Professional Documents
Culture Documents
Sy104230 CT 01
Sy104230 CT 01
Sy104230 CT 01
(if applicable)
RJ45
To Next VFN or IOBGP (if applicable)
RJ45
To Current Shunt
Common
XH8 YH12
LVDPower Battery
S1
YH11 XH6 XH7 Midpoint YH3
SC200 Current Monitoring
RXP Temp DCD
Controller XH4
RJ45 S3 LVD1
S2
XH9
VFN-00 IOBGP-00 (01) Bus Voltage
TB1 XH5
Serial LVD2
RS232
P1 RY1 RY2 RY3 RY4 RY5 RY6 Digital Inputs 1-3 Digital Inputs 4-6
XH16 XH17 XH18 XH19 XH20 XH21 XH15A XH15B
2 Core
COM
NO
NC
Ethernet
0V
DI
Live P2
TCP/IP USB
RJ45
RJ45 RJ45 RJ45 To Next Cabinet
RJ45
To Current Shunt (if fitted)
RJ45
1 Core per Battery To Battery Mid Point (if fitted)
BL/6
COMMON BUS RJ45
To FFN (Load/Battery Distribution – if fitted)
Common
XH8 YH12
LVDPower Battery
S1
YH11 XH6 XH7 Midpoint YH3
RXP Current Temp Monitoring DCD
XH4
RJ45 S3 LVD1
From Previous VFN S2
XH9
TB1 XH5
LVD2
P1 RY1 RY2 RY3 RY4 RY5 RY6 Digital Inputs 1-3 Digital Inputs 4-6
XH16 XH17 XH18 XH19 XH20 XH21 XH15A XH15B
2 Core
COM
NO
NC
0V
DI
Live P2
Flexenclosure
Slave RXP Communications SY104230-CT-01 (Page 2 of 6)
3P 63A
Chint NB1 NPR48-ES Rectifier Magazine - 1
C Type
L1 BN/10mm2 Rectifiers 1 to 2
3P 63A
Chint NB1 NPR48-ES Rectifier Magazine - 2
C Type
L1 BN/10mm2 Rectifiers 1 to 2
To Rectifier Magazine 1
3P 63A
Chint NB1 NPR48-ES Rectifier Magazine - 3
C Type
To Rectifier Magazine 2
L1 BN/10mm2 Rectifiers 1 to 3
To Rectifier Magazine 4
3P 63A
Chint NB1 NPR48-ES Rectifier Magazine - 4
C Type
L1 BN/10mm2 Rectifiers 1 to 2
CAT5
Common
COM
COMMON BUS BAR BUS
S1
CAT5 S3 S2
CAT5
4 x 240mm2 Cables Per Output VFN-00
XH8 TB1
YH12
LVD Battery
Power YH11 XH6 XH7 YH3 P1
Midpoint DCD LIVE
RXP Current Temp
XH4 Monitoring BUS CAT5
Live P2
LVD1 XH9
Bus
XH5
IOBGP-00
Voltage 2 Core
LVD2
COM
TPS00 TPS00 TPS00 TPS00 TPS00 TPS00 TPS00 TPS00
NO
NC
0V
DI
Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse S1
600A 600A 600A 600A 600A 600A 600A 600A
CAT5 S3 S2
CAT5
VFN-00
XU1 XU1 XU1 XU1 XU1 XU1 XU1 XU1 XH8 TB1
YH12
XU2 XU2 XU2 XU2 XU2 XU2 XU2 XU2
LVD Battery
Power YH11 XH6 XH7 YH3 P1
Midpoint
RXP Current Temp DCD
XH4 Monitoring
Live P2 CAT5
LVD1 XH9
IOBGP-00 Bus
XH5 Voltage
LIVE BUS BAR LVD2
COM
NO
NC
0V
DI
BUS
S1
S3 S2
CAT5
CAT5
CAT5 VFN-00
TB1 CAT5
S2
S1
2 Core
NO
NC
0V
DI
ISSUE AMENDMENT DRAWN APPV'D
01 First Issue AMc Power Application Group
240kW / -48VDC Power System
Flexenclosure
SY104230-CT-01 (Page 4 of 6)
Load Fuse Fail Circuit
Battery Fuse Distribution
RXP BUS
CAT5
Common
TB1
XU1 XU1 XU1 XU1 XU1 XH8 YH12
LVD P1
XU2 XU2 XU2 XU2 XU2 Battery YH3
Power YH11 XH6 XH7
Midpoint
RXP Current Temp DCD Live P2
XH4 Monitoring CAT5
LVD1 XH9
Bus
XH5
IOBGP-00
Voltage
LIVE BUS BAR LVD2
COM
NO
NC
0V
DI
BUS
S1
To Bus Bars
S3 S2
CAT5
CAT5
CAT5 VFN-00
TB1 CAT5
Power XH8 YH12 P1
LVD Battery LIVE
XH6 XH7 YH3
BFN-00 Fuse Power YH11
Current Temp
Midpoint
DCD
BUS
Live P2
RXP Monitoring
Input XH4
LVD1 XH9
Bus RXP BUS
XH5
IOBGP-00
Voltage
LVD2
2 Core
6 x Digital Outputs 6 x Digital Inputs
COM
2 Core
NO
NC
0V
DI
ISSUE AMENDMENT DRAWN APPV'D
01 First Issue AMc Power Application Group
240kW / -48VDC Power System
Flexenclosure
SY104230-CT-01 (Page 5 of 6)
Battery Fuse Fail Circuit
SY104230 SY104232 SY104231 SY104233
Master Rectifier Slave Rectifier Slave Rectifier Slave Rectifier
Load Distribution Cabinet Battery Distribution Cabinet Load Distribution Cabinet Battery Distribution Cabinet
SC200
V F N RM 01 RM 02 RM 03 RM 04 RM 05 RM 06 RM 07 RM 08 RM 09 RM 10 RM 11 RM 12 RM 13
V F N V F N V F N V F N V F N V F N V F N V F N V F N V F N
IOBGP 01 IOBGP 02 IOBGP 03 IOBGP 04 IOBGP 05 IOBGP 06 IOBGP 07 IOBGP 08 IOBGP 09 IOBGP 10
Load Current Load Current Load Current Batt Current Batt Current Load Current Load Current Load Current Batt Current Batt Current
01 to 03 04 to 06 07 to 08 01 to 03 04 to 05 09 to 11 14 to 16 17 to 18 06 to 08 09 to 10