0.22 37.0 180 to 220

AC220 0.12 24 0.16 30.0


E230 50/60 EDC64-E230-1A 200 to 250 ECB64-E230 200 to 250
AC230 0.13 27 0.17 33.0

D1 DC12 ⎯ EDC64-D1-1A 2.2 26 10.8 to 13.2 ECB64-D1 2.6 31.0 10.8 to 13.2
DC

D2 DC24 ⎯ EDC64-D2-1A 1.1 26 21.6 to 26.4 ECB64-D2 1.5 36.0 21.6 to 26.4

Understanding Model Numbers


SS – G 03 – A 3 X – R – C2 – J21

S-3
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 4

Options (Auxiliary Symbol Explanations)

Shockless Type Surgeless type


(Auxiliary Symbol: F) (Auxiliary Symbol: G)

Features Effects Features Effects


¡Smooth start and stop perfor- ¡Eliminates shocks in the pip- ¡Suppresses the surge volt- ¡Improves the reliability of the
mance ing system. age. control relay.
¡Quiet operation ¡Prevents the piping connec- ¡Eliminates sparks between ¡Extends the life of conven-
¡Long life and reliable opera- tions from leaking oil. relay contacts. tional relays.
tions ¡Extends the life of the ¡Extends the life of the relay ¡Can be operated with a
hydraulic components. contact. miniature relay.
¡Maintenance-free operation ¡The RAC rectifier built-in DC
of the hydraulic system. model eliminate sparks at the
control relay contact. It can
be directly operated wigh a
PLC (programmable logic
controller).

Surge suppressor
Relay contact
φ 63x φ 35x300 W=150kg
DC power
supply

R=1Ω
Voltage
Current
A B

SS-G03-C5-FR-D2-J21
Storage oscilloscope
P T

Spark time

Dry type Shockless type Normal form Surgeless time

Manual Button Type Quick Return


(Auxiliary Symbol: N) (Auxiliary Symbol: Q)

¡Handling
zThis type is used in the case of power sup-
Push-button ply type E* (with built-in rectifier) to shorten
Can be locked by pressing the spring return time. This also applies to
the button and rotating 90°.
D*.
xThe quick return mechanism is built in.
φD

Stroke S
L SW
Power supply

Surge absorber

Recovery Time
Rectifier Circuit

Limiter Circuit

Solenoid
Full Wave

Model L S D
133.5
AC solenoid
(5.26) 7.5 30
SS-G01
140.5 (0.30) (1.18)
DC solenoid
(5.53)
155.5
AC solenoid
(6.12) 9.5 35
SS-G03
173.5 (0.37) (1.38)
DC solenoid
(6.83)

S-4
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 5

Holes for temporary nameplate or customer’s


Installation Dimension Drawings Indicator light nameplate mounting holes for wiring.

AC Solenoid SOL b Recommended nameplate dimensions.


Self-tapping screws for mounting; 3.5 x 10.
SS-G01-A**-R-C*-E31 (0.14 x 0.39)
T
SS-G01-H**-R-C*-E31

26(1.02)
32(1.26)
B
A
Note)
SS-G01-H**-R**-E31 P
The solenoid is on the opposite side of that shown for SOLa in φ 2.8(Dia 0.11)
12
the illustrations shown here. φ 7.5 (0.47)
2 to G (Previously PF) 1/2 (Did 0.30) Indicator light
SOL a

87(3.43)
71.5(2.81)
48(1.89)

37.5(1.48)
SOL b

25.5(1.00)
5.5(Dia 0.22)
46 66(2.60)
(1.81) 102(4.02) 48.5(1.91)
Manual push-button 150.5(5.93)

SS-G01-C **-R-C*-E31
SS-G01-E **-R-C*-E31

SOL b SOL a

102(4.02) 102(4.02)
49.8(1.96) 204(8.03)
Space required for coil removal
DC Solenoid and Rectifier
SS-G01-A **-R-D/E*-E31
SS-G01-H **-R-D/E*-E31
SS-G01-C **-R-D/E*-E31
SS-G01-E **-R-D/E*-E31 SOL b SOL a

φ 5.5(Dia 0.22)
(1.48)
37.5

109(4.29) 48.5(1.91)
157.5(6.20)
60.5(2.38) 218(8.58)
Space required for coil removal

For sub plate SS-G01


Model No. E Weight
MSA-01X-E10 1/4 1.2kg
MSA-01Y-E10 3/8 1.2kg 98(3.86)
7.5 83(3.27) 7.5
Gasket Surface Dimensions (0.30) (0.30)
20 40.5(1.59)
ISO 4401-03-02-0-94 71.5(2.81)
( ) (0.79) 30.2(1.19)
7.5(0.30)

0.75(0.03)

30(1.18)
12(0.47)

JIS B 8355 D-03-02-0-94 41.5(1.63)


5.1(0.20)

21.5(0.85)
12.7 27(1.06) 11.5(0.45)
27.5(1.08) (0.45)
11.5

(0.50)
T
43.5(1.71)

T
15.5(0.61)
70(2.76)
55(2.17)
31.75(1.25)

25.9(1.02)
31(1.22)

A B
P B A

P
(0.30)

4- φ 7.5(Dia 0.30)
7.5

4-10-24x0.47tap 4-“E” NPT


4- φ 9.5x1counterbore(Dia 0.37 x 0.04)
φ 5.5hole(Dia 0.22)

S-5
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 6

Holes for temporary nameplate or customer’s


Installation Dimension Drawings Indicator light nameplate mounting holes for wiring.
AC Solenoid SOL. b Recommended nameplate dimensions.
Self-tapping screws for mounting; 3.5 x 10.
SS-G03-A**-R-C*-E21 (0.14 x 0.39)
P
SS-G03-H**-R-C*-E21

26(1.02)
32(1.26)
B
T T
A

φ 2.8(Dia 0.11)
Note) 12(0.47)
SS-G03-H**-R-**-J21 Indicator light
The solenoid is on the opposite side of that shown for SOLa in SOL. a
the illustrations shown here.

SS-G03-**-*R-**-J21 SS-G03-**-*R-**-21
φD φ6.8(Dia 0.27) φ8.5(Dia 0.33) 2 to G (Previously PF) 1/2
L 60.5(2.38) 58(2.28)

φD

105.5(4.15)
92(3.62)
68.5(2.70)
SOL. b

36(1.42)

L
SS-G03-C**-R-C*-E21 93(3.66)
70(2.76)
SS-G03-E**-R-C*-E21 117.5(4.63) 60.5(2.38)
Manual push-button
178(7.01)

SOL. b SOL. a
DC Solenoid and Rectifier
SS-G03-A **-R-D*/E*-E21
SS-G03-H **-R-D*/E*-E21 117.5(4.63) 117.5(4.63)
55(2.17) 235(9.26)
SS-G03-C **-R-D*/E*-E21
Space required for coil removal
SS-G03-E **-R-D*/E*-E21

SOL. b SOL. b

4- φ 17.5x2 counterbore(Dia 0.69 x 0.08) 135.5(5.33) 60.5(2.38)


77(3.03) 196(7.72)
(φ 17.5x10.8)
54(2.13) φ 11 holes(Dia 0.43) 63(2.48) 271(10.67)
23.8(0.94)
20.6(0.81) Space required for coil removal
4-1/4-20x0.47tap
1.6(0.06)

P
114(4.49)
70(2.76)
92(3.62)

16.6(0.65)
46(1.81)

A B For sub plate SS-G03


T
Mounting bolt Model No. E Weight

MSA-03-E10 3/8
4- φ 11 holes 1/4-20 2.3kg
MSA-03X-E10 1/2
9.5(0.37)

93(3.66)
25(0.98)

(Dia 0.43)
100(3.94) Gasket surface dimensions
ISO 4401-05-04-0-94
( )
(1.38)
35

JIS B 8355 D-05-04-0-94


5(0.20)

A
(0.87) (1.26)
22 32

T B

5(0.20)
4-“E” NPT
30 16
(1.18) (0.63)

S-6
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 7

Wiring Diagram

Ground terminal Common terminals


Note)
1.In the case of a double solenoid valve, a common terminal is
provided to simplify wiring. When the common terminal is not
COM
used, remove the terminal screws.
SOL b SOL a
2.Use the ground terminal when grounding is required.
3.In the case of a solderless terminal, M3 screws.
4.Tighten terminal screws to a torque of 0.5 to 0.7Nm {5.1 to
7.1kgf.cm}.
SOL b Ground terminal
SOL a

Electrical Circuit Diagram

Type Model No. Electrical Circuit

50/60Hz

G01 E31
AC Solenoid SS- -***-R-C*-
G03 E21
COM

50/60Hz

AC Solenoid G01 E31


SS- -***-GR-C*-
Surgeless Type G03 E21
COM

50/60Hz

G01 E31
Built-in Rectifier SS- -***-R-E*-
G03 E21
COM

G01 E31
DC Solenoid SS- -***-R-D*-
G03 E21
COM

DC Solenoid G01 E31


SS- -***-GR-D*-
Surgeless Type G03 E21
COM

Built-in Rectifier G01 E31


SS- -***-QR-E*- See page E-4 for more information.
Quick Return Type G03 E21

S-7
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 8

Performance Curves Hydraulic Operating Fluid Viscosity 32mm2/s


Pressure Loss Characteristics
Pump
{kgf/cm 2 } Type Flow Path P/A P/B A/T B/T P/T
2.4 24.5
A2X, H2X, E2X d d − − −
2.2 22.4
A3X, H3X b b b b −
2.0 20.4
f e E3X b b b b −
1.8 18.4

Pressure Loss

A3Z, H3Z, E3Z a a a a


1.6 16.3
c b a A4, H4, C4 a a a a a
MPa

1.4 14.3
A5, H5, C5, C6S b b b b −
1.2 12.2 SS-G01
C1, C1S b b a b −
1.0 10.2
C2 a b b b −
0.8 8.2
d C6 b b a a −
0.6 6.1
C7Y f f e e c
0.4 4.1
C8 a f b e c
0.2 2.0
C9 a a b b −
0 20 40 60 80 100
Flow rate r/min

g e d {kgf/cm 2 }
Pump
1.6 16.3 Type Flow Path P/A P/B A/T B/T P/T

A2X, H2X, E2X e e − − −


1.4 14.3
A5 − c c − −
Pressure Loss

1.2 12.2
H5 c − − c −
MPa

1.0 10.2 A3X, H3X, E3X c c d d −

c A3Z, H3Z a a d d −
0.8 8.2
f E3Z b b a a −
0.6 6.1
b C1 c c a c −
SS-G03
0.4 4.1 C2 a c c c −
A4, H4, C4 a a a a a
0.2 2 a
C5, C1S, C6S c c c c −
0 20 40 60 80 100 120 140 160 C6 c c a a −
C7Y g g g g f
Flow rate r/min
C8 a g a g f

C9 a a c c −

Switching Response Time


Response Time (sec)
Model No. Measurement Conditions
Solenoid ON Spring Return

SS-G01-**-R-C*-E31 0.02 to 0.03 0.02 to 0.03 ⎫


SS-G01-**-(G)R-D*-E31 0.03 to 0.04 0.02 to 0.04 ⎪
⎪ 14MPa{143kgf/cm2}
SS-G01-**-R-E*-E31 0.03 to 0.04 0.07 to 0.10 ⎬
SS-G01-**-F(G)R-D*-E31 0.07 to 0.10 0.04 to 0.07
⎪ 30r/min

SS-G01-**-FR-E*-E31 0.07 to 0.10 0.10 to 0.15 ⎭
SS-G03-**-R-C*-E21 0.02 to 0.03 0.02 to 0.03 ⎫
SS-G03-**-(G)R-D*-E21 0.06 to 0.09 0.03 to 0.05 ⎪
⎪ 14MPa{143kgf/cm2}
SS-G03-**-R-E*-E21 0.07 to 0.10 0.10 to 0.15 ⎬
SS-G03-**-F(G)R-D*-E21 0.13 to 0.15 0.08 to 0.15
⎪ 70r/min

SS-G03-**-FR-E*-E21 0.10 to 0.15 0.15 to 0.20 ⎭
Note) 1.The switching response time changes slightly with operating conditions (pressure, flow rate, viscosity, etc.)
2.In the case of power supply type E* (with built-in rectifier), the spring return time using Quick Return (option symbol: Q) is the same as D*.

S-8
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 9

Pressure − Flow Volume Allowable Value

Standard Form, with AC, DC solenoid Shockless Type, with DC solenoid


Size Size
SS/SA-G01-**-R-**-E31 SS/SA-G01-**-FR-**-E31
Operation Operation
b A B a b A B a b A B a b A B a b A B a b A B a
Example Example
Operation P T P T P T Operation P T P T P T
Symbol Symbol
A2X, H2X − K K A2X, H2X − P P
E2X − J J E2X − O O
A3X, H3X B K K A3X, H3X L P P
E3X A J J E3X L O O
A3Z, H3Z D D D A3Z, H3Z L L L
E3Z D D D E3Z L L L
A5 A − I A5 L − P
H5 A I − H5 L P −
C1, C6 Note1) C(E) I I C1, C6 M P P
C1S, C5, C6S A I I C1S, C2, C5, C6S, C9 L P P
C2, C9 A K K A4, H4 L L L
A4 F F F C4 L L L
H4 F F F C7Y, C8 N P P
C4 F F F
C7Y, C8 Note2) G(H) K K
Note) 1.Letter in parentheses is for AC solenoid.
2.Letter in parentheses is for solenoid with built-in rectifier (E*), but
without Quick Return, and for DC solenoid (D*) with surge voltage
absorbing diode on the electrical circuit.

A L

Flow rate
100 50

r/min
40
M
80 30
B N
C O
Flow rate

20
r/min

D
60 10
E P
F
0
G 10 20 25
40 {102} {204} {255}
H
Pressure MPa
I {kgf/cm 2}
20 J

K
0
10 20 30 35
{102} {204} {306} {357}
Pressure MPa
{kgf/cm 2}

S-9
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 10

Pressure − Flow Volume Allowable Value


Standard Form, with AC Solenoid Standard Form, with DC Solenoid
Model No.
SS-G03-**-R-C*-E21 SS-G03-**-R-**-E21
Operation
Example b
A B
a b A B a b
A B
a b
A B
a b A B a b
A B
a
Operation
Symbol P T P T P T P T P T P T

A2X − F E ⎯ E F
H2X − E F ⎯ F E
E2X − C C ⎯ C C
A3X A E E A D F
H3X A E E A F D
A3Z A A C A C C
H3Z A C A A C C
E3X, E3Z A C C A C C
A5 A − D A − E
H5 A D − A E −
C1, C1S, C5, C6, C6S A D D A E E
C2 A G D A G E
A4, H4, C4 A A A A A A
C9 A G G A G G
C7Y, C8 B B B Note1) B(H) B(H) B(H)

140 160 A
A
120 140

Flow rate
Flow rate

100 120

r/min
r/min

100 B
80
80 C
60 B
60 H
F G
40 E D
C 40
E D
20 G 20 F

10 20 30 35 0 10 20 30 35
0
{102} {204} {306} {357} {102} {204} {306} {357}
2 2
Pressure MPa{kgf/cm } Pressure MPa{kgf/cm }

Shockless Type, with DC solenoid


Model No.
SS-G03-**-FR-**-E21
Operation
Example b
A B
a b A B a b
A B
a
Operation
Symbol P T P T P T

A2X − E F
H2X − F E
E2X − C C
A3X A D F
H3X A F D
A3Z A C C
H3Z A C C
E3X, E3Z A C C
A5 A − E
H5 A E −
C1, C1S, C5, C6, C6S A E E
C2 A G E
A4, H4, C4 A A A
C9 A G G
C7Y, C8 Note1) B(H) B(H) B(H)
140
A
120
Flow rate

100
r/min

B
80

60
G H
E
40
C
20 F D

0 10 20 25
{102} {204} {255}
2
Pressure MPa{kgf/cm }

Note) 1.Letter in parentheses is for solenoid with built-in rectifier (E*), but without Quick Return, and for DC solenoid (D*) with surge voltage absorbing
diode on the electrical circuit.
2.There is no shockless type for the AC solenoid (C*), so use a solenoid with built-in rectifier (E*) when shockless operation is required with an AC
power supply.
3.The maximum flow rate is the allowable value of each port.

S-10
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 11

Cross-sectional Drawing
SS-G01-A**-R-C*-E31 SS-G01-C**-R-C*-E31

13 20 14 15 16 13 20 14 15 16

10 18 11 12 6 19 17 3 1 7 4 5 8 2 11 12 9 19 5 4 17 3 1 7 18 10

SS-G01-A**-R-D/E*-E31 SS-G01-C**-R-D/E*-E31

13 20 14 15 16 13 20 14 15 16

10 18 11 12 6 19 17 3 1 7 4 5 8 2 11 12 9 19 5 4 17 3 1 7 18 10

List of Sealing Parts Part No. Part Name Part No. Part Name
1 Body 11 Rod
Part Q'ty
Part Name Part Number 2 Plug 12 Solenoid guide
No. Single Double
3 Spool 13 Solenoid coil
Solenoid Solenoid

17 O-ring AS568-012(Hs90) 4 4 4 Retainer A 14 Packing


5 Retainer B 15 Terminal box kit
18 O-ring 1A-P20 1 2
6 Retainer C 16 Nameplate
19 O-ring 1B-P18 2 2 7 Spacer 17 O-ring
20 O-ring S-25 1 2 8 Spring A 18 O-ring
9 Spring C 19 O-ring
Note) 1A and 1B are JIS Standard B 2401, while AS568 10 Nut 20 O-ring
is SAE standard.

Seal Kit Number


Single Solenoid Double Solenoid
EDCS-A EDCS-C

S-11
05S_Solenoid Valve(P01-12)_E.q 07.6.7 3:58 PM Page 12

Cross-sectional Drawing
SS-G03-A**-R-C*-E21 SS-G03-C**-R-C*-E21

19 20 12 15 16 18 2 19 20 12 15 16 18 10

8 10 11 9 7 5 3 17 1 6 4 8 11 9 7 4 3 17 1 6

SS-G03-A**-R-D/E*-E21 SS-G03-C**-R-D/E*-E21

19 20 12 15 16 18 2 19 20 12 15 16 18 10

8 10 14 13 11 9 7 5 3 17 1 6 4 8 14 13 11 9 7 4 3 17 1 6

List of Sealing Parts Part No. Part Name Part No. Part Name
1 Body 14 Coil yoke
Part Type/Part Number Q'ty
Part Name 2 Plug 15 Terminal box kit
No. AC SOL. DC SOL. Single Double
3 Spool 16 Nameplate
Solenoid Solenoid

17 O-ring AS568-014(Hs90) 5 5 4 Retainer 17 O-ring


5 Retainer B 18 O-ring
18 O-ring 1B-P28 2 2 6 Spacer 19 O-ring
19 O-ring 1A-P26 AS568-026 1 2 7 Spring 20 O-ring
8 Nut
20 O-ring AS568-029 2 2
9 Rod
Note) 1A and 1B** indicate JIS Standard B 2401-1A/1B-**. 10 Solenoid guide
11 Solenoid coil
12 Packing B
Seal Kit Number
13 Coil case
AC SOL. DC SOL.

Single Solenoid Double Solenoid Single Solenoid Double Solenoid

ECBS-AA ECBS-CA ECBS-AD ECBS-CD

S-12
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 13

WET TYPE SOLENOID OPERATED


DIRECTIONAL CONTROL VALVE
SA Series(Wiring System: DIN Connector Type) 26.4 to 42.3gpm
Wet Type Solenoid Valve 5000psi

Features
qVery long life eShockless yWide-ranging backward compatibility makes it
The movable iron core of the wet type solenoid A switching speed adjustment mechanism simple to replace previous valve models with
is immersed in oil, which keeps it lubricated and enables direct, shockless operation (Option F). this one. Combining this valve with a modular
cushions it from impact and vibration, ensuring rNo surge voltage valve contributes to the compact configuration of
very long life. Sparking and surge voltage during solenoid the overall device.
wLow switching noise switching is canceled for stable switching uGlobal support (G01 size)
The wet-type solenoid valve provides very low (Option G). Meets overseas safety standards (CE, UL, and
core switching noise, for quiet operation. tEasy coil replacement CSA). It can be safely used anywhere in the
A DIN connector type coil enables one-touch coil world. Contact your agent for certified products.
replacement.
Specifications
SA-G01 SA-G03
Standard Type
Model No.
Standard Type Shockless Type DC Solenoid Type Shockless Type
AC Solenoid Type
(With built-in rectifier)
Operation Maximum Maximum Working Maximum Maximum Working Maximum Maximum Working Maximum Maximum Working Maximum Maximum Working
JIS Symbol Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure
Symbol r/min MPa{kgf/cm2} r/min MPa{kgf/cm2} r/min MPa{kgf/cm2} r/min MPa{kgf/cm2} r/min MPa{kgf/cm2}
(gpm) (psi) (gpm) (psi) (gpm) (psi) (gpm) (psi) (gpm) (psi)
-A2X-
40
-H2X- 30 30 (10.6) 85 85
(7.9) (7.9) 85 (22.4) (22.4)
-E2X-
(22.4)
-A3X-
80
(21.1)
-H3X-
100
-E3X-
(26.4)
-A3Z-
65
-H3Z-
(17.1)
-E3Z-

--A4-
50
(13.2) 35{357} 35{357}
-H4-
(5000) (5000)
35 25{255} 25{255}
-A5-
(5000) 50 (3571) 130 160 130 (35.71)
(13.2) (34.3) (42.2) (34.3)
-H5-

-C2-
100
-C5-
(26.4)
-C9-

-C1S-

-C6S-

-C1- AC Solenoid
65 (17.1)
DC Solenoid
-C6- 80 (21.1)

-C4-
50
-C7Y-
(13.2) 40 70 25{255} 100 25{255} 85
(10.6) (18.5) (3571) (26.4) (3571) (22.4)
-C8-

Note) The maximum flow rate of each valve depends on the pressure. For details, see pages S-9 and S-10.

S-13
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 14

SA-G01 SA-G03
DC Solenoid DC Solenoid
AC Solenoid AC Solenoid
Built-in Rectifier Built-in Rectifier
C* E* D* C* E* D*
Maximum
Working P, A, B ports 35(25)MPa{357(255)kgf/cm2}(Note1)
Pressure
Maximum
Allowable T port 21MPa{214kgf/cm2} 16MPa{163kgf/cm2}
Backpressure
Standard Type 300 300 240 240
Switches/min. 120 120
Shockless Type ⎯ 120 ⎯ 120
Indicator light R R
Shockless ⎯ F ⎯ F
⎯ ⎯
Option

Surgeless G G G G
G Screw Connector J ⎯ J J ⎯ J
With manual push-button N N
Quick Return ⎯ Q ⎯ ⎯ Q ⎯
Weight

Double Solenoid 1.8 2.0 4.2 5.5


(kg)

Single Solenoid 1.4 1.5 3.5 4.1


Dust Resistance/Water Resistance Rank JIS C 0920 IP65 (Dust-tight, Waterjet-proof) (Note 2)
Environment

Ambient Temperature − 20 to 50°C


Operating

Temperature Range − 20 to 70°C


Operating
Fluid

Viscosity Range 15 to 300mm2/s


Filtration 25 microns or less
M6 × 70 (Four)
Size × Length M5 × 45 (Four)
(M8 × 70 (Four) )
Mounting bolt

10 −24 × 1 3/4
1/4−20 × 2 3/4
M6 10 to 13N.m{102 to 133kgf.cm}
M5 5 to 7N.m{51 to 71kgf.cm}
Tightening Torque (M8 20 to 25N.m{204 to 255kgf.cm})
10−24 to 3.6−5.1Lbs.ft.
1/4−20 to 7.2−9.4Lbf.ft.

Note) 1.Maximum operating pressure depends on the valve type. For details, see page S-13.
2.The power supply type for E* is IP64 (dust-tight, splash-proof).
3.For mounting bolts, use 12T or equivalent.

Notes
zPipe system so that tank line is nDo not supply electric power to the uous in order that the changeover
always filled with oil. AC solenoid unless the coil is position may be firmly maintained.
xSurge pressure should be kept mounted to the valve. ⁄0Resistance force against the manu-
below maximum tank line back mProvide drain piping from the T al override pin changes, depending
pressure rating. port, when valve spool types are on the back pressure of the tank
cWhen using a 4-way valve as a 2- A2X, H2X, E2X. line.
way or 3-way and blocking unused ,If the changeover position is kept ⁄1Solenoid coil could be hot by con-
ports lowers the maximum flow. under high pressure for an extend- tinuous operation. Do not touch the
vKeep hydraulic oil clean. (Degree of ed period, malfunctions may occur coil directly by hand.
contamination: NAS grade 12 or due to hydraulic lock. Please con- ⁄2Gasket dimension
better). When petroleum hydaulic sult us when you have such appli- SA/SS-G01 = ISO 4401-03-02-0-94
oil is used, it should conform to ISO cation. SA/SS-G03 = ISO 4401-05-04-0-94
VG32, 46. .When the detent-type (E2X, E3X,
bDo not exceed permissible voltage E3Z) is used, we recommend that
range of the coil used. the electric power supply be contin-

S-14
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 15

¡Solenoid Assembly Specifications


Power

Solenoid
Voltage Frequency For SA-G01 For SA-G03

Type
Supply
(V) (Hz) Solenoid Coil Drive Current Holding Current Holding Allowable Solenoid Coil Drive Current Holding Current Holding Allowable
Voltage Voltage
Type Type (A) (A) Power (W) Range (V) Type (A) (A) Power (W) Range (V)

50 2.2 0.52 25 80 to 110 5.4 0.92 36.0 80 to 110


AC100
C1 60 EAC64-C1 2.0 0.38 22 EBB64-C1 4.6 0.62 34.0
90 to 120 90 to 120
AC110 60 2.2 0.46 28 5.0 0.78 42.0

50 2.0 0.47 25 90 to 120 5.0 0.85 36.0 90 to 120


AC110
C115 60 EAC64-C115 1.8 0.35 22 EBB64-C115 4.2 0.57 34.0
100 to 130 100 to 130
AC115 60 2.0 0.42 28 4.6 0.72 42.0
AC

50 1.1 0.26 25 160 to 220 2.7 0.46 36.0 160 to 220


AC200
C2 60 EAC64-C2 1.0 0.19 22 EBB64-C2 2.3 0.31 34.0
180 to 240 180 to 240
AC220 60 1.1 0.23 28 2.5 0.39 42.0

50 1.0 0.24 25 180 to 240 2.5 0.42 36.0 180 to 240


AC220
C230 60 EAC64-C230 0.91 0.17 22 EBB64-C230 2.1 0.29 34.0
200 to 260 200 to 260
AC230 60 1.0 0.21 28 2.3 0.36 42.0

E1 AC100 50/60 EAC64-E1-1A 0.31 27 90 to 110 EBB64-E1 0.40 34.0 90 to 110


DC with Built-in Rectifier

AC110 0.26 25 0.33 31.0


E115 50/60 EAC64-E115-1A 100 to 125 EBB64-E115 100 to 125
AC115 0.27 27 0.34 34.0

E2 AC200 50/60 EAC64-E2-1A 0.15 26 180 to 220 EBB64-E2 0.22 37.0 180 to 220

AC220 0.12 24 0.16 30.0


E230 50/60 EAC64-E230-1A 200 to 250 EBB64-E230 200 to 250
AC230 0.13 27 0.17 33.0

D1 DC12 ⎯ EAC64-D1-1A 2.2 26 10.8 to 13.2 EBB64-D1 2.6 31.0 10.8 to 13.2
DC

D2 DC24 ⎯ EAC64-D2-1A 1.1 26 21.6 to 26.4 EBB64-D2 1.5 36.0 21.6 to 26.4

Understanding Model Numbers

S-15
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 16

Options (Auxiliary Symbol Explanations)

G Screw Adapter With manual push-button


(Auxiliary Symbol: J) (Auxiliary Symbol: N)

L 45(1.77) (Previously PF)1/2

(Dia 1.10)
Push-button
Can be locked by pressing

φ 28
the button and rotating 90°.

φD
PG11

H Stroke S
L

Model No. L H Model No. L S D


AC Solenoid 133.5(5.26)
SA-G01 49(1.92) 81(3.19) SA-G01 7.5(0.30) 30(1.18)
DC Solenoid 140.5(5.53)
AC Solenoid 155.5(6.12)
SA-G03 60.5(2.38) 100.5(3.96) SA-G03 9.5(0.37) 35(1.38)
DC Solenoid 173.5(6.83)

Quick Return Type


Other Options
(Auxiliary Symbol: Q)

¡Handling Note) For information about the shockless and surgeless


options, see page S-4.
zThis type is used in the case of power supply type E*
(with built-in rectifier) to shorten the spring return time.
This also applies to D*.
xThe Quick Return device is not built in. Mount to the
electrical box, etc.
cEven when power supply type E* is equipped with a
Quick Return mechanism, response is not fast.
(Replace the DIN connector with EA41-1A or EA41-
R*-1C, without changing the coil.)
vWhen multiple Quick Return devices are used, do not
wire COM to the output side (pin number 3 and 4 side).

SW
Surge absorber

Full Wave Rectifier

1 3
Power supply

Recovery Time
Limiter Circuit

Solenoid

+
Circuit


2 4

50(1.97)
48(1.89) 21(0.83)
5(0.20)
36±0.2 2 to φ 4.5 hole
(1.42±0.01)
(Dia 0.18)
to 2

–4

32
(1.26)
1 to

3+

M3.5x0.6 Terminal number


Nameplate

S-16
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 17

Installation Dimension Drawings


T
AC Solenoid B
SA-G01-A**-*-C*-E31 A
P
SA-G01-H**-*-C*-E31
φ 7.5(Dia 0.30)
Note) SA-G01-H**-R-**-31 49(1.93)
The solenoid is on the opposite side of that shown for
SOLa in the illustrations shown here.

92.5(3.64)
81(3.19)
48(1.89)
SOL b

(1.48)
37.5
φ 5.5(Dia 0.22)

25.5(1.00)
46(1.81)
66(2.60)
Manual push-button
102(4.02) 39(1.54)
141(5.55)
SA-G01-C**-R-C*-E31
SA-G01-E**-R-C*-E31

SOL b SOL a

102(4.02) 102(4.02)
49.8(1.96) 204(8.03)
Space required for coil removal
DC Solenoid and Rectifier
SA-G01-A**-D*/E*-E31
SA-G01-H**-D*/E*-E31 49(1.93)
SA-G01-C**-D*/E*-E31
SA-G01-E**-D*/E*-E31
1)92.5(3.64)
2)81(3.19)

Note) 1.SA-G01-H**-*-D*/E*-E31
48(1.89)

The solenoid is on the opposite side of that shown for


SOL b SOL a

37.5(1.48)
SOLa in the illustrations shown here.
2.SA-G01-**-E*-E31
Dimension 1 is 96.
Dimension 2 is 73.
φ 5.5(Dia 0.22)
25.5(1.00)

46(1.81)
109(4.29) 39(1.54)
Manual push-button
148(5.83)
60.5(2.38) 218(8.58)
Space required for coil removal

For sub plate SA-G01


Model No. E Weight
MSA-01X-E10 1/4 1.2kg
MSA-01Y-E10 3/8 1.2kg 98(3.86)
7.5 83(3.27) 7.5
Gasket Surface Dimensions (0.30) 20 40.5(1.59) (0.30)
ISO 4401-03-02-0-94 71.5(2.81)
( ) (0.79) 30.2(1.19)
7.5(0.30)

0.75(0.03)

30(1.18)
12(0.47)

41.5(1.63)
5.1(0.20)

JIS B 8355 D-03-02-0-94 21.5(0.85)


12.7 27(1.06) 11.5(0.45)
27.5(1.08) (0.45)
11.5

(0.50)
T
43.5(1.71)

T
15.5(0.61)
70(2.76)
55(2.17)
31.75(1.25)

25.9(1.02)
31(1.22)

A B
P B A

P
(0.30)

4- φ 7.5(Dia 0.30)
7.5

4-10-34x0.47tap 4-“E” NPT


4- φ 9.5x1counterbore(Dia 0.37 x 0.04)
φ 5.5hole(Dia 0.22)

S-17
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 18

Installation Dimension Drawings


AC Solenoid P
SA-G03-A**-*-C*-E21 T
A B
T
SA-G03-H**-*-C*-E21

60.5(2.38)
Note) SA-G03-H**-*-C*-E21 φD
The solenoid is on the opposite side of that shown for

100.5(3.96)
112(4.41)
SOLa in the illustrations shown here.

68.5(2.70)
SA-G03-**-*-**-E21 SA-G03-**-*-**-E21
SOL. b
φD φ 6.8(Dia 0.27) φ 8.5(Dia 0.33)

L
36(1.42)
L 60.5(2.38) 58(2.28)
70(2.76) 93(3.66)
SA-G03-C**-*-C*-E21 Manual push-button 117.5(4.63) 60.5(2.38)
178(7.01)
SA-G03-E**-*-C*-E21

SOL. b SOL. a

117.5(4.63) 117.5(4.63)
55(2.17) 235(9.26)
DC Solenoid and Rectifier
SA-G03-A**-*-D*/E*-E21 Space required for coil removal
SA-G03-H**-*-D*/E*-E21
SA-G03-C**-*-D*/E*-E21 60.5(2.38)
SA-G03-E**-*-D*/E*-E21
Note) 1.SA-G03-H**-*-D*/E-E21
2)100.5(3.96)
1)112(4.41)

The solenoid is on the opposite side


of that shown for SOLa in the illustra-
68.5(2.70)

tions shown here.


2.SA-G03-**-E*-E21 SOL. b SOL. a
36(1.42)

Dimension 1 is 115.5. (4.55)


Dimension 2 is 92.5. (3.64)
70(2.76)
135.5(5.33) 60.5(2.38)
Manual push-button 196(7.72)
63(2.48) 271(10.67)
Space required for coil removal
4- φ 17.5x2 counterbore(Dia 0.69 x 0.08)
77(3.03)
(φ 17.5x10.8)
54(2.13) φ 11 holes(Dia 0.43)
23.8(0.94)
20.6(0.81)
4-1/4-20x0.47tap
1.6(0.06)

P
114(4.49)
70(2.76)
92(3.62)

16.6(0.65)
46(1.81)

A B
T For sub plate SA-G03
Mounting bolt Model No. E Weight
4- φ 11 holes 1/4-20 MSA-03-E10 3/8
9.5(0.37)

93(3.66)
25(0.98)

(Dia 0.43) 2.3kg


100(3.94) M6 MSA-03X-E10 1/2
M6 gasket surface dimensions
(1.38)
35

(
ISO 4401-05-04-0-94
JIS B 8355 D-05-04-0-94
)
5(0.20)

A
(0.87) (1.26)
22 32

T B

5(0.20)
4-“E” NPT
30 16
(1.18) (0.63)

S-18
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 19

¡Connectors

Model No. Wiring Electrical Circuit Diagram

Connect the power sup-


G01 C* E31 ply to terminals No.1
SA- -***- -
G03 D* (J)E21 and No. 2. The termi-
(EA41-1A) nal is ground. Use this
terminal as required.

G01 E31
SA- -***-R-C*-
G03 (J)E21
(EA41-R*-1C)

G01 E31
SA- -***-GR-C*-
G03 (J)E21
(EA41-GRC*-1C)
Connect the power sup-
ply to terminals No.1
and No. 2. The termi-
nal is ground. Use this
terminal as required.
G01 E31
SA- -***-R-D*-
G03 (J)E21
(EA41-DR*-1C)

G01 E31
SA- -***-GR-D*-
G03 (J)E21
(EA41-GRD*-1C)

G01 E31
SA- -***-E*-
G03 (J)E21 Connect the power sup-
(EA42-1B) ply to the terminals on
the board.
Power supply When ground connec-
terminal tion is required, remove
the board and use the
terminal. In this case,
do not connect the
G01 E31 power supply to the No.
SA- -***-R-E*-
G03 (J)E21 1 and No. 2 terminals.
(EA42-R*-1B)

G (Previously PF) 1/2

Symbols in parentheses indicate connector configuration.


Note) 1.Asterisks in the connector configuration and power supply symbols are fillers for the voltage symbol (1 or 2).
2.The connector cord diameter is φ 8 to 10. Anything outside this range causes water tightness to be lost.
3.The orientation of the connectors can be changed in 90° increments by changing the terminal block.
4.The cover cannot be removed unless the installation screws are removed.
5.When J is specified for the auxiliary symbol, a G screw conversion adapter is attached to the connector, and the wiring port is a G (previously PF)
1/2 screw (standard: PG11). EA42 and EA42-R* also have a G (previously PF) wiring port.
6.Use M3 for round type and Y type solderless terminals.
7.Tighten the M3 screws that secure connectors and terminals to a torque of 0.3 to 0.5Nm (3.1 to 5.1kgf.cm).
8.An EA-41-1A or EA41-R*-1C connector is used in the case of power supply type E* with Quick Return type Q.

S-19
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 20

Performance Curves Hydraulic Operating Fluid Viscosity 32mm2/s


Pressure Loss Characteristics
{kgf/cm 2 } Pump Type Flow Path P/A P/B A/T B/T P/T
2.4 24.5 A2X, H2X, E2X d d ⎯ ⎯ ⎯
2.2 22.4 A3X, H3X b b b b ⎯
2.0 20.4 E3X b b b b ⎯
f e
1.8 18.4 ⎯
A3Z, H3Z, E3Z a a a a
Pressure Loss

1.6 16.3
b a A4, H4, C4 a a a a a
c
MPa

1.4 14.3
A5, H5, C5, C6S b b b b ⎯
1.2 12.2 SA-G01
C1, C1S b b a b ⎯
1.0 10.2
C2 a b b b ⎯
0.8 8.2
d C6 b b a a ⎯
0.6 6.1
C7Y f f e e c
0.4 4.1
C8 a f b e c
0.2 2.0
C9 a a b b ⎯
0 20 40 60 80 100
Flow rate r/min
Pump Type Flow Path P/A P/B A/T B/T P/T

g e d {kgf/cm }2 A2X, H2X, E2X e e ⎯ ⎯ ⎯

A5 ⎯ c c ⎯ ⎯
1.6 16.3
H5 c ⎯ ⎯ c ⎯
1.4 14.3
A3X, H3X, E3X c c d d ⎯
Pressure Loss

1.2 12.2 A3Z, H3Z a a d d ⎯


MPa

E3Z b b a a
1.0 10.2
C1 c c a c ⎯
0.8 8.2 c SA-G03
f C2 a c c c ⎯

0.6 6.1 A4, H4, C4 a a a a a


b ⎯
C5, C1S, C6S c c c c
0.4 4.1
C6 c c a a ⎯
0.2 2 a
C7Y g g g g f

C8 a g a g f
0 20 40 60 80 100 120 140 160
C9 a a c c ⎯
Flow rate r/min

Switching Response Time


Response Time (sec)
Model No. Measurement Conditions
Solenoid ON Spring Return

SA-G01-**-(GR)-C*-E31 0.02 to 0.03 0.02 to 0.03 ⎫


SA-G01-**-(GR)-D*-E31 0.03 to 0.04 0.02 to 0.04 ⎪
⎪ 14MPa{143kgf/cm2}
SA-G01-**-(R)-E*-E31 0.03 to 0.04 0.07 to 0.10 ⎬
SA-G01-**-F(GR)-D*-E31 0.07 to 0.10 0.04 to 0.07
⎪ 30r/min

SA-G01-**-F(R)-E*-E31 0.07 to 0.10 0.10 to 0.15 ⎭

SA-G03-**-(GR)-C*-E21 0.02 to 0.03 0.02 to 0.03 ⎫


SA-G03-**-(GR)-D*-E21 0.06 to 0.09 0.03 to 0.05 ⎪
⎪ 14MPa{143kgf/cm2}
SA-G03-**-(R)-E*-E21 0.07 to 0.10 0.10 to 0.15 ⎬
SA-G03-**-F(GR)-D*-E21 0.13 to 0.15 0.08 to 0.15
⎪ 70r/min

SA-G03-**-F(R)-E*-E21 0.10 to 0.15 0.15 to 0.20 ⎭
Note) 1.The switching response time changes slightly with operating conditions (pressure, flow rate, viscosity, etc.)
2.In the case of power supply type E* (with built-in rectifier), the spring return time using Quick Return (option symbol: Q) is the same as D*.

S-20
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 21

Pressure − Flow Volume Allowable Value


Standard Form, with AC, DC solenoid Shockless Type, with DC solenoid
Size Size
SS/SA-G01-**-R-**-E31 SS/SA-G01-**-FR-**-E31
Operation Operation
b A B a b A B a b A B a b A B a b A B a b A B a
Example Example
Operation P T P T P T Operation P T P T P T
Symbol Symbol
A2X, H2X − K K A2X, H2X − P −
E2X − J J E2X − O P
A3X, H3X B K K A3X, H3X L P P
E3X A J J E3X L O L
A3Z, H3Z D D D A3Z, H3Z L L L
E3Z D D D E3Z L L P
A5 A − I A5 L −
H5 A I − H5 L P
C1, C6 Note1) C(E) I I C1, C6 M P
C1S, C5, C6S A I I C1S, C2, C5, C6S, C9 L P
C2, C9 A K K A4, H4 L L
A4 F F F C4 L L
H4 F F F C7Y, C8 N P
C4 F F F
C7Y, C8 Note2) G(H) K K

Note) 1.Letter in parentheses is for AC solenoid.


2.Letter in parentheses is for solenoid with built-in rectifier, but without Quick Return, and for DC solenoid with surge voltage absorbing diode on the
electrical circuit.

A L
100 50

Flow rate
r/min
40
M
80 30
B N
C O
Flow rate

20
r/min

D
60 10
E P
F
0
G 10 20 25
40 {102} {204} {255}
H Pressure MPa
{kgf/cm2}
I
20 J

K
0
10 20 30 35
{102} {204} {306} {357}
Pressure MPa
{kgf/cm2}

S-21
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 22

Pressure − Flow Volume Allowable Value


Standard Form, with AC, DC solenoid Standard Form, with DC solenoid
Model No.
SA-G03-**-C*-E21 SA-G03-**-**-E21
Operation
Example b
A B
a b A B a b
A B
a b
A B
a b A B a b
A B
a
Operation
Symbol P T P T P T P T P T P T

A2X ⎯ F E ⎯ E F
H2X ⎯ E F ⎯ F E
E2X ⎯ C C ⎯ C C
A3X A E E A D F
H3X A E E A F D
A3Z A A C A C C
H3Z A C A A C C
E3X, E3Z A C C A C C
A5 A ⎯ D A ⎯ E
H5 A D ⎯ A E ⎯
C1, C1S, C5, C6, C6S A D D A E E
C2 A G D A G E
A4, H4, C4 A A A A A A
C9 A G G A G G
C7Y, C8 B B B Note1) B(H) B(H) B(H)
140 160 A
A
120 140

Flow rate
Flow rate

100 120

r/min
r/min

100 B
80
80 C
60 B
60 H
F G
40 E D
C 40
E D
20 G 20 F

10 20 30 35 0 10 20 30 35
0
{102} {204} {306} {357} {102} {204} {306} {357}
2 2
Pressure MPa{kgf/cm } Pressure MPa{kgf/cm }
Shockless Type, with DC solenoid
Model No.
SA-G03-**-F-**-E21
Operation
Example b
A B
a b A B a b
A B
a
Operation
Symbol P T P T P T

A2X ⎯ E F
H2X ⎯ F E
E2X ⎯ C C
A3X A D F
H3X A F D
A3Z A C C
H3Z A C C
E3X, E3Z A C C
A5 A ⎯ E
H5 A E ⎯
C1, C1S, C5, C6, C6S A E E
C2 A G E
A4, H4, C4 A A A
C9 A G G
C7Y, C8 Note1) B(H) B(H) B(H)

140
A
120
Flow rate

100
r/min

B
80

60
G H
E
40
C
20 F D

0 10 20 25
{102} {204} {255}
2
Pressure MPa{kgf/cm }

Note) 1.Letter in parentheses is for solenoid with built-in rectifier (E*), but without Quick Return, and for DC solenoid (D*) with surge voltage absorbing
diode on the electrical circuit.
2.There is no shockless type for the AC solenoid (C*), so use a solenoid with built-in rectifier (E*) when shockless operation is required with an AC
power supply.
3.The maximum flow rate is the allowable value of each port.

S-22
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 23

Cross-sectional Drawing
SA-G01-A**-C*-E31 SA-G01-C**-C*-E31

13 20 14 15 16 13 20 14 15 16

10 18 11 12 6 19 17 3 1 7 4 5 8 2 11 12 9 19 5 4 17 3 1 7 18 10

SA-G01-A**-D/E*-E31 SA-G01-C**-D/E*-E31

13 20 14 15 16 13 20 14 15 16

10 18 11 12 6 19 17 3 1 7 4 5 8 2 11 12 9 19 5 4 17 3 1 7 18 10

List of Sealing Parts Part No. Part Name Part No. Part Name
1 Body 11 Rod
Part Q'ty
Part Name Part Number 2 Plug 12 Solenoid guide
No. Single Double
3 Spool 13 Solenoid coil
Solenoid Solenoid

17 O-ring AS568-012(Hs90) 4 4 4 Retainer A 14 Connector


5 Retainer B 15 Nameplate
18 O-ring 1A-P20 1 2 6 Retainer C 16 Screw
19 O-ring 1B-P18 2 2 7 Spacer 17 O-ring
8 Spring A 18 O-ring
20 O-ring S-25 1 2
9 Spring C 19 O-ring
Note) 1A and 1B are JIS Standard B 2401, while AS568 10 Nut 20 O-ring
is SAE standard.

Seal Kit Number


Single Solenoid Double Solenoid
EDCS-A EDCS-C

S-23
05S_Solenoid Valve(P13-24)_E.q 07.6.7 3:54 PM Page 24

Cross-sectional Drawing
SA-G03-A**-C*-(J)E21 SA-G03-C**-C*-(J)E21

20 15 21 14 16 17 19 2 20 15 21 14 16 17 19

8 10 11 9 7 5 3 18 1 6 4 8 10 11 9 7 4 3 18 1 6

SA-G03-A**-D/E*-(J)E21 SA-G03-C**-D/E*-(J)E21

20 15 21 14 16 17 19 2 20 15 21 14 16 17 19

8 10 13 12 11 9 7 5 3 18 1 6 4 8 10 13 12 11 9 7 4 3 18 1 6

List of Sealing Parts Part No. Part Name Part No. Part Name
1 Body 11 Solenoid coil
Part Type/Part Number Q'ty
Part Name 2 Plug 12 Coil case
No. AC SOL. DC SOL. Single Double
3 Spool 13 Coil yoke
Solenoid Solenoid

18 O-ring AS568-014(Hs90) 5 5 4 Retainer 14 Connector


5 Retainer B 15 Connector packing
19 O-ring 1B-P28 2 2
6 Spacer 16 Nameplate
20 O-ring 1A-P26 AS568-026 1 2 7 Spring 17 Screw
8 Nut 18 O-ring
21 O-ring AS568-029 1 2
9 Rod 19 O-ring
Note) O-ring 1A/B-** refers to JIS B2401-1A/B. 10 Solenoid guide 20 O-ring
21 O-ring
Seal Kit Number
AC SOL. DC SOL.

Single Solenoid Double Solenoid Single Solenoid Double Solenoid

ECBS-AA ECBS-CA ECBS-AD ECBS-CD

S-24
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 25

SE TYPE SOLENOID CONTROLLED


PILOT OPERATED DIRECTIONAL VALVE
SE Series (Pilot Operated G01: Direct type valve
G03: Pilot type valve ) 7.9 to 26.4gpm
Lower Power Solenoid Valve 1428 to 3000psi

Features
qLow current, low power wDirectly drivable by a pro- eLittle coil temperature rise
The SE series magnetic switching grammable controller Low power operation means there is little
valve’s solenoid has significantly lower Low-current operation means not only heat generated from the coil, which mini-
power consumption. allows direct drive by a programmable con- mizes the effects of heat on mechanisms.
troller (PC) output circuit, it also enables the Even with the AC solenoid, there is little
use of a compact and simple control circuit. chance of coil burnout.

¡Handling
Specifications zIn order to realize the full benefits of the
SE-G01-**-GR-**-30 SE-G03-**-GR-**-(J) 20 solenoid valve, configure piping so oil is
Operation Rated Flow Rate Maximum Rated Flow Rate Maximum
constantly supplied to the T(DR) port.
- Maximum Flow - Maximum Flow
Symbol JIS Symbol Rate Working Pressure JIS Symbol Rate Working Pressure xEnsure that surge pressure in excess of the
R/min(gpm) MPa{psi} R/min(gpm) MPa{psi}
maximum allowable back pressure can be
A B b AB
A2X
b 30 100 accidentally at the T port.
(7.9) 10 DR(T) (26.4) cNote that the maximum flow rate is limited
P T P
b A B
35 (1428) b A B
80 when used as a four-way valve, or by block-
A3X
P T
(9.2)
P T
(21.1) ing ports for use as a two-way valve or one-
AB a 100
way valve.
H2X
(26.4) vAlways keep the operating fluid clean.
P DR(T)
Allowable contamination is class NAS12 or
80
H3X less.
(21.1)
bWhen using petroleum type operating fluid,
b A B a 100 use JIS K 2213 Class 1 or Class 2, or
E3X
(26.4)
30 P T equivalent.
(7.9) A B
40 nBe sure to note the allowable pressure
b a 21
C4
10 P T
(10.6) (3000) range of the coil being used.
(1428)
b
A B
a
mMaintaining a switching position under high
C5 pressure for a long period can cause abnor-
40 P T
(10.6) A B mal operation due to hydraulic lockup.
b a
C6 100 Contact your agent when you need to main-
P T
tain a switching position for a long period.
A B
C6S b a ,When using a detent type (E3X), provide
P T constant energization when secure mainte-
A B
C7Y
b a 40 nance of the switching position is required.
P T
(10.6) .Note that manual pin operating pressure
b
A B
a 100 changes in accordance with tank line back
C1
P T
(26.4) pressure.
Note) The maximum flow rate of each valve depends on the pressure. For details, see page S-29.

¡Precautions During Use Example of Non-allowed Circuits


The SE Series is an internal pilot and internal drain type
valve, so the following precautions must be observed
whenever using it. b A B
1) A pressure of 0.4MPa {57psi} or greater is required at the
P T
P port for valve switching and holding.
2) For valve switching, a pressure of 0.4MPa {57psi} or
greater must be maintained between PT (DR) as minimum A B
b a
pilot pressure. In this case, make sure that P port pressure
is always greater than T (DR) port pressure. P T

3) Never close the T (DR) port. Be sure to run piping from it.
The following shows the required circuit configurations in this case.
4) A resistance valve is built in for flow paths C4 and C7Y, so
there is no need to provide an external check valve.
5) Generally, operating fluid flow in the following directions:
P/A, P/B, A/T, P/T. Do not configure for reverse
flow.
b A B b A B

P T P DR(T)

S-25
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 26

SE-G01-30 SE-G03-20

Solenoid Type DC Solenoid Internal DC solenoid for rectifier AC Solenoid DC Solenoid

D2 E1 E2 C1 C2 D1 D2

Maximum Working Pressure P, A, B Ports 10MPa {1428psi} 21MPa {3000psi}

Maximum Allowable 10MPa {1428psi} 7MPa {1000psi}


T port
Backpressure (In the case of 2MPa {300psi} operation symbol E3X) (In the case of 2MPa {300psi} operation symbol E3X)

Pilot Pressure (P-T Port Pressure) 0.4MPa{4kgf/cm2} minimum

Changeover Frequency (per minute) 120 120

Indicator light R
Standard GR GR
Surgeless

Double Solenoid 2.5 3.5


Weight (kg)
Single Solenoid 1.8 3.3

Dust Resistance/Water Resistance Rank JIS C0920 IP55 (Dust-tight, Rain-proof) JIS C0920 IP63 (Dust-tight, Rain-proof)

Ambient Temperature -20 to 50°C


Operating
Operating Fluid

Temperature Range -20 to 70°C


Environment
Viscosity Range 15 to 300mm2/s

Filtration 25 microns or less

M5 x 35 (Four)
Mounting bolt M5 x 30 (Four)
Bundled (M8 x 70 (Four))
Accessories M6 10 to 13N.m {102 to 133kgf.cm}
Tightening Torque 5 to 7N.m{51 to 71kgf.cm}
M8 20 to 25N.m {204 to 255kgf.cm}

Note) For mounting bolts, use 12T or equivalent.

Understanding Model Numbers


SE – G 03 – A 3 X – GR – C2 – J20
Design number
30: For 01 size
J20: 03 size for mounting bolt M6 (20 if mounting bolt is M8)

Power supply
C: AC (50/60Hz) C1=AC100V C2=AC200V (Applicable for size 03 only)
D: DC D1=DC12V D2=DC24V (D1 is applicable for size 03 only)
E: For AC (joint 50/60 Hz inside rectifier) E1=AC 100 V E2=200 V (applicable for size 01 only)

Auxiliary symbol
GR: Surgeless type with indicator (applicable for power supply C , D only)
R2: With indicator light (applicable for power supply E only)

X Y
Closed Semi-open

Center valve position flow path


1 3 4 5 6 7 6S
A B A B A B A B A B A B A B

P T P T P T P T P T P T P T

Operation Method
A H C E
Spring Offset Spring Center Detent
b A B A B a A B b A B a
b a
P T P T P T P T

Nominal pipe diameter


01 size
03 size

Mounting method
G: Gasket type

Low-power solenoid

S-26
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 27

¡Solenoid Assembly Specifications

Power For SE-G01 For SE-G03


Solen Voltage Frequency
oid Supply
Type Type (V) (Hz) Solenoid Holding Current Holding Power Allowable Voltage Solenoid Coil Drive Current Holding Current Holding Power Allowable Voltage
Coil Type (A) (W) Range (V) Type (A) (A) (W) Range (V)

50 0.29 0.19 6.1 80 to 110


AC100
EE64-
C1 60 0.24 0.135 4.1
01C1-1A
90 to 120
AC110 60 0.265 0.165 5.3
AC

50 0.145 0.095 6.1 160 to 220


AC200
EE64-
C2 60 0.12 0.07 4.1
01C2-1A
180 to 240
AC220 60 0.135 0.085 5.3

50 80 to 110
AC100 SLH1- 0.07 6.5
Built-in rectifier type AC

E1 60 025B-
R1-01 90 to 120
AC110 60 0.08 7.9

50 160 to 220
AC200 SLH1- 0.05 8.1
E2 60 025B-
R2-01 180 to 240
AC220 60 0.05 9.87

EE64-
D1 DC12 − 0.4 4.8 10.8 to 13.2
01D1-1A
DC

SLH1-
EE64-
D2 DC24 − 025B- 0.2 4.8 21.6 to 26.4 0.2 4.8 21.6 to 26.4
01D2-1A
D2-01

Installation Dimension Drawings


4- φ 5.5
DC Solenoid 4- φ 9
O-ring 4-JIS B2401-1BP9
SE-G01-A***-GR-**-30
31 8.5

31.75 8.5
15.5
5.1

0.75
25.9

48
12.7
21.5
30.2
12.5 40.5
88.2 68 13.5
Space required for solenoid removal 237.9
2-G1/2 169.7
5 93.7
91.9
73
25

22

SE-G01-C**-GR-**-30
SE-G01-E3X-GR-**-30
Space required for solenoid removal 380.8
244.4
5 93.7
22

Note) Gasket surface dimensions and the sub plate


are the same as those for SS-G01. See page S-5
for more information.

S-27
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 28

Installation Dimension Drawings Indicator light


AC Solenoid SOL b
P
SE-G03-A**-GR-C*-J20 A B
SE-G03-H**-GR-C*-J20
Note) T T
1. SE-G03-H**-GR-**-J20
The solenoid is on the opposite side of that shown
for SOLa in the illustrations shown here.
2. M8 mounting bolts Indicator light
Dimension 1 is 59. 2-G(PF)1/2 SOL a
Dimension 2 is φ 8.5.

SOL b

105
88
38

26.5
1)
2)
φ 6.5
70
96
Manual push-button 113.5 71
184.5

SE-G03-C**-GR-C*-J20 SOL b SOL a


SE-G03-E**-GR-C*-J20

113.5 113.5
30 227
Space required for coil removal

SOL b SOL a
DC Solenoid
SE-G03-A**-GR-D*-J20
SE-G03-H**-GR-D*-J20
SE-G03-C**-GR-D*-J20
SE-G03-E**-GR-D*-J20 118.5 71
189.5
35 237
Space required for coil removal

Note) Gasket surface dimensions and the sub plate are the same as those for SS-G03. See page S-6 for more information.
Wiring Diagram
SE-G01 SE-G03

Power supply SOL b Power supply SOL a


COM terminal hardware
M3 M3
Lamp SOL a

Lamp SOL b

SOL b SOL a SOL b SOL SOL SOL a

Ground terminal
Solderless terminal for M3.5

Ground terminal Short circuit equipment


M3 SOL b SOL a
Power supply remote control terminal M3 M3
M3

Note) 1.Wiring is simple for a double solenoid valve so 3.Use the ground terminal when grounding is
common terminal hardware is used. When the required.
common terminal hardware is not used, remove 4.The tightening torque of terminal screws is 0.5 to
the terminal screws. 0.7Nm {5.1 to 7.1kgf . cm}.
2.Use the ground terminal when grounding is required. 5.There is no wiring polarity for the DC solenoid.

S-28
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 29

Performance Curves Differential Hydraulic Fluid Viscosity 32mm2/s


Pressure Loss Characteristics
{kgf/cm2} Pump Type Flow Path P/A P/B A/T B/T P/T
1.25
e
A2X e e − − −

Pressure Loss
d
1 A3X e e d d −
c

MPa
E3X e e d d −
0.75 SE-G01
C4 a a a a a
C5 e e c c −
0.5
b C6 e e b b −
0.25
a

0 10 20 30 40
Flow rate r/min
2
{kgf/cm } Pump Type Flow Path P/A P/B A/T B/T P/T
2.0 20.4
f A2X, H2X b b − − −
e c
1.6 16.3 A3X, H3X b b c c −
b

Pressure Loss

C1 b b a b
1.2 a 12.2
SE-G03 C4 e e a a e
MPa

E3X, C5, C6S b b b b −


0.8 8.2
C6 b b a a −
C7Y f f d d e
0.4 4.1
d

0 20 40 60 80 100
Flow rate r/min

Pressure - Pump Type SE-G01 SE-G03


Flow Volume Operation
Example b A B A B A B A B A B A B
Allowable Value a b a b a b a b a b a
Operation P T P T P T P T P T P T
symbol
A2X − E A − K J
H2X − J K
A3X D C A J K J
H3X J J K
E3X B A A L L L
C1 J J J
C4 B B B M M M
C5 A B B J J J
C6 A B B J J J
C6S J J J
C7Y M M M

120
50
Flow rate

A 100 J
r/min

Flow rate

40
r/min

D
B 80 L
30
C E
60
20
40 M
10
20 K
0 2{20} 6{61} 10{102}
2 0 7{71} 14{143} 21{214}
Pressure MPa{kgf/cm }
Pressure MPa{kgf/cm2}

Note) 1.The maximum flow rate is the value when a rated 90%V is applied following solenoid temperature rise and saturation.
2.The maximum flow rate is the allowable value of each port.

S-29
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 30

Cross-sectional Drawing
SE-G03-A3X-GR-**-30

15 19 13 14

18 16 17 9 1 11 3 7 6 12 2

SE-G03-A3X-GR-**-20

15 19 13 14

Part No. Part Name


1 Body
2 Plug
3 Spool
4 Piston
5 Sleeve
6 Retainer
7 Stopper
8 Spring
9 Spring
10 Spring
11 O-ring
12 O-ring
13 Nameplate
14 Terminal box
15 Coil
16 Guide
17 Rod
18 Nut
19 O-ring
18 16 17 5 4 10 9 1 11 3 6 8 7 12 2

List of Sealing Parts


SE-G01 SE-G03
Part
Part Name Q'ty Q'ty
No. Part Number Part Number
Single Solenoid Double Solenoid Single Solenoid Double Solenoid

11 O-ring IB-P9 4 4 IB-P12 5 5


12 O-ring IB-P18 2 2 S25(Hs90) 2 2
19 O-ring S4 2 4 IA-P4 2 4

Note) O-ring 1A-** and 1-B** indicate JIS Standard B 2401-1A-** and 1B-**.

Seal Kit Number


SE-G01 SE-G03

Single Solenoid Double Solenoid Single Solenoid Double Solenoid

EECS-01A EECS-01C EES-03A-1A EES-03C-1A

S-30
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 38

DSS(DSA) TYPE SOLENOID CONTROLLED


PILOT OPERATED DIRECTIONAL VALVE
DSS (DSA) 22 Design Series 158.5gpm
Solenoid Control Valve 4571psi

Features
qLong-life operation is ensured by use wide-ranging low pressure loss and used for the internal pilot valve
of the high-performance, renowned enhanced system circuit efficiency. (option), pilot pressure required for
SS (SA)-G01 wet solenoid valve as rInternal modification of the pilot and switching is self-maintained.
the pilot valve. drain can be accomplished without
wHigh pressure, high capacity removing the valve by simply con-
The 06 size delivers up to 600 R/min. necting and disconnecting plugs.
eLow pressure loss tBuilt-in pilot pressure check valve
An original flow path design provides When tandem center type valve is

Specifications
Valve Size 06 Size

Valve Model Number DSS(DSA)-G06-***-R-**-E22

P.A.B. Ports 32{326} (4570)


Maximum Working
Pressure Internal Drain Type 16{163} (2286)
MPa{kgf/cm2} (psi) T Port
External Drain Type 21{214} (3000)

Maximum Flow Rate R/min (gpm) 600(158.3)

Rated Flow Rate R/min (gpm) 300(79.2)

Maximum Pilot Pressure MPa{kgf/cm } (psi) 2


25{255} (3571)

A** (Spring Offset Type)

E** (No-spring Detent Type) 0.8{8.2}(117.1)


Minimum pilot
pressure C** (Spring Center Type)
MPa{kgf/cm2}(psi)
D** (Pressure Center Type) 1.2{12.2}(174.3)

Built-in Pilot Pressure Check Valve Type (For Internal Pilot) 0.45 {4.6}(65.7) (for *3Z, *4, *7*, *8 pilot pressure generation)

Maximum Changeover Frequency (per minute) 120

A** (Spring Offset Type) 20.0(1.22)


Pilot Volume (cm3)(in3)
C** (Spring Center Type) 10.0(2.44)

A** (Spring Offset Type) 14.5(15.4)

E** (No-spring Detent Type)


Weight (kg) 15.0(15.9)
C** (Spring Center Type)

D** (Pressure Center Type) 16.5

Dust-resistance/Water-resistance Rank JIS C 0920 DSS: IP64 (Dust-tight, Splash-proof) DSA: IP65 (Dust-tight, Waterjet-proof)

Ambient Temperature -20 to 50°C


Operating
Temperature Range -20 to 70°C
Environment
Operating Fluid Viscosity Range 15 to 300mm2/s

Filtration 25 microns or less

Mounting bolt 1/2 × 2 1/2 (UNC)


Bundled
Tightening Torque
Accessories M12 60 to 70{612 to 714} (44–51)
N-m{kgf-cm} (Lbs.ft.)

Note) 1.The maximum flow rate of each valve depends on the pressure. For details, see pages S-42.
2.Weight in parentheses is for stroke adjustment type.
3.Solenoid specifications are the same as those for SS (SA)-G01. For more information, see pages S-3 and S-15.

S-38
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 39

¡Handling
zPilot pressure values show the differen- restrictor C7Y is standard. E3Z, C4, D4), PT mounting type (C7X,
tial pressure between the pilot port and vWhen adjustable spool stroke is desired, C7Y, D7X, D7Y), and PAT mounting type,
tank port or drain port. In the case of the specify L in the auxiliary symbol position use the type with built-in external pilot
pressure center, they show differential of the model number. Note, however, pressure check valve.
pressure between the pilot and drain that this is not available with the pressure ,The coil surface temperature increases if
ports (DR1, DR2). center type. this valve is kept continuously energized.
xThe standard configuration is internal bWhen using a detent type (E3*), use con- Install the valve so there is no chance of
pilot and external drain, but other config- stant energization in order to securely it being touched directly by hand.
urations are possible when required. See maintain the switching position.
page S-43 for more information. nUse of the pressure center type is recom-
cFor the PT mounting type DSS (DSA)- mended for large-volume flow control.
G**-C7*-**-22, open cross over with mFor the all ports open center type (A3Z,

Valve Model Number DSS(DSA)-G06

Front Position

A B
b a
Simplified Symbols

P T Y(DR1)

A' B'
b a
Detailed Symbols
P' T'
Y(DR1)
P T

AB

Flow Regulator Adjusting A Port Restrictor: Left side A


Screw Positions B Port Restrictor: Right side B

A Port Side: P/A, B/T flow rate adjustment


(For C7Y, P/B, A/T)
B Port Side: P/B, A/T flow rate adjustment
(For C7Y, P/A, B/T)

Adjustable Stroke
A port side B port side
Adjusting Screw Positions

S-39
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 40

Understanding Model Numbers


DSS – G 06 – C 7 Y C – – C2 – E22
Design number

Power supply
C: AC (50/60Hz) C1=AC100V C115=AC110V C2=AC200V C230=AC220V
D: DC D1=DC12V D2=DC24V
E: AC (Built-in rectifier; 50/60Hz)
E1=AC100V E115=AC115V E2=AC200V E230=AC230V
Auxiliary symbol (For multiple specifications, use alphabetic sequence.
A: Internal drain Y: With meter-out flow N: With manual lock
E: External pilot regulator valve G: Surgeless type
L: Spool stroke limiter R: With indicator light Q: Quick return type
P: Flow regulator valve DSS type: Standard
to restrict P port DSA type: Optional
Pilot pressure check valve
None: No check valve
C: Built-in check valve X Y Z
Closed Semi-open Open

Center valve position flow path


1, 2, 3, 4, 4S, 1 2 3 4 4S 5 6 6S 7 8
5, 6, 6S, 7, 8 A B A B A B A B A B A B A B A B A B A B

P T P T P T P T P T P T P T P T P T P T

Operation Method
A: Spring offset A E C D
E: No-spring detent Spring Offset No-spring detent Spring Center Pressure center
C: Spring center A B A B A B A B
D: Pressure center
P T Y(DR1) P T Y(DR1) P T Y(DR1) L(DR2) P T Y(DR1)

Nominal diameter 06 size


Mounting method G: Gasket type
Pump Type DSS: Central terminal box solenoid control valve
DSA: DIN connector type solenoid control valve

E NPT
E NPT

S-40
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 41

DSS(DSA)-G06-A**-R-**-E22
(Spring Offset Type)

L (DR2) port Y (DR1) port


Used for pressure center type Used for external drain

6- φ 21x2counterbore(Dia 0.83 x 0.08)


X (PP) port φ 13.8 holes(Dia 0.54)
Used for external pilot
AC150.5(5.93) Space required
DC157.5(6.20) 61(2.40) for coil removal
AC102(4.02) DSS type DSA type
48.5(1.91) DC109(4.29) 2-G1/2 (Previously PF)

SOL a

212.5(8.37)
207(8.15)
191.5(7.54)

201(7.91)
145.5(5.73)
48(1.89)
43(1.69)

120(4.72)
41(1.61)

(0.24)
50.5

6
(1.99) 127.5(5.02) 58(2.28) 2- φ 6(Dia 0.24)
255(10.04) 116(4.57)

E
DSS(DSA)-G06- **-R-**-E22 DSS(DSA)-G06-D**-R-**-E22
C
(No-spring Detent Type) (Pressure Center Type)
(Spring Center Type) AC204(8.03)
DC218(8.58)
AC102(4.02)
DC109(4.29) SOL b SOL a

SOL b SOL a

101.5(4.00)
178.5(7.03)
306(12.05)

A
A
E
DSS(DSA)-G06- **-RY-**-E22 DSS(DSA)-G06-E**-LR-**-E22
C
C
D
(Flow Regulator Type) (Adjustable Stroke Type)

SOL b SOL a
SOL b SOL a
Lock nut
252.5(9.94)
247(9.72)

Stroke adjusting screw


Pilot flow rate adjusting screw

Stroke adjustment range 12.5 96(3.78)


346(13.62)
(0.49)
417 max. (16.42)
Dimensions in the parentheses are for the DSA-G06-***-RY-**-21.

Gasket Surface Dimensions

( ISO 4401-08-07-0-94
JIS B 8355 D-08-07-0-94 ) For sub plate DSS (DSA) -G06
154(6.06)
130.2(5.12)
112.7(4.44)
100.8(3.97)
94.5(3.72)
77(3.03) 2- φ 7x8 (pin hole)
53.2(2.09)
(Dia 0.28 x 0.31)
12(0.47) 29.4(1.16)
4.7(0.19)

17.5(0.69)
12(0.47)

5.6(0.22)

T P
19(0.75)

Y
46(1.81)
74.6(2.94)
73(2.87)

(0.69)
118(4.65)

17.4
92(3.62)

L 2- φ 11 holes(Dia 0.43)
A B
X

32(1.26) 25.3
(1.00) 6- UNC 1/2"
35(1.38) φ 11 hole(Dia 0.43) 180.8(7.12)
207(8.15)

4- φ 20 holes(Dia 0.79)

S-41
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 42

DSS(DSA)-G06
Model No. JIS Symbol Pressure - Flow Rate Allowable Value Model No. JIS Symbol Pressure - Flow Rate Allowable Value

DSS(DSA) 1 1 DSS(DSA) 1 1
A B A B
2-Position Spring Offset Type

2-Position Spring Offset Type


a b a
-G06 -G06
P T Y(DR1) P T Y(DR1)
-A3X- 2 1 600 -E3X- 2 1 600

Flow rate

Flow rate
500 500

/min

/min
1 1 400 1 1 400
A B
A B
a 300 b a 300
-A3Z- -E3Z-
200 P T Y(DR1)
200
P T Y(DR1)
2 1 100 2 1 100

1 1
0 10{102} 20{204} 30{306} 1 1
0 10{102} 20{204} 30{306}
A B
a Pressure MPa{kgf/cm2} b A B
a Pressure MPa{kgf/cm2}
-A3Y- -E3Y-
P T Y(DR1) P T Y(DR1)
2 1 2 1

DSS(DSA) 1 1 DSS(DSA) 1 1
A B A B
b a b a
-G06 -G06
P T Y(DR1) L(DR2) P T Y(DR1)
-C1- 2 1 -D1- 2 1
PP-0.8MPa{8.2kgf/cm2}
1 1 1 1
A B A B
b a b a
-C2- -D2-
P T Y(DR1) L(DR2) P T Y(DR1)
2 1 2 1
PP-1.2MPa{12.2kgf/cm2}
1 1 1 1
A B A B
b a b a
-C5- 600 -D5-
Flow rate

P T Y(DR1) L(DR2) P T Y(DR1)


500
/min

2 1 2 1
400
300 1 1
3-Position Spring Center Type

3-Position Spring Center Type


200 b A B
a
-C6- 100 -D6-
L(DR2) P T Y(DR1)
0 10{102} 20{204} 30{306} 2 1 600

Flow rate
Pressure MPa{kgf/cm2} 500

/min
1 1 1 1 400
A B A B
b a b a 300
-C6S- -D6S-
P T Y(DR1) L(DR2) P T Y(DR1)
200
2 1 2 1 100

1 1 1 1 0 10{102} 20{204} 30{306}


b A B
a 600 b A B
a Pressure MPa{kgf/cm2}
Flow rate

-C4S- 500 -D4S-


/min

P T Y(DR1) 400 L(DR2) P T Y(DR1)


2 1 2 1
300
1 1 200 1 1
b A B
a 100 b A B
a
-C4- -D4-
P T Y(DR1)
0 10{102} 20{204} 30{306} L(DR2) P T Y(DR1)
2 3 1 Pressure MPa{kgf/cm2} 2 3 1

1 1 1 1
b A B
a 600 b A B
a
Flow rate

-C8- 500 -D8-


/min

P T Y(DR1) 400 L(DR2) P T Y(DR1)


2 5 1 2 5 1
300
3 2
200 3 2
-C7X- b A B
a
100 -D7X- b A B
a

-C7Y- P T Y(DR1)
0 10{102} 20{204} 30{306} -D7Y- L(DR2) P T Y(DR1)
2 5 4 Pressure MPa{kgf/cm2} 2 5 4

Pressure Loss Characteristics Note) Switching Response Time


Interpreting the Pressure Loss Value Model No. : DSS-G06-C5
5 4 1 1 Voltage Symbol: C1 (AC Solenoid)
A B
3 b a
2.0{20.4}
P T Y
2
Pressure Loss
MPa{kgf/cm2}

1.6{16.3} 2 4 1 (DR1) 0.15


At switching

1
1.2{12.2} SOL, OFF
sec

0.10
0.8{8.2} P A Curve 1
SOL, ON
Curve 2 0.05
B T
0.4{4.1}
At center
P T Curve 4 0 5{51} 10{102} 15{153} 20{204} 25{255}
0 100 200 300 400 500 600
Pilot pressure MPa{kgf/cm2}
Flow rate /min

S-42
05S_Solenoid Valve(P25-43)_E.q 07.6.7 4:00 PM Page 43

Cross-sectional Drawing
DSS(DSA)-G06-C**-R-C*-E22

18 17 6

Pilot, Drain System Change

9 A 16 8 B

P
T
R C
P

R 10

X(PP)

15
Y(DR1)
P
7 Cross-sectional P-P Cross-sectional R-R

4 1 3 13 11 14 12 5 2

Changing the Pilot and Drain Connections


Part No. Part Name Part No. Part Name Part No. Part Name After Change Hexagon Socket Head Plug
1 Body 8 Plug 14 O-ring
Internal Remove from A.
2 Cover 9 Plug 15 O-ring Pilot
3 Spool 10 Plug 16 O-ring External Insert into A
4 Ring 11 Pin 17 Solenoid Valves
5 Spring 12 O-ring 18 Screw Internal Switch from B to C.
Drain
6 Nameplate 13 O-ring External Switch from C to B.
7 Screw
Note) A single hex head plug (NPTF 1/16) is required
when changing to external pilot.

List of Sealing Parts Seal Kit Number


Part Number 06 Size
Part No. Part Name Q'ty
06 Size Single Solenoid Double Solenoid
12 O-ring 1B-G45 2 EDBS-06AA-1A EDBS-06CA-1A
13 O-ring 1B-P28 4 Note) The seal kit includes a seal for the pilot sole-
noid valve.
14 O-ring 1B-P20 2
15 O-ring 1B-P10 2
16 O-ring 1B-P8 3

Note) 1.O-ring 1A/1B/4D-** indicate JIS Standard B 2401-1A/1B/4D-**.


2.See SS/SA-G01-**-31for information about the seal part for the pilot sole-
noid valve.

S-43
05S_Solenoid Valve(P44-48)_E.q 07.6.7 3:59 PM Page 44

FINE SOLENOID VALVE

Fine Solenoid Valve 2.6 to 10.6gpm


SF Series 3000psi

Features
qThe function of two valves in one eSeparate control of forward and back ¡Handling
A two-speed controller provides smooth cylinder movement zValve differential pressure
speed adjustment from low speed to high, There are five volume settings for high- Volume adjustment becomes sensitive
and from high-speed to low. speed flow rate and acceleration/deceler- when P→A (B) and B(A)→T differential
wQuiet starts and stops ation times that can be independently pressure is large. Maintain the pressure dif-
ferential so it is no greater than 3.5MPa
A low-speed startup and stop feature adjusted SOL.a and SOL.b (ON side,
{35.7kgf/cm2}.
makes startups and stops smooth and OFF side).
xLow-speed flow rate
soft. The spool may not move if the low-speed
Specifications flow rate is below the minimum. Use this
valve only within the allowable minimum
Model No. SF-G01 SF-G01 SF-G01 low-speed flow rate range.
Item -C*10-D2-E10 -C*20-D2-E10 -C*40-D2-E10 cDeceleration circuit
Valve Maximum Operating Pressure MPa(psi) 21(3000) ¡Use a C5** spool for the deceleration
Maximum Flow Rate R/min(Note1)(gpm) 10(2.6) 20(5.3) 40(10.6) circuit. Deceleration is difficult with the
High-speed Flow Rate R/min(Note1)(gpm) 5 to 10(1.3 to 2.6) 10 to 20(2.6 to 5.3) 20 to 40(5.3 to 10.6)
C6S** spool.
Low-speed Flow Rate R/min(Note1)(gpm) 0.5 to 4(0.1 to 1.0) 2 to 8(0.5 to 2.1) 4 to 16(1.0 to 4.2)
¡When large deceleration is required or
Maximum Allowable Pressure MPa(psi) 7(1000)
for a system that uses a vertical cylin-
Acceleration/Deceleration Time Adjustment Range SEC 0.1 to 2
der, equip an external drain type
Hysteresis (Note 2) 7%
counter balance valve. See the illustra-
Repeatability (Note 2) 3%
Power Supply Voltage V D2: 24V DC regulated DC power supply
tion below.
Maximum Power Consumption W 36W vPilot check circuit
Dust Resistance/Water Resistance Rank JIS C0920 IP63 (Dust-tight, Rain-proof) ¡For a circuit with a pilot check valve,
Environment

knocking may occur in the pilot check


Operating

Ambient Temperature 5 to 50°C


Temperature Range 5 to 60°C valve due to large load inertia and circuit
Operating
Viscosity Range 15 to 300mm2/s pressure loss. In cases like this, use an
Fluid
Filtration 25 microns or less external drain type pilot check valve. See
Size x Length 10–24 x 1 3/4 the illustration below.
Mounting
bolt

Tightening Torque 5 to 7N-m{51 to 71kgf-cm} 3.6–5.1Lbs.ft.

Note) 1.The above high-speed and low-speed flow rates are obtained with a differential pressure
(PA, PB) of 1.0MPa {146psi}. The flow rates depend on differential pressure.
2.Hysteresis and repeatability values are those at maximum flow rate. DR

3.For mounting bolts, use 12T or equivalent.


DR
4.Mounting bolts are not included. b A B a b A B a

P T P T

When large brake pres- When there is the possibil-


Understanding Model Numbers sure is required
(Use an external drain
ity of pilot check valve
knocking
type counter valve.) (Use an external drain
SF – G01 – C – R – D2 – E10 type pilot check valve.)
bEnvironmental conditions
Design number
E5153A-3 turn potentiometer ¡The IC circuit board is located inside the
Power supply D2: 24V DC central control box, so care must be
exercised concerning water-resistance
With indicator light and ambient temperature.
Auxiliary symbol • Water: Cover the box so there is no
None: Sink direct splashing with water.
A: Source • Ambient Temperature: Use in an area

Maximum flow rate: 10, 20, 40 /min


where the temperature is 5°C to 50°C.
nOperating Fluid
Center position: 5,6S ¡Always keep the operating fluid clean.
Operation Method: C (Spring center) Allowable contamination is class NAS11
or less.
Mounting method G: Gasket type ¡Use oil-based hydraulic operating fluid.
Nominal diameter: 01 (01 size)
¡Contact your agent when you want to
Fine solenoid valve use fire-resistant hydraulic fluid.
(Continued on following page)

S-44
05S_Solenoid Valve(P44-48)_E.q 07.6.7 3:59 PM Page 45

mNote the following points to optimize opera- (2)During the positioning operation following deceleration before stopping operation. If
tion. deceleration, make sure that sufficient low-speed operation time is too short can
(1)Control fluid temperature when using this low-speed running is provided following cause stopping during deceleration and
valve. Since the valve perform restrictor shock problems due to fluctuation in load,
valve control on all processes, tempera- Spool Type and JIS Symbols etc.
ture differential changes flow volume and
Spool Type C5** C6S**
acceleration/deceleration time. The rec-
ommended temperature range is 30°C to b A B a b A B a
60°C. JIS Symbol
P T P T

Electrical Wiring
¡Sink Type (Auxiliary Symbol: None) ¡Source Type (Auxiliary Symbol: A)
Switches on load and power supply minus Switches on load and power supply plus
side side

COM terminal (+) SW1 Low-speed signal input terminal

Low-speed High-speed Low-speed

Switch SW2 ON
+ 24V DC regulated +
24V DC regulated High-speed
DC power supply – DC power supply signal

Switch SW1 ON
Low-speed
signal
High-speed signal High-speed signal Time
SW2 input terminal SW2 input terminal
Low-speed signal
SW1 input terminal COM terminal (–)

Electrical Control Precautions


¡Do not introduce a high-speed signal
Adjustment Elements prior to a low-speed signal. Make sure
Control Pattern the two signals are introduced simultane-
ously or that the low-speed signal is intro-
Acceleration time High-speed flow rate Decreation time
adjustment VR2 adjustment VR3 adjustment VR4 duced first.
(1)Repeatedly introducing the high-speed
signal first in a source type configuration
Flow rate

ON side OFF side can damage the IC board.


Low-speed flow rate Low-speed flow rate (2)The valve will not operate on the high-
adjustment VR1 adjustment VR5
speed signal only.
¡The following adjustments in the range of
VR1 through VR5 can be made indepen-
0 dently for SOL.a and SOL.b. You can
High-speed

make adjustments for the best conditions


SW 2 ON
for forward and back operations when
signal

considering the cylinder operations.


¡Adjustment volume is arranged in from
Low-speed

SW 1 ON VR1 through VR5 in clockwise (right-


signal

ward) rotation sequence when viewed


from the coil side.
Time ¡The following are the factory default vol-
ume settings.
VR1 . 2 . 4 . 5
⎯⎯ Minimum setting

(SOL b) Acceleration time adjustment VR2


(SOL a) High-speed flow rate adjustment VR3 ⎯⎯ Maximum setting
(SOL a) Deceleration time adjustment All Adjustment VRs
(SOL b) ON side low-speed flow rate adjustment VR1
(SOL a) OFF side low-speed flow rate adjustment
Maximum is clock-
wise (rightward)
SOL b SOL a rotation.
(Max.)

¡The volume rotation


(SOL b) OFF side low-speed flow rate adjustment
(SOL a) ON side low-speed flow rate adjustment angle is 270°. Contact
(SOL b) Deceleration time adjustment
(SOL b) High-speed flow rate adjustment
(SOL a) Acceleration time adjustment your agent about a
three-rotation type adjus-
tor for fine adjustment.

S-45
05S_Solenoid Valve(P44-48)_E.q 07.6.7 3:59 PM Page 46

Installation Dimension Drawings


Indicator light (SOL-b)

31(1.22) 0.75(0.03)
SF-G01-C***-(A)R-D2-E10

15.5(0.61)
5.1(0.20)
T

32.5(1.28)
25.9(1.02)
B
A

12.7(0.50) Indicator light (SOL-a)


21.5(0.85)
30.2(1.19)
40.5(1.59)

2 to G (Previously PF) 1/2


112.5(4.43) 137(5.39)
92.5(3.64)
48(1.89)

37.5(1.48)
SOL b SOL a
25.5(1.00)

φ 5.5(Dia 0.22)
46(1.81) 66(2.60)
216(8.50)

Performance Curves Hydraulic Operating Fluid Viscosity 32mm2/s


¡Pressure − Flow Rate Characteristics
• Use the valve within the allowable flow
rate range shown by the graph to the
right.
40
• There are no operational problems with-
C540 in the allowable flow rate range, even
C6S40 when one-pass is used.
30
Flow rate
/min

20

C520
C6S20
10

C510
C6S10
0 10{102} 20{204}
Pressure MPa{kgf/cm2}

¡Control Waveform Example


• Valve: SF-G01-C510-R-D2-E10
Control flow rate 10 /min • Supply Pressure: 21MPa{214kgf/cm2}
• Hydraulic Circuit
Control flow rate Control flow rate
0.5 /min 0.5 /min
0
Timer set Timer set
Max SW 2 ON Max
b A B a
OFF
SW 1 ON
P T

OFF

0.00 Time 20.00s

S-46
05S_Solenoid Valve(P44-48)_E.q 07.6.7 3:59 PM Page 47

Cross-sectional Drawing
SF-G01-C***-(A)R-D2-E10

19 18 10 13 14 8 9 17 12 11 7

Part No. Part Name


1 Body
2 Cover
20 15 2 6 4 3 1 5 16 3 Spool
4 Retainer
5 Spacer
6 Spring
Seal Part List (Kit Model Number EFS) 7 Nut
8 Solenoid guide
Part No. Part Name Type/Part Number Q'ty 9 Solenoid coil
16 O-ring AS568-012(Hs90) 4 10 Packing B
11 Coil case
17 O-ring AS568-019 4
12 Coil yoke
18 O-ring AS568-019(Hs90) 2 13 Central terminal box kit
19 O-ring AS568-017(Hs90) 2 14 Nameplate
15 Hexagon Socket Head Bolt
20 O-ring P3 Note2 2
16 O-ring
Note) 1.O-ring 1B-** refers to JIS B 2401-1B-**. 17 O-ring
2.Special flurorubber is used (Part Number: RO-P3-VS). 18 O-ring
19 O-ring
20 O-ring

S-47
SAW/DSW Series
Solenoid Valve with Monitoring Switch
For Press Safety Confirming Systems
SAW/DSW Series
Solenoid Valve with Monitoring Switch For Press Safety Confirming Systems
Safety is critical in the manufacturing industry. Today, most manufac-
turers rely on a conventional system that detects danger and stops a
machine during operation. In Japan, however, the trend is to utilize a
Safety Monitoring System to monitor safety and allow a machine to
operate after safety is confirmed. As new global safety standards are
established, it is predicted that these Safety Monitoring Systems will
be included in machine specifications at the design stage. Our
Solenoid Valve with Monitoring Switch, Japan’s first Safety
Monitoring System, is specially designed to meet the requirements
of machine integration and safety.

ISO 12100 will change the industry’s perception of mechanical hazard protection.
In the future, machines will require safety standards compliant with ISO 12100.

Hazard Detecting Type System Safety Confirming Type System


(Conventional) (Intrinsic Safety Design)
Distribute Distribute
Detect Detect
Information Information
HAZARD STOP SAFETY ALLOW
with Operation with Operation
Machinery Machinery

When hazard is detected, machine operation When safety is detected, machine operation
is not allowed and stopped. is allowed.
(Accidents cannot be avoided due to machine not (Accidents can be avoided due to machine not being
stopping, even after danger occurs when sensor allowed to operate when sensor breaks down or sig-
breaks down or signal wire is disconnected.) nal wire is disconnected.)

Features
This valve mechanically detects the movement of the solenoid valve spool to
activate the switch and to transmit an electrical ON/OFF signal. In other words,
this valve monitors a spool operating condition and can be used for sequence
control according to its ON/OFF signal. It is also an information source for
confirming safety conditions.

Fig.1 and 2 show the simplified actuation structure of a solenoid valve with Fig.1 Solenoid not energized
monitoring switch. When the spool is in center position, the fixed contact (Switch ON)
(blue) contacts the traveling contact (red) and the both contacts become in
conducting condition (Switch ON). When the solenoid is energized and the
spool moves right, the traveling contact (red) detaches from the fixed contact
(blue) in conjunction with the spool movement and both contacts become in
non-conducting condition (Switch OFF).

Fig.2 Solenoid energized


(Switch OFF)
Example of Use

Hyd. Cylinder
Assuming that valve does not return
to neutral position (all ports blocked)
due to some kind of trouble even
Solenoid Valve after solenoid is turned off.
Monitoring Switch
Switch ON at neutral
position (confirming Safety Confirming Type System
safe condition)
• Cylinder continues moving.
• Safety cannot be confirmed because
signal of monitoring switch is not
turned ON.
Hyd. Pump
• Possible to ensure safety by prevent-
ing safety cover from opening and
detecting some kind of error.

Specifications
Series SAW-G01 SAW-G03 (Note 1) DSW-G04 (Note 1)
Operation Type Direct operated type spool valve Pilot operated type spool valve
Max. Working Pressure (Note 2) 35MPa (5,076psi)
Max. Flow Rate (Note 3) 100L/min (26.4gpm) 160L/min (42.2gpm) 300L/min(79.2 gpm)
Max. Allowable Back-Pressure 21MPa (3,046psi) 16MPa (2,320psi) 21MPa (3,046psi)
Dust Resistance/
Water Resistance Rank JIS C 0920 IP65
Environment
Operating

Operating Fluid (Note 4) Petroleum type


Ambient Temperature -20 to 50º C (-4 to 122 ºF)
Temperature Range -20 to 70º C (-4 to 158 ºF)
Viscosity Range 15 - 300 mm2/s
Filtration 25µm or less
Rated Voltage DC24V
Monitoring

Allowable Voltage Range DC24V±20%


Switch

Max. Load Current 100mA


Residual Voltage (Note 6) Max. 1.2V
Wiring to Connector Lead wire or M12-4 pins connector

(Note 1) SAW-G03 and DSW-G04 will be launched in the middle of 2006.


(Note 2) The maximum working pressure is dependent on the valve type.
(Note 3) The maximum flow rate is dependent on the valve type and the working pressure.
(Note 4) Use petroleum type operating fluid only. The fluid requires insulation performance for configuration of the monitoring switch being oper-
ated in the fluid. Fluids other than petroleum type (e.g. water-glycol, water in oil emulsion type, phosphate ester, fatty acid ester) are not accept-
able. Even petroleum type must not exceed 0.1% of water content.
(Note 5) Plus (+) common method and minus (-) common method are available for programmable controller input circuit. Solenoid valve with mon-
itoring switch employs source method (switch on at load and plus (+) side of the power supply) for safety of electric circuit. Consequently, when
inputting a monitoring switch output into a programmable controller, use a minus (-) common type programmable controller.
(Note 6) Supply voltage to the monitoring switch shall be given within a range fulfilling the following condition. Load ON voltage + Residual volt-
age ≤ Switch supply voltage ≤ 28.8 V (Rated voltage + 20%).
Dimensional Drawings

SAW-G01 series SAW-G03 series


The installation dimension on the gasket The installation dimension on the gasket
surface is the same as ISO 4401-03-02. surface is the same as ISO 4401-05-04.

T P

A B
A
B
T T
P
110.5(4.350)

125.5(4.941)
92.5(3.642)

112(4.409)
70(2.756) 93(3.661)
46(1.811) 66(2.598) 135.5(5.335) 94.5(3.720)
119.5(4.705) 70.5(2.776) 230(9.055)
190(7.480)

169.5(6.673) 169.5(6.673)
339(13.346)
140.5(5.531) 140.5(5.531)
281(11.063)

(Note 1) Dimension is for DC solenoid.


(Note 2) The connector for switch in the above is with M12-4 pin connector. Also available with lead wire.
(Note 3) The connector wiring port should be pointed in the direction shown in the above on the ground of packing when shipping. Change the
direction as needed when wiring.

NACHI AMERICA INC.


17500 23 Mile Road, Macomb, MI 48044
Tel. (800)622-4410 Fax. (586)226-5289
04D_DMA Series(P01-02)_E.q 07.6.7 4:47 PM Page 2

BALANCED PISTON TYPE


RELIEF VALVE

r/min
20 to 380r
DMA Type Manually Operated Directional Valve
21MPa

Features
qCompact design. eD03 and D05 mounting pattern
wBalanced design allows T-port back alows the use of modular valves to
pressure up to 70 kgf/cm 2 (1000 simplify circuit design.
psi) in G03 and 160 kgf/cm2 (2286
psi) in G01 models.

Specifications

350, 250 (3571), Note 160 (2286) 40 (10.6) 4 (0.16) 4 (0.16) x 2 1.3 (2.9)

250 (3571) 70 (1000) 75 (19.8) 6 (0.24) 4 (0.24) x 2 3.0 (6.6)

Note: The figure in parenthesis is for tandem center type.

¡Notes
zThe following three different methods are available
to operate the valve handle.
20
10 (1) Spring offset type(A-type)
20 With this type, the lever is always kept at the end
10
20 position; when the lever is pulled, the flow is
10
20
changed over from one direction to another. But
10 when the lever is released, the flow returns to the
20 initial direction.
10 (2) Spring center type(C-type)
With this type, the spool is always kept at the center
20 between the other two valve positions; when the
10
lever is released after shifting the spool to either
one of these valve positions, the spool returns to
20
10 the center with the assistance of the spring.
(3) Detent type (F- and E-types)
20 With this type, the spool comes to a standstill by its
10 notch provided at the third or second position on
this spool.
20 xThe mounting direction of the lever can be
10
changed optionally at every 90° if the direction
20
of the cover on the lever side is changed.
10 cDMA-G**-*7*-10 of the P and T port connection
20
type is based on DMA-G**-*7X-10 of the closed
10 cross type.
20
10 vThe following are the locking bolts furnished for
20 each valve.
10
20
10

20
10 Note: Use the locking bolts with a torque rating
of grade 12.9 or the equivalent.

20 bSelect the desired subplate according to the fol-


10
lowing table if necessary.

D-1
04D_DMA Series(P01-02)_E.q 07.6.7 4:47 PM Page 3

Understanding Model Numbers


DMA – G 01 – A 3 X – E 20
E20: G01
Design Code E10: G03 X: Closed Crossover
Y: Open Crossover with Taper
Flow Condition at Crossover Z: Open Crossover
Valve Spool Type 3, 4, 5, 6, 7, 8
Spring ArrangementA: Spring Offset
C: Spring Center
Valve Size E, F: Detent
Mounting G: Gasket Mounting
Manual Valve (DMA Type)

Installation Dimensions
DMA-G01-***-E20 DMA-G03-***-E10

Cross-Sectional Drawings
DMA-G01-***-E20 Part name Part name

Part name Part number

RO-P12-90

Seal Kit = DNS-G01 (DMA-G01)


Seal Kit = DNS-G03 (DMA-G03)

D-2