Professional Documents
Culture Documents
Formation SAN CCK
Formation SAN CCK
Formation SAN CCK
Manufacturer: Emulex
Model: LPe12002-S
Type: L-port
State: online
Manufacturer: Emulex
Model: LPe12002-S
Type: L-port
State: online
Manufacturer: Emulex
Model: LPe12002-S
Type: N-port
State: online
Manufacturer: Emulex
Model: LPe12002-S
Type: N-port
State: online
root@wouri1 #
Brocade SAN switch zoning with CLI command
1. Zone name server check
nsshow
2. Disable name server check
defzone --show
defzone --noaccess
defzone --show
3. Create Alias
alicreate “Windows_port0”, “10:00:00:00:xx:xx:xx:xx”
alicreate “Linux_port0” , “ 10:00:00:00:xx:xx:xx”
alicreate “VNX_SPA3” , “ 50:06:01:63:47:xx:xx:xx”
4. Create zone
zonecreate “WIN_P0_VNX_SPA3” , “Windows_port0;VNX_SPA3”
zonecreate “Linux_P0_VNX_SPA3” , “Linux_port0;VNX_SPA3”
5. Create zone configuration
cfgcreate “zoneconfig1” , “WIN_P0_VNX_SPA3; Linux_P0_VNX_SPA3”
6. Save the zone configuration
cfgsave
7. Zone enable
cfgenable zoneconfig1
Cfgshow
NB : zone disable= cfgdisable
Zone clear= cfgclear
Concepts of FC fabrics
Concepts of IP SANs
Network interfaces in hosts in IP SANs
Converged networks
telnet 0 1101
^down: standby
(l): loopback
(s): spoofing
10GE2/2/1 up up
10GE2/3/1 up up
10GE2/4/1 up up
10GE2/7/1 up up
10GE2/8/1 up up
10GE2/9/1 up up
10GE2/11/1 up up
10GE2/15/1 up up
10GE2/16/1 up up
10GE2/17/15 up up
10GE3/2/1 up up
10GE3/3/1 up up
10GE3/3/2 down down
10GE3/4/1 up up
10GE3/7/1 up up
10GE3/8/1 up up
10GE3/9/1 up up
10GE3/11/1 up up
10GE3/15/1 up up
10GE3/17/15 up up
40GE2/18/1 up up
40GE2/18/2 up up
40GE3/18/1 up up
40GE3/18/2 up up
MEth0/0/0 up up
NULL0 up up(s)
Stack-Port2/1 up up
Stack-Port3/1 up up
Vlanif19 up up
Vlanif57 up up
Vlanif59 up up
Vlanif813 up down
[~CX912]
[~CX912]display vlan
The total number of vlans is : 11
--------------------------------------------------------------------------------
#: ProtocolTransparent-vlan; *: Management-vlan;
--------------------------------------------------------------------------------
VID Ports
--------------------------------------------------------------------------------
10GE3/17/16(D)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
10GE3/4/1(U) 10GE3/17/15(U)
VID Type Status Property MAC-LRN STAT BC MC UC Description
--------------------------------------------------------------------------------
1 common enable default enable disable FWD FWD FWD VLAN 0001
19 common enable default enable disable FWD FWD FWD VLAN 0019
56 common enable default enable disable FWD FWD FWD VLAN 0056
57 common enable default enable disable FWD FWD FWD VLAN 0057
59 common enable default enable disable FWD FWD FWD VLAN 0059
240 common enable default enable disable FWD FWD FWD VLAN 0240
241 common enable default enable disable FWD FWD FWD VLAN 0241
242 common enable default enable disable FWD FWD FWD VLAN 0242
803 common enable default enable disable FWD FWD FWD VLAN 0803
813 common enable default enable disable FWD FWD FWD VLAN 0813
824 common enable default enable disable FWD FWD FWD VLAN 0824
[~CX912]