Professional Documents
Culture Documents
Nyirmix Catalog English PDF
Nyirmix Catalog English PDF
AND RAILWAY
COMPOSITE INSULATOR
MANUFACTURER
CATALOGUE
INTRODUCTION «
2 3
OUR CERTIFICATES «
4 5
OVERHEAD POWER LINE AND
» 1-24 kV INDOOR EPOXY INSULATORS RAILWAY COMPOSITE INSULATORS 1-24 kV INDOOR EPOXY INSULATORS «
LOW-VOLTAGE EPOXY INDOOR ∅d
B1 B2
Note:
The insulators can be coloured or
ordered in the materials’ colour.
Operation Dielectric Bending Tightening
Nominal temperature strength tensile torque Nominal Breaking
Type voltage (V) (C°) (kV/mm) strength (kN) [Nm] voltage force H ØD Ød M Weight
Type (kV) (kN) (mm) (mm) (mm) B1 B2 B3 (mm) (Kg)
H
SM 25 600 −40 - +150 12 1,5 30
ETA 12 12 6 130 55 55 M 12 M6 M 16 36 0,50
SM 30 600 −40 - +150 12 2,5 30
ETB 12 12 8 130 60 60 M 12 M6 M 16 36 0,55
SM 35 1000 −40 - +150 12 3,0 35
ETC 12 12 10 130 70 70 M 16 M 10 M 20 46 0,65
SM 40 1250 −40 - +150 12 4,0 40
IVEP
SM 45 1500 −40 - +150 12 4,5 40 12 6 130 55 55 M 10 M6 M 20 36 0,52
12A
SM 50 2000 −40 - +150 12 6,0 40
IVEP
12 8 130 72 72 M 16 M8 M 20 46 0,54
SM 65 3000 −40 - +150 12 6,0 40 12B B3
SM 75 5000 −40 - +150 12 8,0 40 ETA ∅D
12 4 110 55 45 M12 – M 12 – 0,40
12-1/M
SM 100 10000 −40 - +150 12 8,0 40
H
SM 50/2 50 40 50 M12 20 0,090
SM 65 65 32 41 M10 M12 20 0,185 Nominal Breaking
SM 75 75 38 60 M10 M12 25 0,230 voltage force H ØD Ød M Weight
Típus (kV) (kN) (mm) (mm) (mm) B1 B2 B3 (mm) (Kg)
SM 100 100 40 45 M12 30 0,520
IVEP
24 6 210 72 70 M 10 M6 M 16 36 1,3
24A
IVEP
24 8 210 85 85 M 16 M8 M 16 46 1,8 B3
24B
∅D
ETB 24 24 8 210 80 80 M 16 M 10 M 20 46 1,5
EPOXY INDOOR
1 KV BUSBAR INSULATORS ∅d
B1 B2
Note:
The insulators can be coloured or
ordered in the materials’ colour.
H
6 7
OVERHEAD POWER LINE AND
» OUTDOOR EPOXY INSULATORS RAILWAY COMPOSITE INSULATORS OUTDOOR EPOXY INSULATORS «
1 KV PIN AND ∅N
25 kV ∅B
∅D
TENSIONING INSULATORS ∅d PIN INSULATORS
H
H
∅d
∅D
A1
A2
Nominal Flashover Average Leakage
voltage voltage Wet breaking distance H ØD Ød Ø N
Type (kV) (kV) voltage (kV) force (kN) (mm) (mm) (mm) (mm) (mm)
MK-2
TENSIONING 1 40 10 10,6 83 76 42 24 – Lightning 50 Hz Bending ØB
INSULATOR Nominal impulse wet Leakage tensile (neck
voltage withstand voltage distance strength Height diameter) Threaded A1 A2
KT-1 PIN
1 40 10 10,6 70 80 50 28 50 Type (kV) voltage (kV) (kV) (mm) (kN) H (mm) B (mm) shaft (mm) (mm)
INSULATOR
TS 24-06 25 125 50 610 10 265 65 ZS 20 M 20 130 80
TS 24-02 25 125 50 610 12,5 265 65 ZS 20 M 20 130 80
EPOXY OUTDOOR
1 – 12 kV ∅d
M
25-38 kV ∅d
BUSBAR INSULATORS B1 B2 M
DEVICE INSULATORS B1 B3
H
Nominal Breaking
voltage force H ØD Ød M
Type (kV) (kN) (mm) (mm) (mm) B1 B2 B3 (mm) B3
∅D
KETB-1 1 4 50 60 50 M 12 --- M 12 ---
KETB 12 12 8 130 80 70 M 16 M 10 M 20 46
B2
∅D
1-3 kV
HÉV DISTRICT RAILWAY Lightning
SPECIAL INSULATORS SMCS 50/3 impulse 50 Hz Bending
Nominal withstand wet Leakage tensile
voltage voltage voltage distance strength ØD Ød B1 B2 B3
Type (kV) (kV) (kV) (mm) (kN) H (mm) (mm) (mm) (mm) (mm) (mm)
KSZ
25 125 50 600 4 280 65 60 – M 16 M6
24/5
KCS
38 180 85 835 4 360 60 70 – M 16 M 10
38,5
TS
36 170 70 700 8 330 90 80 – M 16 M 10
24-003
8 9
OVERHEAD POWER LINE AND
» COMPOSITE INSULATORS RAILWAY COMPOSITE INSULATORS COMPOSITE INSULATORS «
COMPOSITE COMPOSITE
ENDLESS THREAD FITTINGS AND
TENSIONING INSULATORS TENSIONING
RCD PROTECTED DESIGN
L
INSULATORS
H
L
H
Note:
The dimension of the bush:
as needed by the Customer.
H
L
∅d
SGH 25-2/E 25 E17-E17 230 110 365 740 70 450
SGH 25-2/F 25 E17-E17 125 50 284 625 70 450
Flash-
Lightning 50 Hz over Tensile SGL 24-1/M 25 E24-E24 145 70 260 620 70 453
Nominal impulse wet distance Leakage force Height SGL 24-2/M 25 E24-E24 200 100 310 740 70 515
voltage voltage voltage L distance SCL H Bore-hole Bore-hole PCD
Type (kV) (kV) (kV) (mm) (mm) (kN) (mm) D d bottom top Ø SGL 24-9/M 25 S16-S16 240 110 370 810 70 515
SGT 24/1R 25 125 50 252 615 5 270 65 65 2X M 10 2X M 10 36 SGL 24-10/M 25 E24-Y19 200 100 316 755 70 515
SGT 24-3/B 25 125 50 265 415 4 330 50 50 M 10 M 10 - SGL 24-12/M 25 T16-C16 240 110 360 805 70 520
SGT 24/1 25 145 70 260 625 4 300 50 50 M 12 M 12 - SGL 24-3/M 25 E24-E24 250 115 410 860 70 635
SGT 24/2 25 145 70 260 625 5 280 65 50 M 16 2X M 10 46 SBSI 35 35 E17-C16 190 80 675 1740 70 700
DRS 38 38 180 85 320 960 6 360 62 62 M 16 2X M 10 46 SBSI 35 35 E17-E17 190 80 675 1740 70 700
DRS 25 25 125 50 260 625 5 280 65 50 M 16 2X M 10 46 SBSG 35-1 35 T13-T13 190 80 632 860 70 780
SGK 24/2 25 145 70 252 615 5 270 65 65 2X M 10 2X M 8 36 SBSG 35-2 35 T16-T16 190 80 632 860 80 780
SGS 24/2 25 125 50 306 775 4 310 50 50 M 12 M 12 - SBSG 35 35 T19-T19 190 80 632 860 70 790
M 10
SGT 24-2/B 25 145 70 260 625 5 305 65 50 M 16 middle 36
2x M 8
10 11
OVERHEAD POWER LINE AND
» COMPOSITE INSULATORS RAILWAY COMPOSITE INSULATORS COMPOSITE INSULATORS «
COMPOSITE OMEGA-HEADED ∅N
∅N
110 kV
PIN INSULATORS 24-35 kV COMPOSITE INSULATORS
H
L L
H
L
Note:
At the Customer’s request the
insulators can be manufactured
with any other fittings.
A1
A2
Nominal Lightning impulse Wet Flash-over Leakage Tensile Installation
voltage withstand voltage voltage distance distance force distance
M M
Type Fitting (kV) (kV) (kV) L (mm) (mm) SML (kN) H (mm)
SOCKET-
SMH 110-S 110 550 230 1100 2575 120 1240
SOCKET
Lightning 50 Hz Flash- Tensile Ø
Nominal impulse wet over Leakage force (Neck SMH 110-V T22L-T22L 110 550 230 1100 2575 120 1295
voltage voltage voltage distance distance SCL Height diameter) Thread
Type (kV) (kV) (kV) L (mm) (mm) (kN) H (mm) N (mm) M (mm) A1 A2
H
M 20 L
SMT 24/0 25 125 50 203 540 10 310 50 120/210 80/100
M 24
M 20 62,105 55,60
SMT 24/0-L2 25 140 70 203 540 12,5 310 85
M 24 130,140 80,90
M 20 62,105 55,60
SMT 24/0-L 25 140 70 203 540 12,5 305 65
M 24 130,140 80,90
M 20 62,105 55,60
A1
SMT24/0-L3 25 160 80 250 600 12,5 320 65
M 24 130,140 80,90
A2
M 20 62,105 55,60
SMT 24/0-L1 25 140 70 203 540 12,5 305 65 M
M 24 130,140 80,90
12 13
OVERHEAD POWER LINE AND
» BIRD PROTECTION INSULATORS RAILWAY COMPOSITE INSULATORS FUSE DEVICES «
BIRD FUSE DEVICES E
PROTECTION 25-40,5 kV
INSULATORS
H
D
L
C
Notes:
Note: „E”= 2 x epoxy insulator or 2 x
At the Customer’s request the composite
G
insulators can be manufactured „TF”= 1 x epoxy insulator +
A
with any other fittings. 1 x overvoltage arrester or B
1 x composite insulator + F
1 x overvoltage arrester
Nominal Lightning impulse Flash-over Leakage Tensile force Installation Number
voltage withstand voltage Wet voltage distance distance SML distance of discs
Type Fitting (kV) (kV) (kV) L (mm) mm (kN) H (mm) (pieces)
Nominal Nominal Dimensions (mm)
SBSI-24 E17-C16 22 125 50 319 740 70 415 7 voltage amperage
Type (kV) (A) A B C D E F G H
SBSI-35 E17-C16 35 190 80 675 1740 70 700 18
KBSZ 24/E 24 100 300 605 50 365 442 600 100 458
SBSG 35-2 T16-T16 40,5 190 80 632 860 80 780 4
KBSZ 24/TF 24 100 300 605 50 365 442 600 100 458
KBSZ 35/E 35 100 310 575 50 360 538 650 100 515
KBSZ 40,5/E 40,5 100 375 575 50 410 538 720 100 595
INSULATED
CROSS ARM
800
0
123
804 804
FALL STOPS
14 15
OVERHEAD POWER LINE AND
» INSULATORS IN CHAIN RAILWAY COMPOSITE INSULATORS RAILWAY INSULATORS «
INSULATORS IN CHAIN FOR M12 TENSIONING
25 kV INSULATORS
L
M
12
H
~600
390
L
160 0
39
115
Tensile Szerelési
M12 M12 M12 Nominal Lightning impulse Voltage test Flash-over Leakage force távolság
voltage Head withstand voltage dry/wet distance distance (SML) H
Type (kV) fitting type +/- (kV) (kV) L (mm) (mm) (kN) (mm)
Ø 32X21,5
SMV-50 50 250/280 145/110 480 1060 70 482
GALVANIZED
Ø 32X21,5
160 160 SMV-50-1 50 250/280 145/110 480 1025 70 482
GALVANIZED
SMVB 50 50 TONGUE 250 150/115 480 1310 70 540
~600
390
~825
~795
390
440
390
440
SMVB 50/2 52 SOCKET EYE 250 150/115 480 1310 70 572
Ø 32X17X16
SMH 25-1 25 230 120 423 680 70 451
KO
Ø 40X21X19
SMR 25-1 25 250/280 145/110 620 1200 120 650
SLEEVE
∅N
Description Unit of measurement Value PIN INSULATORS
NOMINAL VOLTAGE kV 25
LIGHTNING IMPULSE VOLTAGE kV 125
50 Hz WET VOLTAGE kV 50
PIECE TEST RTL 70
HIGHEST TENSILE FORCE SML 35 L
CONTAMINATION I – II – III - IV
H
A1
A2
Lightning impulse Ø
Nominal withstand voltage Voltage test Flash-over Leakage Bending- Neck
voltage +- dry/wet voltage distance breaking force Height diameter
Type (kV) (kV) (kV) L (mm) (mm) (kN) H (mm) N (mm) A1 A2
16 17
OVERHEAD POWER LINE AND
» RAILWAY INSULATORS RAILWAY COMPOSITE INSULATORS CONTACTS «
TUBE THE COMPANY’S PRINCIPAL PLACE Address: 4461 Nyírtelek, Bethlen Gábor St. 1/a.
INSULATORS OF BUSINESS AND ITS PREMISES: Tel.: 06 42 210 517
e-mail: factory@nyirmix.hu
Nyírtelek
H
L
Nyíregyháza
Voltage Flash-
Nominal Lightning impulse test over Leakage Highest Highest bending-
voltage withstand voltage dry/wet distance distance tensile load breaking force Height
Type (kV) Fitting +- (kV) (kV) L (mm) (mm) STL (kN) SCL (kN) H (mm)
EARTHING
aluminium alloy
ROD 25 115 50 140 370 20 - 396
2 db
INSULATOR
SMCS 50/3
25 tube double-fork 115 50 140 370 36 3,5 326
TUBE-FORK
SMCS 50/3 tongue dou-
25 115 50 140 370 36 3,5 310
TONGUE-FORK ble-fork
www.nyirmix.hu
18 19
Nyír-Mix Trade Ltd.
4461 Nyírtelek, Bethlen Gábor St. 1/a.
4400 Nyíregyháza, Kossuth St. 70.
HUNGARY
www.nyirmix.hu